Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 103(6): 1004-1014, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38577939

RESUMO

INTRODUCTION: Bicuspid aortic valve (BAV) stenosis is a complex anatomical scenario for transcatheter aortic valve implantation (TAVI). Favorable short-term clinical outcomes have been reported with TAVI in this setting, but long-term data are scarce. METHODS: We retrospectively included, in a single-center registry, patients with BAV stenosis who underwent TAVI before 2020. We compared patients treated with self-expanding valves (SEV) versus balloon-expandable valves (BEV). The primary endpoint was a composite of all-cause mortality, stroke and need for aortic valve (AV) reintervention at 3 years. Secondary endpoints included each component of the primary endpoint, cardiovascular mortality, permanent pacemaker implantation (PPI) rate, mean gradient and ≥moderate paravalvular leak (PVL) rate. RESULTS: A total of 150 consecutive patients (SEV = 83, BEV = 67) were included. No significant differences were reported between SEV and BEV groups for the primary composite endpoint (SEV 35.9% vs. BEV 32%, p = 0.66), neither for clinical secondary endpoints (all-cause mortality SEV 28.1% vs. BEV 28%, p = 0.988; cardiovascular mortality SEV 14.1% vs. BEV 20%, p = 0.399; stroke SEV 12.5% vs. BEV 6%, p = 0.342; need for AV reintervention SEV 0% vs. BEV 0%; PPI SEV 28.1% vs. BEV 24%, p = 0.620). A lower mean gradient persisted up to 3 years in the SEV group (SEV 8.8 ± 3.8 mmHg vs. BEV 10.7 ± 3.2 mmHg, p = 0.063), while no significant difference was found in the rate of ≥ moderate PVL (SEV 3/30 vs. BEV 0/25, p = 0.242). CONCLUSIONS: In this single center registry, we observed favorable 3-year clinical outcomes in nonselected BAV patients treated with different generation devices, without significant differences between patients receiving SEV or BEV.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Doença da Válvula Aórtica Bicúspide , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Masculino , Feminino , Estudos Retrospectivos , Resultado do Tratamento , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Fatores de Tempo , Idoso , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Idoso de 80 Anos ou mais , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/anormalidades , Recuperação de Função Fisiológica , Hemodinâmica , Medição de Risco
2.
Am Heart J ; 255: 94-105, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36272451

RESUMO

BACKGROUND: Several electrocardiogram (ECG) criteria have been proposed to predict the location of the culprit occlusion in specific subsets of patients presenting with ST-segment elevation myocardial infarction (STEMI). The aim of this study was to develop, through an independent validation of currently available criteria, a comprehensive and easy-to-use ECG algorithm, and to test its diagnostic performance in real-world clinical practice. METHODS: We analyzed ECG and angiographic data from 419 consecutive STEMI patients submitted to primary percutaneous coronary intervention over a one-year period, dividing the overall population into derivation (314 patients) and validation (105 patients) cohorts. In the derivation cohort, we tested >60 previously published ECG criteria, using the decision-tree analysis to develop the algorithm that would best predict the infarct-related artery (IRA) and its occlusion level. We further assessed the new algorithm diagnostic performance in the validation cohort. RESULTS: In the derivation cohort, the algorithm correctly predicted the IRA in 88% of cases and both the IRA and its occlusion level (proximal vs mid-distal) in 71% of cases. When applied to the validation cohort, the algorithm resulted in 88% and 67% diagnostic accuracies, respectively. In a real-world comparative test, the algorithm performed significantly better than expert physicians in identifying the site of the culprit occlusion (P = .026 vs best cardiologist and P < .001 vs best emergency medicine doctor). CONCLUSIONS: Derived from an extensive literature review, this comprehensive and easy-to-use ECG algorithm can accurately predict the IRA and its occlusion level in all-comers STEMI patients.


Assuntos
Oclusão Coronária , Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Oclusão Coronária/complicações , Oclusão Coronária/diagnóstico , Angiografia Coronária , Infarto do Miocárdio/diagnóstico , Eletrocardiografia/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico
3.
Catheter Cardiovasc Interv ; 102(7): 1401-1405, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37694603

RESUMO

Valve-in-valve TAVI to treat failing surgical aortic valves (SAVs) is increasingly performed, and commissural alignment is a key technical aspect in such procedures. Surgeons optimize valve alignment, accounting for potential coronary eccentricity and achieving a patient-specific optimized commissural orientation, representing the ideal target for TAVI alignment. Therefore, here we present a dedicated stepwise valve-in-valve implantation technique using the ACURATE neo2. In a specific SAV postoverlap view, isolating one surgical post to the right of the screen representing the target for alignment, rotational orientation of the TAVI commissures, matching the SAV orientation, is achieved and verified before implantation. This technique has been tested in a patient-specific three-dimensionally-printed aortic root anatomy, attached to a pulsatile flow simulator, allowing for native-like simulation of coronary cannulations under fluoroscopy, and enabling detailed assessment with fluoroscopic as well as direct videographic visualization. Furthermore, the technique is exemplified by providing an educational clinical case example.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Desenho de Prótese
4.
Eur Heart J Suppl ; 25(Suppl I): I24-I31, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38093766

RESUMO

Monitoring of the patient supported with a temporary mechanical circulatory support (tMCS) is crucial in achieving the best possible outcome. Monitoring is a continuous and labour-intensive process, as cardiogenic shock (CS) patients can rapidly deteriorate and may require new interventions within a short time period. Echocardiography and invasive haemodynamic monitoring form the cornerstone of successful tMCS support. During monitoring, it is particularly important to ensure that adequate end-organ perfusion is achieved and maintained. Here, we provide a comprehensive overview of best practices for monitoring the CS patient supported by a micro-axial flow pump, veno-arterial extracorporeal membrane oxygenation, and both devices simultaneously (ECMELLA approach). It is a complex process that encompasses device control, haemodynamic control and stabilization, monitoring of interventions, and assessment of end-organ function. The combined, continuous, and preferably protocol-based approach of echocardiography, evaluation of biomarkers, end-organ assessment, and haemodynamic parameters is crucial in assessing this critically ill CS patient population.

5.
Catheter Cardiovasc Interv ; 99(7): 1976-1983, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35419933

RESUMO

BACKGROUND: In contemporary Cardiac Intensive Care Unit (CICU), bedside intra-aortic balloon pump (IABP) insertion under echocardiographic guidance may be an attractive option for selected patients with cardiogenic shock (CS). Currently available data on this approach are limited. AIM: This study aimed to assess the feasibility and safety of bedside IABP insertion, as compared to fluoroscopic-guided insertion in the Catheterization Laboratory (CathLab), and to describe the clinical features of patients receiving bedside IABP insertion using a standardized technique in real-world CICU practice. METHODS: We prospectively evaluated all patients admitted the CICU who received transfemoral IABP between June 2020 and October 2021. The overall study cohort was divided according to implant strategy in bedside and CathLab groups. The primary outcome was correct radiographic IABP positioning at the first bedside chest X-ray obtained after insertion. Secondary outcomes included IABP-related complications. RESULTS: Among 115 patients, bedside IABP insertion was performed in 35 (30.4%) cases, mainly presenting with CS-related to acute decompensated heart failure (ADHF) (68.6 vs 33.8%; p < 0.001), with lower LVEF, higher proportion of right ventricular involvement and higher need of inotropes/vasopressors, compared to those receiving CathLab insertion. Bedside IABP insertion resulted feasible and safe, with similar rates of correct IABP positioning (82.9 vs. 82.5%; p = 0.963) and IABP-related major vascular complications (5.7 vs. 5.0%; p = 0.874), as compared to CathLab positioning. CONCLUSION: This study suggests the feasibility and safety of bedside IABP insertion, which could be of relevant interest in patients with ADHF-related CS who may not need coronary angiography or other urgent CathLab procedures.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Insuficiência Cardíaca/etiologia , Coração Auxiliar/efeitos adversos , Humanos , Unidades de Terapia Intensiva , Balão Intra-Aórtico/efeitos adversos , Balão Intra-Aórtico/métodos , Estudos Retrospectivos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 98(3): E365-E369, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33851771

RESUMO

AIM: Coronary sinus (CS) reducer implantation is associated with symptomatic relief of patients with refractory angina. However, 15% to 30% of the patients do not respond to this treatment. Aim if this study was to evaluate the effect of CS size in the effectiveness of the device. METHODS: Prior to device implantation and at 4-month resting ventricular function was assessed by stress cardiac magnetic resonance. Ischemia was assessed by the myocardial perfusion reserve index (MPRI). RESULTS: Fifteen patients (66 ± 10 years) underwent successful CS Reducer implantation, with improvements in angina class and exercise tolerance. Patients with a smaller CS size (<5.8 mm) presented a significantly higher percentage increase in MPRI (63 ± 51 vs 9 ± 30%, P = .03) and a higher reduction in left ventricle end-diastolic volumes. CONCLUSIONS: Greater benefits, in terms of ischemia improvement, after CS Reducer implantation were seen in patients with smaller CS sizes, suggesting a potential mechanism underlying the observed rates of reducer non-responsiveness.


Assuntos
Seio Coronário , Angina Pectoris , Seio Coronário/diagnóstico por imagem , Tolerância ao Exercício , Humanos , Isquemia , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 98(2): E299-E305, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33315300

RESUMO

BACKGROUND: Prosthetic valve infolding is a rare but severe complication of transcatheter aortic valve implantation (TAVI) with self-expanding valves. However, currently available clinical data are limited and fragmented. OBJECTIVES: This report aims to provide a comprehensive overview of this complication focusing on predisposing factors, clinical presentation, diagnostic findings, treatment and clinical outcomes. METHODS: A systematic review of the literature was performed to identify cases of infolding occurring during TAVI with self-expanding valves published until August 2020. These data were pooled with all the retrospectively identified infolding cases occurred at San Raffaele Scientific Institute between December 2014 and August 2020. RESULTS: A total of 34 cases were included. Among patients with available data, 38% received a first-generation CoreValve, and 62% a second-generation Evolut R (82%) or Evolut PRO (18%). Infolding occurred mostly with ≥29-mm valves (94%). Predisposing factors included resheathing of a second-generation valve (82%), heavy calcification of the native valve (65%), lack of predilatation (16%), Sievers type-1 bicuspid aortic valve (11%), and improper valve loading (5%). Infolding resulted in severe PVL causing hemodynamic instability (29%) or cardiac arrest (12%). Postdilatation was the treatment strategy in 68%, while prosthesis replacement with a new device in 23% of cases. Device success rate was 82%. Death and stroke occurred in 3% and 12% of cases. CONCLUSIONS: Prosthetic valve infolding is typically observed after resheathing of a large-size self-expanding TAVI. When infolding is timely diagnosed, prosthesis removal and replacement should be pursued. Further studies are required to precisely define predisposing factors to prevent this complication.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Artif Organs ; 45(6): 569-576, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33277695

RESUMO

Extracorporeal membrane oxygenation (ECMO) represents a therapeutic option for cardiopulmonary support in patients with high-risk pulmonary embolism (PE); however, no definite consensus exists on ECMO use in high-risk PE. Hence, we aim to provide insights into its real-world use pooling together all available published experiences. We performed a systematic review and pooled analysis of all published studies (up to April 17, 2020) investigating ECMO support in high-risk PE. All studies including at least four patients were collectively analyzed. Study outcomes were early all-cause death (primary endpoint) and relevant in-hospital adverse events. A total of 21 studies were included in the pooled analysis (n = 635 patients). In this population (mean age 47.8 ± 17.3 years, 44.5% females), ECMO was indicated for cardiac arrest in 62.3% and immediate ECMO support was pursued in 61.9% of patients. Adjunctive reperfusion therapies were implemented in 57.0% of patients. Pooled estimate rate of early all-cause mortality was 41.1% (95% CI 27.7%-54.5%). The most common in-hospital adverse event was major bleeding, with an estimated rate of 28.6% (95%CI 21.0%-36.3%). At meta-regression analyses, no significant impact of multiple covariates on the primary endpoint was found. In this systematic review of patients who received ECMO for high-risk PE, pooled all-cause mortality was 41.1%. Principal indication for ECMO was cardiac arrest, cannulation was chiefly performed at presentation, and major bleeding was the most common complication.


Assuntos
Oxigenação por Membrana Extracorpórea , Embolia Pulmonar/terapia , Doença Aguda , Humanos
9.
Med Lav ; 112(2): 162-167, 2021 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-33881010

RESUMO

PURPOSE: We report a case of a 30 years old Indian sailor with microcytic anemia (Hb 9.9), persistent abdominal pain, emesis, dark stool, hyperchromic urine, latent jaundice and asthenia. Lead intoxication was confirmed (blood lead value of 102 µg/dL). The patient assumed Ayurvedic medicines in the previous months. Ayurveda is an ancient form of Indian traditional popular medicine aiming to re-establish health and body function through herbal preparations, heavy metals are often added. Our purpose was to treat the patient and to establish the source of poisoning. METHODS: After testing blood and urine lead concentration of other 3 crew members and analyzing over than 150 products used on the ship professional exposure was excluded. We analyzed the two Ayurvedic drugs assumed by the patient with an Inductively Coupled Plasma Mass Spectrometry. The patient underwent three chelation cycles with Calcium Disodium Ethylenediaminetetraacetic acid (EDTA) while monitoring blood and urinary lead levels. RESULTS: The final blood lead level at discharge, after three chelation cycles, was 36.27 µg/dL. One of the two drugs contained extremely high concentrations of lead and mercury. The three different mixtures of this preparation showed lead concentrations of 12,638.54 mg/kg (Sample 2A), 23,043.02 mg/kg (Sample 2B), 21,352.97 mg/kg (Sample 2C); these levels are much higher than the highest values reported in literature for the indian soil (32 mg/kg). CONCLUSIONS: This case and similar cases raise the safety alert on complementary and alternative medicines; Ayurvedic medicine users should be carefully informed about potential risks and signs of poisoning.


Assuntos
Intoxicação por Chumbo , Mercúrio , Adulto , Humanos , Chumbo , Intoxicação por Chumbo/diagnóstico , Intoxicação por Chumbo/tratamento farmacológico , Intoxicação por Chumbo/etiologia , Ayurveda , Preparações de Plantas
10.
Catheter Cardiovasc Interv ; 96(2): 255-265, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31905259

RESUMO

BACKGROUND: The ULISSE registry evaluated the real-world performance of the Ultimaster® biodegradable polymer sirolimus-eluting stent (BP-SES) in a multicenter-independent cohort of patients undergoing percutaneous coronary intervention, including a large proportion of diabetes mellitus (DM) patients. METHODS: In this subgroup analysis, 1,660 consecutive patients, 2,422 lesions, treated with BP-SES enrolled in the ULISSE registry were divided in two groups: DM (485 patients, 728 lesions) and non-DM (1,175 patients, 1,694 lesions). Primary endpoint was target lesion failure (TLF), a composite endpoint of cardiac-death, target-vessel myocardial infarction (TV-MI), and clinically driven target lesion revascularization (TLR) at 1-year. Secondary endpoint was TLR at 1-year. RESULTS: At 1-year follow-up TLF occurred in 5% overall patients and was significantly higher in DM patients (8 vs. 3.7%; p = .001), due to more cardiac deaths (3.4 vs. 1.1%; p = .002). TLR occurred in 3.2% overall patients, and it was not significantly higher in DM compared to non-DM patients (4.4 vs. 2.8%; p = .114). The incidence of stent thrombosis was low and similar between groups (0.4 vs. 0.9%; p = .526). Insulin-treated DM (ITDM) patients showed higher rate of TLF as compared to non-ITDM patients (13 vs. 6.5%; p = .041), but similar rate of TLR (6 vs. 4%; p = .405). After adjustment for relevant comorbidities, DM was not significantly associated with TLF or cardiac death in patients undergoing BP-SES implantation. CONCLUSIONS: This study is the first all-comers evaluation of BP-SES in DM patients. Our findings show that DM patients, mostly those with ITDM, still represent a vulnerable population and experience significantly higher rate of TLF. Overall BP-SES efficacy is considerable, although not statistically significant higher rate of TLR is still present in DM compared to non-DM patients.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidade , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
11.
Echocardiography ; 37(12): 2071-2081, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33026122

RESUMO

AIMS: Aortic stenosis (AS) grading by 2D-transthoracic echocardiography (2D-TTE) aortic valve area (AVA) calculation is limited by left ventricular outflow tract (LVOT) area underestimation. The combination of Doppler parameters with 3D LVOT area obtained by multidetector computed tomography (MDCT) can improve AS grading, reconciling discordant 2D-TTE findings. This study aimed to systematically evaluate the role of 3D-transesophageal echocardiography (3D-TEE) in AS grading using MDCT as reference standard. METHODS AND RESULTS: 288 patients (81 ± 6.3 years, 52.4% female) with symptomatic AS underwent 2D-TTE, 3D-TEE, and MDCT for transcatheter aortic valve implantation. Doppler parameters were combined with 3D LVOT areas measured by manual and semi-automated software 3D-TEE and by MDCT to calculate AVA, reassessing AS severity. Both 3D-TEE modalities demonstrated good correlation with MDCT, with excellent intra-observer and inter-observer variability. Compared to MDCT, 3D-TEE measurements significantly underestimated AVA (PANOVA  < .0001), although the difference was clinically acceptable. Compared to 2D-TTE, 3D-TEE manual and semi-automated software reclassified severe AS in 21.9% and 25.2% of cases, respectively (P < .0001), overcame grading parameters discordance in more than 40% of cases in patients with low-gradient AS (P < .0001) and reduced the proportion of low-flow states in nearly 75% of cases when combined to stroke volume index assessment (P < .0001). 3D-TEE imaging modalities showed a reduction in the proportion of patients with low-gradient and pathological AVA as defined by 2D-TTE, and improved AVA and mean pressure gradient agreement with current guidelines cutoff values. CONCLUSION: 3D-TEE AVA calculation is a reliable tool for AS grading with excellent reproducibility and good correlation with MDCT measurements.


Assuntos
Estenose da Valva Aórtica , Ecocardiografia Tridimensional , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes
12.
Catheter Cardiovasc Interv ; 94(7): 972-979, 2019 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-31037840

RESUMO

BACKGROUND: The ULISSE registry has demonstrated the real-world performance of the Ultimaster biodegradable polymer sirolimus-eluting stent (BP-SES) in a large cohort of patients undergoing percutaneous coronary intervention, including a large proportion of patients presenting with acute myocardial infarction (AMI). METHODS: We performed a subgroup analysis of the ULISSE registry in AMI patients and compared the outcomes of this vulnerable cohort with that of patients presenting without AMI (non-AMI). The primary end point was the incidence of 1-year target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (TV-MI), and clinically indicated target lesion revascularization (TLR). RESULTS: Of 1,660 patients included in the ULISSE registry, 381(23%) presented with AMI, 207(54.3%) non-ST elevation myocardial infarction, and 174(45.7%) ST-elevation myocardial infarction. Compared with non-AMI patients, those with AMI were more frequently female and smokers, with lower left ventricular ejection fraction (LVEF) and chronic kidney disease requiring dialysis. At 1 year, TLF rate was significantly higher in AMI than non-AMI patients (7.9 vs. 4.1%; HR 1.98, CI 95% 1.22-3.23; p = .005) driven by higher rate of cardiac death (4.0 vs. 1.1%; HR 3.59, CI 95% 1.64-7.88; p = .01) and TV-MI (2.8 vs 0.9%; HR 2.99,CI 95% 1.22-7.37; p = .01), without differences in TLR rate (4.3 vs. 2.9%,HR 0.66, CI95% 0.35-1.25; p = .2). At multivariate Cox regression analysis, eGFR <40 mL/min (HR: 2.868) and LVEF <40% (HR: 2.394) were the only independent predictors of TLF. CONCLUSIONS: In AMI patients, Ultimaster BP-SES implantation was associated with higher rate of TLF and definite stent thrombosis compared with non-AMI patients. The high incidence of adverse events was mainly driven by the unfavorable baseline risk profile.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Sirolimo/administração & dosagem , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Intervalo Livre de Progressão , Desenho de Prótese , Recidiva , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo
15.
JACC Case Rep ; 29(17): 102488, 2024 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-39359518

RESUMO

Acute myocardial infarction is a rare though possible occurrence in young patients, especially with predisposing conditions, and the treatment is still debated. We present the case of a teenager known to have neurofibromatosis type 1 with acute coronary syndrome caused by coronary aneurysms and thrombotic occlusion of the left circumflex artery treated with a stent-sparing strategy.

16.
Can J Cardiol ; 2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39179204

RESUMO

BACKGROUND: Coronary access (CA) and percutaneous coronary intervention (PCI) might be challenging after valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) with supra-annular self-expanding valves (SS-TAVs) in surgical aortic valves (SAVs). Our study aim was to compare feasibility, predictors, and techniques of CA and PCI following ViV-TAVR with ACURATE neo2 (Boston Scientific, Marlborough, MA) and Evolut PRO+ (Medtronic, Minneapolis, MN). METHODS: Fifteen computed tomography (CT)-based patient-specific aortic models were 3-dimensionally (3D) printed and implanted with specific SAVs and with the 2 SS-TAVs with commissural alignment. Two operators attempted CA (n = 120) and PCI (n = 120) of each coronary artery in a pulsatile-flow-simulator, under real catheterization laboratory conditions. The primary endpoints were the rate of successful CA and PCI. Outcomes with different SS-TAVs were directly compared. An internally mounted borescope camera was used to assess procedures. CT of the models was obtained. RESULTS: ACURATE neo2 showed significantly higher rates of successful CA (96.7% vs 75%, P = 0.001) and PCI (98.3% vs 85%, P = 0.008) and was associated with a shorter procedural time compared with Evolut PRO+. Independent predictors of unsuccessful CA and PCI were smaller SAV size and Evolut PRO+. The advantage of ACURATE neo2 was mediated by a larger valve-to-anatomy distance at the top of the leaflet plane (11.3 mm vs 4.8 mm), facilitating more often an external cannulation approach for both CA (36.7% vs 15%, P < 0.001) and PCI (36.7% vs 21.7%, P = 0.013). CONCLUSIONS: The rate of successful CA and PCI following ViV-TAVR was higher with ACURATE neo2 compared with Evolut PRO+. The differences in SS-TAVs design affected the cannulation approach and subsequent procedural outcomes.

17.
EuroIntervention ; 20(12): e770-e780, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38887883

RESUMO

BACKGROUND: Coronary access (CA) is a major concern in redo-transcatheter aortic valve implantation (TAVI) for failing supra-annular self-expanding transcatheter aortic valves (TAVs). AIMS: This ex vivo study evaluated the benefit of leaflet splitting (LS) on subsequent CA after redo-TAVI in anatomies deemed at high risk of unfeasible CA. METHODS: Ex vivo, patient-specific models were printed three-dimensionally. Index TAVI was performed using ACURATE neo2 or Evolut PRO (TAV-1) at the standard implant depth and with different degrees of commissural misalignment (CMA). Redo-TAVI was performed using the balloon-expandable SAPIEN 3 Ultra (TAV-2) at different implant depths with commissural alignment. Selective CA was attempted for each configuration before and after LS in a pulsatile flow simulator. The leaflet splay area was assessed on the bench. RESULTS: In matched comparisons of 128 coronary cannulations across 64 redo-TAVI configurations, the overall feasibility of CA significantly increased after LS (60.9% vs 18.7%; p<0.001). The effect of LS varied according to the sinotubular junction height, TAV-1 design, TAV-1 CMA, and TAV-2 implant depth, given TAV-2 alignment. LS enabled CA for up to CMA 45° with the ACURATE neo2 TAV-1 and up to CMA 30° with the Evolut PRO TAV-1. The combination of LS and a low TAV-2 implant provided the highest feasibility of CA after redo-TAVI. The leaflet splay area ranged from 25.60 mm2 to 37.86 mm2 depending on the TAV-1 platform and TAV-2 implant depth. CONCLUSIONS: In high-risk anatomies, LS significantly improves CA feasibility after redo-TAVI for degenerated supra-annular self-expanding platforms. Decisions on redo-TAVI feasibility should be carefully individualised, taking into account the expected benefit of LS on CA for each scenario.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/instrumentação , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Impressão Tridimensional , Estenose da Valva Aórtica/cirurgia , Vasos Coronários/cirurgia , Falha de Prótese , Reoperação
18.
ESC Heart Fail ; 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-39410743

RESUMO

AIMS: Impella malrotation-inlet orientation away from the left ventricular (LV) apex with normal console waveforms and proper device depth-is commonly observed and possibly associated worse haemodynamics. This study aimed to characterize the haemodynamic consequences of Impella malrotation in cardiogenic shock (CS) patients. METHODS AND RESULTS: We included 100 CS patients (60 ± 12 years; 79.0% males) with available echocardiography during Impella support and pulmonary artery catheter assessment before and during (at 48 h) Impella support. Impella malrotation was identified in 36%. At 48 h, malrotation patients had higher pulmonary artery wedge pressure (PAWP, 16.0 ± 8.2 vs. 13.0 ± 4.6 mmHg; P = 0.033), higher systolic pulmonary artery pressure (PAP, 35.0 ± 11.3 vs. 29.5 ± 9.0 mmHg; P = 0.015), higher diastolic-PAP (19.3 ± 8.1 vs. 15.1 ± 6.1 mmHg; P = 0.007), higher mean-PAP (25.7 ± 9.1 vs. 20.8 ± 6.8 mmHg; P = 0.005), higher right atrial pressure (10.3 ± 4.8 vs. 7.7 ± 4.3 mmHg; P = 0.009), higher pulmonary vascular resistance index (4.78 ± 2.75 vs. 3.49 ± 1.94 WUm2; P = 0.020) and higher pulmonary artery elastance (0.91 ± 0.60 vs. 0.67 ± 0.40 mmHg/mL; P = 0.045). Serum lactate at 48 h was higher in malrotation patients (6.63 ± 6.25 vs. 3.60 ± 4.21 mmol/L; P = 0.004). Malrotation patients presented larger LVEDD during support (52 ± 10 vs. 46 ± 11 mm; P = 0.006), higher rates of aortic regurgitation (AR, 86 vs. 56%; P = 0.004) and higher increase in AR severity (+0.94 ± 0.92 vs. + 0.46 ± 0.95; P = 0.016). No significant differences were found in major adverse outcomes. CONCLUSIONS: In CS patients, Impella malrotation is associated with suboptimal unloading of the LV, worse pulmonary haemodynamics and worse indexes of right ventricular afterload.

19.
JACC Cardiovasc Interv ; 17(11): 1311-1321, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38795093

RESUMO

BACKGROUND: Left atrial appendage occlusion (LAAO) provides mechanical cardioembolic protection for atrial fibrillation (AF) patients who cannot use oral anticoagulation therapy (OAT). Patients with a thrombotic event despite OAT are at high risk for recurrence and may also benefit from LAAO. OBJECTIVES: This study sought to investigate the efficacy of LAAO in AF patients with a thrombotic event on OAT compared to: 1) LAAO in AF patients with a contraindication for OAT; and 2) historical data. METHODS: The international LAAO after stroke despite oral anticoagulation (STR-OAC LAAO) collaboration included patients who underwent LAAO because of thrombotic events on OAT. This cohort underwent propensity score matching and was compared to the EWOLUTION (Evaluating Real-Life Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology) registry, which represents patients who underwent LAAO because of OAT contraindications. The primary outcome was ischemic stroke. Event rates were compared between cohorts and with historical data without OAT, yielding relative risk reductions based on risk scores. RESULTS: Analysis of 438 matched pairs revealed no significant difference in the ischemic stroke rate between the STR-OAC LAAO and EWOLUTION cohorts (2.5% vs 1.9%; HR: 1.37; 95% CI: 0.72-2.61). STR-OAC LAAO patients exhibited a higher thromboembolic risk (HR: 1.71; 95% CI: 1.04-2.83) but lower bleeding risk (HR: 0.39; 95% CI: 0.18-0.88) compared to EWOLUTION patients. The mortality rate was slightly higher in EWOLUTION (4.3% vs 6.9%; log-rank P = 0.028). Relative risk reductions for ischemic stroke were 70% and 78% in STR-OAC LAAO and EWOLUTION, respectively, compared to historical data without OAT. CONCLUSIONS: LAAO in patients with a thrombotic event on OAT demonstrated comparable stroke rates to the OAT contraindicated population in EWOLUTION. The thromboembolic event rate was higher and the bleeding rate lower, reflecting the intrinsically different risk profile of both populations. Until randomized trials are available, LAAO may be considered in patients with an ischemic event on OAT.


Assuntos
Anticoagulantes , Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Contraindicações de Medicamentos , AVC Isquêmico , Sistema de Registros , Humanos , Apêndice Atrial/fisiopatologia , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/complicações , Fibrilação Atrial/mortalidade , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/terapia , Feminino , Masculino , Anticoagulantes/efeitos adversos , Anticoagulantes/administração & dosagem , Idoso , Fatores de Risco , Medição de Risco , Idoso de 80 Anos ou mais , Fatores de Tempo , Administração Oral , AVC Isquêmico/prevenção & controle , AVC Isquêmico/mortalidade , AVC Isquêmico/diagnóstico , AVC Isquêmico/etiologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Falha de Tratamento , Hemorragia/induzido quimicamente , Recidiva , Pessoa de Meia-Idade , Estudos Retrospectivos , Europa (Continente)
20.
JAMA Neurol ; 2024 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-39374446

RESUMO

Importance: Patients with atrial fibrillation (AF) who have ischemic stroke despite taking oral anticoagulation therapy (OAT) have a very high risk of recurrence. Left atrial appendage occlusion (LAAO) is a mechanical stroke prevention strategy that may provide additional protection in patients with thromboembolic events under OAT. Objective: To compare percutaneous LAAO with continuing OAT alone regarding stroke prevention in patients with AF who had a thromboembolic event despite taking OAT. Design, Setting, and Participants: This cohort study was a propensity score-matched comparison of the STR-OAC LAAO cohort, an international collaboration of 21 sites combining patients from multiple prospective registries of patients who underwent LAAO between 2010 and 2022. STR-OAC LAAO cohort patients who had follow-up longer than 3 months were propensity score-matched to a previously published control cohort comprising patients from an established international collaboration of investigator-initiated prospective studies. This control cohort included patients with nonvalvular AF, recent ischemic stroke or transient ischemic attack, and follow-up longer than 3 months who were taking OAT before the index event. Analyses were adjusted for imbalances in gender, age, hypertension, diabetes, and CHA2 DS2-VASc score. Exposure: Left atrial appendage occlusion vs continuation of oral anticoagulation therapy alone (control group). Main Outcomes and Measures: The primary outcome was time to first ischemic stroke. Results: Four hundred thirty-three patients from the STR-OAC LAAO cohort (mean [SD] age, 72 [9] years; 171 [39%] females and 262 [61%] males; mean [SD] CHA2 DS2-VASc score, 5.0 [1.6]) were matched to 433 of 1140 patients (38%) from the control group. During 2-year follow-up, 50 patients experienced ischemic stroke: an annualized event rate of 2.8% per patient-year in the STR-OAC LAAO group vs 8.9% per patient-year in the control group. Left atrial appendage occlusion was associated with a lower risk of ischemic stroke (hazard ratio, 0.33; 95% CI, 0.19-0.58; P < .001) compared with the control group. After LAAO, OAT was discontinued in 290 patients (67%), and the remaining 143 patients (33%) continued OAT after LAAO as an adjunctive therapy. Conclusions and Relevance: In patients with nonvalvular AF and a prior thromboembolic event despite taking OAT, LAAO was associated with a lower risk of ischemic stroke compared with continued OAT alone. Randomized clinical trial data are needed to confirm that LAAO may be a promising treatment option for this population with a very high risk of stroke.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa