RESUMO
Background Photon-counting detector (PCD) CT provides comprehensive spectral data with every acquisition, but studies evaluating myocardial extracellular volume (ECV) quantification with use of PCD CT compared with an MRI reference remain lacking. Purpose To compare ECV quantification for myocardial tissue characterization between a first-generation PCD CT system and cardiac MRI. Materials and Methods In this single-center prospective study, adults without contraindication to iodine-based contrast media underwent same-day cardiac PCD CT and MRI with native and postcontrast T1 mapping and late gadolinium enhancement for various clinical indications for cardiac MRI (the reference standard) between July 2021 and January 2022. Global and midventricular ECV were assessed with use of three methods: single-energy PCD CT, dual-energy PCD CT, and MRI T1 mapping. Quantitative comparisons among all techniques were performed. Correlation and reliability between different methods of ECV quantification were assessed with use of the Pearson correlation coefficient (r) and the intraclass correlation coefficient. Results The final sample included 29 study participants (mean age ± SD, 54 years ± 17; 15 men). There was a strong correlation of ECV between dual- and single-energy PCD CT (r = 0.91, P < .001). Radiation dose was 40% lower with dual-energy versus single-energy PCD CT (volume CT dose index, 10.1 mGy vs 16.8 mGy, respectively; P < .001). In comparison with MRI, dual-energy PCD CT showed strong correlation (r = 0.82 and 0.91, both P < .001) and good to excellent reliability (intraclass correlation coefficients, 0.81 and 0.90) for midventricular and global ECV quantification, but it overestimated ECV by approximately 2%. Single-energy PCD CT showed similar relationship with MRI but underestimated ECV by 3%. Conclusion Myocardial tissue characterization with photon-counting detector CT-based quantitative extracellular volume analysis showed a strong correlation to MRI. © RSNA, 2023 Supplemental material is available for this article.
Assuntos
Meios de Contraste , Gadolínio , Masculino , Adulto , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodosRESUMO
OBJECTIVES: To assess the impact of scan modes and reconstruction kernels using a novel dual-source photon-counting detector CT (PCD-CT) on lumen visibility and sharpness of different stent sizes. METHODS: A phantom containing six balloon-expandable stents (2.5 to 9 mm diameter) in silicone tubing was scanned on a PCD-CT with standard (0.6 mm and 0.4 mm thicknesses) and ultra-high-resolution (0.2 mm thickness) modes. With the use of increasing contrast medium concentrations, densities of 0, 200, 400, and 600 HU were achieved. Standard-resolution scans were reconstructed using increasing sharpness kernels, using both polyenergetic quantitative soft tissue "conventional" ((Qr40c(0.6 mm), Qr40c(0.4 mm), Qr72c(0.2 mm)) and vascular (Bv) virtual monoenergetic reconstructions (Bv44m(0.4 mm), Bv60m(0.4 mm)) at 70 keV. In-stent lumen visibility, sharpness (max. ΔHU of the stent measured in profile plots), and in-stent noise (standard deviation of HU) were measured. RESULTS: In-stent lumen visibility was highest for Qr72c(0.2 mm) (86.5 ± 2.8% to 88.3 ± 2.6%) and in Bv60m(0.4 mm) reconstructions (77.3 ± 2.9 to 82.7 ± 2.5%). Lumen visibility was lowest in the smallest stent (2.5 mm) ranging from 54.1% in Qr40c(0.6 mm) to 74.1% in Qr72c(0.2 mm) and highest in the largest stent (9 mm) ranging from 93.8% in Qr40c(0.6 mm) to 99.1% in the Qr72c(0.2 mm) series. Lumen visibility decreased by 2.1% for every 200-HU increase in lumen attenuation. Max. ΔHU between stents and stent lumen was highest in Qr72c(0.2 mm) (ΔHU 892 ± 504 to 1526 ± 517) and Bv60m(0.4 mm) series (ΔHU 480 ± 357 to 1030 ± 344). Improvement of lumen visibility and sharpness in UHR and Bv60m(0.4 mm) series was strongest in smaller stent sizes. CONCLUSION: UHR acquisition mode and sharp reconstruction kernels on a novel PCD-CT system significantly improve in-stent lumen visibility and sharpness-especially for smaller stent sizes. KEY POINTS: ⢠In-stent lumen visibility and sharpness of stents significantly improve using sharp reconstruction kernels (Bv60) and ultra-high-resolution mode in photon-counting detector computed tomography. ⢠The observed improvement of stent-lumen visibility was highest in smaller stent sizes.
Assuntos
Stents , Tomografia Computadorizada por Raios X , Humanos , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Imagens de FantasmasRESUMO
Background The role of CT angiography-derived fractional flow reserve (CT-FFR) in pre-transcatheter aortic valve replacement (TAVR) assessment is uncertain. Purpose To evaluate the predictive value of on-site machine learning-based CT-FFR for adverse clinical outcomes in candidates for TAVR. Materials and Methods This observational retrospective study included patients with severe aortic stenosis referred to TAVR after coronary CT angiography (CCTA) between September 2014 and December 2019. Clinical end points comprised major adverse cardiac events (MACE) (nonfatal myocardial infarction, unstable angina, cardiac death, or heart failure admission) and all-cause mortality. CT-FFR was obtained semiautomatically using an on-site machine learning algorithm. The ability of CT-FFR (abnormal if ≤0.75) to predict outcomes and improve the predictive value of the current noninvasive work-up was assessed. Survival analysis was performed, and the C-index was used to assess the performance of each predictive model. To compare nested models, the likelihood ratio χ2 test was performed. Results A total of 196 patients (mean age ± standard deviation, 75 years ± 11; 110 women [56%]) were included; the median time of follow-up was 18 months. MACE occurred in 16% (31 of 196 patients) and all-cause mortality in 19% (38 of 196 patients). Univariable analysis revealed CT-FFR was predictive of MACE (hazard ratio [HR], 4.1; 95% CI: 1.6, 10.8; P = .01) but not all-cause mortality (HR, 1.2; 95% CI: 0.6, 2.2; P = .63). CT-FFR was independently associated with MACE (HR, 4.0; 95% CI: 1.5, 10.5; P = .01) when adjusting for potential confounders. Adding CT-FFR as a predictor to models that include CCTA and clinical data improved their predictive value for MACE (P = .002) but not all-cause mortality (P = .67), and it showed good discriminative ability for MACE (C-index, 0.71). Conclusion CT angiography-derived fractional flow reserve was associated with major adverse cardiac events in candidates for transcatheter aortic valve replacement and improved the predictive value of coronary CT angiography assessment. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Choe in this issue.
Assuntos
Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Cuidados Pré-Operatórios/métodos , Substituição da Valva Aórtica Transcateter , Idoso , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Medição de RiscoRESUMO
OBJECTIVES: To evaluate feasibility and diagnostic performance of coronary CT angiography (CCTA)-derived fractional flow reserve (CT-FFR) for detection of significant coronary artery disease (CAD) and decision-making in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) to potentially avoid additional pre-TAVR invasive coronary angiography (ICA). METHODS: Consecutive patients with severe AS (n = 95, 78.6 ± 8.8 years, 53% female) undergoing pre-procedural TAVR-CT followed by ICA with quantitative coronary angiography were retrospectively analyzed. CCTA datasets were evaluated using CAD Reporting and Data System (CAD-RADS) classification. CT-FFR measurements were computed using an on-site machine-learning algorithm. A combined algorithm was developed for decision-making to determine if ICA is needed based on pre-TAVR CCTA: [1] all patients with CAD-RADS ≥ 4 are referred for ICA; [2] patients with CAD-RADS 2 and 3 are evaluated utilizing CT-FFR and sent to ICA if CT-FFR ≤ 0.80; [3] patients with CAD-RADS < 2 or CAD-RADS 2-3 and normal CT-FFR are not referred for ICA. RESULTS: Twelve patients (13%) had significant CAD (≥ 70% stenosis) on ICA and were treated with PCI. Twenty-eight patients (30%) showed CT-FFR ≤ 0.80 and 24 (86%) of those were reported to have a maximum stenosis ≥ 50% during ICA. Using the proposed algorithm, significant CAD could be identified with a sensitivity, specificity, and positive and negative predictive value of 100%, 78%, 40%, and 100%, respectively, potentially decreasing the number of necessary ICAs by 65 (68%). CONCLUSION: Combination of CT-FFR and CAD-RADS is able to identify significant CAD pre-TAVR and bears potential to significantly reduce the number of needed ICAs. KEY POINTS: ⢠Coronary CT angiography-derived fractional flow reserve (CT-FFR) using machine learning together with the CAD Reporting and Data System (CAD-RADS) classification safely identifies significant coronary artery disease based on quantitative coronary angiography in patients prior to transcatheter aortic valve replacement. ⢠The combination of CT-FFR and CAD-RADS enables decision-making and bears the potential to significantly reduce the number of needed invasive coronary angiographies.
Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Constrição Patológica , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Feminino , Humanos , Aprendizado de Máquina , Masculino , Valor Preditivo dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios XRESUMO
OBJECTIVES: To evaluate the effectiveness of a novel artificial intelligence (AI) algorithm for fully automated measurement of left atrial (LA) volumes and function using cardiac CT in patients with atrial fibrillation. METHODS: We included 79 patients (mean age 63 ± 12 years; 35 with atrial fibrillation (AF) and 44 controls) between 2017 and 2020 in this retrospective study. Images were analyzed by a trained AI algorithm and an expert radiologist. Left atrial volumes were obtained at cardiac end-systole, end-diastole, and pre-atrial contraction, which were then used to obtain LA function indices. Intraclass correlation coefficient (ICC) analysis of the LA volumes and function parameters was performed and receiver operating characteristic (ROC) curve analysis was used to compare the ability to detect AF patients. RESULTS: The AI was significantly faster than manual measurement of LA volumes (4 s vs 10.8 min, respectively). Agreement between the manual and automated methods was good to excellent overall, and there was stronger agreement in AF patients (all ICCs ≥ 0.877; p < 0.001) than controls (all ICCs ≥ 0.799; p < 0.001). The AI comparably estimated LA volumes in AF patients (all within 1.3 mL of the manual measurement), but overestimated volumes by clinically negligible amounts in controls (all by ≤ 4.2 mL). The AI's ability to distinguish AF patients from controls using the LA volume index was similar to the expert's (AUC 0.81 vs 0.82, respectively; p = 0.62). CONCLUSION: The novel AI algorithm efficiently performed fully automated multiphasic CT-based quantification of left atrial volume and function with similar accuracy as compared to manual quantification. Novel CT-based AI algorithm efficiently quantifies left atrial volumes and function with similar accuracy as manual quantification in controls and atrial fibrillation patients. KEY POINTS: ⢠There was good-to-excellent agreement between manual and automated methods for left atrial volume quantification. ⢠The AI comparably estimated LA volumes in AF patients, but overestimated volumes by clinically negligible amounts in controls. ⢠The AI's ability to distinguish AF patients from controls was similar to the manual methods.
Assuntos
Fibrilação Atrial , Idoso , Inteligência Artificial , Fibrilação Atrial/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodosRESUMO
BACKGROUND. Deep learning-based convolutional neural networks have enabled major advances in development of artificial intelligence (AI) software applications. Modern AI applications offer comprehensive multiorgan evaluation. OBJECTIVE. The purpose of this article was to evaluate the impact of an automated AI platform integrated into clinical workflow for chest CT interpretation on radiologists' interpretation times when evaluated in a real-world clinical setting. METHODS. In this prospective single-center study, a commercial AI software solution was integrated into clinical workflow for chest CT interpretation. The software provided automated analysis of cardiac, pulmonary, and musculoskeletal findings, including labeling, segmenting, and measuring normal structures as well as detecting, labeling, and measuring abnormalities. AI-annotated images and autogenerated summary results were stored in the PACS and available to interpreting radiologists. A total of 390 patients (204 women, 186 men; mean age, 62.8 ± 13.3 [SD] years) who underwent out-patient chest CT between January 19, 2021, and January 28, 2021, were included. Scans were randomized using 1:1 allocation between AI-assisted and non-AI-assisted arms and were clinically interpreted by one of three cardiothoracic radiologists (65 scans per arm per radiologist; total of 195 scans per arm) who recorded interpretation times using a stopwatch. Findings were categorized according to review of report impressions. Interpretation times were compared between arms. RESULTS. Mean interpretation times were significantly shorter in the AI-assisted than in the non-AI-assisted arm for all three readers (289 ± 89 vs 344 ± 129 seconds, p < .001; 449 ± 110 vs 649 ± 82 seconds, p < .001; 281 ± 114 vs 348 ± 93 seconds, p = .01) and for readers combined (328 ± 122 vs 421 ± 175 seconds, p < .001). For readers combined, the mean difference was 93 seconds (95% CI, 63-123 seconds), corresponding with a 22.1% reduction in the AI-assisted arm. Mean interpretation time was also shorter in the AI-assisted arm compared with the non-AI-assisted arm for contrast-enhanced scans (83 seconds), noncontrast scans (104 seconds), negative scans (84 seconds), positive scans without significant new findings (117 seconds), and positive scans with significant new findings (92 seconds). CONCLUSION. Cardiothoracic radiologists exhibited a 22.1% reduction in chest CT interpretations times when they had access to results from an automated AI support platform during real-world clinical practice. CLINICAL IMPACT. Integration of the AI support platform into clinical workflow improved radiologist efficiency.
Assuntos
Inteligência Artificial , Tomografia Computadorizada por Raios X , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Radiologistas , Redes Neurais de Computação , Estudos RetrospectivosRESUMO
BACKGROUND. Cardiac CTA is required for preprocedural workup before transcatheter aortic valve replacement (TAVR) and can be used to assess functional parameters of the left atrium (LA). OBJECTIVE. We aimed to evaluate the utility of functional and volumetric LA parameters derived from cardiac CTA to predict mortality in patients with severe aortic stenosis (AS) undergoing TAVR. METHODS. This retrospective study included 175 patients with severe AS (92 men, 83 women; median age, 79.0 years) who underwent cardiac CTA for clinical pre-TAVR assessment. A postdoctoral research fellow calculated maximum and minimum LA volumes using biplane area-length measurements; these values were indexed to body surface area, and maximum and minimum LA volume index (LAVImax and LAVImin, respectively) values were calculated. The LA emptying fraction (LAEF) was automatically calculated. All-cause mortality within a 24-month follow-up period after TAVR was recorded. To identify parameters predictive of mortality, Cox regression analysis was performed, and results were summarized by hazard ratio (HR) and 95% CI. The Harrell C-index was used to assess model performance. A radiology resident repeated the measurements in a random sample of 20% (n = 35) of the cases, and interobserver agreement was computed using the intraclass correlation coefficient (ICC). RESULTS. Thirty-eight deaths (21.7%) were recorded within a median follow-up of 21 months. LAVImax (HR, 1.02 [95% CI, 1.01-1.04]; p = .01), LAVImin (HR, 1.02 [95% CI, 1.01-1.04]; p < .001), and LAEF (HR, 0.97 [95% CI, 0.95-0.99]; p = .002) were predictive of mortality in univariable analysis. After adjusting for clinical parameters, only LAEF (HR, 0.97 [95% CI, 0.94-0.99]; p = .02) independently predicted mortality. The C-index of the Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) significantly increased from 0.636 to 0.683, 0.694, and 0.700 when incorporating into the model LAVImax, LAVImin, and LAEF, respectively. The ICC for maximum and minimum LA volumes and LAEF ranged from 0.94 to 0.99. CONCLUSION. LAEF derived from preprocedural cardiac CTA independently predicts mortality in patients with severe AS undergoing TAVR. CLINICAL IMPACT. Cardiac CTA-derived LA function, evaluated during pre-TAVR workup, can be used to assess preprocedural risk and may improve risk stratification in post-TAVR surveillance.
Assuntos
Angiografia por Tomografia Computadorizada/métodos , Cuidados Pré-Operatórios/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Retrospectivos , Resultado do TratamentoRESUMO
Radiology: Cardiothoracic Imaging publishes novel research and technical developments in cardiac, thoracic, and vascular imaging. The journal published many innovative studies during 2023 and achieved an impact factor for the first time since its inaugural issue in 2019, with an impact factor of 7.0. The current review article, led by the Radiology: Cardiothoracic Imaging trainee editorial board, highlights the most impactful articles published in the journal between November 2022 and October 2023. The review encompasses various aspects of coronary CT, photon-counting detector CT, PET/MRI, cardiac MRI, congenital heart disease, vascular imaging, thoracic imaging, artificial intelligence, and health services research. Key highlights include the potential for photon-counting detector CT to reduce contrast media volumes, utility of combined PET/MRI in the evaluation of cardiac sarcoidosis, the prognostic value of left atrial late gadolinium enhancement at MRI in predicting incident atrial fibrillation, the utility of an artificial intelligence tool to optimize detection of incidental pulmonary embolism, and standardization of medical terminology for cardiac CT. Ongoing research and future directions include evaluation of novel PET tracers for assessment of myocardial fibrosis, deployment of AI tools in clinical cardiovascular imaging workflows, and growing awareness of the need to improve environmental sustainability in imaging. Keywords: Coronary CT, Photon-counting Detector CT, PET/MRI, Cardiac MRI, Congenital Heart Disease, Vascular Imaging, Thoracic Imaging, Artificial Intelligence, Health Services Research © RSNA, 2024.
Assuntos
Apêndice Atrial , Cardiopatias Congênitas , Radiologia , Humanos , Meios de Contraste , Inteligência Artificial , Gadolínio , Tomografia Computadorizada por Raios XRESUMO
BACKGROUND: Radiomics is not yet used in clinical practice due to concerns regarding its susceptibility to technical factors. We aimed to assess the stability and interscan and interreader reproducibility of myocardial radiomic features between energy-integrating detector computed tomography (EID-CT) and photon-counting detector CT (PCD-CT) in patients undergoing coronary CT angiography (CCTA) on both systems. METHODS: Consecutive patients undergoing clinically indicated CCTA on an EID-CT were prospectively enrolled for a PCD-CT CCTA within 30 days. Virtual monoenergetic images (VMI) at various keV levels and polychromatic images (T3D) were generated for PCD-CT, with image reconstruction parameters standardized between scans. Two readers performed myocardial segmentation and 110 radiomic features were compared intraindividually between EID-CT and PDC-CT series. The agreement of parameters was assessed using the intraclass correlation coefficient and paired t-test for the stability of the parameters. RESULTS: Eighteen patients (15 males) aged 67.6 ± 9.7 years (mean ± standard deviation) were included. Besides polychromatic PCD-CT reconstructions, 60- and 70-keV VMIs showed the highest feature stability compared to EID-CT (96%, 90%, and 92%, respectively). The interscan reproducibility of features was moderate even in the most favorable comparisons (median ICC 0.50 [interquartile range 0.20-0.60] for T3D; 0.56 [0.33-0.74] for 60 keV; 0.50 [0.36-0.62] for 70 keV). Interreader reproducibility was excellent for the PCD-CT series and good for EID-CT segmentations. CONCLUSION: Most myocardial radiomic features remain stable between EID-CT and PCD-CT. While features demonstrated moderate reproducibility between scanners, technological advances associated with PCD-CT may lead to greater reproducibility, potentially expediting future standardization efforts. RELEVANCE STATEMENT: While the use of PCD-CT may facilitate reduced interreader variability in radiomics analysis, the observed interscanner variations in comparison to EID-CT should be taken into account in future research, with efforts being made to minimize their impact in future radiomics studies. KEY POINTS: Most myocardial radiomic features resulted in being stable between EID-CT and PCD-CT on certain VMIs. The reproducibility of parameters between detector technologies was limited. PCD-CT improved interreader reproducibility of myocardial radiomic features.
Assuntos
Angiografia por Tomografia Computadorizada , Humanos , Masculino , Feminino , Idoso , Reprodutibilidade dos Testes , Angiografia por Tomografia Computadorizada/métodos , Estudos Prospectivos , Fótons , Angiografia Coronária/métodos , Pessoa de Meia-Idade , RadiômicaRESUMO
PURPOSE: To evaluate a novel deep learning (DL)-based automated coronary labeling approach for structured reporting of coronary artery disease according to the guidelines of the Society of Cardiovascular Computed Tomography (CT) on coronary CT angiography (CCTA). PATIENTS AND METHODS: A retrospective cohort of 104 patients (60.3 ± 10.7 y, 61% males) who had undergone prospectively electrocardiogram-synchronized CCTA were included. Coronary centerlines were automatically extracted, labeled, and validated by 2 expert readers according to Society of Cardiovascular CT guidelines. The DL algorithm was trained on 706 radiologist-annotated cases for the task of automatically labeling coronary artery centerlines. The architecture leverages tree-structured long short-term memory recurrent neural networks to capture the full topological information of the coronary trees by using a two-step approach: a bottom-up encoding step, followed by a top-down decoding step. The first module encodes each sub-tree into fixed-sized vector representations. The decoding module then selectively attends to the aggregated global context to perform the local assignation of labels. To assess the performance of the software, percentage overlap was calculated between the labels of the algorithm and the expert readers. RESULTS: A total number of 1491 segments were identified. The artificial intelligence-based software approach yielded an average overlap of 94.4% compared with the expert readers' labels ranging from 87.1% for the posterior descending artery of the right coronary artery to 100% for the proximal segment of the right coronary artery. The average computational time was 0.5 seconds per case. The interreader overlap was 96.6%. CONCLUSIONS: The presented fully automated DL-based coronary artery labeling algorithm provides fast and precise labeling of the coronary artery segments bearing the potential to improve automated structured reporting for CCTA.
Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Aprendizado Profundo , Masculino , Humanos , Feminino , Angiografia por Tomografia Computadorizada/métodos , Inteligência Artificial , Estudos Retrospectivos , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Doença da Artéria Coronariana/diagnóstico por imagemRESUMO
BACKGROUND: The potential role of cardiac computed tomography (CT) has increasingly been demonstrated for the assessment of diffuse myocardial fibrosis through the quantification of extracellular volume (ECV). Photon-counting detector (PCD)-CT technology may deliver more accurate ECV quantification compared to energy-integrating detector CT. We evaluated the impact of reconstruction settings on the accuracy of ECV quantification using PCD-CT, with magnetic resonance imaging (MRI)-based ECV as reference. METHODS: In this post hoc analysis, 27 patients (aged 53.1 ± 17.2 years (mean ± standard deviation); 14 women) underwent same-day cardiac PCD-CT and MRI. Late iodine CT scans were reconstructed with different quantum iterative reconstruction levels (QIR 1-4), slice thicknesses (0.4-8 mm), and virtual monoenergetic imaging levels (VMI, 40-90 keV); ECV was quantified for each reconstruction setting. Repeated measures ANOVA and t-test for pairwise comparisons, Bland-Altman plots, and Lin's concordance correlation coefficient (CCC) were used. RESULTS: ECV values did not differ significantly among QIR levels (p = 1.000). A significant difference was observed throughout different slice thicknesses, with 0.4 mm yielding the highest agreement with MRI-based ECV (CCC = 0.944); 45-keV VMI reconstructions showed the lowest mean bias (0.6, 95% confidence interval 0.1-1.4) compared to MRI. Using the most optimal reconstruction settings (QIR4. slice thickness 0.4 mm, VMI 45 keV), a 63% reduction in mean bias and a 6% increase in concordance with MRI-based ECV were achieved compared to standard settings (QIR3, slice thickness 1.5 mm; VMI 65 keV). CONCLUSIONS: The selection of appropriate reconstruction parameters improved the agreement between PCD-CT and MRI-based ECV. RELEVANCE STATEMENT: Tailoring PCD-CT reconstruction parameters optimizes ECV quantification compared to MRI, potentially improving its clinical utility. KEY POINTS: ⢠CT is increasingly promising for myocardial tissue characterization, assessing focal and diffuse fibrosis via late iodine enhancement and ECV quantification, respectively. ⢠PCD-CT offers superior performance over conventional CT, potentially improving ECV quantification and its agreement with MRI-based ECV. ⢠Tailoring PCD-CT reconstruction parameters optimizes ECV quantification compared to MRI, potentially improving its clinical utility.
Assuntos
Imageamento por Ressonância Magnética , Miocárdio , Tomografia Computadorizada por Raios X , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Idoso , Fótons , Adulto , Processamento de Imagem Assistida por Computador/métodos , Coração/diagnóstico por imagemRESUMO
RATIONALE AND OBJECTIVES: Coronary CT angiography (CCTA) is mandatory before transcatheter aortic valve replacement (TAVR). Our objective was to evaluate the efficacy of artificial intelligence (AI)-powered software in automatically analyzing cardiac parameters from pre-procedural CCTA to predict major adverse cardiovascular events (MACE) in TAVR patients. MATERIALS AND METHODS: Patients undergoing pre-TAVR CCTA were retrospectively included. AI software automatically extracted 34 morphologic and volumetric cardiac parameters characterizing the ventricles, atria, myocardium, and epicardial adipose tissue. Clinical information and outcomes were recorded from institutional database. Cox regression analysis identified predictors of MACE, including non-fatal myocardial infarction, heart failure hospitalization, unstable angina, and cardiac death. Model performance was evaluated with Harrell's C-index, and nested models were compared using the likelihood ratio test. Manual analysis of 170 patients assessed agreement with automated measurements. RESULTS: Among the 648 enrolled patients (77 ± 9.3 years, 58.9% men), 116 (17.9%) experienced MACE within a median follow-up of 24 months (interquartile range 10-40). After adjusting for clinical parameters, only left ventricle long axis shortening (LV-LAS) was an independent predictor of MACE (hazard ratio [HR], 1.05 [95% confidence interval, 1.05-1.11]; p = 0.04), with significantly improved C-index (0.620 vs. 0.633; p < 0.001). When adjusted for the Society of Thoracic Surgeons Predicted Risk of Mortality score, LV-LAS was also predictive of MACE (HR, 1.08 [95%CI, 1.03-1.13]; p = 0.002), while improving model performance (C-index: 0.557 vs. 0.598; p < 0.001). All parameters showed good or excellent agreement with manual measurements. CONCLUSION: Automated AI-based comprehensive cardiac assessment enables pre-TAVR MACE prediction, with LV-LAS outperforming all other parameters.
RESUMO
Since its inaugural issue in 2019, Radiology: Cardiothoracic Imaging has disseminated the latest scientific advances and technical developments in cardiac, vascular, and thoracic imaging. In this review, we highlight select articles published in this journal between October 2021 and October 2022. The scope of the review encompasses various aspects of coronary artery and congenital heart diseases, vascular diseases, thoracic imaging, and health services research. Key highlights include changes in the revised Coronary Artery Disease Reporting and Data System 2.0, the value of coronary CT angiography in informing prognosis and guiding treatment decisions, cardiac MRI findings after COVID-19 vaccination or infection, high-risk features at CT angiography to identify patients with aortic dissection at risk for late adverse events, and CT-guided fiducial marker placement for preoperative planning for pulmonary nodules. Ongoing research and future directions include photon-counting CT and artificial intelligence applications in cardiovascular imaging. Keywords: Pediatrics, CT Angiography, CT-Perfusion, CT-Spectral Imaging, MR Angiography, PET/CT, Transcatheter Aortic Valve Implantation/Replacement (TAVI/TAVR), Cardiac, Pulmonary, Vascular, Aorta, Coronary Arteries © RSNA, 2023.
RESUMO
PURPOSE: To intra-individually compare the objective and subjective image quality of coronary computed tomography angiography (CCTA) between photon-counting detector CT (PCD-CT) and energy-integrating detector CT (EID-CT). METHOD: Consecutive patients undergoing clinically indicated CCTA on an EID-CT system were prospectively enrolled for a research CCTA performed on a PCD-CT system within 30 days. Polychromatic images were reconstructed for both EID- and PCD-CT, while virtual monoenergetic images (VMI) were generated at 40, 45, 50, 55, 60 and 70 keV for PCD-CT. Two blinded readers calculated contrast-to-noise ratio (CNR) for each major coronary artery and rated image noise, vessel attenuation, vessel sharpness, and overall quality on a 1-5 Likert scale. Patients were then stratified by body mass index (BMI) [high (>30 kg/m2) vs low (<30 kg/m2)] for subgroup analysis. RESULTS: A total of 20 patients (67.5 ± 9.0 years, 75% male) were included in the study. Compared with EID-CT, coronary artery CNR values from PCD-CT monoenergetic and polychromatic reconstructions were all significantly higher than CNR values from EID-CT, with incrementally greater differences in obese subjects (all p < 0.008). Subjective image noise and sharpness were also significantly higher for all VMI reconstructions compared to EID-CT (all p < 0.008). All subjective scores were significantly higher for 55, 60, and 70 keV PCD-CT than EID-CT values (all p < 0.05). CONCLUSIONS: The improved objective and subjective image quality of PCD-CT compared to EID-CT may provide better visualization of the coronary arteries for a wide array of patients, especially those with a high BMI.
Assuntos
Vasos Coronários , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada/métodos , Coração , Fótons , Imagens de FantasmasRESUMO
Background: The purpose of this study was to develop and validate reliable computed tomography (CT) imaging criteria for the diagnosis of gastric band slippage. Material and Methods: We retrospectively evaluated 67 patients for gastric band slippage using CT. Of these, 14 had surgically proven gastric band slippage (study group), 22 had their gastric bands removed for reasons other than slippage (control group 1), and 31 did not require removal (control group 2). All of the studies were read independently by two radiologists in a blinded fashion. The "O" sign, phi angle, amount of inferior displacement from the esophageal hiatus, and gastric pouch size were used to create CT diagnostic criteria. Standard statistical methods were used. Results: There was good overall interobserver agreement for diagnosis of gastric band slippage using CT diagnostic criteria (kappa = 0.83). Agreement was excellent for the "O" sign (kappa = 0.93) and phi angle (intraclass correlation coefficient = 0.976). The "O" sign, inferior displacement from the hiatus >3.5 cm, and gastric pouch volume >55 cm3 each had 100% positive predictive value. A phi angle <20° or >60° had the highest negative predictive value (NPV) (98%). Of all CT diagnostic criteria, enlarged gastric pouch size was most correlated with band slippage with an AUC of 0.991. Conclusion: All four imaging parameters were useful in evaluating for gastric band slippage on CT, with good interobserver agreement. Of these parameters, enlarged gastric pouch size was most correlated with slippage and abnormal phi angle had the highest NPV.
RESUMO
PURPOSE: The purpose of this study was to determine whether EAT volume in combination with coronary CT angiography (CCTA)-derived plaque quantification and CT-derived fractional flow reserve (CT-FFR) has prognostic implication with major adverse cardiac events (MACE). METHODS: Patients (n = 117, 58 ± 10 years, 61% male) who had previously undergone invasive coronary angiography (ICA) and CCTA were retrospectively analyzed. Follow-up was performed to record MACE. EAT volume and plaque measures were derived from non-contrast and contrast-enhanced CT images using a semi-automatic software approach, while CT-FFR was calculated using a machine-learning algorithm. The diagnostic performance to identify MACE was evaluated using univariable and multivariable Cox proportional hazards analysis and concordance (C)-indices. RESULTS: During a median follow-up period of 40.4 months, 19 events were registered. EAT volume, CCTA ≥ 50% stenosis, and CT-FFR were significantly different in patients developing MACE (all p < 0.05). The following parameters were predictors of MACE in adjusted multivariable Cox regression analysis (hazard ratio [HR]): EAT volume (HR 2.21, p = 0.023), indexed EAT volume (HR 2.03, p = 0.035), and CCTA ≥ 50% (HR 1.05, p = 0.048). A model including Morise score, CCTA ≥ 50% stenosis, and EAT volume showed significantly improved C-index to Morise score alone (AUC 0.83 vs. 0.66, p = 0.004). CONCLUSIONS: Facing limitations in conventional cardiovascular risk scoring models, this observational study demonstrates that the prediction performance of our proposed method achieves a significant improvement in prognostic ability, especially when compared to models such as Morise score alone or its combination with CCTA and CT-FFR.
Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Tecido Adiposo/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Prognóstico , Estudos RetrospectivosRESUMO
Purpose: To evaluate the value of using left ventricular (LV) long-axis shortening (LAS) derived from coronary CT angiography (CCTA) to predict mortality in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). Materials and Methods: Patients with severe AS who underwent CCTA for preprocedural TAVR planning between September 2014 and December 2019 were included in this retrospective study. CCTA covered the whole cardiac cycle in 10% increments. Image series reconstructed at end systole and end diastole were used to measure LV-LAS. All-cause mortality within 24 months of follow-up after TAVR was recorded. Cox regression analysis was performed, and hazard ratios (HRs) are presented with 95% CIs. The C index was used to evaluate model performance, and the likelihood ratio χ2 test was performed to compare nested models. Results: The study included 175 patients (median age, 79 years [IQR, 73-85 years]; 92 men). The mortality rate was 22% (38 of 175). When adjusting for predictive clinical confounders, it was found that LV-LAS could be used independently to predict mortality (adjusted HR, 2.83 [95% CI: 1.13, 7.07]; P = .03). In another model using the Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM), LV-LAS remained significant (adjusted HR, 3.38 [95 CI: 1.48, 7.72]; P = .004), and its use improved the predictive value of the STS-PROM, increasing the STS-PROM C index from 0.64 to 0.71 (χ2 = 29.9 vs 19.7, P = .001). In a subanalysis of patients with a normal LV ejection fraction (LVEF), the significance of LV-LAS persisted (adjusted HR, 3.98 [95 CI: 1.56, 10.17]; P = .004). Conclusion: LV-LAS can be used independently to predict mortality in patients undergoing TAVR, including those with a normal LVEF.Keywords: CT Angiography, Transcatheter Aortic Valve Implantation/Replacement (TAVI/TAVR), Cardiac, Outcomes Analysis, Cardiomyopathies, Left Ventricle, Aortic Valve Supplemental material is available for this article. © RSNA, 2022See also the commentary by Everett and Leipsic in this issue.
RESUMO
OBJECTIVES: We aimed to validate and test a prototype algorithm for automated dual-energy computed tomography (DECT)-based myocardial extracellular volume (ECV) assessment in patients with various cardiomyopathies. METHODS: This retrospective study included healthy subjects (n=9; 61±10 y) and patients with cardiomyopathy (n=109, including a validation cohort n=60; 68±9 y; and a test cohort n=49; 69±11 y), who had previously undergone cardiac DECT. Myocardial ECV was calculated using a prototype-based fully automated algorithm and compared with manual assessment. Receiver-operating characteristic analysis was performed to test the algorithm's ability to distinguish healthy subjects and patients with cardiomyopathy. RESULTS: The fully automated method led to a significant reduction of postprocessing time compared with manual assessment (2.2±0.4 min and 9.4±0.7 min, respectively, P <0.001). There was no significant difference in ECV between the automated and manual methods ( P =0.088). The automated method showed moderate correlation and agreement with the manual technique ( r =0.68, intraclass correlation coefficient=0.66). ECV was significantly higher in patients with cardiomyopathy compared with healthy subjects, regardless of the method used ( P <0.001). In the test cohort, the automated method yielded an area under the curve of 0.98 for identifying patients with cardiomyopathies. CONCLUSION: Automated ECV estimation based on DECT showed moderate agreement with the manual method and matched with previously reported ECV values for healthy volunteers and patients with cardiomyopathy. The automatically derived ECV demonstrated an excellent diagnostic performance to discriminate between healthy and diseased myocardium, suggesting that it could be an effective initial screening tool while significantly reducing the time of assessment.
Assuntos
Cardiomiopatias , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatias/diagnóstico por imagem , Meios de Contraste , Fibrose , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Miocárdio/patologia , Valor Preditivo dos Testes , Estudos Retrospectivos , TomografiaRESUMO
OBJECTIVES: The aim of the study is to investigate the performance of artificial intelligence (AI) convolutional neural networks (CNN) in detecting lung nodules on chest computed tomography of patients with complex lung disease, and demonstrate its noninferiority when compared against an experienced radiologist through clinically relevant assessments. METHODS: A CNN prototype was used to retrospectively evaluate 103 complex lung disease cases and 40 control cases without reported nodules. Computed tomography scans were blindly evaluated by an expert thoracic radiologist; a month after initial analyses, 20 positive cases were re-evaluated with the assistance of AI. For clinically relevant applications: (1) AI was asked to classify each patient into nodules present or absent and (2) AI results were compared against standard radiology reports. Standard statistics were performed to determine detection performance. RESULTS: AI was, on average, 27 seconds faster than the expert and detected 8.4% of nodules that would have been missed. AI had a sensitivity of 67.7%, similar to an accuracy reported for experienced radiologists. AI correctly classified each patient (nodules present/absent) with a sensitivity of 96.1%. When matched against radiology reports, AI performed with a sensitivity of 89.4%. Control group assessment demonstrated an overall specificity of 82.5%. When aided by AI, the expert decreased the average assessment time per case from 2:44 minutes to 35.7 seconds, while reporting an overall increase in confidence. CONCLUSION: In a group of patients with complex lung disease, the sensitivity of AI is similar to an experienced radiologist and the tool helps detect previously missed nodules. AI also helps experts analyze for lung nodules faster and more confidently, a feature that is beneficial to patients and favorable to hospitals due to increased patient load and need for shorter turnaround times.
Assuntos
Neoplasias Pulmonares , Nódulo Pulmonar Solitário , Inteligência Artificial , Humanos , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e EspecificidadeRESUMO
OBJECTIVES: To investigate the predictive value of right ventricular long axis strain (RV-LAS) derived by cardiac computed tomography angiography (CCTA) for mortality in patients with aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). METHODS: We retrospectively included patients with severe AS undergoing TAVR (n = 168, median 79 years). Parameters of RV function including RV-LAS and RV ejection fraction (RVEF) were assessed using pre-procedural systolic and diastolic CCTA series. The tricuspid annulus diameter (TAD) and diameter of the main pulmonary artery (mPA) were also assessed. All-cause mortality was recorded post-TAVR. Cox regression was used and results are presented with hazard ratio (HR) and 95% confidence interval (CI). Harrell's c-index was used to assess the performance of different models and the likelihood ratio test was used to compare nested models. RESULTS: Thirty-eight deaths (22.6%) occurred over a median follow-up of 21 months. RV-LAS > -11.42% (HR 2.86, 95% CI 1.44-5.67, p = 0.003), LVEF (HR 0.98, 95% CI 0.96-0.996; p = 0.02), TAD (HR 1.05, 95% CI 1.01-1.10, p = 0.02) and mPA diameter (HR 1.09, 95% CI 1.02-1.16, p = 0.01) were associated with mortality on univariable analysis. In a multivariable model, only RV-LAS (HR 2.36, 95% CI 1.04-5.36, p = 0.04) remained as an independent predictor of all-cause mortality. RV-LAS significantly improved the predictive power of the Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) (c-index 0.700 vs 0.637; p = 0.01). CONCLUSION: RV-LAS was an independent predictor of all-cause mortality in patients with severe AS undergoing TAVR, outperformed anatomical markers such as TAD and mPA diameter, and could potentially improve the current risk-stratifying tool.