Your browser doesn't support javascript.
loading
Mapping of monoclonal antibody- and receptor-binding domains on human granulocyte-macrophage colony-stimulating factor (rhGM-CSF) using a surface plasmon resonance-based biosensor.
Laricchia-Robbio, L; Liedberg, B; Platou-Vikinge, T; Rovero, P; Beffy, P; Revoltella, R P.
Afiliação
  • Laricchia-Robbio L; Institute of Mutagenesis and Differentiation, C.N.R., Pisa, Italy.
Hybridoma ; 15(5): 343-50, 1996 Oct.
Article em En | MEDLINE | ID: mdl-8913783
ABSTRACT
An automated surface plasmon resonance (SPR)-based biosensor system has been used for mapping antibody and receptor-binding regions on the recombinant human granulocyte-macrophage colony-stimulating factor (rhGM-CSF) molecule. A rabbit antimouse IgG1-Fc antibody (RAM.Fc) was coupled to an extended carboxymethylated-hydrogel matrix attached to a gold surface in order to capture an anti-rhGM-CSF monoclonal antibody (MAb) injected over the sensing layer. rhGM-CSF was subsequently injected and allowed to bind to this antibody. Multisite binding assays were then performed, by flowing sequentially other antibodies and peptides over the surface, and the capacity of the latter to interact with the entrapped rhGM-CSF in a multimolecular complex was monitored in real time with SPR. Eleven MAb (all IgG1K), were analyzed respectively, four antipeptide MAb raised against three distinct epitopes of the cytokine (two clones against residues 14-24, that includes part of the first alpha-helix toward the N-terminal region; one clone against peptide 30-41, an intrahelical loop; and one clone against residues 79-91, including part of the third alpha-helix) and seven antiprotein MAbs raised against the entire rhGM-CSF, whose target native epitopes are still undetermined. In addition, the binding capacity to rhGM-CSF of a synthetic peptide, corresponding to residues 238-254 of the extracellular human GM-CSF receptor alpha-chain, endowed with rhGM-CSF binding activity, was tested. The results from experiments performed with the biosensor were compared with those obtained by a sandwich enzyme-linked immunosorbent assay (ELISA), using the same reagents. The features of the biosensor technology (fully automated, measure in real time, sharpened yes/no response, less background disturbances, no need for washing step or labeling of the reagent) offered several advantages in these studies of MAb immunoreactivity and epitope mapping, giving a much better resolution and enabling more distinct epitopes to be identified over ELISA.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Receptores Imunológicos / Fator Estimulador de Colônias de Granulócitos e Macrófagos / Mapeamento de Epitopos / Anticorpos Monoclonais Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Hybridoma Ano de publicação: 1996 Tipo de documento: Article País de afiliação: Itália
Buscar no Google
Base de dados: MEDLINE Assunto principal: Receptores Imunológicos / Fator Estimulador de Colônias de Granulócitos e Macrófagos / Mapeamento de Epitopos / Anticorpos Monoclonais Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Hybridoma Ano de publicação: 1996 Tipo de documento: Article País de afiliação: Itália