Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 132(17): 171001, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38728703

RESUMO

Recently a dark matter-electron (DM-electron) paradigm has drawn much attention. Models beyond the standard halo model describing DM accelerated by high energy celestial bodies are under intense examination as well. In this Letter, a velocity components analysis (VCA) method dedicated to swift analysis of accelerated DM-electron interactions via semiconductor detectors is proposed and the first HPGe detector-based accelerated DM-electron analysis is realized. Utilizing the method, the first germanium based constraint on sub-GeV solar reflected DM-electron interaction is presented with the 205.4 kg·day dataset from the CDEX-10 experiment. In the heavy mediator scenario, our result excels in the mass range of 5-15 keV/c^{2}, achieving a 3 orders of magnitude improvement comparing with previous semiconductor experiments. In the light mediator scenario, the strongest laboratory constraint for DM lighter than 0.1 MeV/c^{2} is presented. The result proves the feasibility and demonstrates the vast potential of the VCA technique in future accelerated DM-electron analyses with semiconductor detectors.

2.
Phys Rev Lett ; 129(22): 221301, 2022 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-36493436

RESUMO

We present improved germanium-based constraints on sub-GeV dark matter via dark matter-electron (χ-e) scattering using the 205.4 kg·day dataset from the CDEX-10 experiment. Using a novel calculation technique, we attain predicted χ-e scattering spectra observable in high-purity germanium detectors. In the heavy mediator scenario, our results achieve 3 orders of magnitude of improvement for m_{χ} larger than 80 MeV/c^{2} compared to previous germanium-based χ-e results. We also present the most stringent χ-e cross-section limit to date among experiments using solid-state detectors for m_{χ} larger than 90 MeV/c^{2} with heavy mediators and m_{χ} larger than 100 MeV/c^{2} with electric dipole coupling. The result proves the feasibility and demonstrates the vast potential of a new χ-e detection method with high-purity germanium detectors in ultralow radioactive background.


Assuntos
Eletricidade , Elétrons
3.
Phys Rev Lett ; 129(22): 221802, 2022 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-36493447

RESUMO

A search for exotic dark matter (DM) in the sub-GeV mass range has been conducted using 205 kg day data taken from a p-type point contact germanium detector of the CDEX-10 experiment at China's Jinping underground laboratory. New low-mass dark matter searching channels, neutral current fermionic DM absorption (χ+A→ν+A) and DM-nucleus 3→2 scattering (χ+χ+A→ϕ+A), have been analyzed with an energy threshold of 160 eVee. No significant signal was found; thus new limits on the DM-nucleon interaction cross section are set for both models at the sub-GeV DM mass region. A cross section limit for the fermionic DM absorption is set to be 2.5×10^{-46} cm^{2} (90% C.L.) at DM mass of 10 MeV/c^{2}. For the DM-nucleus 3→2 scattering scenario, limits are extended to DM mass of 5 and 14 MeV/c^{2} for the massless dark photon and bound DM final state, respectively.


Assuntos
Núcleo Celular , Fótons
4.
Phys Rev Lett ; 124(11): 111301, 2020 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-32242731

RESUMO

We report constraints on the dark photon effective kinetic mixing parameter (κ) with data taken from two p-type point-contact germanium detectors of the CDEX-10 experiment at the China Jinping Underground Laboratory. The 90% confidence level upper limits on κ of solar dark photon from 205.4 kg-day exposure are derived, probing new parameter space with masses (m_{V}) from 10 to 300 eV/c^{2} in direct detection experiments. Considering dark photon as the cosmological dark matter, limits at 90% confidence level with m_{V} from 0.1 to 4.0 keV/c^{2} are set from 449.6 kg-day data, with a minimum of κ=1.3×10^{-15} at m_{V}=200 eV/c^{2}.

5.
Phys Rev Lett ; 123(16): 161301, 2019 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-31702340

RESUMO

We report results on the searches of weakly interacting massive particles (WIMPs) with sub-GeV masses (m_{χ}) via WIMP-nucleus spin-independent scattering with Migdal effect incorporated. Analysis on time-integrated (TI) and annual modulation (AM) effects on CDEX-1B data are performed, with 737.1 kg day exposure and 160 eVee threshold for TI analysis, and 1107.5 kg day exposure and 250 eVee threshold for AM analysis. The sensitive windows in m_{χ} are expanded by an order of magnitude to lower DM masses with Migdal effect incorporated. New limits on σ_{χN}^{SI} at 90% confidence level are derived as 2×10^{-32}∼7×10^{-35} cm^{2} for TI analysis at m_{χ}∼50-180 MeV/c^{2}, and 3×10^{-32}∼9×10^{-38} cm^{2} for AM analysis at m_{χ}∼75 MeV/c^{2}-3.0 GeV/c^{2}.

6.
Phys Rev Lett ; 123(22): 221301, 2019 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-31868422

RESUMO

We present results on light weakly interacting massive particle (WIMP) searches with annual modulation (AM) analysis on data from a 1-kg mass p-type point-contact germanium detector of the CDEX-1B experiment at the China Jinping Underground Laboratory. Datasets with a total live time of 3.2 yr within a 4.2-yr span are analyzed with analysis threshold of 250 eVee. Limits on WIMP-nucleus (χ-N) spin-independent cross sections as function of WIMP mass (m_{χ}) at 90% confidence level (C.L.) are derived using the dark matter halo model. Within the context of the standard halo model, the 90% C.L. allowed regions implied by the DAMA/LIBRA and CoGeNT AM-based analysis are excluded at >99.99% and 98% C.L., respectively. These results correspond to the best sensitivity at m_{χ}<6 GeV/c^{2} among WIMP AM measurements to date.

7.
Phys Rev Lett ; 120(24): 241301, 2018 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-29956956

RESUMO

We report the first results of a light weakly interacting massive particles (WIMPs) search from the CDEX-10 experiment with a 10 kg germanium detector array immersed in liquid nitrogen at the China Jinping Underground Laboratory with a physics data size of 102.8 kg day. At an analysis threshold of 160 eVee, improved limits of 8×10^{-42} and 3×10^{-36} cm^{2} at a 90% confidence level on spin-independent and spin-dependent WIMP-nucleon cross sections, respectively, at a WIMP mass (m_{χ}) of 5 GeV/c^{2} are achieved. The lower reach of m_{χ} is extended to 2 GeV/c^{2}.

8.
Arch Virol ; 147(1): 1-10, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-11858230

RESUMO

JC virus (JCV) strains worldwide can be classified into various genotypes based on DNA sequence variations. To define the domains of the four major JCV genotypes in Asia, we collected urine samples at six unstudied sites: three in southeastern Asia, two in the central highlands and one in central Asia. DNA was extracted from urine samples, and used to amplify a 610-bp region of the viral genome. For each geographical site, we determined 16 to 31 sequences, from which a phylogenetic tree was constructed to unambiguously classify detected JCV isolates into distinct genotypes. From JCV genotype profiles at the sites studied here and elsewhere, the following conclusions were drawn. Although Af2 is the major genotype in Africa, this genotype also occurs in western and central Asia. B1-b mainly occurs in western and central Asia, including the central highlands. CY occurs in northeastern Asia with the southern boundary between China and southeast Asian countries. Although SC predominates in southeastern Asia, it also occurs in northern and central Asia at lower frequencies. In addition, a few minor JCV genotypes (B1-a, B2 and B3) occur at many sites. We discuss here the anthropological and medical significance of the present findings.


Assuntos
Vírus JC/classificação , Vírus JC/genética , Infecções por Polyomavirus/virologia , Adulto , Ásia , DNA Viral/urina , Variação Genética , Genética Populacional , Genótipo , Humanos , Dados de Sequência Molecular , Filogenia , Prevalência , Análise de Sequência de DNA , Infecções Tumorais por Vírus/virologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa