Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Electrocardiol ; 60: 184-187, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32413693

RESUMO

Abnormal P-wave axis (PWA) has emerged as a novel marker of risk for both cardiovascular disease (CVD) and all-cause mortality (ACM) in the general population, though this relationship has not been adequately explored among those with type 2 diabetes (DM2). We aimed to explore the association between abnormal PWA and ACM among a large, well-phenotyped group of participants with DM2 from the Action to Control Cardiovascular Risk in Diabetes (ACCORD) trial. This analysis included 8899 ACCORD participants with available PWA data on baseline electrocardiogram. Cox proportional hazards models were used to examine the association between PWA and ACM in models adjusted for demographics, ACCORD trial treatment assignment, and potential confounders. PWA was modeled as either normal (0° -75°) or abnormal (<0° or >75°). Over 44,000 person-years of follow up, there were 609 deaths. Participants with abnormal PWA had increased risk of ACM (HR 1.61, 95% CI 1.25-2.08). After multivariable adjustment, the association remained significant (HR 1.33, 95% CI 1.03-1.72). This relationship was similar in subgroups stratified by age, race, sex, and history of CVD. Among ACCORD trial participants, abnormal PWA was associated with an increased risk of mortality. Abnormal PWA may have added value beyond traditional risk factors in prediction models.


Assuntos
Doenças Cardiovasculares , Diabetes Mellitus Tipo 2 , Diabetes Mellitus Tipo 2/tratamento farmacológico , Eletrocardiografia , Humanos , Modelos de Riscos Proporcionais , Fatores de Risco
3.
J Am Heart Assoc ; 11(19): e026198, 2022 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-36129031

RESUMO

Background Methohexital and propofol can both be used as sedation for direct current cardioversion (DCCV). However, there are limited data comparing these medications in this setting. We hypothesized that patients receiving methohexital for elective DCCV would be sedated more quickly, recover from sedation faster, and experience less adverse effects. Methods and Results This was a prospective, blinded randomized controlled trial conducted at a single academic medical center. Eligible participants were randomly assigned to receive either methohexital (0.5 mg/kg) or propofol (0.8 mg/kg) as a bolus for elective DCCV. The times from bolus of the medication to achieving a Ramsay Sedation Scale score of 5 to 6, first shock, eyes opening on command, and when the patient could state their age and name were obtained. The need for additional medication dosing, airway intervention, vital signs, and medication side effects were also recorded. Seventy patients who were randomized to receive methohexital (n=37) or propofol (n=33) were included for analysis. The average doses of methohexital and propofol were 0.51 mg/kg and 0.84 mg/kg, respectively. There were no significant differences between methohexital and propofol in the time from end of injection to loss of conscious (1.4±1.8 versus 1.1±0.5 minutes; P=0.33) or the time to first shock (1.7±1.9 versus 1.4±0.5 minutes; P=0.31). Time intervals were significantly lower for methohexital compared with propofol in the time to eyes opening on command (5.1±2.5 versus 7.8±3.7 minutes; P=0.0005) as well as at the time to the ability to answer simple questions of age and name (6.0±2.6 versus 8.6±4.0 minutes; P=0.001). The methohexital group experienced less hypotension (8.1% versus 42.4%; P<0.001) and less hypoxemia (0.0% versus 15.2%; P=0.005), had lower need for jaw thrust/chin lift (16.2% versus 42.4%; P=0.015), and had less pain on injection compared with propofol using the visual analog scale (7.2±9.7 versus 22.4±28.1; P=0.003). Conclusions In this model of fixed bolus dosing, methohexital was associated with faster recovery, more stable hemodynamics, and less hypoxemia after elective DCCV compared with propofol. It can be considered as a preferred agent for sedation for DCCV. Registration URL: https://www.clinicaltrials.gov/ct; Unique identifier: NCT04187196.


Assuntos
Metoexital , Propofol , Cardioversão Elétrica/efeitos adversos , Humanos , Hipóxia , Propofol/efeitos adversos , Estudos Prospectivos
4.
J Interv Card Electrophysiol ; 63(3): 531-544, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34424446

RESUMO

BACKGROUND: The ideal treatment of inappropriate sinus tachycardia (IST) and postural orthostatic tachycardia syndrome (POTS) still needs to be defined. Medical treatments yield suboptimal results. Endocardial catheter ablation of the sinus node (SN) may risk phrenic nerve damage and open-heart surgery may be accompanied by unjustified invasive risks. METHODS: We describe our first multicenter experience of 255 consecutive patients (235 females, 25.94 ± 3.84 years) having undergone a novel SN sparing hybrid thoracoscopic ablation for drug-resistant IST (n = 204, 80%) or POTS (n = 51, 20%). As previously described, the SN was identified with 3D mapping. Surgery was performed through three 5-mm ports from the right side. A minimally invasive approach with a bipolar radiofrequency clamp was used to ablate targeted areas while sparing the SN region. The targeted areas included isolation of the superior and the inferior caval veins, and a crista terminalis line was made. All lines were interconnected. RESULTS: Normal sinus rhythm (SR) was restored in all patients at the end of the procedure. All patients discontinued medication during the follow-up. After a blanking period of 6 months, all patients presented stable SR. At a mean of 4.07 ± 1.8 years, normal SN reduction and chronotropic response to exercise were present. In the 51 patients initially diagnosed with POTS, no syncope occurred. During follow-up, pericarditis was the most common complication (121 patients: 47%), with complete resolution in all cases. Pneumothorax was observed in 5 patients (1.9%), only 3 (1.1%) required surgical drainage. Five patients (1.9%) required a dual-chamber pacemaker due to sinus arrest > 5 s. CONCLUSIONS: Preliminary results of this multicenter experience with a novel SN sparing hybrid ablation of IST/POTS, using surgical thoracoscopic video-assisted epicardial ablation combined with simultaneous endocardial 3D mapping may prove to be an efficient and safe therapeutic option in patients with symptomatic drug-resistant IST and POTS. Importantly, in our study, all patients had a complete resolution of the symptoms and restored normal SN activity.


Assuntos
Ablação por Cateter , Síndrome da Taquicardia Postural Ortostática , Ablação por Cateter/métodos , Endocárdio/cirurgia , Feminino , Humanos , Síndrome da Taquicardia Postural Ortostática/diagnóstico , Nó Sinoatrial/cirurgia , Taquicardia Sinusal/diagnóstico
5.
J Innov Card Rhythm Manag ; 12(5): 4501-4505, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34035982

RESUMO

Ventricular tachycardia storm is associated with high mortality rates and is often refractory to treatment. Historically, few options for treatment have existed in cases when antiarrhythmic drugs fail. We report the case of a patient with incessant ventricular fibrillation (VF) in the postinfarction period that was triggered by premature ventricular contractions (PVCs) that persisted despite normal electrolytes, exclusion of ongoing ischemia, infusions of antiarrhythmic drugs, general anesthesia, full circulatory support with extracorporeal membranous oxygenation, and cardiac sympathetic denervation. Given that the VF appeared to be triggered consistently by a unifocal, short-coupled PVC (consistent with Purkinje fiber-mediated VF), we performed catheter ablation, after which point, the patient experienced no further PVCs or ventricular arrhythmia. This case serves as a reminder of three key teaching points. First, not all VF is created equal, with some cases being chiefly the result of a vulnerable substrate and others being best accounted for by frequent triggers. Second, examining the available electrocardiographic data and appropriately interpreting them can guide the selection of therapies up to and including catheter ablation for treatment-refractory VF. Third, full circulatory support greatly facilitates successful electroanatomic mapping and catheter ablation of unstable ventricular arrhythmias.

6.
EuroIntervention ; 17(12): e1033-e1040, 2021 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-34219662

RESUMO

BACKGROUND: Residual peri-device leakage (PDL) is frequent after left atrial appendage occlusion (LAAO). Little is known about management strategies, procedural aspects and outcomes of interventional PDL closure. AIMS: The aim of this study was to assess the safety and feasibility of PDL closure after LAAO. METHODS: Fifteen centres contributed data on baseline characteristics, in-hospital and follow-up outcomes of patients who underwent PDL closure after LAAO. Outcomes of interest included acute success and complication rates and long-term efficacy of the procedure. RESULTS: A total of 95 patients were included and a cumulative number of 104 leaks were closed. The majority of PDLs were detected within 90 days (range 41-231). Detachable coils were the most frequent approach (42.3%), followed by the use of the AMPLATZER Vascular Plug II (29.8%) and the AMPLATZER Duct Occluder II (17.3%). Technical success was 100% with 94.2% of devices placed successfully within the first attempt. There were no major complications requiring surgical or transcatheter interventions. During follow-up (96 days [range 49-526]), persistent leaks were found in 18 patients (18.9%), yielding a functional success rate of 82.7%, although PDLs were significantly reduced in size (pre-leak sizemax: 6.1±3.6 mm vs post-leak sizemax: 2.5±1.3 mm, p<0.001). None of the patients had a leak >5 mm. Major adverse events during follow-up occurred in 5 patients (2 ischaemic strokes, 2 intracranial haemorrhages, and 1 major gastrointestinal bleeding). CONCLUSIONS: Several interventional techniques have become available to achieve PDL closure. They are associated with high technical and functional success and low complication rates.


Assuntos
Dispositivo para Oclusão Septal , Estudos de Viabilidade , Humanos , Dispositivo para Oclusão Septal/efeitos adversos
7.
Am J Cardiol ; 128: 191-195, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32650919

RESUMO

Abnormal P-wave axis may reflect preclinical atrial dysfunction and has been associated with an increased risk of incident atrial fibrillation (AF) in the general population. Patients with diabetes mellitus (DM) have a higher prevalence of AF, but the association of abnormal P-wave axis and the risk of incident AF in those with diabetes has not been previously explored. For this analysis, we included 8,965 eligible participants from the Action to Control Cardiovascular Risk in Diabetes (ACCORD) trial. P-wave axis was automatically measured on study electrocardiogram and visually confirmed, with the normal range being between 0° and 75°. At baseline, 8% of the study population had an abnormal P-wave axis. During 43,856 person-years of follow-up, there were 145 cases of incident AF. Using multivariable-adjusted Cox proportional hazards models, participants with abnormal P-wave axis had an increased risk of incident AF (hazard ratio 2.65, 95% confidence interval 1.76 to 3.99, p < 0.0001). Findings were similar in prespecified subgroups, without evidence of effect modification. Both left- and right-axis deviation of the P-wave were associated with incident AF. Our results suggest that abnormal P-wave axis is associated with incident AF in those with DM and that this relation is conserved in prespecified subgroups. There may be utility in considering P-wave axis values from routine ECGs in these patients.


Assuntos
Fibrilação Atrial/epidemiologia , Diabetes Mellitus Tipo 2/epidemiologia , Átrios do Coração/fisiopatologia , Idoso , Fibrilação Atrial/fisiopatologia , Comorbidade , Diabetes Mellitus Tipo 2/fisiopatologia , Eletrocardiografia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco
9.
J Innov Card Rhythm Manag ; 9(8): 3291-3296, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32494503

RESUMO

As the number and complexity of cardiovascular implantable electronic devices has increased, so too has the incidence of device-related infections. Such a rise requires that the focus be directed toward developing universal standards for infected lead removal. To date, no consensus currently exists regarding the optimal management of patients with large vegetations (diameter > 2 cm). In these individuals, medical therapy is universally ineffective and they are often too ill for surgical extraction; furthermore, transvenous lead extraction (TLE) carries with it a risk of large septic pulmonary emboli. We present a series of five cases in which the AngioVac thrombectomy system (AngioDynamics Inc., Latham, NY, USA) was used as an adjunct to TLE. Debridement of infected leads prior to percutaneous lead extraction was accomplished as either a bridge to or as concomitant therapy with laser lead removal at our institution. This study included three males and two females with an average age of 52 years. The sizes of vegetations removed from leads ranged from 1.5 cm to 3.9 cm in the largest dimension and the average diameter was 2.65 cm ± 1.1 cm. The vegetations were successfully debulked in all five patients. This suggests that TLE performed with assistance from the AngioVac system (AngioDynamics Inc., Latham, NY, USA) is a safe and effective alternative to open surgical lead removal in patients with large lead vegetations.

11.
Tex Heart Inst J ; 41(6): 620-5, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25593527

RESUMO

Cardiac tumors can lead to distinct electrocardiographic changes and ventricular arrhythmias. Benign and malignant cardiac tumors have been associated with ventricular tachycardia. When possible, benign tumors should be resected when ventricular arrhythmias are intractable. Chemotherapy can shrink malignant tumors and eliminate arrhythmias. We report the case of a 52-year-old woman with breast sarcoma whom we diagnosed with myocardial metastasis after she presented with palpitations. The initial electrocardiogram revealed sinus rhythm with new right bundle branch block and ST-segment elevation in the anterior precordial leads. During telemetry, hemodynamically stable, sustained ventricular tachycardia with right ventricular localization was detected. Images showed a myocardial mass in the right ventricular free wall. Amiodarone suppressed the arrhythmia. To our knowledge, this is the first report of ventricular tachycardia associated with radiation-induced undifferentiated sarcoma. We discuss the distinct electrocardiographic changes and ventricular arrhythmias that can be associated with cardiac tumors, and we review the relevant medical literature.


Assuntos
Neoplasias da Mama/radioterapia , Neoplasias Cardíacas/complicações , Frequência Cardíaca , Neoplasias Induzidas por Radiação/complicações , Sarcoma/complicações , Taquicardia Ventricular/etiologia , Amiodarona/uso terapêutico , Antiarrítmicos/uso terapêutico , Ecocardiografia , Eletrocardiografia , Feminino , Neoplasias Cardíacas/diagnóstico , Neoplasias Cardíacas/terapia , Frequência Cardíaca/efeitos dos fármacos , Humanos , Pessoa de Meia-Idade , Neoplasias Induzidas por Radiação/diagnóstico , Neoplasias Induzidas por Radiação/terapia , Valor Preditivo dos Testes , Radioterapia/efeitos adversos , Sarcoma/diagnóstico , Sarcoma/terapia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/tratamento farmacológico , Taquicardia Ventricular/fisiopatologia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa