Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Neuroradiol ; 46(4): 248-255, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30179688

RESUMO

PURPOSE: To evaluate forensic identification of individuals through visual comparison of sphenoid sinus anatomical configuration using ante- and post-mortem CT-scans. METHOD AND MATERIALS: Ante- and post-mortem head CT-scan of 33 individuals were retrospectively collected. Ten head CT-scans were randomly selected from various neurological contexts and added to the ante-mortem group. Ten other head CT-scans were randomly selected from our post-mortem PACS and added to the post-mortem group. These CT-scans were assigned into 2 groups for analysis: an ante-mortem group (33 + 10) and a post-mortem group (33 + 10). For ethics and to avoid identification bias, CT-scans were anonymized - not showing any head structure but only sphenoid sinuses. An anatomical based classification system using the sphenoid sinuses anatomical variations was created according to anatomical and surgical literature. This classification was used by readers to identify in two different steps a maximum of matched and then unmatched scans. RESULTS: The first reader had a sensitivity of 100% [CI: 89.4%-100%] and a specificity of 100% [CI: 99.8%-100%]. Sensitivity and specificity were respectively 93.9% [CI: 79.8%-99.3%] and 99.9% [CI: 99.6%-100%] for the second reader. Positive and negative predictive values were respectively 100% [CI: 89.4%-100%] and 100% [CI: 99.8%-100%] for the first reader. Positive and negative values were respectively 96.9% [CI: 83.8%-99.9%] and 99.9% [CI: 99.7%-100%] for the second reader. Inter-reader variability was estimated by Cohen's kappa and an excellent agreement was found. CONCLUSION: We reported an excellent validity and reliability of subjective visual comparison of ante- and post-mortem CT-data using an anatomical based classification of the sphenoid sinus.


Assuntos
Medicina Legal/métodos , Seio Esfenoidal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Autopsia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
2.
J Neuroradiol ; 43(6): 404-414, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27083691

RESUMO

INTRODUCTION: Body identification is the cornerstone of forensic investigation. It can be performed using radiographic techniques, if antemortem images are available. This study was designed to assess the value of visual comparison of the computed tomography (CT) anatomical aspects of the sphenoid sinuses, in forensic individual identification, especially if antemortem dental records, fingerprints or DNA samples are not available. MATERIAL AND METHODS: This retrospective work took place in a French university hospital. The supervisor of this study randomly selected from the picture archiving and communication system (PACS), 58 patients who underwent one (16 patients) or two (42 patients) head CT in various neurological contexts. To avoid bias, those studies were prepared (anonymized, and all the head structures but the sphenoid sinuses were excluded), and used to constitute two working lists of 50 (42+8) CT studies of the sphenoid sinuses. An anatomical classification system of the sphenoid sinuses anatomical variations was created based on the anatomical and surgical literature. In these two working lists, three blinded readers had to identify, using the anatomical system and subjective visual comparison, 42 pairs of matched studies, and 16 unmatched studies. Readers were blinded from the exact numbers of matching studies. RESULTS: Each reader correctly identified the 42 pairs of CT with a concordance of 100% [97.5% confidence interval: 91-100%], and the 16 unmatched CT with a concordance of 100% [97.5% confidence interval: 79-100%]. Overall accuracy was 100%. CONCLUSION: Our study shows that establishing the anatomical concordance of the sphenoid sinuses by visual comparison could be used in personal identification. This easy method, based on a frequently and increasingly prescribed exam, still needs to be assessed on a postmortem cohort.


Assuntos
Identificação Biométrica/métodos , Medicina Legal/métodos , Seio Esfenoidal/anatomia & histologia , Seio Esfenoidal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
3.
Mil Med ; 181(7): 710-3, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27391626

RESUMO

OBJECTIVES: There are significant numbers of military and law enforcement bullets containing ferromagnetic materials. This study aimed to assess the magnetic field interactions for a representative sample of military and law enforcement ballistic objects at 1.5 and 3 tesla (T) to create a magnetic resonance imaging (MRI) compatibility database. METHODS: Twenty-nine different bullets underwent MRI evaluation. The deflection angle method and a qualitative torque scale were used. The samples were representative of those commonly used in the North Atlantic Treaty Organization (NATO) military forces (e.g., 5.56 mm NATO), law enforcement agencies (e.g., 9 mm Parabellum), and encountered in war injuries and crime-related trauma (e.g., 7.62 mm Kalashnikov). RESULTS: At all static magnetic field strengths, all non-nickel- and nonsteel-containing bullets exhibited no movement (deflection angle = 0°; torque = 0), whereas eight bullets containing steel core, steel jacket, or nickel jacket exhibited substantial magnetic field interactions over and above what might be regarded as safe in vivo (deflection angle = 90°; torque = 4+). CONCLUSION: Military and law enforcement non-nickel- or nonsteel-containing bullets appear to be safe for patients in MRI system at 1.5 and 3 T. On the other hand, nickel- and steel-containing bullets exhibit movements that are considered potentially unsafe for patients in an MRI environment.


Assuntos
Campos Magnéticos/efeitos adversos , Imageamento por Ressonância Magnética/efeitos adversos , Militares/estatística & dados numéricos , Polícia/estatística & dados numéricos , Cobre/efeitos adversos , Cobre/análise , Humanos , Chumbo/efeitos adversos , Chumbo/análise , Ciência dos Materiais/métodos , Níquel/efeitos adversos , Níquel/análise , Aço/efeitos adversos , Aço/análise , Zinco/efeitos adversos , Zinco/análise
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa