Continuous cardiac output and mixed venous oxygen saturation monitoring.
Cariou, A; Monchi, M; Dhainaut, J F.
Afiliação
  • Cariou A; Medical Intensive Care Unit, Cochin-Port Royal University Hospital, Paris, France.
J Crit Care ; 13(4): 198-213, 1998 Dec.
Article em En | MEDLINE | ID: mdl-9869547
Continuous assessment of cardiac output and SVO2 in the critically ill may be helpful in both the monitoring variations in the patient's cardiovascular state and in determining the efficacy of therapy. Commercially available continuous cardiac output (CCO) monitoring systems are based on the pulsed warm thermodilution technique. In vitro validation studies have demonstrated that this method provides higher accuracy and greater resistance to thermal noise than standard bolus thermodilution techniques. Numerous clinical studies comparing bolus with continuous thermodilution techniques have shown this technique similarly accurate to track each other and to have negligible bias between them. The comparison between continuous thermal and other cardiac output methods also demonstrates good precision of the continuous thermal technique. Accuracy of continuous oximetry monitoring using reflectance oximetry via fiberoptics has been assessed both in vitro and in vivo. Most of the studies testing agreement between continuous SVO2 measurements and pulmonary arterial blood samples measured by standard oximetry have shown good correlation. Continuous SVO2 monitoring is often used in the management of critically ill patients. The most recently designed pulmonary artery catheters are now able to simultaneously measure either SVO2 and CCO or SVO2 and right ventricular ejection fraction. This ability to view simultaneous trends of SVO2 and right ventricular performance parameters will probably allow the clinician to graphically see the impact of volume loading or inotropic therapy over time, as well as the influence of multiple factors, including right ventricular dysfunction, on SVO2. However, the cost-effectiveness of new pulmonary artery catheters application remains still questionable because no established utility or therapeutic guidelines are available.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Termodiluição / Oximetria / Débito Cardíaco Tipo de estudo: Guideline / Prognostic_studies Limite: Animals / Humans Idioma: En Revista: J Crit Care Assunto da revista: TERAPIA INTENSIVA Ano de publicação: 1998 Tipo de documento: Article País de afiliação: França
Buscar no Google
Base de dados: MEDLINE Assunto principal: Termodiluição / Oximetria / Débito Cardíaco Tipo de estudo: Guideline / Prognostic_studies Limite: Animals / Humans Idioma: En Revista: J Crit Care Assunto da revista: TERAPIA INTENSIVA Ano de publicação: 1998 Tipo de documento: Article País de afiliação: França