RESUMO
We describe deep analysis of the human proteome in less than 1 h. We achieve this expedited proteome characterization by leveraging state-of-the-art sample preparation, chromatographic separations, and data analysis tools, and by using the new Orbitrap Astral mass spectrometer equipped with a quadrupole mass filter, a high-field Orbitrap mass analyzer, and an asymmetric track lossless (Astral) mass analyzer. The system offers high tandem mass spectrometry acquisition speed of 200 Hz and detects hundreds of peptide sequences per second within data-independent acquisition or data-dependent acquisition modes of operation. The fast-switching capabilities of the new quadrupole complement the sensitivity and fast ion scanning of the Astral analyzer to enable narrow-bin data-independent analysis methods. Over a 30-min active chromatographic method consuming a total analysis time of 56 min, the Q-Orbitrap-Astral hybrid MS collects an average of 4319 MS1 scans and 438,062 tandem mass spectrometry scans per run, producing 235,916 peptide sequences (1% false discovery rate). On average, each 30-min analysis achieved detection of 10,411 protein groups (1% false discovery rate). We conclude, with these results and alongside other recent reports, that the 1-h human proteome is within reach.
Assuntos
Proteoma , Proteômica , Espectrometria de Massas em Tandem , Humanos , Proteoma/análise , Proteômica/métodos , Fatores de TempoRESUMO
Clinical biomarker development has been stymied by inaccurate protein quantification from mass spectrometry (MS) discovery data and a prolonged validation process. To mitigate these issues, we created the Targeted Extraction Assessment of Quantification (TEAQ) software package that uses data-independent acquisition analysis from a discovery cohort to select precursors, peptides, and proteins that adhere to analytical criteria required for established targeted assays. TEAQ was applied to DIA-MS data from plasma samples acquired on a new high resolution accurate mass (HRAM) mass spectrometry platform where precursors were evaluated for linearity, specificity, repeatability, reproducibility, and intra-protein correlation based on 8- or 11-point loading curves at three throughputs. This data can be used as a general resource for developing other targeted assays. TEAQ analysis of data from a case and control cohort for inflammatory bowel disease (n=492) identified 1110 signature peptides for 326 quantifiable proteins from the 1179 identified proteins. Applying TEAQ analysis to discovery data will streamline targeted assay development and the transition to validation and clinical studies.
RESUMO
We evaluate the quantitative performance of the newly released Asymmetric Track Lossless (Astral) analyzer. Using data-independent acquisition, the Thermo Scientific Orbitrap Astral mass spectrometer quantifies 5 times more peptides per unit time than state-of-the-art Thermo Scientific Orbitrap mass spectrometers, which have long been the gold standard for high-resolution quantitative proteomics. Our results demonstrate that the Orbitrap Astral mass spectrometer can produce high-quality quantitative measurements across a wide dynamic range. We also use a newly developed extracellular vesicle enrichment protocol to reach new depths of coverage in the plasma proteome, quantifying over 5000 plasma proteins in a 60 min gradient with the Orbitrap Astral mass spectrometer.
Assuntos
Peptídeos , Proteômica , Proteômica/métodos , Espectrometria de Massas/métodos , Proteoma/metabolismo , Proteínas SanguíneasRESUMO
The growing trend toward high-throughput proteomics demands rapid liquid chromatography-mass spectrometry (LC-MS) cycles that limit the available time to gather the large numbers of MS/MS fragmentation spectra required for identification. Orbitrap analyzers scale performance with acquisition time and necessarily sacrifice sensitivity and resolving power to deliver higher acquisition rates. We developed a new mass spectrometer that combines a mass-resolving quadrupole, the Orbitrap, and the novel Asymmetric Track Lossless (Astral) analyzer. The new hybrid instrument enables faster acquisition of high-resolution accurate mass (HRAM) MS/MS spectra compared with state-of-the-art mass spectrometers. Accordingly, new proteomics methods were developed that leverage the strengths of each HRAM analyzer, whereby the Orbitrap analyzer performs full scans with a high dynamic range and resolution, synchronized with the Astral analyzer's acquisition of fast and sensitive HRAM MS/MS scans. Substantial improvements are demonstrated over previous methods using current state-of-the-art mass spectrometers.
RESUMO
State-of-the-art proteomics-grade mass spectrometers can measure peptide precursors and their fragments with ppm mass accuracy at sequencing speeds of tens of peptides per second with attomolar sensitivity. Here we describe a compact and robust quadrupole-orbitrap mass spectrometer equipped with a front-end High Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS) Interface. The performance of the Orbitrap Exploris 480 mass spectrometer is evaluated in data-dependent acquisition (DDA) and data-independent acquisition (DIA) modes in combination with FAIMS. We demonstrate that different compensation voltages (CVs) for FAIMS are optimal for DDA and DIA, respectively. Combining DIA with FAIMS using single CVs, the instrument surpasses 2500 peptides identified per minute. This enables quantification of >5000 proteins with short online LC gradients delivered by the Evosep One LC system allowing acquisition of 60 samples per day. The raw sensitivity of the instrument is evaluated by analyzing 5 ng of a HeLa digest from which >1000 proteins were reproducibly identified with 5 min LC gradients using DIA-FAIMS. To demonstrate the versatility of the instrument, we recorded an organ-wide map of proteome expression across 12 rat tissues quantified by tandem mass tags and label-free quantification using DIA with FAIMS to a depth of >10,000 proteins.
Assuntos
Espectrometria de Mobilidade Iônica , Espectrometria de Massas , Proteoma/metabolismo , Animais , Cromatografia Líquida , Células HeLa , Humanos , Masculino , Fases de Leitura Aberta/genética , Especificidade de Órgãos , Peptídeos/metabolismo , Fosfopeptídeos/metabolismo , Fosfoproteínas/metabolismo , Proteômica , Ratos Sprague-DawleyRESUMO
Although current LC-MS technology permits scientists to efficiently screen clinical samples in translational research, e.g., steroids, biogenic amines, and even plasma or serum proteomes, in a daily routine, maintaining the balance between throughput and analytical depth is still a limiting factor. A typical approach to enhance the proteome depth is employing offline two-dimensional (2D) fractionation techniques before reversed-phase nanoLC-MS/MS analysis (1D-nanoLC-MS). These additional sample preparation steps usually require extensive sample manipulation, which could result in sample alteration and sample loss. Here, we present and compare 1D-nanoLC-MS with an automated online-2D high-pH RP × low pH RP separation method for deep proteome profiling using a nanoLC system coupled to a high-resolution accurate-mass mass spectrometer. The proof-of-principle study permitted the identification of ca. 500 proteins with â¼10,000 peptides in 15 enzymatically digested crude serum samples collected from healthy donors in 3 laboratories across Europe. The developed method identified 60% more peptides in comparison with conventional 1D nanoLC-MS/MS analysis with ca. 4 times lower throughput while retaining the quantitative information. Serum sample preparation related changes were revealed by applying unsupervised classification techniques and, therefore, must be taken into account while planning multicentric biomarker discovery and validation studies. Overall, this novel method reduces sample complexity and boosts the number of peptide and protein identifications without the need for extra sample handling procedures for samples equivalent to less than 1 µL of blood, which expands the space for potential biomarker discovery by looking deeper into the composition of biofluids.
Assuntos
Proteoma , Espectrometria de Massas em Tandem , Cromatografia Líquida , Proteômica , Manejo de EspécimesRESUMO
Fast identification of microbial species in clinical samples is essential to provide an appropriate antibiotherapy to the patient and reduce the prescription of broad-spectrum antimicrobials leading to antibioresistances. MALDI-TOF-MS technology has become a tool of choice for microbial identification but has several drawbacks: it requires a long step of bacterial culture before analysis (≥24 h), has a low specificity and is not quantitative. We developed a new strategy for identifying bacterial species in urine using specific LC-MS/MS peptidic signatures. In the first training step, libraries of peptides are obtained on pure bacterial colonies in DDA mode, their detection in urine is then verified in DIA mode, followed by the use of machine learning classifiers (NaiveBayes, BayesNet and Hoeffding tree) to define a peptidic signature to distinguish each bacterial species from the others. Then, in the second step, this signature is monitored in unknown urine samples using targeted proteomics. This method, allowing bacterial identification in less than 4 h, has been applied to fifteen species representing 84% of all Urinary Tract Infections. More than 31,000 peptides in 190 samples were quantified by DIA and classified by machine learning to determine an 82 peptides signature and build a prediction model. This signature was validated for its use in routine using Parallel Reaction Monitoring on two different instruments. Linearity and reproducibility of the method were demonstrated as well as its accuracy on donor specimens. Within 4h and without bacterial culture, our method was able to predict the predominant bacteria infecting a sample in 97% of cases and 100% above the standard threshold. This work demonstrates the efficiency of our method for the rapid and specific identification of the bacterial species causing UTI and could be extended in the future to other biological specimens and to bacteria having specific virulence or resistance factors.
Assuntos
Bactérias/classificação , Proteínas de Bactérias/urina , Bacteriúria/urina , Cromatografia Líquida/métodos , Aprendizado de Máquina , Espectrometria de Massas em Tandem/métodos , Bactérias/isolamento & purificação , Humanos , Peptídeos/urina , Proteômica , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por MatrizRESUMO
Progress in proteomics is mainly driven by advances in mass spectrometric (MS) technologies. Here we benchmarked the performance of the latest MS instrument in the benchtop Orbitrap series, the Q Exactive HF-X, against its predecessor for proteomics applications. A new peak-picking algorithm, a brighter ion source, and optimized ion transfers enable productive MS/MS acquisition above 40 Hz at 7500 resolution. The hardware and software improvements collectively resulted in improved peptide and protein identifications across all comparable conditions, with an increase of up to 50 percent at short LC-MS gradients, yielding identification rates of more than 1000 unique peptides per minute. Alternatively, the Q Exactive HF-X is capable of achieving the same proteome coverage as its predecessor in approximately half the gradient time or at 10-fold lower sample loads. The Q Exactive HF-X also enables rapid phosphoproteomics with routine analysis of more than 5000 phosphopeptides with short single-shot 15 min LC-MS/MS measurements, or 16â¯700 phosphopeptides quantified across ten conditions in six gradient hours using TMT10-plex and offline peptide fractionation. Finally, exciting perspectives for data-independent acquisition are highlighted with reproducible identification of 55â¯000 unique peptides covering 5900 proteins in half an hour of MS analysis.
Assuntos
Proteômica/métodos , Espectrometria de Massas em Tandem/instrumentação , Algoritmos , Humanos , Fosfopeptídeos/análise , Proteômica/instrumentação , Espectrometria de Massas em Tandem/métodos , Fatores de TempoRESUMO
The hallmarks of Alzheimer's disease (AD) are characterized by cognitive decline and behavioral changes. The most prominent brain region affected by the progression of AD is the hippocampal formation. The pathogenesis involves a successive loss of hippocampal neurons accompanied by a decline in learning and memory consolidation mainly attributed to an accumulation of senile plaques. The amyloid precursor protein (APP) has been identified as precursor of Aß-peptides, the main constituents of senile plaques. Until now, little is known about the physiological function of APP within the central nervous system. The allocation of APP to the proteome of the highly dynamic presynaptic active zone (PAZ) highlights APP as a yet unknown player in neuronal communication and signaling. In this study, we analyze the impact of APP deletion on the hippocampal PAZ proteome. The native hippocampal PAZ derived from APP mouse mutants (APP-KOs and NexCreAPP/APLP2-cDKOs) was isolated by subcellular fractionation and immunopurification. Subsequently, an isobaric labeling was performed using TMT6 for protein identification and quantification by high-resolution mass spectrometry. We combine bioinformatics tools and biochemical approaches to address the proteomics dataset and to understand the role of individual proteins. The impact of APP deletion on the hippocampal PAZ proteome was visualized by creating protein-protein interaction (PPI) networks that incorporated APP into the synaptic vesicle cycle, cytoskeletal organization, and calcium-homeostasis. The combination of subcellular fractionation, immunopurification, proteomic analysis, and bioinformatics allowed us to identify APP as structural and functional regulator in a context-sensitive manner within the hippocampal active zone network.
Assuntos
Precursor de Proteína beta-Amiloide/metabolismo , Hipocampo/metabolismo , Doença de Alzheimer/etiologia , Doença de Alzheimer/metabolismo , Precursor de Proteína beta-Amiloide/deficiência , Precursor de Proteína beta-Amiloide/genética , Animais , Biologia Computacional , Humanos , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Terminações Pré-Sinápticas/metabolismo , Mapas de Interação de Proteínas , Proteoma/metabolismo , Sinapses/metabolismoRESUMO
Shotgun proteomics is a powerful technology for global analysis of proteins and their post-translational modifications. Here, we investigate the faster sequencing speed of the latest Q Exactive HF mass spectrometer, which features an ultra-high-field Orbitrap mass analyzer. Proteome coverage is evaluated by four different acquisition methods and benchmarked across three generations of Q Exactive instruments (ProteomeXchange data set PXD001305). We find the ultra-high-field Orbitrap mass analyzer to be capable of attaining a sequencing speed above 20 Hz, and it routinely exceeds 10 peptide spectrum matches per second or up to 600 new peptides sequenced per gradient minute. We identify 4400 proteins from 1 µg of HeLa digest using a 1 h gradient, which is an approximately 30% improvement compared to that with previous instrumentation. In addition, we show that very deep proteome coverage can be achieved in less than 24 h of analysis time by offline high-pH reversed-phase peptide fractionation, from which we identify more than 140,000 unique peptide sequences. This is comparable to state-of-the-art multiday, multienzyme efforts. Finally, the acquisition methods are evaluated for single-shot phosphoproteomics, where we identify 7600 unique HeLa phosphopeptides in one gradient hour and find the quality of fragmentation spectra to be more important than quantity for accurate site assignment.
Assuntos
Espectrometria de Massas/métodos , Peptídeos/análise , Proteoma/análise , Proteômica/métodos , Benchmarking/métodos , Fracionamento Químico , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia de Fase Reversa/métodos , Células HeLa , Humanos , Concentração de Íons de Hidrogênio , Peptídeos/metabolismo , Proteoma/metabolismo , Reprodutibilidade dos Testes , Análise de Sequência de Proteína/métodosRESUMO
Clinical biomarker development has been stymied by inaccurate protein quantification from mass spectrometry (MS) discovery data and a prolonged validation process. To mitigate these issues, we created the Targeted Extraction Assessment of Quantification (TEAQ) software package. This innovative tool uses the discovery cohort analysis to select precursors, peptides, and proteins that adhere to established targeted assay criteria. TEAQ was applied to Data-Independent Acquisition MS data from plasma samples acquired on an Orbitrap™ Astral™ MS. Identified precursors were evaluated for linearity, specificity, repeatability, reproducibility, and intra-protein correlation from 11-point loading curves under three throughputs, to develop a resource for clinical-grade targeted assays. From a clinical cohort of individuals with inflammatory bowel disease (n=492), TEAQ successfully identified 1116 signature peptides for 327 quantifiable proteins from 1180 identified proteins. Embedding stringent selection criteria adaptable to targeted assay development into the analysis of discovery data will streamline the transition to validation and clinical studies.
RESUMO
Mass spectrometry (MS)-based proteomics aims to characterize comprehensive proteomes in a fast and reproducible manner. Here we present the narrow-window data-independent acquisition (nDIA) strategy consisting of high-resolution MS1 scans with parallel tandem MS (MS/MS) scans of ~200 Hz using 2-Th isolation windows, dissolving the differences between data-dependent and -independent methods. This is achieved by pairing a quadrupole Orbitrap mass spectrometer with the asymmetric track lossless (Astral) analyzer which provides >200-Hz MS/MS scanning speed, high resolving power and sensitivity, and low-ppm mass accuracy. The nDIA strategy enables profiling of >100 full yeast proteomes per day, or 48 human proteomes per day at the depth of ~10,000 human protein groups in half-an-hour or ~7,000 proteins in 5 min, representing 3× higher coverage compared with current state-of-the-art MS. Multi-shot acquisition of offline fractionated samples provides comprehensive coverage of human proteomes in ~3 h. High quantitative precision and accuracy are demonstrated in a three-species proteome mixture, quantifying 14,000+ protein groups in a single half-an-hour run.
RESUMO
Owing to its roles in cellular signal transduction, protein phosphorylation plays critical roles in myriad cell processes. That said, detecting and quantifying protein phosphorylation has remained a challenge. We describe the use of a novel mass spectrometer (Orbitrap Astral) coupled with data-independent acquisition (DIA) to achieve rapid and deep analysis of human and mouse phosphoproteomes. With this method, we map approximately 30,000 unique human phosphorylation sites within a half-hour of data collection. The technology is benchmarked to other state-of-the-art MS platforms using both synthetic peptide standards and with EGF-stimulated HeLa cells. We apply this approach to generate a phosphoproteome multi-tissue atlas of the mouse. Altogether, we detect 81,120 unique phosphorylation sites within 12 hours of measurement. With this unique dataset, we examine the sequence, structural, and kinase specificity context of protein phosphorylation. Finally, we highlight the discovery potential of this resource with multiple examples of phosphorylation events relevant to mitochondrial and brain biology.
Assuntos
Espectrometria de Massas , Fosfoproteínas , Proteoma , Proteômica , Humanos , Fosfoproteínas/metabolismo , Fosfoproteínas/análise , Animais , Células HeLa , Fosforilação , Camundongos , Proteoma/metabolismo , Espectrometria de Massas/métodos , Proteômica/métodosRESUMO
We evaluate the quantitative performance of the newly released Asymmetric Track Lossless (Astral) analyzer. Using data independent acquisition, the Thermo Scientific™ Orbitrap™ Astral™ mass spectrometer quantifies 5 times more peptides per unit time than state-of-the-art Thermo Scientific™ Orbitrap™ mass spectrometers, which have long been the gold standard for high resolution quantitative proteomics. Our results demonstrate that the Orbitrap Astral mass spectrometer can produce high quality quantitative measurements across a wide dynamic range. We also use a newly developed extra-cellular vesicle enrichment protocol to reach new depths of coverage in the plasma proteome, quantifying over 5,000 plasma proteins in a 60-minute gradient with the Orbitrap Astral mass spectrometer.
RESUMO
Owing to its roles in cellular signal transduction, protein phosphorylation plays critical roles in myriad cell processes. That said, detecting and quantifying protein phosphorylation has remained a challenge. We describe the use of a novel mass spectrometer (Orbitrap Astral) coupled with data-independent acquisition (DIA) to achieve rapid and deep analysis of human and mouse phosphoproteomes. With this method we map approximately 30,000 unique human phosphorylation sites within a half-hour of data collection. We applied this approach to generate a phosphoproteome multi-tissue atlas of the mouse. Altogether, we detected 81,120 unique phosphorylation sites within 12 hours of measurement. With this unique dataset, we examine the sequence and structural context of protein phosphorylation. Finally, we highlight the discovery potential of this resource with multiple examples of novel phosphorylation events relevant to mitochondrial and brain biology.
RESUMO
In the yeast Saccharomyces cerevisiae as in other eukaryotes non-polar lipids are a reservoir of energy and building blocks for membrane lipid synthesis. The yeast non-polar lipids, triacylglycerols (TG) and steryl esters (SE) are stored in so-called lipid particles/droplets (LP) as biologically inert form of fatty acids and sterols. To understand LP structure and function in more detail we investigated the molecular equipment of this compartment making use of mass spectrometric analysis of lipids (TG, SE, phospholipids) and proteins. We addressed the question whether or not lipid and protein composition of LP influence each other and performed analyses of LP from cells grown on two different carbon sources, glucose and oleate. Growth of cells on oleate caused dramatic cellular changes including accumulation of TG at the expense of SE, enhanced the amount of glycerophospholipids and strongly increased the degree of unsaturation in all lipid classes. Most interestingly, oleate as a carbon source led to adaptation of the LP proteome resulting in the appearance of several novel LP proteins. Localization of these new LP proteins was confirmed by cell fractionation. Proteomes of LP variants from cells grown on glucose or oleate, respectively, were compared and are discussed with emphasis on the different groups of proteins detected through this analysis. In summary, we demonstrate flexibility of the yeast LP lipidome and proteome and the ability of LP to adapt to environmental changes.
Assuntos
Regulação Fúngica da Expressão Gênica , Glucose/metabolismo , Metabolismo dos Lipídeos/genética , Ácido Oleico/metabolismo , Fosfolipídeos/metabolismo , Proteínas de Saccharomyces cerevisiae/metabolismo , Saccharomyces cerevisiae/metabolismo , Esteróis/metabolismo , Adaptação Fisiológica , Fracionamento Celular , Cromatografia Líquida de Alta Pressão , Ésteres/análise , Ésteres/metabolismo , Ácidos Graxos/análise , Ácidos Graxos/metabolismo , Perfilação da Expressão Gênica , Glucose/farmacologia , Espectrometria de Massas , Ácido Oleico/farmacologia , Fosfolipídeos/análise , Proteoma/genética , Proteoma/metabolismo , Saccharomyces cerevisiae/genética , Proteínas de Saccharomyces cerevisiae/genética , Esteróis/análise , Triglicerídeos/análise , Triglicerídeos/metabolismoRESUMO
Detergents are frequently used for the solubilization of membrane proteins during and after purification steps. Unfortunately some of these detergents impair chromatographic separations and mass spectrometry (MS) analysis. Perfusion reversed-phase high-performance liquid chromatography (RP-HPLC) using POROS materials is suited for separating intact proteins solubilized by detergents due to the particles' highly diffusive pores and chemical stability. In this article, the use of perfusive reversed-phase material packed into small inner diameter capillary columns is presented as a cheap, rapid, and efficient method for the removal of different types of detergents from protein solutions. The ability to purify and separate the subunits of membrane protein complexes with self-packed capillary columns is exemplified for bovine cytochrome bc(1) complex. Even highly hydrophobic subunits can be detected in collected fractions by intact mass measurements and identified after proteolytic digestion and matrix-assisted laser desorption/ionization tandem MS (MALDI MS/MS). The comparison with a gel-based approach shows that this method is a valuable alternative for purification and separation of intact proteins with subsequent MS analysis and that hydrophobic proteins are even better represented in the LC-based approach.
Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cromatografia de Fase Reversa/métodos , Complexo III da Cadeia de Transporte de Elétrons/isolamento & purificação , Proteínas de Membrana/isolamento & purificação , Subunidades Proteicas/isolamento & purificação , Animais , Bovinos , Cromatografia em Gel , Detergentes/química , Interações Hidrofóbicas e Hidrofílicas , Peso Molecular , Porosidade , Proteólise , Soluções , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por MatrizRESUMO
Owing to its broad biological significance, the large-scale analysis of protein phosphorylation is more and more getting into the focus of proteomic research. Thousands of phosphopeptides can nowadays be identified using state-of-the-art tandem mass spectrometers in conjunction with sequence database searching, but localizing the phosphate group to a particular amino acid in the peptide sequence is often still difficult. Using 180 individually synthesized phosphopeptides with precisely known phosphorylation sites (p-sites), we have assessed the merits of the Mascot Delta Score (MD score) for the assignment of phosphorylation sites from tandem mass spectra (MS/MS) generated on four different matrix-assisted laser desorption ionization (MALDI) mass spectrometers including tandem time-of-flight (TOF/TOF), quadrupole time-of-flight, and ion trap mass analyzers. The results show that phosphorylation site identification is generally possible with false localization rates of about 10%. However, a comparison to previous work also revealed that phosphorylation site determination by MALDI MS/MS is less accurate than by ESI-MS/MS particularly if several and/or adjacent possible phosphorylation acceptor sites exist in a peptide sequence. We are making the tandem MS spectra and phosphopeptide collection available to the community so that scientists may adapt the MD scores reported here to their analytical environment and so that informatics developers may integrate the MD score into proteomic data analysis pipelines.
Assuntos
Fosfopeptídeos/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Fosfopeptídeos/síntese química , Fosforilação , Software , Espectrometria de Massas em TandemRESUMO
The beneficial effect of high mass accuracy in mass spectrometry is especially pronounced when using less specific enzymes as the number of theoretically possible peptides increases dramatically without any cleavage specificity defined. Together with a preceding chromatographic separation, high-resolution mass spectrometers such as the MALDI-LTQ-Orbitrap are therefore well suited for the analysis of protein digests with less specific enzymes. A combination with fast, automated, and informative MALDI-TOF/TOF analysis has already been shown to yield increased total peptide and protein identifications. Here, a simple method for nLC separation and subsequent alternating spotting on two targets for both a MALDI-LTQ-Orbitrap and a MALDI-TOF/TOF instrument is introduced. This allows for simultaneous measurements on both instruments and subsequent combination of both data sets by an in-house written software tool. The performance of this procedure was evaluated using a mixture of four standard proteins digested with elastase. Three replicate runs were examined concerning repeatability and the total information received from both instruments. A cytosolic extract of C. glutamicum was used to demonstrate the applicability to more complex samples. Database search results showed that an additional 32.3% of identified peptides were found using combined data sets in comparison to MALDI-TOF/TOF data sets.
Assuntos
Fragmentos de Peptídeos/química , Peptídeo Hidrolases/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Espectrometria de Massas em Tandem/métodos , Proteínas de Bactérias/química , Proteínas de Bactérias/metabolismo , Calibragem , Corynebacterium glutamicum/metabolismo , Padrões de Referência , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/normas , Espectrometria de Massas em Tandem/instrumentação , Espectrometria de Massas em Tandem/normasRESUMO
A simple, sensitive and fast method for the determination of melamine and its derivatives in milk powder using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was developed. Neither time-consuming sample preparation, nor special target plates, or other extra equipment are necessary. The common matrix sinapinic acid (SA) was used with a dried-droplet preparation. Detection limits (signal-to-noise (S/N) ratio = 3) for standard solutions of melamine, ammeline and cyanuric acid were 10, 25 and 10 µg/L, respectively. The limit of quantification (LOQ) for melamine was 25 µg/L and excellent linearity (R(2): 0.9990) was maintained over the range of 10-2000 µg/L. Ammeline and cyanuric acid were analyzed with an LOQ of 50 µg/L and also excellent linearity (R(2): 0.9997 and R(2): 0.9998). Good accuracy and precision were obtained for all concentrations within the range of the standard curve. The developed method was successfully used for the determination of melamine, ammeline and cyanuric acid in milk powder samples with a simple sample preparation. The LOQ of melamine was 0.5 µg/g. Ammeline and cyanuric acid were detectable at 0.5 and 5 µg/g. This method showed excellent accuracy, precision and linearity and significantly reduces the needed analysis time, as only approximately 10 s/sample measuring time is required. To the authors' knowledge, this is the first published method to quantify melamine and derivatives by MALDI-TOF-MS.