Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38587017

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , América Latina , Resultado do Tratamento , Catéteres , Ásia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
2.
J Cardiovasc Electrophysiol ; 34(4): 942-946, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36738141

RESUMO

INTRODUCTION: Radiofrequency ablation (RFA) slow pathway modification for catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT) is traditionally performed using a 4-mm nonirrigated (NI) RF ablation catheter. Slow pathway modification using irrigated, contact-force sensing (ICFS) RFA catheters has been described in case reports, but the outcomes have not been systematically evaluated. METHODS: Acute procedural outcomes of 200 consecutive patients undergoing slow pathway modification for AVNRT were analyzed. A 3.5-mm ICFS RFA catheter (ThermoCool SmartTouch STSF, Biosense Webster, Inc.) was utilized in 134 patients, and a 4-mm NI RFA catheter (EZ Steer, Biosense Webster, Inc.) was utilized in 66 patients. Electroanatomic maps were retrospectively analyzed in a blinded fashion to determine the proximity of ablation lesions to the His region. RESULTS: The baseline characteristics of patients in both groups were similar. Total RF time was significantly lower in the ICFS group compared to the NI group (5.53 ± 4.6 vs. 6.24 ± 4.9 min, p = 0.03). Median procedure time was similar in both groups (ICFS, 108.0 (87.5-131.5) min vs. NI, 100.0 (85.0-125.0) min; p = 0.2). Ablation was required in closer proximity to the His region in the NI group compared to the ICFS group (14.4 ± 5.9 vs. 16.7 ± 6.4 mm, respectively, p = 0.01). AVNRT was rendered noninducible in all patients, and there was no arrhythmia recurrence during follow-up in both groups. Catheter ablation was complicated by AV block in one patient in the NI group. CONCLUSION: Slow pathway modification for catheter ablation of AVNRT using an ICFS RFA catheter is feasible, safe, and may facilitate shorter duration ablation while avoiding ablation in close proximity to the His region.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Taquicardia por Reentrada no Nó Atrioventricular , Humanos , Estudos Retrospectivos , Catéteres
3.
J Cardiovasc Electrophysiol ; 34(4): 800-807, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36738147

RESUMO

INTRODUCTION: Radiofrequency ablation technology for treating atrial fibrillation (AF) has evolved rapidly over the past decade. We investigated the impact of technological and procedural advances on procedure times and ablation outcomes at a major academic medical center over a 10-year period. METHODS: Clinical data was collected from patients who presented to NYU Langone Health between 2011 and 2021 for a first-time AF ablation. Time to redo AF ablation or direct current cardioversion (DCCV) for recurrent AF during a 3-year follow-up period was determined and correlated with ablation technology and practices, antiarrhythmic medications, and patient comorbid conditions. RESULTS: From 2011 to 2021, the cardiac electrophysiology lab adopted irrigated-contact force ablation catheters, high-power short duration ablation lesions, steady-pacing, jet ventilation, and eliminated stepwise linear ablation for AF ablation. During this time the number of first time AF ablations increased from 403 to 1074, the percentage of patients requiring repeat AF-related intervention within 3-years of the index procedure dropped from 22% to 14%, mean procedure time decreased from 271 ± 65 to 135 ± 36 min, and mean annual major adverse event rate remained constant at 1.1 ± 0.5%. Patient comorbid conditions increased during this time period and antiarrhythmic use was unchanged. CONCLUSION: Rates of redo-AF ablation or DCCV following an initial AF ablation at a single center decreased 36% over a 10-year period. Procedural and technological changes likely contributed to this improvement, despite increased AF related comorbidities.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Antiarrítmicos/uso terapêutico , Fatores de Tempo , Ablação por Cateter/métodos
4.
J Cardiovasc Electrophysiol ; 31(6): 1462-1469, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32356380

RESUMO

INTRODUCTION: Implantable cardioverter defibrillators (ICDs) are proven to prevent sudden death in patients at elevated risk for sustained ventricular tachycardia or fibrillation. Complications related to ICD failure can stem from lead dysfunction, manufacturing defects, patient characteristics, or implantation technique. We conducted a review of all ICD leads implanted at our center from 2011 to 2017 to determine risk factors for premature lead failure. METHODS: We conducted a retrospective review of patients of all ICD leads implanted from December 2011 to June 2017 at our institution. A total of 660 patients (Biotronik Linox S/SD, n = 281; Sprint Quatro, n = 207; Durata, n = 121; Endotak, n = 51) underwent ICD implantations. Patient and lead characteristics, procedural outcomes and complications were recorded. Lead failure was defined per Heart Rhythm Society lead-management consensus as a lack of procedural or clinical success, thus requiring an extraction of the lead. Patient and lead outcomes were recorded and variables associated with lead failure were assessed by the Kaplan-Meier method. RESULTS: Overall failure rate was similar for all leads: Linox S/SD-0.29%/year; Sprint Quattro-0.21%/year, Durata-0.39%/year and Endotak Reliance-0.0% (P = .769). No difference was found in overall survival when comparing all ICD manufacturers during the study period. Subgroup analysis revealed the risk of premature lead failure was particularly pronounced in multi-lead ICD systems implanted via cephalic access (P < .001). The estimated failure rate of Linox leads implanted via cephalic access in multi-lead systems was 19%/year. The estimated failure rate of non-Linox leads implanted via cephalic access in multi-lead systems was 11%/year. Neither age, nor gender were risk factors for lead failure in the Linox, or non-Linox cohorts. CONCLUSION: All analyzed ICD leads were found to have a similar overall risk of premature failure. ICD lead implantation via cephalic access in multilead ICD systems may be a previously unidentified risk factor for premature ICD lead failure, although these findings require further validation.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Falha de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Cardioversão Elétrica/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 31(6): 1379-1384, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32243641

RESUMO

INTRODUCTION: Acute hemopericardium during cardiac electrophysiology (EP) procedures may result in significant blood loss and is the most common cause of procedure-related death. Matched allogeneic blood is often not immediately available. The feasibility and safety of direct autotransfusion in cardiac electrophysiology patients requiring emergency pericardiocentesis is unknown. METHODS: We retrospectively analyzed records of patients undergoing EP procedures at a single, tertiary care medical center who had procedure-related acute hemopericardium requiring emergency pericardiocentesis during a 3-year period. Procedure details, transfusion volumes, and clinical outcomes of patients who received direct autotransfusion of aspirated pericardial blood via a femoral venous sheath were compared to those of patients who did not receive direct autotransfusion. RESULTS: During the study period, 10 patients received direct autotransfusion (group 1) and outcomes were compared with those of 14 control patients who did not receive direct autotransfusion (group 2). The volume of aspirated pericardial blood was similar in groups 1 and 2 (1.6 ± 0.7 L vs 1.3 ± 1.0 L, respectively; P = .52). Amongst patients with aspirated volumes <1 L, group 1 patients (n = 4) were less likely than group 2 patients (n = 8) to require allotransfusion (0% vs 75%, P = .02). Amongst patients with aspirated volume ≥1 L, group 1 patients (n = 6) required fewer units of red cell allotransfusion than group 2 patients (n = 6) (1.5 ± 0.8 units vs 4.3 ± 2.0 units, P = .01). No procedural complications related to direct autotransfusion occurred. CONCLUSIONS: Direct autotransfusion following emergency pericardiocentesis during electrophysiology procedures requiring systemic anticoagulation is feasible and safe. The utilization of direct autotransfusion may eliminate or reduce the need for allotransfusion.


Assuntos
Transfusão de Sangue Autóloga , Tamponamento Cardíaco/terapia , Ablação por Cateter/efeitos adversos , Derrame Pericárdico/terapia , Pericardiocentese , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/uso terapêutico , Transfusão de Sangue Autóloga/efeitos adversos , Tamponamento Cardíaco/diagnóstico por imagem , Tamponamento Cardíaco/etiologia , Emergências , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Derrame Pericárdico/diagnóstico por imagem , Derrame Pericárdico/etiologia , Pericardiocentese/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 31(12): 3117-3123, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33022816

RESUMO

OBJECTIVE: To compare multiple-procedure catheter ablation outcomes of a stepwise approach versus left atrial posterior wall isolation (LA PWI) in patients undergoing nonparoxysmal atrial fibrillation (NPAF) ablation. BACKGROUND: Unfavorable outcomes for stepwise ablation of NPAF in large clinical trials may be attributable to proarrhythmic effects of incomplete ablation lines. It is unknown if a more extensive initial ablation strategy results in improved outcomes following multiple ablation procedures. METHODS: Two hundred twenty two consecutive patients with NPAF underwent first-time ablation using a contact-force sensing ablation catheter utilizing either a stepwise (Group 1, n = 111) or LA PWI (Group 2, n = 111) approach. The duration of follow-up was 36 months. The primary endpoint was freedom from atrial arrhythmia >30 s. Secondary endpoints were freedom from persistent arrhythmia, repeat ablation, and recurrent arrhythmia after repeat ablation. RESULTS: There was similar freedom from atrial arrhythmias after index ablation for both stepwise and LA PWI groups at 36 months (60% vs. 69%, p = .1). The stepwise group was more likely to present with persistent recurrent arrhythmia (29% vs. 14%, p = .005) and more likely to undergo second catheter ablation (32% vs. 12%, p < .001) compared to LA PWI patients. Recurrent arrhythmia after repeat ablation was more likely in the stepwise group compared to the LA PWI group (15% vs. 4%, p = .003). CONCLUSIONS: Compared to a stepwise approach, LA PWI for patients with NPAF resulted in a similar incidence of any atrial arrhythmia, lower incidence of persistent arrhythmia, and fewer repeat ablations. Results for repeat ablation were not improved with a more extensive initial approach.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 31(7): 1678-1686, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32314841

RESUMO

INTRODUCTION: Catheter stability during atrial fibrillation ablation is associated with higher ablation success rates. Rapid cardiac pacing and high-frequency jet ventilation (HFJV) independently improve catheter stability. Simultaneous modulation of cardiac and respiratory motion has not been previously studied. The objective of this study was to determine the effect of simultaneous heart rate and respiratory rate modulation on catheter stability. METHODS: Forty patients undergoing paroxysmal atrial fibrillation ablation received ablation lesions at 15 prespecified locations (12 left atria, 3 right atria). Patients were randomly assigned to undergo rapid atrial pacing for either the first or the second half of each lesion. Within each group, half of the patients received HFJV and the other half standard ventilation. Contact force and ablation data for all lesions were compared among the study groups. Standard deviation of contact force was the primary endpoint defined to examine contact force variability. RESULTS: Lesions with no pacing and standard ventilation had the greatest contact force standard deviation (5.86 ± 3.08 g), compared to lesions with pacing and standard ventilation (5.45 ± 3.28 g; P < .01) or to lesions with no pacing and HFJV (4.92 ± 3.00 g; P < .01). Lesions with both pacing and HFJV had the greatest reduction in contact force standard deviation (4.35 ± 2.81 g; P < .01), confirming an additive benefit of each maneuver. Pacing and HFJV together was also associated with a reduction in the proportion of lesions with excessive maximum contact force (P < .001). DISCUSSION: Rapid pacing and HFJV additively improve catheter stability. Simultaneous pacing with HFJV further improves catheter stability over pacing or HFJV alone to optimize ablation lesions.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Ventilação em Jatos de Alta Frequência , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Catéteres , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos
8.
Pacing Clin Electrophysiol ; 42(10): 1347-1354, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31429947

RESUMO

INTRODUCTION: A common complication of transcatheter aortic valve repair (TAVR) is development of conduction defects requiring pacemaker (PPM) implantation. These defects are not universally permanent. OBJECTIVE: To determine the incidence and predictors of persistent device dependency in patients with PPM implantation following TAVR with a self-expanding prosthesis. METHODS: Records of patients who underwent post-TAVR PPM implantation were reviewed. Patients with persistent complete AV block (AVBIII) one month post-TAVR were compared to those regaining conduction. RESULTS: Between September 2014 and March 2017, 485 patients underwent TAVR with a self-expanding prosthesis; 77 (15.9%) underwent PPM implantation for AVBIII. Device interrogation at one month was available for 61 patients (79%): 22 (36.1%) had resolution of AVBIII while 39 (63.9%) remained pacemaker-dependent. Pre-TAVR right bundle branch block was more frequent in device-dependent patients (19 of 38, 50% vs 4 of 22, 18%; RR 2.75; P = .01). Device-dependence was associated with AVBIII as the first postprocedural rhythm (37 of 39, 95% vs 12 of 22, 55%; RR 1.74; P < .0001), earlier implantation (median 1d, IQR: 0-1.5d vs 2d, IQR: 1.0-4.0d, P = .0004), and a shorter duration of hospitalization (median 3d, IQR: 2-3.5d vs 4d, IQR: 2-5.75d, P = .03). Pacemaker dependence was also associated with a higher prosthesis-to left ventricular outflow tract (LVOT) diameter (1.45 ± 0.11 vs 1.39 ± 0.07; P = .02) and the lack of prior aortic valvuloplasty (5 of 39, 13% vs 8 of 22, 36%; RR 0.35; P = .03). CONCLUSIONS: In patients receiving a PPM following self-expanding TAVR, a long-term pacing requirement can be predicted from the timing of AV block, existing conduction-system disease, larger prosthesis-to-LVOT diameter, and the lack of aortic valvuloplasty.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bloqueio Atrioventricular/etiologia , Prótese Vascular , Marca-Passo Artificial , Complicações Pós-Operatórias/etiologia , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Eletrocardiografia , Feminino , Humanos , Masculino , Desenho de Prótese , Fatores de Risco
11.
Europace ; 20(4): 596-603, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28339750

RESUMO

Aims: Atrial tachycardia (AT) related to atrial fibrillation (AF) ablation frequently poses a diagnostic challenge. Downstream overdrive pacing (DOP) can be used to rapidly detect reentry and assess proximity of a pacing site to an AT circuit or focus. We hypothesized that systematic DOP using multielectrode catheters would facilitate AT mapping. Methods and results: DOP identified constant fusion when the post-pacing interval (PPI)-tachycardia cycle length (TCL) <40 ms and stimulus to adjacent upstream atrial electrogram interval >75% of TCL. Mapping was performed as follows: (i) CS DOP, (ii) DOP at left atrial (LA) roof, (iii) DOP at selected LA sites based on prior DOP attempts, and (iv) mapping and ablation at regions of fractionated electrograms in region of AT. Activation mapping was performed at operator discretion. AT diagnosis was confirmed by successful ablation or additional mapping when ablation was unsuccessful. Fifty consecutive patients with sustained AT underwent mapping of 68 ATs, of whom 42 (62%) were macroreentrant, 19 were locally reentrant (28%), and 7 (10%) were focal. AT was correctly identified with a median of three DOP attempts. All macroreentrant ATs were identified with ≤6 DOP attempts. One AT (1.6%) was terminated by DOP, and three ATs (4.8%) required activation mapping. Intracardiac concealed fusion was seen in 26 ATs (38%), each of which was successfully ablated. Conclusion: Reentry could be demonstrated in a substantial majority of AF ablation-related AT. A stepwise diagnostic approach using DOP and recognition of intracardiac concealed fusion can be used to rapidly identify and ablate reentrant AT.


Assuntos
Fibrilação Atrial/cirurgia , Cateterismo Cardíaco , Estimulação Cardíaca Artificial , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Supraventricular/diagnóstico , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Valor Preditivo dos Testes , Fatores de Risco , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/fisiopatologia , Resultado do Tratamento
12.
Pacing Clin Electrophysiol ; 40(2): 183-190, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28054374

RESUMO

BACKGROUND: Patients on rivaroxaban have variable international normalized ratios (INRs) but it is uncertain if INR impacts procedural heparin requirement during left atrial ablation. We sought to examine the determinants of heparin dosing in this patient population. METHODS: We reviewed consecutive patients who received rivaroxaban within 24 hours of left atrial ablation and compared them to patients on uninterrupted warfarin. The determinants of heparin requirement were evaluated using regression analysis. We then tested a weight-based heparin dose prospectively in rivaroxaban patients. RESULTS: There were 258 patients on rivaroxaban and 213 on warfarin. The mean INR was 1.4 in the rivaroxaban group and 2.3 in the warfarin group (P < 0.01). To achieve an activated clotting time (ACT) >350 seconds, rivaroxaban patients required significantly more heparin (166.9 vs. 78.3 units/kg, P < 0.001). In the rivaroxaban group, body weight was the strongest predictor of heparin dose (r = 0.52), while INR was weakly correlated (r = -0.21). In the prospective group, 25 patients were given an initial heparin dose of 120 units/kg with 22/25 (88%) achieving an ACT > 300 seconds. There were seven and three cases of pericardial effusion in rivaroxaban and warfarin patients, respectively (P = 0.41). The average volume drained in the rivaroxaban group was elevated (988.6 vs. 275.0 mL, P = 0.21). CONCLUSIONS: Body weight is the strongest predictor of procedural heparin requirement during left atrial ablation in patients on uninterrupted rivaroxaban, even in those with an elevated INR. A heparin dose of 120 units/kg achieves an ACT > 300 seconds in the majority of patients. In cases of pericardial effusion, bleeding may be prolonged.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Heparina/administração & dosagem , Rivaroxabana/administração & dosagem , Tromboembolia/epidemiologia , Tromboembolia/prevenção & controle , Administração Oral , Anticoagulantes/administração & dosagem , Peso Corporal , Relação Dose-Resposta a Droga , Quimioterapia Combinada/estatística & dados numéricos , Feminino , Fibrinolíticos/administração & dosagem , Fibrinolíticos/efeitos adversos , Átrios do Coração/efeitos dos fármacos , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Pré-Medicação/estatística & dados numéricos , Prevalência , Fatores de Risco , Rivaroxabana/efeitos adversos , Resultado do Tratamento , Estados Unidos/epidemiologia
13.
Circulation ; 129(24): 2503-10, 2014 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-24812357

RESUMO

BACKGROUND: Entrainment criteria for macroreentrant arrhythmias are based on detecting fusion between tachycardia and paced wavefronts, but this is often difficult for atrial tachycardias (AT) after ablation of atrial fibrillation. METHODS AND RESULTS: With the use of a multipolar catheter, pacing was performed from electrodes within the coronary sinus showing activation later than adjacent electrodes (downstream overdrive pacing) during 66 ATs in 62 patients: 20 cavotricuspid isthmus-dependent ATs, 20 perimitral ATs, 13 focal ATs with sequential coronary sinus activation, and 13 other macroreentrant left atrial ATs. The paced cycle length was 10 to 30 milliseconds below the tachycardia cycle length (TCL), and activation at the neighboring upstream electrodes was assessed. Downstream overdrive pacing at 48 sites close to a macroreentrant circuit (PPI-TCL <40 milliseconds, where PPI is postpacing interval) produced constant fusion demonstrated by a long stimulus to upstream atrial electrogram interval (S-Au) >75% TCL and was consistent with orthodromic activation of the upstream site despite its close proximity to the pacing site. In contrast, downstream overdrive pacing at 18 sites during focal AT or remote from the macroreentrant AT circuit (PPI-TCL >40 milliseconds) always demonstrated a comparatively short S-Au <25% of TCL (12±4% versus 89±4% of TCL; P<0.001), consistent with direct activation. CONCLUSIONS: Selection of a downstream activation site for overdrive pacing can facilitate rapid recognition of macroreentry and proximity to the reentry circuit using a single multielectrode catheter by recognizing a PPI-TCL <40 milliseconds and S-Au >75% of TCL. Recognition of intracardiac constant fusion with this method is a novel criterion for transient entrainment.


Assuntos
Estimulação Cardíaca Artificial/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/terapia , Taquicardia Atrial Ectópica/diagnóstico , Taquicardia Atrial Ectópica/terapia , Idoso , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Flutter Atrial/terapia , Ablação por Cateter , Eletrodos Implantados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Atrial Ectópica/cirurgia
15.
Europace ; 17(10): 1571-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25840288

RESUMO

AIMS: In patients presenting with spontaneous sustained ventricular tachycardia (VT) from the outflow-tract region without overt structural heart disease ablation may target premature ventricular contractions (PVCs) when VT is not inducible. We aimed to determine whether inducibility of VT affects ablation outcome. METHODS AND RESULTS: Data from 54 patients (31 men; age, 52 ± 13 years) without overt structural heart disease who underwent catheter ablation for symptomatic sustained VT originating from the right- or left-ventricular outflow region, including the great vessels. A single morphology of sustained VT was inducible in 18 (33%, SM group) patients, and 11 (20%) had multiple VT morphologies (MM group). VT was not inducible in 25 (46%) patients (VTni group). After ablation, VT was inducible in none of the SM group and in two (17%) patients in the MM group. In the VTni group, ablation targeted PVCs and 12 (48%) patients had some remaining PVCs after ablation. During follow-up (21 ± 19 months), VT recurred in 46% of VTni group, 40% of MM inducible group, and 6% of the SM inducible group (P = 0.004). Analysis of PVC morphology in the VTi group further supported the limitations of targeting PVCs in this population. CONCLUSION: Absence of inducible VT and multiple VT morphologies are not uncommon in patients with documented sustained outflow-tract VT without overt structural heart disease. Inducible VT is associated with better outcomes, suggesting that attempts to induce VT to guide ablation are important in this population.


Assuntos
Ablação por Cateter/normas , Eletrocardiografia/classificação , Ventrículos do Coração/fisiopatologia , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/cirurgia , Adulto , Idoso , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Recidiva , Resultado do Tratamento
16.
Am Heart J Plus ; 44: 100421, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39070127

RESUMO

Background: Catheter ablation (CA) for ventricular tachycardia (VT) can be a useful treatment strategy, however, few studies have compared CA to medical therapy (MT) in the sarcoidosis population. Objective: To assess in-hospital outcomes and unplanned readmissions following CA for VT compared to MT in patients with sarcoidosis. Methods: Data was obtained from the Nationwide Readmissions Database between 2010 and 2019 to identify patients with sarcoidosis admitted for VT either undergoing CA or MT during elective and non-elective admission. Primary endpoints were a composite endpoint of inpatient mortality, cardiogenic shock, cardiac arrest and 30-day hospital readmissions. Procedural complications at index admission and causes of readmission were also identified. Results: Among 1581 patients, 1217 with sarcoidosis and VT underwent MT compared to 168 with CA during non-elective admission. 63 patients admitted electively underwent CA compared with 129 managed medically. There was no difference in the composite outcome for patients undergoing catheter ablation or medical therapy during both non-elective (9.0 % vs 12.0 %, p = 0.312) and elective admission (3.2 % vs. 7.8 %, p = 0.343). The most common cause of readmission were ventricular arrhythmias (VA) in both groups, however, those undergoing elective CA were less likely to be readmitted for VA compared to non-elective CA. The most common complication in the CA group was cardiac tamponade (4.8 %). Conclusion: VT ablation is associated with similar rates of 30-day readmission compared to MT and does not confer increased risk of harm with respect to inpatient mortality, cardiogenic shock or cardiac arrest. Further research is warranted to determine if a subgroup of sarcoidosis patients admitted with VT are better served with an initial conservative management strategy followed by VT ablation.

17.
Artigo em Inglês | MEDLINE | ID: mdl-39230634

RESUMO

BACKGROUND: Combined catheter ablation (CA) with percutaneous left atrial appendage closure (LAAC) may produce comprehensive treatment for atrial fibrillation (AF) whereby rhythm control is achieved and stroke risk is reduced without the need for chronic oral anticoagulation. However, the efficacy and safety of this strategy is still controversial. METHODS: This meta-analysis was reported according to the Preferred Reporting Items for Systematic Review and Meta-Analyses guidelines. Medline, Scopus, and Cochrane Central Register of Controlled Trials were systematically searched to identify relevant studies. The risk of bias was assessed using the Modified Newcastle-Ottawa scale and Cochrane risk of bias tool. Eligible studies reported outcomes in patients with AF who underwent combined CA and LAAC vs CA alone. Studies performing CA without pulmonary vein isolation were excluded. RESULTS: Eight studies comprising 1878 patients were included (2 RCT, 6 observational). When comparing combined CA and LAAC vs CA alone, pooled results showed no difference in arrhythmia recurrence (risk ratio (RR) 1.04; 95% confidence interval (CI) 0.82-1.33), stroke or systemic embolism (RR 0.78; 95% CI 0.27-2.22), or major periprocedural complications (RR 1.28; 95% CI 0.28-5.89). Total procedure time was shorter with CA alone (mean difference 48.45 min; 95% CI 23.06-74.62). CONCLUSION: Combined CA with LAAC for AF is associated with similar rates of arrhythmia-free survival, stroke, and major periprocedural complications when compared to CA alone. A combined strategy may be as safe and efficacious for patients at moderate to high risk for bleeding events to negate the need for chronic oral anticoagulation.

18.
Heart Rhythm ; 21(9): e31-e149, 2024 09.
Artigo em Inglês | MEDLINE | ID: mdl-38597857

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Consenso , Sociedades Médicas , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Humanos , Ablação por Cateter/métodos , Europa (Continente) , América Latina , Ásia
19.
J Interv Card Electrophysiol ; 67(5): 921-1072, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38609733

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Consenso , Sociedades Médicas , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Humanos , Europa (Continente) , América Latina , Ásia
20.
Adv Radiat Oncol ; 8(6): 101272, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37415904

RESUMO

Purpose: Cardiac radioablation is an emerging therapy for recurrent ventricular tachycardia. Electrophysiology (EP) data, including electroanatomic maps (EAM) and electrocardiographic imaging (ECGI), provide crucial information for defining the arrhythmogenic target volume. The absence of standardized workflows and software tools to integrate the EP maps into a radiation planning system limits their use. This study developed a comprehensive software tool to enable efficient utilization of the mapping for cardiac radioablation treatment planning. Methods and Materials: The tool, HeaRTmap, is a Python-scripted plug-in module on the open-source 3D Slicer software platform. HeaRTmap is able to import EAM and ECGI data and visualize the maps in 3D Slicer. The EAM is translated into a 3D space by registration with cardiac magnetic resonance images (MRI) or computed tomography (CT). After the scar area is outlined on the mapping surface, the tool extracts and extends the annotated patch into a closed surface and converts it into a structure set associated with the anatomic images. The tool then exports the structure set and the images as The Digital Imaging and Communications in Medicine Standard in Radiotherapy for a radiation treatment planning system to import. Overlapping the scar structure on simulation CT, a transmural target volume is delineated for treatment planning. Results: The tool has been used to transfer Ensite NavX EAM data into the Varian Eclipse treatment planning system in radioablation on 2 patients with ventricular tachycardia. The ECGI data from CardioInsight was retrospectively evaluated using the tool to derive the target volume for a patient with left ventricular assist device, showing volumetric matching with the clinically used target with a Dice coefficient of 0.71. Conclusions: HeaRTmap smoothly fuses EP information from different mapping systems with simulation CT for accurate definition of radiation target volume. The efficient integration of EP data into treatment planning potentially facilitates the study and adoption of the technique.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa