Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 187
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
2.
Nature ; 634(8035): 761-762, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39406846
3.
Nature ; 630(8018): 807-809, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38890516
5.
Nature ; 629(8012): 521-523, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38653827
6.
Nature ; 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38438609
8.
Nature ; 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38485829
10.
Nature ; 2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38243121
11.
Nature ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38570659
12.
J Am Acad Dermatol ; 91(2): 273-280, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38556093

RESUMO

BACKGROUND: Efficacy and/or safety profiles limit topical psoriasis treatments. OBJECTIVE: Evaluate long-term effects of once-daily roflumilast cream 0.3% in patients with psoriasis. METHODS: In this open-label phase 2 trial, adult patients (N = 332) with psoriasis who completed the phase 2b parent trial or were newly enrolled applied roflumilast once-daily for 52 weeks. Safety and effectiveness were assessed. RESULTS: Overall, 244 patients (73.5%) completed the trial; 13 patients (3.9%) discontinued due to adverse events (AEs) and 3 (0.9%) due to lack of efficacy. Twelve patients (3.6%) reported treatment-related AEs; none were serious. ≥97% of patients had no irritation. No tachyphylaxis was observed with 44.8% of the patients achieving Investigator Global Assessment (IGA) Clear or Almost Clear at Week 52. LIMITATIONS: Intertriginous-IGA and Psoriasis Area and Severity Index (PASI) were not evaluated in all patients. CONCLUSIONS: In this long-term trial, once-daily roflumilast cream was well-tolerated and efficacious up to 64 weeks in patients in the earlier trial, suggesting it is suitable for chronic treatment, including the face and intertriginous areas.


Assuntos
Aminopiridinas , Benzamidas , Ciclopropanos , Inibidores da Fosfodiesterase 4 , Psoríase , Índice de Gravidade de Doença , Creme para a Pele , Humanos , Ciclopropanos/administração & dosagem , Ciclopropanos/efeitos adversos , Ciclopropanos/uso terapêutico , Psoríase/tratamento farmacológico , Aminopiridinas/administração & dosagem , Aminopiridinas/efeitos adversos , Benzamidas/efeitos adversos , Benzamidas/administração & dosagem , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Inibidores da Fosfodiesterase 4/administração & dosagem , Inibidores da Fosfodiesterase 4/efeitos adversos , Resultado do Tratamento , Creme para a Pele/administração & dosagem , Creme para a Pele/efeitos adversos , Doença Crônica , Idoso , Esquema de Medicação , Fatores de Tempo , Adulto Jovem
14.
19.
J Appl Clin Med Phys ; 25(10): e14485, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39190567

RESUMO

PURPOSE: A single treatment planning system (TPS) model for matched linacs provides flexible clinical workflows from patient treatment to intensity-modulated radiation therapy (IMRT) quality assurance (QA) measurement. Since general guidelines for building a single TPS model and its validation for matched linacs are not well established, we present our RayStation photon TPS modeling strategy for matched Elekta VersaHD linacs. METHOD: The four linacs installed from 2013 to 2020 were matched in terms of Percent Depth Dose (PDD), profile, output factor and wedge factors for 6-MV, 10-MV, 15-MV, and 6-MV-FFF, and maintained following TG-142 recommendations until RayStation commissioning. The RayStation single model was built to represent all four linacs within the tolerance limits recommended by MPPG-5.a. The comprehensive validation tests were performed for one linac following MPPG-5.a and TG-119 guidelines, and spot checks for the other three. Our TPS modeling/validation method was evaluated by re-analyzing the previous 103 patient-specific IMRT/volumetric modulated arc therapy (VMAT) QA measurements with the calculated planar doses by the single model in comparison with the analysis results using four individual Pinnacle TPS models. RESULTS: For all energies, our single model PDDs were within 1% agreement of the four-linac commissioning measurements. The MPPG-5.a validation tests from 5.1 through 7.5 and all TG-119 measurements passed within the recommended tolerance limits. The IMRT QA results (mean ± standard deviation) for RayStation single model versus Pinnacle individual models were 98.9% ± 1.3% and 98.0% ± 1.4% for 6-MV, 99.9% ± 0.1% and 99.1% ± 1.9% for 10-MV, and 98.2% ± 1.3% and 97.9% ± 1.8% for 6-MV-FFF, respectively. CONCLUSION: We successfully built and validated a single photon beam model in RayStation for four Elekta Linacs. The proposed new validation methods were proven to be both efficient and effective.


Assuntos
Aceleradores de Partículas , Fótons , Garantia da Qualidade dos Cuidados de Saúde , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Radioterapia de Intensidade Modulada/métodos , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Fótons/uso terapêutico , Aceleradores de Partículas/instrumentação , Garantia da Qualidade dos Cuidados de Saúde/normas , Neoplasias/radioterapia , Imagens de Fantasmas
20.
Eur Radiol ; 33(10): 6948-6958, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37195432

RESUMO

OBJECTIVES: To evaluate at 1.5 and 3 T MRI the safety and performance of trademarked ENO®, TEO®, or OTO® pacing systems with automated MRI Mode and the image quality of non-enhanced MR examinations. METHODS: A total of 267 implanted patients underwent MRI examination (brain, cardiac, shoulder, cervical spine) at 1.5 (n = 126) or 3 T (n = 141). MRI-related device complications, lead electrical performances stability at 1-month post-MRI, proper functioning of the automated MRI mode and image quality were evaluated. RESULTS: Freedom from MRI-related complications at 1 month post-MRI was 100% in both 1.5 and 3 T arms (both p < 0.0001). The stability of pacing capture threshold was respectively at 1.5 and 3 T (atrial:: 98.9% (p = 0.001) and 100% (p < 0.0001); ventricular: both 100% (p < 0001)). The stability of sensing was respectively at 1.5 and 3 T (atrial: 100% (p = 0.0001) and 96.9% (p = 0.01); ventricular: 100% (p < 0.0001) and 99.1% (p = 0.0001)). All devices switched automatically to the programmed asynchronous mode in the MRI environment and to initially programmed mode after the MRI exam. While all MR examinations were assessed as interpretable, artifacts deteriorated a subset of examinations including mostly cardiac and shoulder ones. CONCLUSION: This study demonstrates the safety and electrical stability of ENO®, TEO®, or OTO® pacing systems at 1 month post-MRI at 1.5 and 3 T. Even if artifacts were noticed in a subset of examinations, overall interpretability was preserved. CLINICAL RELEVANCE STATEMENT: ENO®, TEO®, and OTO® pacing systems switch to MR-mode when detecting magnetic field and switch back on conventional mode after MRI. Their safety and electrical stability at 1 month post MRI were shown at 1.5 and 3 T. Overall interpretability was preserved. KEY POINTS: • Patients implanted with an MRI conditional cardiac pacemaker can be safely scanned under 1.5 or 3 Tesla MRI with preserved interpretability. • Electrical parameters of the MRI conditional pacing system remain stable after a 1.5 or 3 Tesla MRI scan. • The automated MRI mode enabled the automatic switch to asynchronous mode in the MRI environment and to initial settings after the MRI scan in all patients.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Humanos , Segurança de Equipamentos/métodos , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa