Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 25(7): e14338, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38610118

RESUMO

PURPOSE: Volumetric-modulated arc therapy (VMAT) is a widely accepted treatment method for head and neck (HN) and cervical cancers; however, creating contours and plan optimization for VMAT plans is a time-consuming process. Our group has created an automated treatment planning tool, the Radiation Planning Assistant (RPA), that uses deep learning models to generate organs at risk (OARs), planning structures and automates plan optimization. This study quantitatively evaluates the quality of contours generated by the RPA tool. METHODS: For patients with HN (54) and cervical (39) cancers, we retrospectively generated autoplans using the RPA. Autoplans were generated using deep-learning and RapidPlan models developed in-house. The autoplans were, then, applied to the original, physician-drawn contours, which were used as a ground truth (GT) to compare with the autocontours (RPA). Using a "two one-sided tests" (TOST) procedure, we evaluated whether the autocontour normal tissue dose was equivalent to that of the ground truth by a margin, δ, that we determined based on clinical judgement. We also calculated the number of plans that met established clinically accepted dosimetric criteria. RESULTS: For HN plans, 91.8% and 91.7% of structures met dosimetric criteria for automatic and manual contours, respectively; for cervical plans, 95.6% and 95.7% of structures met dosimetric criteria for automatic and manual contours, respectively. Autocontours were equivalent to the ground truth for 71% and 75% of common DVH metrics for the HN and cervix, respectively. CONCLUSIONS: This study shows that dosimetrically equivalent normal tissue contours can be created for HN and cervical cancers using deep learning techniques. In general, differences between the contours did not affect the passing or failing of clinical dose tolerances.


Assuntos
Neoplasias de Cabeça e Pescoço , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Neoplasias do Colo do Útero , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias de Cabeça e Pescoço/radioterapia , Radioterapia de Intensidade Modulada/métodos , Órgãos em Risco/efeitos da radiação , Feminino , Estudos Retrospectivos , Neoplasias do Colo do Útero/radioterapia , Aprendizado Profundo , Algoritmos
2.
J Appl Clin Med Phys ; : e14474, 2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39074490

RESUMO

BACKGROUND: The delineation of clinical target volumes (CTVs) for radiotherapy for nasopharyngeal cancer is complex and varies based on the location and extent of disease. PURPOSE: The current study aimed to develop an auto-contouring solution following one protocol guidelines (NRG-HN001) that can be adjusted to meet other guidelines, such as RTOG-0225 and the 2018 International guidelines. METHODS: The study used 2-channel 3-dimensional U-Net and nnU-Net framework to auto-contour 27 normal structures in the head and neck (H&N) region that are used to define CTVs in the protocol. To define the CTV-Expansion (CTV1 and CTV2) and CTV-Overall (the outer envelope of all the CTV contours), we used adjustable morphological geometric landmarks and mimicked physician interpretation of the protocol rules by partially or fully including select anatomic structures. The results were evaluated quantitatively using the dice similarity coefficient (DSC) and mean surface distance (MSD) and qualitatively by independent reviews by two H&N radiation oncologists. RESULTS: The auto-contouring tool showed high accuracy for nasopharyngeal CTVs. Comparison between auto-contours and clinical contours for 19 patients with cancers of various stages showed a DSC of 0.94 ± 0.02 and MSD of 0.4 ± 0.4 mm for CTV-Expansion and a DSC of 0.83 ± 0.02 and MSD of 2.4 ± 0.5 mm for CTV-Overall. Upon independent review, two H&N physicians found the auto-contours to be usable without edits in 85% and 75% of cases. In 15% of cases, minor edits were required by both physicians. Thus, one physician rated 100% of the auto-contours as usable (use as is, or after minor edits), while the other physician rated 90% as usable. The second physician required major edits in 10% of cases. CONCLUSIONS: The study demonstrates the ability of an auto-contouring tool to reliably delineate nasopharyngeal CTVs based on protocol guidelines. The tool was found to be clinically acceptable by two H&N radiation oncology physicians in at least 90% of the cases.

3.
JCO Glob Oncol ; 10: e2300376, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38484191

RESUMO

PURPOSE: Increased automation has been identified as one approach to improving global cancer care. The Radiation Planning Assistant (RPA) is a web-based tool offering automated radiotherapy (RT) contouring and planning to low-resource clinics. In this study, the RPA workflow and clinical acceptability were assessed by physicians around the world. METHODS: The RPA output for 75 cases was reviewed by at least three physicians; 31 radiation oncologists at 16 institutions in six countries on five continents reviewed RPA contours and plans for clinical acceptability using a 5-point Likert scale. RESULTS: For cervical cancer, RPA plans using bony landmarks were scored as usable as-is in 81% (with minor edits 93%); using soft tissue contours, plans were scored as usable as-is in 79% (with minor edits 96%). For postmastectomy breast cancer, RPA plans were scored as usable as-is in 44% (with minor edits 91%). For whole-brain treatment, RPA plans were scored as usable as-is in 67% (with minor edits 99%). For head/neck cancer, the normal tissue autocontours were acceptable as-is in 89% (with minor edits 97%). The clinical target volumes (CTVs) were acceptable as-is in 40% (with minor edits 93%). The volumetric-modulated arc therapy (VMAT) plans were acceptable as-is in 87% (with minor edits 96%). For cervical cancer, the normal tissue autocontours were acceptable as-is in 92% (with minor edits 99%). The CTVs for cervical cancer were scored as acceptable as-is in 83% (with minor edits 92%). The VMAT plans for cervical cancer were acceptable as-is in 99% (with minor edits 100%). CONCLUSION: The RPA, a web-based tool designed to improve access to high-quality RT in low-resource settings, has high rates of clinical acceptability by practicing clinicians around the world. It has significant potential for successful implementation in low-resource clinics.


Assuntos
Neoplasias da Mama , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias da Mama/cirurgia , Inteligência Artificial , Neoplasias do Colo do Útero/radioterapia , Planejamento da Radioterapia Assistida por Computador , Mastectomia
4.
Clin Transl Radiat Oncol ; 44: 100700, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38058404

RESUMO

Purpose/Objectives: The purpose of this study was to evaluate patterns of locoregional recurrence (LRR) after surgical salvage and adjuvant reirradiation with IMRT for recurrent head and neck squamous cell cancer (HNSCC). Materials/Methods: Patterns of LRR for 61 patients treated consecutively between 2003 and 2014 who received post-operative IMRT reirradiation to ≥ 60 Gy for recurrent HNSCC were determined by 2 methods: 1) physician classification via visual comparison of post-radiotherapy imaging to reirradiation plans; and 2) using deformable image registration (DIR). Those without evaluable CT planning image data were excluded. All recurrences were verified by biopsy or radiological progression. Failures were defined as in-field, marginal, or out-of-field. Logistic regression analyses were performed to identify predictors for LRR. Results: A total of 55 patients were eligible for analysis and 23 (42 %) had documented LRR after reirradiation. Location of recurrent disease prior to salvage surgery (lymphatic vs. mucosal) was the most significant predictor of LRR after post-operative reirradiation with salvage rate of 67 % for lymphatic vs. 33 % for mucosal sites (p = 0.037). Physician classification of LRR yielded 14 (61 %) in-field failures, 3 (13 %) marginal failures, and 6 (26 %) out-of-field failures, while DIR yielded 10 (44 %) in-field failures, 4 (17 %) marginal failures, and 9 (39 %) out-of-field failures. Most failures (57 %) occurred within the original site of recurrence or first echelon lymphatic drainage. Of patients who had a free flap placed during salvage surgery, 56 % of failures occurred within 1 cm of the surgical flap. Conclusion: Our study highlights the role of DIR in enhancing the accuracy and consistency of POF analysis. Compared to traditional visual inspection, DIR reduces interobserver variability and provides more nuanced insights into dose-specific and spatial parameters of locoregional recurrences. Additionally, the study identifies the location of the initial recurrence as a key predictor of subsequent locoregional recurrence after salvage surgery and re-IMRT.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa