Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 45(14): 1269-1277, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38546408

RESUMO

BACKGROUND AND AIMS: Bloodstream infection (BSI) of any cause may lead to device infection in cardiac implantable electronic device (CIED) patients. Aiming for a better understanding of the diagnostic approach, treatment, and outcome, patients with an implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy and defibrillator (CRT-D) hospitalized with BSI were investigated. METHODS: This is a single-centre, retrospective, cohort analysis including consecutive ICD/CRT-D patients implanted between 2012 and 2021. These patients were screened against a list of all hospitalized patients having positive blood cultures consistent with diagnosed infection in any department of a local public hospital. RESULTS: The total cohort consisted of 515 patients. Over a median follow-up of 59 months (interquartile range 31-87 months), there were 47 BSI episodes in 36 patients. The majority of patients with BSI (92%) was admitted to non-cardiology units, and in 25 episodes (53%), no cardiac imaging was performed. Nearly all patients (85%) were treated with short-term antibiotics, whereas chronic antibiotic suppression therapy (n = 4) and system extraction (n = 3) were less frequent. Patients with BSI had a nearly seven-fold higher rate (hazard ratio 6.7, 95% confidence interval 3.9-11.2; P < .001) of all-cause mortality. CONCLUSIONS: Diagnostic workup of defibrillator patients with BSI admitted to a non-cardiology unit is often insufficient to characterize lead-related endocarditis. The high mortality rate in these patients with BSI may relate to underdiagnosis and consequently late/absence of system removal. Efforts to increase an interdisciplinary approach and greater use of cardiac imaging are necessary for timely diagnosis and adequate treatment.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Sepse , Humanos , Estudos Retrospectivos , Desfibriladores Implantáveis/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Antibacterianos/uso terapêutico , Sepse/etiologia , Dispositivos de Terapia de Ressincronização Cardíaca , Resultado do Tratamento
2.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38445836

RESUMO

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Marca-Passo Artificial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial/métodos , Adulto
3.
Eur Heart J ; 44(35): 3327-3335, 2023 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-37387689

RESUMO

AIMS: Management of patients with atrial fibrillation (AF) and concomitant heart failure (HF) remains complex. The Antwerp score, based on four parameters [QRS >120 ms (2 points), known aetiology (2 points), paroxysmal AF (1 point), severe atrial dilation (1 point)] adequately estimated the probability of left ventricular ejection fraction (LVEF) recovery after AF ablation in a single-centre cohort. The present study aims to externally validate this prediction model in a large European multi-centre cohort. METHODS AND RESULTS: A total of 605 patients (61.1 ± 9.4 years, 23.8% females, 79.8% with persistent AF) with HF and impaired LVEF (<50%) undergoing AF ablation in 8 European centres were retrospectively identified. According to the LVEF changes at 12-month echocardiography, 427 (70%) patients fulfilled the '2021 Universal Definition of HF' criteria for LVEF recovery and were defined as 'responders'. External validation of the score yielded good discrimination and calibration {area under the curve 0.86 [95% confidence interval (CI) 0.82-0.89], P < .001; Hosmer-Lemeshow P = .29}. Patients with a score < 2 had a 93% probability of LVEF recovery as opposed to only 24% in patients with a score > 3. Responders experienced more often positive ventricular remodelling [odds ratio (OR) 8.91, 95% CI 4.45-17.84, P < .001], fewer HF hospitalizations (OR 0.09, 95% CI 0.05-0.18, P < .001) and lower mortality (OR 0.11, 95% CI 0.04-0.31, P < .001). CONCLUSION: In this multi-centre study, a simple four-parameter score predicted LVEF recovery after AF ablation in patients with HF and discriminated clinical outcomes. These findings support the use of the Antwerp score to standardize shared decision-making regarding AF ablation referral in future clinical studies.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Feminino , Humanos , Masculino , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Volume Sistólico , Função Ventricular Esquerda , Estudos Retrospectivos , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 34(5): 1216-1227, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37087672

RESUMO

INTRODUCTION: The assessment of the ventricular myocardial substrate critically depends on the size of mapping electrodes, their orientation with respect to wavefront propagation, and interelectrode distance. We conducted a dual-center study to evaluate the impact of microelectrode mapping in patients undergoing catheter ablation (CA) of ventricular tachycardia (VT). METHODS: We included 21 consecutive patients (median age, 68 [12], 95% male) with structural heart disease undergoing CA for electrical storm (n = 14) or recurrent VT (n = 7) using the QDOT Micro catheter and a multipolar catheter (PentaRay, n = 9). The associations of peak-to-peak maximum standard bipolar (BVc ) and minibipolar (PentaRay, BVp ) with microbipolar (BVµMax ) voltages were respectively tested in sinus rhythm with mixed effect models. Furthermore, we compared the features of standard bipolar (BE) and microbipolar (µBE) electrograms in sinus rhythm at sites of termination with radiofrequency energy. RESULTS: BVµMax was moderately associated with both BVc (ß = .85, p < .01) and BVp (ß = .56, p < .01). BVµMax was 0.98 (95% CI: 0.93-1.04, p < .01) mV larger than corresponding BVc , and 0.27 (95% CI: 0.16-0.37, p < .01) mV larger than matching BVp in sinus rhythm, with higher percentage differences in low voltage regions, leading to smaller endocardial dense scar (2.3 [2.7] vs. 12.1 [17] cm2 , p < .01) and border zone (3.2 [7.4] vs. 4.8 [20.1] cm2 , p = .03) regions in microbipolar maps compared to standard bipolar maps. Late potentials areas were nonsignificantly greater in microelectrode maps, compared to standard electrode maps. At sites of VT termination (n = 14), µBE were of higher amplitude (0.9 [0.8] vs. 0.4 [0.2] mV, p < .01), longer duration (117 [66] vs. 74 [38] ms, p < .01), and with greater number of peaks (4 [2] vs. 2 [1], p < .01) in sinus rhythm compared to BE. CONCLUSION: microelectrode mapping is more sensitive than standard bipolar mapping in the identification of viable myocytes in SR, and may facilitate recognition of targets for CA.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Masculino , Idoso , Feminino , Microeletrodos , Resultado do Tratamento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/complicações , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cicatriz
5.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37944131

RESUMO

AIMS: Brugada syndrome (BrS) is an inherited disease associated with an increased risk of ventricular arrhythmias. Recent studies have reported the presence of an altered atrial phenotype characterized by abnormal P-wave parameters. The aim of this study was to identify BrS based exclusively on P-wave features through an artificial intelligence (AI)-based model. METHODS AND RESULTS: Continuous 5 min 12-lead ECG recordings were obtained in sinus rhythm from (i) patients with spontaneous or ajmaline-induced BrS and no history of AF and (ii) subjects with suspected BrS and negative ajmaline challenge. The recorded ECG signals were processed and divided into epochs of 15 s each. Within these epochs, P-waves were first identified and then averaged. From the averaged P-waves, a total of 67 different features considered relevant to the classification task were extracted. These features were then used to train nine different AI-based supervised classifiers. A total of 2228 averaged P-wave observations, resulting from the analysis of 33 420 P-waves, were obtained from 123 patients (79 BrS+ and 44 BrS-). Averaged P-waves were divided using a patient-wise split, allocating 80% for training and 20% for testing, ensuring data integrity and reducing biases in AI-based model training. The BrS+ patients presented with longer P-wave duration (136 ms vs. 124 ms, P < 0.001) and higher terminal force in lead V1 (2.5 au vs. 1.7 au, P < 0.01) compared with BrS- subjects. Among classifiers, AdaBoost model had the highest values of performance for all the considered metrics, reaching an accuracy of over 81% (sensitivity 86%, specificity 73%). CONCLUSION: An AI machine-learning model is able to identify patients with BrS based only on P-wave characteristics. These findings confirm the presence of an atrial hallmark and open new horizons for AI-guided BrS diagnosis.


Assuntos
Fibrilação Atrial , Síndrome de Brugada , Humanos , Fibrilação Atrial/induzido quimicamente , Inteligência Artificial , Ajmalina/efeitos adversos , Eletrocardiografia/métodos
6.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37787610

RESUMO

AIMS: Little is known about dynamic changes of the left atrial (LA) substrate over time in patients with atrial fibrillation (AF). This study aims to evaluate substrate changes following pulmonary vein isolation (PVI). METHODS AND RESULTS: In our prospective observational study, consecutive patients undergoing first PVI-only and redo ablation were included. High-density maps of the two procedures were compared. Progression or regression was diagnosed if a significant concordant decrease or increase in bipolar voltages in ≥2 segments was observed, respectively. In 28 patients (61.2 ± 9.5 years, 39% female, 53.5% persistent AF), 111.013 voltage points from 56 high-density LA maps (1.982 points/patient) were analysed. Comparing the high-density maps of the first and second procedures, in the progression group (17 patients, 61%), there was a decrease in global (-35%, P < 0.001) and all regional voltages. In the regression group (11 patients, 39%), there was an increase in global (+43%, P < 0.001) and regional voltages. Comparing the progression with the regression group, the area of low-voltage zone (LVZ) increased (+3.5 vs. -4.5 cm2, P < 0.001) and LA activation time prolonged (+8.0 vs. -9.1 ms, P = 0.005). Baseline clinical parameters did not predict progression or regression. In patients with substrate progression, pulmonary veins (PVs) were more frequently isolated (P = 0.02) and the AF pattern at recurrence was more frequently persistent (P = 0.005). CONCLUSION: Our study describes bidirectional dynamic properties of the LA substrate with concordant either progressive or regressive changes. Regression occurs with reduced AF burden after the first procedure, while progression is associated with persistent AF recurrence despite durable PV isolation. The dynamic nature of LA substrate poses questions about LVZ-based ablation strategies.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Apêndice Atrial/cirurgia , Recidiva , Resultado do Tratamento
7.
Circulation ; 142(13): 1249-1260, 2020 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-32791857

RESUMO

BACKGROUND: Electroanatomic voltage mapping (EVM) is a promising modality for guiding endomyocardial biopsies (EMBs). However, few data support its feasibility and safety. We now report the largest cohort of patients undergoing EVM-guided EMBs to show its diagnostic yield and to compare it with a cardiac magnetic resonance (CMR)-guided approach. METHODS: We included 162 consecutive patients undergoing EMB at our institution from 2010 to 2019. EMB was performed in pathological areas identified at EVM and CMR. CMR and EVM sensitivity and specificity regarding the identification of pathological substrates of myocardium were evaluated according to EMB results. RESULTS: Preoperative CMR showed late gadolinium enhancement in 70% of the patients, whereas EVM identified areas of low voltage in 61%. Right (73%), left (19%), or both ventricles (8%) underwent sampling. EVM proved to have sensitivity similar to CMR (74% versus 77%), with specificity being 70% and 47%, respectively. In 12 patients with EMB-proven cardiomyopathy, EVM identified pathological areas that had been undetected at CMR evaluation. Sensitivity of pooled EVM and CMR was as high as 95%. EMB analysis allowed us to reach a new diagnosis, different from the suspected clinical diagnosis, in 39% of patients. The complications rate was low, mostly related to vascular access, with no patients requiring urgent management. CONCLUSIONS: EVM proved to be a promising tool for targeted EMB because of its sensitivity and specificity for identification of myocardial pathological substrates. EVM was demonstrated to have accuracy similar to CMR. EVM and CMR together conferred a positive predictive value of 89% on EMB.


Assuntos
Meios de Contraste/administração & dosagem , Técnicas Eletrofisiológicas Cardíacas , Gadolínio/administração & dosagem , Ventrículos do Coração , Imageamento por Ressonância Magnética , Miocárdio , Adulto , Biópsia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade
8.
Medicina (Kaunas) ; 57(3)2021 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-33802881

RESUMO

Myocardial inflammation is an important cause of cardiovascular morbidity and sudden cardiac death in athletes. The relationship between sports practice and myocardial inflammation is complex, and recent data from studies concerning cardiac magnetic resonance imaging and endomyocardial biopsy have substantially added to our understanding of the challenges encountered in the comprehensive care of athletes with myocarditis or inflammatory cardiomyopathy (ICM). In this review, we provide an overview of the current knowledge on the epidemiology, pathophysiology, diagnosis, and treatment of myocarditis, ICM, and myopericarditis/perimyocarditis in athletes, with a special emphasis on arrhythmias, patient-tailored therapies, and sports eligibility issues.


Assuntos
Miocardite , Esportes , Atletas , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Humanos , Inflamação , Miocardite/diagnóstico
9.
Medicina (Kaunas) ; 57(4)2021 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-33805943

RESUMO

The prediction and prevention of sudden cardiac death is the philosopher's stone of clinical cardiac electrophysiology. Sports can act as triggers of fatal arrhythmias and therefore it is essential to promptly frame the athlete at risk and to carefully evaluate the suitability for both competitive and recreational sports activity. A history of syncope or palpitations, the presence of premature ventricular complexes or more complex arrhythmias, a reduced left ventricular systolic function, or the presence of known or familiar heart disease should prompt a thorough evaluation with second level examinations. In this regard, cardiac magnetic resonance and electrophysiological study play important roles in the diagnostic work-up. The role of genetics is increasing both in cardiomyopathies and in channelopathies, and a careful evaluation must be focused on genotype positive/phenotype negative subjects. In addition to being a trigger for fatal arrhythmias in certain cardiomyopathies, sports also play a role in the progression of the disease itself, especially in the case arrhythmogenic right ventricular cardiomyopathy. In this paper, we review the latest European guidelines on sport cardiology in patients with cardiovascular diseases, focusing on arrhythmic risk stratification and the management of cardiomyopathies and channelopathies.


Assuntos
Cardiologia , Cardiomiopatias , Doenças Cardiovasculares , Canalopatias , Esportes , Cardiomiopatias/complicações , Canalopatias/complicações , Canalopatias/genética , Humanos
10.
Ann Vasc Surg ; 44: 67-76, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28479470

RESUMO

PURPOSE: Our purpose is to analyze the outcomes of endovascular aneurysm repair (EVAR) in patients treated with Excluder endograft (W.L. Gore and Associate, Flagstaff, AZ), comparing second generation, featuring SIM-PULL delivery system (ExSP) and third generation, featuring C3 (ExC3), concerning intraprocedural data and long-term outcomes. METHODS: In our single-center, comparative study, we retrospectively analyzed all patients undergoing elective EVAR with Excluder from May 2008 to December 2015. This cohort was firstly divided according to the design of the endograft used, and then, two subgroups of complex procedures were identified according to International Standards. Preliminary end points were early- and mid-term outcomes. Primary end point was procedural data (i.e., procedural and fluoroscopy time, radiation dose (DAP), and contrast medium amount). RESULTS: The study included 64 patients (24 ExSP and 40 ExC3) with a mean follow-up of 31.6 ± 22.9 months. Patients in ExC3 group had significantly more risk factors (past or present history of smoking, P = 0.019), comorbidities (chronic heart failure and chronic kidney disease, both P = 0.032), as well as a more unfavorable anatomy (neck angulation, P = 0.035). Concerning preliminary outcome, no significant between-group difference was noted. As for intraoperative data, procedure duration was significantly shorter: 120 vs. 151 min (P = 0.002) in the overall population and 129 vs. 173 min (P = 0.004) in complex cases. A significant reduction was also found in fluoroscopy time and radiation exposure: 24,084 vs. 32,548 cGy/cm2 (P = 0.020) in the overall population and 26,770 vs. 41,104 cGy/cm2 (P = 0.003) in complex cases. No significant difference was found for contrast volume. CONCLUSIONS: The study shows that new C3 excluder enables to reduce radiation exposure and procedural time compared to the previous device. C3 excluder results are comparable to those of the previous device in spite of more comorbidities and complex anatomy of the treated patients. Further studies are needed to assess device performance on longer-term follow-up.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Comorbidade , Meios de Contraste/administração & dosagem , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Desenho de Prótese , Doses de Radiação , Exposição à Radiação , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
13.
Clin Res Cardiol ; 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38922425

RESUMO

BACKGROUND: Although atrial fibrosis has a relevant impact on ablation success rate, experimental studies have reported that extensive fibrosis may be accompanied by a reduced burden secondary to a prominent depression of atrial excitability. OBJECTIVES: We aimed to identify clinical and echocardiographic factors associated with extensive left atrial myopathy (ELAM), to analyze the predictive ability of established scores (AF score, APPLE, and DR-FLASH) and assess outcomes in terms of AF recurrence, left atrial flutter, and post-procedural heart failure admissions. METHODS: A total of 950 consecutive patients undergoing the first AF ablation were included. A 3D electroanatomical mapping system (CARTO3, Biosense Webster) was created using a multipolar mapping catheter (PentaRay, Biosense Webster). ELAM was defined as ≥ 50% low voltage area. A subanalysis with four groups was also created (< 10%; 10-20%; 10-20%; and > 30%). Logistic regressions, Cox proportional hazards models, and log-rank test were used to test the predictors independently associated with the presence of ELAM and AF recurrence. The model was prospectively validated in a cohort of 150 patients obtaining an excellent ability for prediction AUC 0.90 (CI 95% 0.84-0.96). RESULTS: Overall, 78 (8.42%) presented ELAM. Age, female sex, persistent AF, first-degree AV block, and E/e' were significant predictors. The model incorporating these factors outperformed the existing scores (AUC = 0.87). During a mean follow-up of 20 months (IQR 9 to 36), patients with ELAM presented a higher rate of AF recurrence (42.02% vs 26.01%, p = 0.030), left atrial flutter (26.03% vs 8.02%, p < 0.001), and post-procedural heart failure admissions (12.01% vs 0.61%, p < 0.001) than non-ELAM patients. CONCLUSIONS: This study reveals the incidence and clinical factors associated with ELAM in AF, highlighting age, female, persistent AF, first-degree AV block, and E/e'. Importantly, the presence of ELAM is associated with poorer outcomes in terms of recurrence and HF admission.

14.
Heart Rhythm ; 20(5): 658-665, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36640853

RESUMO

BACKGROUND: The benefit of an anterior mitral line (AML) in patients with persistent atrial fibrillation (AF) and anterior atrial scar undergoing ablation has never been investigated. OBJECTIVE: The purpose of this study was to evaluate the outcomes of AML in addition to standard treatment compared to standard treatment alone (no AML) in this subset of patients. METHODS: Patients with persistent AF and anterior low-voltage zone (LVZ) treated with AML in 3 centers were retrospectively enrolled. The patients were matched in 1:1 fashion with patients having persistent AF and anterior LVZ who underwent conventional ablation in the same centers. Matching parameters were age, LVZ burden, and repeated ablation. Primary endpoint was AF/atrial tachycardia (AT) recurrence. RESULTS: One hundred eight-six patients (age 66 ± 9 years; 34% women) were selected and divided into 2 matched groups. Bidirectional conduction block was achieved in 95% of AML. After median follow-up of 2 years, AF/AT recurrence occurred in 29% of the patients in the AML group vs 48% in the no AML group (log-rank P = .024). On Cox regression multivariate analysis, left atrial volume (hazard ratio [HR] 1.03; P = .006) and AML (HR 0.46; P = .003) were significantly associated with the primary endpoint. On univariate logistic regression, lower body mass index, older age, extensive anterior LVZ, and position of the left atrial activation breakthrough away from the AML were associated with first-pass AML block. CONCLUSION: In this retrospective matched analysis of patients with persistent AF and anterior scar, AML in addition to standard treatment was associated with improved AF/AT-free survival compared to standard treatment alone.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Cicatriz/diagnóstico , Cicatriz/etiologia , Resultado do Tratamento , Técnicas Eletrofisiológicas Cardíacas , Taquicardia , Recidiva , Veias Pulmonares/cirurgia
15.
JACC Clin Electrophysiol ; 9(5): 620-627, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37225308

RESUMO

BACKGROUND: Left bundle branch area (LBBA) pacing is a promising pacing technique. LBBA implantable cardioverter-defibrillator (ICD) lead implantation reduces the number of leads in patients with both pacing and ICD indications, reducing cost and potentially increasing safety. LBBA positioning of ICD leads has not previously been described. OBJECTIVES: The goal of this study was to evaluate the safety and feasibility of implanting an LBBA ICD lead. METHODS: This prospective, single-center, feasibility study was conducted in patients with an ICD indication. LBBA ICD lead implantation was attempted. Acute pacing parameters and paced electrocardiography data were collected, and defibrillation testing was performed. RESULTS: LBBA defibrillator (LBBAD) implantation was attempted in 5 patients (mean age 57 ± 16.5 years; 20% female) and achieved in 3 (60%). Mean procedural and fluoroscopy duration were 170.0 ± 17.3 minutes and 28.8 ± 16.1 minutes, respectively. Left bundle capture was achieved in 2 patients (66%) and left septal capture in 1 patient. LBBA pacing exhibited a mean QRS duration and V6 R-wave peak time of 121.3 ± 8.3 milliseconds and 86.1 ± 10.0 milliseconds. In all 3 patients, defibrillation testing was successful with mean time to adequate shock delivery of 8.6 ± 2.6 seconds. Acute LBBA pacing threshold and R-wave amplitudes were 0.80 ± 0.60 V at 0.4 milliseconds and 7.0 ± 2.7 mV. No LBBA lead-related complications occurred. CONCLUSIONS: This first-in-human evaluation showed the feasibility of LBBAD implantation in a small cohort of patients. With current tools, implantation remains complex and time-consuming. Considering the feasibility reported and the potential benefits, further technological development in this field is warranted with evaluation of long-term safety and performance.


Assuntos
Desfibriladores Implantáveis , Septo Interventricular , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Masculino , Estudos de Viabilidade , Estudos Prospectivos , Eletrocardiografia
16.
Artigo em Inglês | MEDLINE | ID: mdl-37783852

RESUMO

BACKGROUND: A novel method to measure atrial fibrillation cycle length (AF-CL) was recently described, based on the average of 10 consecutive signals (FARS10). FARS10 accurately identified pulmonary vein isolation (PVI)-responders among patients with persistent AF. Whether this method is applicable to patients with paroxysmal AF is unknown. OBJECTIVE: The aim of this study is to evaluate the prognostic value of FARS10 measurements in patients with paroxysmal AF. METHODS AND RESULTS: We enrolled paroxysmal AF patients undergoing PVI in a prospective multicenter study. After AF induction with a standardized protocol, the AF-CL was measured using FARS-10 method. The primary endpoint was AF/AT-recurrence. One-hundred and four patients were included (61 ± 14 years, 25% females). After a mean follow-up of 12 ± 4 months, AF/AT recurrence rate was 20%. The fastest PV CL (fPV-CL) was independently associated with the primary endpoint at multivariate analysis (HR 1.02, p < 0.001). Every 10 ms increase in fPV-CL, AF recurrences increased by 20%. The value of 160 ms was found to be the optimal cut-off (specificity 81%, sensitivity 76%). Patients with fPV-CL < 160 ms experienced lower AF recurrences as compared to patients with fPV-CL > 160 ms (8% vs. 32% at 1 year; HR = 0.17, p < 0.001). Progression to persistent AF was observed in 13% of patients with fPV-CL > 160 ms. CONCLUSION: fPV-CL measured with the FARS-10 method accurately predicts PVI success in paroxysmal AF patients undergoing PVI. Patients with slow PV activity (fPV-CL > 160 ms) experience higher AF recurrence rate after PVI and more frequent progression to persistent AF. In 104 patients with paroxysmal atrial fibrillation (AF) undergoing AF ablation, AF was induced at the beginning of the procedure. Pulmonary vein activity was measured using FARS10 measurement (10 consecutive fastest atrial repetitive similar morphology signals). The value of 160 ms was found to be the best cut-off to discriminate outcomes. At 1-year follow-up, patients with fast veins (< 160 ms) experienced significantly fewer AF recurrences as compared to patients with slow veins (> 160 ms). PV activity measured with FARS10 method accurately discriminates pulmonary vein isolation responders, in patients with paroxysmal AF. ABBREVIATIONS: AF atrial fibrillation, AT atrial tachycardia, CL cycle length, FARS10: 10 consecutive fastest atrial repetitive similar morphology signal, fPV fastest pulmonary vein, HR hazard ratio, ms milliseconds.

17.
Front Cardiovasc Med ; 10: 1112561, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36873407

RESUMO

Background: There is no clear guidance on how to implement opportunistic atrial fibrillation (AF) screening in daily clinical practice. Objectives: This study evaluated the perception of general practitioners (GPs) about value and practicalities of implementing screening for AF, focusing on opportunistic single-time point screening with a single-lead electrocardiogram (ECG) device. Methods: A descriptive cross-sectional study was conducted with a survey developed to assess overall perception concerning AF screening, feasibility of opportunistic single-lead ECG screening and implementation requirements and barriers. Results: A total of 659 responses were collected (36.1% Eastern, 33.4% Western, 12.1% Southern, 10.0% Northern Europe, 8.3% United Kingdom & Ireland). The perceived need for standardized AF screening was rated as 82.7 on a scale from 0 to 100. The vast majority (88.0%) indicated no AF screening program is established in their region. Three out of four GPs (72.1%, lowest in Eastern and Southern Europe) were equipped with a 12-lead ECG, while a single-lead ECG was less common (10.8%, highest in United Kingdom & Ireland). Three in five GPs (59.3%) feel confident ruling out AF on a single-lead ECG strip. Assistance through more education (28.7%) and a tele-healthcare service offering advice on ambiguous tracings (25.2%) would be helpful. Preferred strategies to overcome barriers like insufficient (qualified) staff, included integrating AF screening with other healthcare programs (24.9%) and algorithms to identify patients most suitable for AF screening (24.3%). Conclusion: GPs perceive a strong need for a standardized AF screening approach. Additional resources may be required to have it widely adopted into clinical practice.

18.
Heart Rhythm ; 20(10): 1370-1377, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37414109

RESUMO

BACKGROUND: Omnipolar technology (OT) was recently proposed to generate electroanatomic voltage maps with orientation-independent electrograms. We describe the first cohort of patients undergoing ventricular tachycardia (VT) ablation guided by OT. OBJECTIVE: The purpose of this study was to compare omnipolar and bipolar high-density maps with regard to voltage amplitude, late potential (LP) annotation, and isochronal late activation mapping distribution. METHODS: A total of 24 patients (16 [66%] ischemic cardiomyopathy and 12 [50%] redo cases) underwent VT ablation under OT guidance. Twenty-seven sinus rhythm substrate maps and 10 VT activation maps were analyzed. Omnipolar and bipolar (HD Wave Solution algorithm, Abbott, Abbott Park, IL) voltages were compared. Areas of LPs were correlated with the VT isthmus areas, and late electrogram misannotation was evaluated. Deceleration zones based on isochronal late activation maps were analyzed by 2 blinded operators and compared to the VT isthmuses. RESULTS: OT maps had higher point density (13.8 points/cm2 vs 8.0 points/cm2). Omnipolar points had 7.1% higher voltages than bipolar points within areas of dense scar and border zone. The number of misannotated points was significantly lower for OT maps (6.8% vs 21.9%; P = .01), showing comparable sensitivity (53% vs 59%) but higher specificity (79% vs 63%). The sensitivity and specificity of detection of the VT isthmus in the deceleration zones were, respectively, 75% and 65% for OT and 35% and 55% for bipolar mapping. At 8.4 months, 71% freedom from VT recurrence was achieved. CONCLUSION: OT is a valuable tool for guiding VT ablation, providing more accurate identification of LPs and isochronal crowding due to slightly higher voltages.

19.
Am J Cardiol ; 203: 451-458, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37540903

RESUMO

Gender-related differences have been reported in patients who underwent pulmonary vein isolation (PVI). Atrial substrate plays a role in the outcomes after ablation but gender-related differences in atrial substrate have never been described in detail. We sought to analyze gender-related differences in atrial remodeling (spontaneous low-voltage zones [LVZs]) and their clinical relevance after PVI. We conducted a prospective multicenter study, including consecutive patients who underwent first PVI-only atrial fibrillation (AF) ablation. LVZs were analyzed on high-density electroanatomical maps collected with multipolar catheter, before PVI. In total, 262 patients (61 ± 11 years, 31% female, 50% persistent AF) were followed for 28 months. In women, LVZs were larger (10% vs 4% of left atrial surface [p <0.001]) and female gender was independently associated with fourfold higher risk of having advanced (LVZ > 15%) atrial remodeling (odds ratio 4.56, p <0.001). AF recurrence-free survival was not different between men and women (log-rank p = 0.2). Although LVZs were independently associated higher AF recurrences at multivariate analysis (hazard ratio [HR] 1.2, p = 0.038), female gender was not (HR 1.4, p = 0.211). Specifically, the LVZ cutoff to predict outcomes was different in men and women: >5% in men (HR 3.0, p <0.001), >15% in women (HR 2.7, p = 0.02). In conclusion, women have more widespread LVZ in all left atrial regions. Despite more extensive atrial remodeling, the AF recurrence rate is similar in men and women, and LVZs become prognostic in women only at high burden (>15%). LVZs seem to have a different prognostic role in men and women.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Feminino , Estudos Prospectivos , Resultado do Tratamento , Átrios do Coração , Veias Pulmonares/cirurgia
20.
J Am Heart Assoc ; 12(1): e027795, 2023 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-36565183

RESUMO

Background Left atrial substrate may have mechanistic relevance for ablation of atrial fibrillation (AF). We sought to analyze the relationship between low-voltage zones (LVZs), transition zones, and AF recurrence in patients undergoing pulmonary vein isolation. Methods and Results We conducted a prospective multicenter study on consecutive patients undergoing pulmonary vein isolation-only approach. LVZs and transition zones (0.5-1 mV) were analyzed offline on high-density electroanatomical maps collected before pulmonary vein isolation. Overall, 262 patients (61±11 years, 31% female) with paroxysmal (130 pts) or persistent (132 pts) AF were included. After 28 months of follow-up, 73 (28%) patients experienced recurrence. An extension of more than 5% LVZ in paroxysmal AF and more than 15% in persistent AF was associated with recurrence (hazard ratio [HR], 4.4 [95% CI, 2.0-9.8], P<0.001 and HR, 1.9 [95% CI, 1.1-3.7], P=0.04, respectively). Significant association was found between LVZs and transition zones and between LVZs and left atrial volume index (LAVI) (both P<0.001). Thirty percent of patients had significantly increased LAVI without LVZs. Eight percent of patients had LVZs despite normal LAVI. Older age, female sex, oncological history, and increased AF recurrence characterized the latter subgroup. Conclusions In patients undergoing first pulmonary vein isolation, the impact of LVZs on outcomes occurs with lower burden in paroxysmal than persistent AF, suggesting that not all LVZs have equal prognostic implications. A proportional area of moderately decreased voltages accompanies LVZs, suggesting a continuous substrate instead of the dichotomous division of healthy or diseased tissue. LAVI generally correlates with LVZs, but a small subgroup of patients may present with disproportionate atrial remodeling, despite normal LAVI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Ablação por Cateter/métodos , Recidiva
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa