1.
J Med Internet Res ; 25: e43658, 2023 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-37999957

RESUMO

There are over 8 million central venous access devices inserted each year, many in patients with chronic conditions who rely on central access for life-preserving therapies. Central venous access device-related complications can be life-threatening and add tens of billions of dollars to health care costs, while their incidence is most likely grossly mis- or underreported by medical institutions. In this communication, we review the challenges that impair retention, exchange, and analysis of data necessary for a meaningful understanding of critical events and outcomes in this clinical domain. The difficulty is not only with data extraction and harmonization from electronic health records, national surveillance systems, or other health information repositories where data might be stored. The problem is that reliable and appropriate data are not recorded, or falsely recorded, at least in part because policy, payment, penalties, proprietary concerns, and workflow burdens discourage completeness and accuracy. We provide a roadmap for the development of health care information systems and infrastructure that address these challenges, framed within the context of research studies that build a framework of standardized terminology, decision support, data capture, and information exchange necessary for the task. This roadmap is embedded in a broader Coordinated Registry Network Learning Community, and facilitated by the Medical Device Epidemiology Network, a Public-Private Partnership sponsored by the US Food and Drug Administration, with the scope of advancing methods, national and international infrastructure, and partnerships needed for the evaluation of medical devices throughout their total life cycle.


Assuntos
Custos de Cuidados de Saúde , Assistência Centrada no Paciente , Humanos , Comunicação , Sistema de Registros
2.
J Vasc Interv Radiol ; 32(8): 1240.e1-1240.e8, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34332723

RESUMO

Recently developed endovascular techniques to create percutaneous arteriovenous fistulas are an alternative to surgical arteriovenous fistula creation, although there is currently a lack of high-level evidence regarding their creation, maturation, utilization, and long-term function. Recognizing this, the Society of Interventional Radiology Foundation sponsored a Research Consensus Panel and Summit for the prioritization of a research agenda to identify and address the gaps in current knowledge.


Assuntos
Fístula Arteriovenosa , Derivação Arteriovenosa Cirúrgica , Falência Renal Crônica , Fístula Arteriovenosa/diagnóstico por imagem , Fístula Arteriovenosa/terapia , Consenso , Humanos , Pesquisa Interdisciplinar , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/terapia , Diálise Renal , Resultado do Tratamento , Grau de Desobstrução Vascular
4.
J Hepatol ; 66(5): 987-1000, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28027971

RESUMO

BACKGROUND & AIMS: Hepatocyte transplantation partially corrects genetic disorders and has been associated anecdotally with reversal of acute liver failure. Monitoring for graft function and rejection has been difficult, and has contributed to limited graft survival. Here we aimed to use preparative liver-directed radiation therapy, and continuous monitoring for possible rejection in an attempt to overcome these limitations. METHODS: Preparative hepatic irradiation was examined in non-human primates as a strategy to improve engraftment of donor hepatocytes, and was then applied in human subjects. T cell immune monitoring was also examined in human subjects to assess adequacy of immunosuppression. RESULTS: Porcine hepatocyte transplants engrafted and expanded to comprise up to 15% of irradiated segments in immunosuppressed monkeys preconditioned with 10Gy liver-directed irradiation. Two patients with urea cycle deficiencies had early graft loss following hepatocyte transplantation; retrospective immune monitoring suggested the need for additional immunosuppression. Preparative radiation, anti-lymphocyte induction, and frequent immune monitoring were instituted for hepatocyte transplantation in a 27year old female with classical phenylketonuria. Post-transplant liver biopsies demonstrated multiple small clusters of transplanted cells, multiple mitoses, and Ki67+ hepatocytes. Mean peripheral blood phenylalanine (PHE) level fell from pre-transplant levels of 1343±48µM (normal 30-119µM) to 854±25µM (treatment goal ≤360µM) after transplant (36% decrease; p<0.0001), despite transplantation of only half the target number of donor hepatocytes. PHE levels remained below 900µM during supervised follow-up, but graft loss occurred after follow-up became inconsistent. CONCLUSIONS: Radiation preconditioning and serial rejection risk assessment may produce better engraftment and long-term survival of transplanted hepatocytes. Hepatocyte xenografts engraft for a period of months in non-human primates and may provide effective therapy for patients with acute liver failure. LAY SUMMARY: Hepatocyte transplantation can potentially be used to treat genetic liver disorders but its application in clinical practice has been impeded by inefficient hepatocyte engraftment and the inability to monitor rejection of transplanted liver cells. In this study, we first show in non-human primates that pretreatment of the host liver with radiation improves the engraftment of transplanted liver cells. We then used this knowledge in a series of clinical hepatocyte transplants in patients with genetic liver disorders to show that radiation pretreatment and rejection risk monitoring are safe and, if optimized, could improve engraftment and long-term survival of transplanted hepatocytes in patients.


Assuntos
Rejeição de Enxerto , Hepatócitos/transplante , Fígado/efeitos da radiação , Condicionamento Pré-Transplante , Adulto , Animais , Feminino , Humanos , Hepatopatias/terapia , Macaca fascicularis , Masculino , Suínos , Transplante Heterólogo
5.
J Vasc Interv Radiol ; 28(8): 1189-1193, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28735936

RESUMO

Four children (3 boys and 1 girl, age 1.4-9.4 y) presented 2-70 months after liver transplantation (mean 26 months) with high-grade narrowing at the surgical anastomosis that could not be crossed at percutaneous transhepatic cholangiography. Each patient was treated with a combined surgical and interventional radiology "rendezvous" procedure. Biliary drainage catheters were left in place for an average of 6 months after the procedure. At a mean 7.5 months after biliary drainage catheter removal, all children were catheter-free without clinical or biochemical evidence of biliary stricture recurrence.


Assuntos
Procedimentos Cirúrgicos do Sistema Biliar/métodos , Cateterismo/métodos , Colestase/terapia , Drenagem/métodos , Transplante de Fígado , Complicações Pós-Operatórias/terapia , Anastomose Cirúrgica , Criança , Pré-Escolar , Terapia Combinada , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos
7.
J Vasc Interv Radiol ; 25(3): 411-8, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24581464

RESUMO

PURPOSE: To study selective use of antibiotic-impregnated catheters in children at increased risk of venous catheter-related infections (CRIs). MATERIALS AND METHODS: From December 2008 to June 2009, 428 peripherally inserted central catheters (PICCs) were placed by the interventional radiology service of a large metropolitan children's hospital. This retrospective study analyzed demographic and outcome data for the 125 patients in this group at high risk for venous CRI. Patients at high risk were those with active systemic infection, previous complicated central venous access, intensive care unit (ICU) admission, intestinal failure, transplantation, complex congenital heart disease, or renal failure. Patients (age, 7.6 y ± 7.0; 73 male and 52 female) received a conventional or antibiotic-impregnated PICC, with 17 receiving more than one catheter. RESULTS: Of the 146 of 428 qualifying patient encounters (34%), 53 patients received an antibiotic-impregnated PICC and 93 received a conventional PICC, representing 5,080 total catheter-days (CDs). The rates of CRIs per 1,000 CDs, including catheter exit site infections and catheter-related bloodstream infections, were 0.86 for antibiotic-impregnated PICCs and 5.5 for conventional PICCs (P = .036). A propensity-based model predicts 15-fold greater infection-free survival over the lifetime of the catheter in patients who receive an antibiotic-impregnated PICC (P < .001). Antibiotic-impregnated PICC recipients with active infection or ICU admission at the time of insertion had no catheter-associated infections, compared with 3.42 and 9.46 infections per 1,000 CDs, respectively, for patients who received conventional PICCs. Patients with intestinal failure had 1.49 and 10 infections per 1,000 CDs with antibiotic-impregnated versus conventional PICCs, respectively. CONCLUSIONS: Antibiotic-impregnated long-term PICCs significantly improve infection-free catheter survival in pediatric patients at high risk.


Assuntos
Antibacterianos/administração & dosagem , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/prevenção & controle , Cateteres Venosos Centrais/estatística & dados numéricos , Implantes de Medicamento/uso terapêutico , Stents Farmacológicos/estatística & dados numéricos , Infecções Relacionadas a Cateter/diagnóstico por imagem , Criança , Intervalo Livre de Doença , Feminino , Humanos , Estudos Longitudinais , Masculino , Pennsylvania/epidemiologia , Prevalência , Radiografia Intervencionista/estatística & dados numéricos , Fatores de Risco , Resultado do Tratamento
11.
J Vasc Interv Radiol ; 23(5): 604-12, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22459877

RESUMO

PURPOSE: To report the outcome of tunneled dialysis catheter insertion in 120 patients. MATERIALS AND METHODS: A retrospective review of the interventional radiology database and electronic medical records of 120 patients who had tunneled dialysis catheters inserted from April 1997 to July 2010 was performed with institutional review board approval. There were 61 female patients and 59 male patients, with a mean age of 13.3 years (range, 0.2-28.5 y). A total of 193 primary insertions and 330 salvage procedures were performed. RESULTS: The technical success rate for primary catheter insertions was 100%. Immediate complications included self-limiting tract bleeding and air embolism in two of 193 insertions each (1.03%). Mean indwell duration for primary insertions was 66 catheter-days (range, 1-765 d), compared with a total mean of 159.4 catheter-days (range, 1-1,034 d). Rates of infection and mechanical complications were 0.21 and 0.9 per 100 total catheter-days, respectively. Mechanical and infections complications were increased in children younger than 9 years of age and weighing less than 20 kg. The catheter removal rates for infection and mechanical complications were 0.084 and 0.081 per 100 catheter-days, respectively. Medical salvage procedures, ie, intracatheter thrombolytic agent use or antibiotic therapy (52.1%) and interventional radiologic catheter salvage procedures (47.1%), increased catheter survival by an average of 54.8 days (range, 0-959 d). CONCLUSIONS: Radiologic placement of tunneled hemodialysis catheters is a safe and technically successful procedure in pediatric patients. However, there is a high rate of infectious and mechanical complications, particularly in younger and smaller patients.


Assuntos
Cateterismo Venoso Central/instrumentação , Cateteres de Demora , Veias Jugulares/diagnóstico por imagem , Radiografia Intervencionista , Diálise Renal , Adolescente , Adulto , Fatores Etários , Peso Corporal , Infecções Relacionadas a Cateter/etiologia , Cateterismo Venoso Central/efeitos adversos , Cateteres de Demora/efeitos adversos , Criança , Pré-Escolar , Desenho de Equipamento , Falha de Equipamento , Feminino , Humanos , Lactente , Estimativa de Kaplan-Meier , Masculino , Razão de Chances , Philadelphia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
12.
BMJ Surg Interv Health Technol ; 4(Suppl 1): e000123, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36393894

RESUMO

Objectives: Generating and using real-world evidence (RWE) is a pragmatic solution for evaluating health technologies. RWE is recognized by regulators, health technology assessors, clinicians, and manufacturers as a valid source of information to support their decision-making. Well-designed registries can provide RWE and become more powerful when linked with electronic health records and administrative databases in coordinated registry networks (CRNs). Our objective was to create a framework of maturity of CRNs and registries, so guiding their development and the prioritization of funding. Design setting and participants: We invited 52 stakeholders from diverse backgrounds including patient advocacy groups, academic, clinical, industry and regulatory experts to participate on a Delphi survey. Of those invited, 42 participated in the survey to provide feedback on the maturity framework for CRNs and registries. An expert panel reviewed the responses to refine the framework until the target consensus of 80% was reached. Two rounds of the Delphi were distributed via Qualtrics online platform from July to August 2020 and from October to November 2020. Main outcome measures: Consensus on the maturity framework for CRNs and registries consisted of seven domains (unique device identification, efficient data collection, data quality, product life cycle approach, governance and sustainability, quality improvement, and patient-reported outcomes), each presented with five levels of maturity. Results: Of 52 invited experts, 41 (79.9%) responded to round 1; all 41 responded to round 2; and consensus was reached for most domains. The expert panel resolved the disagreements and final consensus estimates ranged from 80.5% to 92.7% for seven domains. Conclusions: We have developed a robust framework to assess the maturity of any CRN (or registry) to provide reliable RWE. This framework will promote harmonization of approaches to RWE generation across different disciplines and health systems. The domains and their levels may evolve over time as new solutions become available.

13.
J Vasc Interv Radiol ; 20(3): 368-73, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19157908

RESUMO

PURPOSE: To review outcomes of ultrasound (US)-guided percutaneous submandibular gland injection of botulinum toxin A (BTX-A) in the treatment of drooling and chronic aspiration. MATERIALS AND METHODS: A 3-year retrospective review was performed of 220 US-guided salivary gland injections in 36 patients. There were 21 male patients and 15 female patients with an age range of 1.4 to 19.8 years (mean, 8.6 y) and a weight range of 7.8 to 73 kg (mean, 24.4 kg). The mean pretreatment analysis period was 48 months and the mean follow-up period was 21 months. The study group was divided into groups with anterior (n = 9) and posterior (n = 27) drooling, with those with both (n = 10) included in the posterior group. RESULTS: All procedures were technically successful. Bilateral submandibular injections were performed in 34 procedures and bilateral submandibular and parotid injections were performed in 38 procedures. Of the 27 patients with posterior drooling, improvement occurred in 24 patients (88%), no improvement was seen in two (8%), and one (4%) was lost to follow-up. Of the nine patients with anterior drooling, six (66%) showed improvement, there was no response in two (22%), and one (12%) was lost to follow-up. The total number of hospitalizations for respiratory issues and presumed aspiration pneumonia decreased by 56.4% per year in the patients with posterior drooling. There was one procedure-related complication: an episode of self-limited oral bleeding. CONCLUSION: Salivary gland BTX-A injection for salivary control shows promising results in decreasing saliva production and frequency of respiratory symptoms in children with drooling and chronic aspiration.


Assuntos
Toxinas Botulínicas Tipo A/administração & dosagem , Pneumonia Aspirativa/diagnóstico por imagem , Pneumonia Aspirativa/prevenção & controle , Sialorreia/diagnóstico por imagem , Sialorreia/prevenção & controle , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Injeções , Masculino , Fármacos Neuromusculares/administração & dosagem , Pneumonia Aspirativa/complicações , Estudos Retrospectivos , Glândulas Salivares , Sialorreia/complicações , Resultado do Tratamento , Ultrassonografia , Adulto Jovem
16.
JPEN J Parenter Enteral Nutr ; 43(5): 591-614, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31006886

RESUMO

Children with chronic illness often require prolonged or repeated venous access. They remain at high risk for venous catheter-related complications (high-risk patients), which largely derive from elective decisions during catheter insertion and continuing care. These complications result in progressive loss of the venous capital (patent and compliant venous pathways) necessary for delivery of life-preserving therapies. A nonstandardized, episodic, isolated approach to venous care in these high-need, high-cost patients is too often the norm, imposing a disproportionate burden on affected persons and escalating costs. This state-of-the-art review identifies known failure points in the current systems of venous care, details the elements of an individualized plan of care, and emphasizes a patient-centered, multidisciplinary, collaborative, and evidence-based approach to care in these vulnerable populations. These guidelines are intended to enable every practitioner in every practice to deliver better care and better outcomes to these patients through awareness of critical issues, anticipatory attention to meaningful components of care, and appropriate consultation or referral when necessary.


Assuntos
Infecções Relacionadas a Cateter/prevenção & controle , Cateterismo Venoso Central/métodos , Medicina Baseada em Evidências/métodos , Criança , Humanos , Pediatria , Encaminhamento e Consulta
17.
Clin J Am Soc Nephrol ; 13(3): 495-500, 2018 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-28729382

RESUMO

Central venous catheters are used frequently in patients on hemodialysis as a bridge to a permanent vascular access. They are prone to frequent complications, including catheter-related bloodstream infection, catheter dysfunction, and central vein obstruction. There is a compelling need to develop new drugs or devices to prevent central venous catheter complications. We convened a multidisciplinary panel of experts to propose standardized definitions of catheter end points to guide the design of future clinical trials seeking approval from the Food and Drug Administration. Our workgroup suggests diagnosing catheter-related bloodstream infection in catheter-dependent patients on hemodialysis with a clinical suspicion of infection (fever, rigors, altered mental status, or unexplained hypotension), blood cultures growing the same organism from the catheter hub and a peripheral vein (or the dialysis bloodline), and absence of evidence for an alternative source of infection. Catheter dysfunction is defined as the inability of a central venous catheter to (1) complete a single dialysis session without triggering recurrent pressure alarms or (2) reproducibly deliver a mean dialysis blood flow of >300 ml/min (with arterial and venous pressures being within the hemodialysis unit parameters) on two consecutive dialysis sessions or provide a Kt/V≥1.2 in 4 hours or less. Catheter dysfunction is defined only if it persists, despite attempts to reposition the patient, reverse the arterial and venous lines, or forcefully flush the catheter. Central vein obstruction is suspected in patients with >70% stenosis of a central vein by contrast venography or the equivalent, ipsilateral upper extremity edema, and an existing or prior history of a central venous catheter. There is some uncertainty about the specific criteria for these diagnoses, and the workgroup has also proposed future high-priority studies to resolve these questions.


Assuntos
Obstrução do Cateter , Infecções Relacionadas a Cateter/diagnóstico , Cateteres de Demora/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Determinação de Ponto Final , Doenças Vasculares/diagnóstico , Infecções Relacionadas a Cateter/etiologia , Ensaios Clínicos como Assunto , Humanos , Diálise Renal
18.
AJR Am J Roentgenol ; 188(1): 182-6, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17179362

RESUMO

OBJECTIVE: The purposes of this study were to retrospectively review an injection technique, to develop a grading system for evaluation of imaging findings, and to report preliminary outcome related to percutaneous CT-guided steroid injection into the temporomandibular joints of children with inflammatory arthropathy. CONCLUSION: CT-guided steroid injection into the temporomandibular joint of children with inflammatory arthropathy results in clinical and imaging improvement in a substantial proportion of children treated.


Assuntos
Artrite Juvenil/diagnóstico por imagem , Artrite Juvenil/tratamento farmacológico , Injeções Subcutâneas/métodos , Esteroides/administração & dosagem , Transtornos da Articulação Temporomandibular/diagnóstico por imagem , Transtornos da Articulação Temporomandibular/tratamento farmacológico , Tomografia Computadorizada por Raios X/métodos , Adolescente , Anti-Inflamatórios/administração & dosagem , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
19.
Healthc (Amst) ; 5(4): 158-164, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27939170

RESUMO

The Medical Device Epidemiology Network (MDEpiNet) is a public private partnership (PPP) that provides a platform for collaboration on medical device evaluation and depth of expertise for supporting pilots to capture, exchange and use device information for improving device safety and protecting public health. The MDEpiNet SMART Think Tank, held in February, 2013, sought to engage expert stakeholders who were committed to improving the capture of device data, including Unique Device Identification (UDI), in key electronic health information. Prior to the Think Tank there was limited collaboration among stakeholders beyond a few single health care organizations engaged in electronic capture and exchange of device data. The Think Tank resulted in what has become two sustainable multi-stakeholder device data capture initiatives, BUILD and VANGUARD. These initiatives continue to mature within the MDEpiNet PPP structure and are well aligned with the goals outlined in recent FDA-initiated National Medical Device Planning Board and Medical Device Registry Task Force white papers as well as the vision for the National Evaluation System for health Technology.%.


Assuntos
Comportamento Cooperativo , Desenho de Equipamento/métodos , Equipamentos e Provisões/normas , Comitês Consultivos/tendências , Desenho de Equipamento/normas , Segurança de Equipamentos/normas , Segurança de Equipamentos/tendências , Humanos , Estados Unidos , United States Food and Drug Administration/organização & administração , United States Food and Drug Administration/tendências
SELEÇÃO DE REFERÊNCIAS