Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Appl Clin Med Phys ; 23(10): e13745, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36018627

RESUMO

PURPOSE: The Task Group 218 (TG-218) report was published by the American Association of Physicists in Medicine in 2018, recommending the appropriate use of gamma index analysis for patient-specific quality assurance (PSQA). The paper demonstrates that PSQA for radiotherapy in Japan appropriately applies the gamma index analysis considering TG-218. MATERIALS/METHODS: This survey estimated the acceptance state of radiotherapeutic institutes or facilities in Japan for the guideline using a web-based questionnaire. To investigate an appropriate PSQA of the facility-specific conditions, we researched an optimal tolerance or action level for various clinical situations, including different treatment machines, clinical policies, measurement devices, staff or their skills, and patient conditions. The responded data were analyzed using principal component analysis (PCA) and multidimensional scaling (MDS). The PCA focused on factor loading values of the first contribution over 0.5, whereas the MDS focused on mapped distances among data. RESULTS: Responses were obtained from 148 facilities that use intensity-modulated radiation therapy (IMRT), which accounted for 42.8% of the probable IMRT use in Japan. This survey revealed the appropriate application of the following universal criteria for gamma index analysis from the guideline recommendation despite the facility-specific variations (treatment machines/the number of IMRT cases/facility attributes/responded [representative] expertise or staff): (a) 95% pass rate, (b) 3% dose difference and 2-mm distance-to-agreement, and (c) 10% threshold dose. Conditions (a)-(c) were the principal components of the data by the PCA method and were mapped in a similar distance range, which was easily clustered from other gamma index analytic factors by the MDS method. Conditions (a)-(c) were the universally essential factors for the PSQA in Japan. CONCLUSION: We found that the majority of facilities using IMRT in each region of Japan complied with the guideline and conducted PSQA with deliberation under the individual facility-specific conditions.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Japão , Garantia da Qualidade dos Cuidados de Saúde , Radioterapia de Intensidade Modulada/métodos
2.
Med Phys ; 51(1): 509-521, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37672219

RESUMO

BACKGROUND: Evaluation of the boron dose is essential for boron neutron capture therapy (BNCT). Nevertheless, a direct evaluation method for the boron-dose distribution has not yet been established in the clinical BNCT field. To date, even in quality assurance (QA) measurements, the boron dose has been indirectly evaluated from the thermal neutron flux measured using the activation method with gold foil or wire and an assumed boron concentration in the QA procedure. Recently, we successfully conducted optical imaging of the boron-dose distribution using a cooled charge-coupled device (CCD) camera and a boron-added liquid scintillator at the E-3 port facility of the Kyoto University Research Reactor (KUR), which supplies an almost pure thermal neutron beam with very low gamma-ray contamination. However, in a clinical accelerator-based BNCT facility, there is a concern that the boron-dose distribution may not be accurately extracted because the unwanted luminescence intensity, which is irrelevant to the boron dose is expected to increase owing to the contamination of fast neutrons and gamma rays. PURPOSE: The purpose of this research was to study the validity of a newly proposed method using a boron-added liquid scintillator and a cooled CCD camera to directly observe the boron-dose distribution in a clinical accelerator-based BNCT field. METHOD: A liquid scintillator phantom with 10 B was prepared by filling a small quartz glass container with a commercial liquid scintillator and boron-containing material (trimethyl borate); its natural boron concentration was 1 wt%. Luminescence images of the boron-neutron capture reaction were obtained in a water tank at several different depths using a CCD camera. The contribution of background luminescence, mainly due to gamma rays, was removed by subtracting the luminescence images obtained using another sole liquid scintillator phantom (natural boron concentration of 0 wt%) at each corresponding depth, and a depth profile of the boron dose with several discrete points was obtained. The obtained depth profile was compared with that of calculated boron dose, and those of thermal neutron flux which were experimentally measured or calculated using a Monte Carlo code. RESULTS: The depth profile evaluated from the subtracted images indicated reasonable agreement with the calculated boron-dose profile and thermal neutron flux profiles, except for the shallow region. This discrepancy is thought to be due to the contribution of light reflected from the tank wall. The simulation results also demonstrated that the thermal neutron flux would be severely perturbed by the 10 B-containing phantom if a relatively larger container was used to evaluate a wide range of boron-dose distributions in a single shot. This indicates a trade-off between the luminescence intensity of the 10 B-added phantom and its perturbation effect on the thermal neutron flux. CONCLUSIONS: Although a partial discrepancy was observed, the validity of the newly proposed boron-dose evaluation method using liquid-scintillator phantoms with and without 10 B was experimentally confirmed in the neutron field of an accelerator-based clinical BNCT facility. However, this study has some limitations, including the trade-off problem stated above. Therefore, further studies are required to address these limitations.


Assuntos
Terapia por Captura de Nêutron de Boro , Boro , Humanos , Terapia por Captura de Nêutron de Boro/métodos , Estudos de Viabilidade , Nêutrons , Imagens de Fantasmas , Método de Monte Carlo , Imagem Óptica , Dosagem Radioterapêutica
3.
Sci Rep ; 12(1): 13778, 2022 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-35962034

RESUMO

In June 2020, the Japanese government approved boron neutron capture therapy for the treatment of head and neck cancer. The treatment is usually performed in a single fraction, with the neutron irradiation time being approximately 30-60 min. As neutrons scatter in air and loses its intensity, it is preferable to bring the patient as close to the beam port as possible to shorten the irradiation time. However, this can be a challenge, especially for patients with head and neck cancer, as the shoulders are an obstacle to a clean positioning. In this study, a novel neutron collimation system for an accelerator based neutron source was designed to allow for a more comfortable treatment, without compromising the irradiation time. Experimental measurements confirmed the simulation results and showed the new collimator can reduce the irradiation time by approximately 60% (under the same condition where the distance between the source and the patient surface was kept the same). The dose delivered to the surrounding healthy tissue was reduced with the new collimator, showing a 25% decrease in the D50 of the mucosal membrane. Overall, the use of the newly designed collimator will allow for a more comfortable treatment of the head and neck region, reduce the treatment time, and reduce the dose delivered to the surrounding healthy tissue.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias de Cabeça e Pescoço , Terapia por Captura de Nêutron de Boro/métodos , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Método de Monte Carlo , Nêutrons , Dosagem Radioterapêutica
4.
Radiat Oncol ; 16(1): 243, 2021 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-34952608

RESUMO

Boron neutron capture therapy (BNCT) for the treatment of unresectable, locally advanced, and recurrent carcinoma of the head and neck cancer has been approved by the Japanese government for reimbursement under the national health insurance as of June 2020. A new treatment planning system for clinical BNCT has been developed by Sumitomo Heavy Industries, Ltd. (Sumitomo), NeuCure® Dose Engine. To safely implement this system for clinical use, the simulated neutron flux and gamma ray dose rate inside a water phantom was compared against experimental measurements. Furthermore, to validate and verify the new planning system, the dose distribution inside an anthropomorphic head phantom was compared against a BNCT treatment planning system SERA and an in-house developed Monte Carlo dose calculation program. The simulated results closely matched the experimental results, within 5% for the thermal neutron flux and 10% for the gamma ray dose rate. The dose distribution inside the head phantom closely matched with SERA and the in-house developed dose calculation program, within 3% for the tumour and a difference of 0.3 Gyw for the brain.


Assuntos
Terapia por Captura de Nêutron de Boro/métodos , Neoplasias de Cabeça e Pescoço/radioterapia , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Dosagem Radioterapêutica
5.
Phys Med ; 64: 182-187, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31515018

RESUMO

Over the last several decades, there have been great advances in radiotherapy with the development of new technologies and modalities, and radiotherapy trends have changed rapidly. To comprehend the current state of radiotherapy in Japan, the QA/QC 2016-2017 Committee of the Japan Society of Medical Physics set up an intensity-modulated radiotherapy/image-guided radiotherapy (IMRT/IGRT) working group and performed a Web-based survey to show the current status of radiotherapy in Japan. The Web-based questionnaire, developed using Google Forms, contained 42 items: 7 on stereotactic radiotherapy implementation, 4 on IMRT, 24 on IGRT, and 7 on respiratory motion management. The survey was conducted from 17 January to 9 March of 2018; in total, 335 institutions provided data. The results show that volumetric modulated arc therapy was used at a level comparable to that of static gantry IMRT. For IGRT, machine-integrated computed tomography (CT), including kilovoltage or megavoltage cone-beam CT and megavoltage CT, was used at many institutions in conjunction with target-based image registration. For respiratory motion management, breath holding was the most commonly used technique. Our hope is that multi-institutional surveys such as this one will be conducted periodically to elucidate the current status of radiotherapy and emerging developments in this field. If our questionnaire was distributed worldwide, in the same format, then global trends in radiotherapy could be better understood.


Assuntos
Radiocirurgia/estatística & dados numéricos , Radioterapia Guiada por Imagem/estatística & dados numéricos , Radioterapia de Intensidade Modulada/estatística & dados numéricos , Sociedades Científicas , Inquéritos e Questionários , Humanos , Internet , Japão , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia
6.
Mol Med Rep ; 7(4): 1091-5, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23404144

RESUMO

The aim of this study was to investigate whether sivelestat, a neutrophil elastase (NE) inhibitor, mitigates radiation-induced lung injury in mice. C57BL/6J mice were administered a dose of 20 Gy to the bilateral whole lungs. Sivelestat was administered immediately before and 1 h after irradiation in group RE2, and immediately before and 1, 3 and 6 h after irradiation in group RE4. Group R received irradiation without sivelestat injection. Mice that did not receive sivelestat injection or irradiation were used as controls. NE activity was measured 24 and 48 h after irradiation, and the mice were sacrificed 24 h, 48 h and 15 weeks after irradiation for histopathological examination. In groups RE2 and RE4, NE activity was significantly suppressed until 48 h after irradiation compared to group R. The degree of lung damage in each group was scored during histopathological examination. Results showed that the scores of groups RE2 and RE4 were significantly lower compared to those of group R 15 weeks after irradiation. In conclusion, sivelestat reduced radiation­induced lung injury in the mice by suppressing NE activity and excessive inflammatory reactions.


Assuntos
Glicina/análogos & derivados , Elastase de Leucócito/metabolismo , Pulmão/efeitos dos fármacos , Protetores contra Radiação/administração & dosagem , Sulfonamidas/administração & dosagem , Anormalidades Induzidas por Radiação/tratamento farmacológico , Anormalidades Induzidas por Radiação/patologia , Animais , Glicina/administração & dosagem , Humanos , Inflamação/tratamento farmacológico , Inflamação/enzimologia , Inflamação/patologia , Elastase de Leucócito/antagonistas & inibidores , Pulmão/patologia , Pulmão/efeitos da radiação , Lesão Pulmonar/tratamento farmacológico , Lesão Pulmonar/patologia , Camundongos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa