Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Eur Respir J ; 56(3)2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32430416

RESUMO

BACKGROUND: Telemonitoring trials for early detection of acute exacerbations of chronic obstructive pulmonary disease (AECOPD) have provided mixed results. Day-to-day variations in lung function measured by the forced oscillation technique (FOT) may yield greater insight. We evaluated the clinical utility of home telemonitoring of variability in FOT measures in terms of 1) the relationship with symptoms and quality of life (QoL); and 2) the timing of variability of FOT measures and symptom changes prior to AECOPD. METHODS: Daily FOT parameters at 5 Hz (resistance (R) and reactance (X); Resmon Pro Diary, Restech Srl, Milan, Italy), daily symptoms (COPD Assessment Test (CAT)) and 4-weekly QoL data (St George's Respiratory Questionnaire (SGRQ)) were recorded over 8-9 months from chronic obstructive pulmonary disease (COPD) patients. Variability of R and X was calculated as the standard deviation (sd) over 7-day running windows and we also examined the effect of varying window size. The relationship of FOT versus CAT and SGRQ was assessed using linear mixed modelling, daily changes in FOT variability and CAT prior to AECOPD using one-way repeated measures ANOVA. RESULTS: Fifteen participants with a mean±sd age of 69±10 years and a % predicted forced expiratory volume in 1 s (FEV1) of 39±10% had a median (interquartile range (IQR)) adherence of 95.4% (79.0-98.8%). Variability of the inspiratory component of X (indicated by the standard deviation of inspiratory reactance (SDXinsp)) related to CAT and weakly to SGRQ (fixed effect estimates 1.57, 95% CI 0.65-2.49 (p=0.001) and 4.41, 95% CI -0.06 to 8.89 (p=0.05), respectively). SDXinsp changed significantly on the same day as CAT (1 day before AECOPD, both p=0.02) and earlier when using shorter running windows (3 days before AECOPD, p=0.01; accuracy=0.72 for 5-day windows). CONCLUSIONS: SDXinsp from FOT telemonitoring reflects COPD symptoms and may be a sensitive biomarker for early detection of AECOPD.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Qualidade de Vida , Volume Expiratório Forçado , Humanos , Itália , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Testes de Função Respiratória
2.
Respirology ; 25(8): 827-835, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32026586

RESUMO

BACKGROUND AND OBJECTIVE: Abnormal peripheral airway function is an important feature of asthma and relates to asthma symptoms and poor asthma control. We aimed to determine whether peripheral airway function, as measured by forced oscillatory impedance and multiple-breath nitrogen washout (MBNW), relates to symptom improvement in asthmatic participants with uncontrolled asthma, after stepping up to high-dose ICS/LABA treatment. METHODS: A total of 19 subjects (14 females, mean age: 29.9 ± 13.6 years) with uncontrolled asthma, as defined by an ACQ5 > 1.5, taking 500 µg/day fluticasone equivalent or less, underwent spirometry, plethysmography, fractional exhaled FeNO, forced oscillatory resistance (Rrs5Hz ) and reactance (Xrs5Hz ), and indices of MBNW ventilation heterogeneity (lung clearance index (LCI), diffusion-convection-dependent (Sacin) and convection-dependent (Scond)). Measurements were made before and after 8 weeks of treatment with fluticasone/formoterol combination inhaler 250/10 µg, 2 puffs twice daily. RESULTS: Treatment improved ACQ5 (P = 0.0002), FEV1 (P = 0.02), FVC (P = 0.04), FeNO (P = 0.0008), Xrs5Hz (P = 0.01), LCI (P = 0.0002), Sacin (P = 0.006) and Scond (P = 0.01). At baseline, ACQ5 correlated with Xrs5Hz (rs = 0.52, P = 0.03) and Rrs5Hz (rs = 0.55, P = 0.02). The improvement in ACQ5 was predicted by more abnormal baseline LCI (P = 0.03), Scond (P = 0.02) and Rrs5Hz (P = 0.006). Baseline Scond was the best predictor of a clinically meaningful improvement in asthma control (ΔACQ > 0.5, ROC-AUC = 0.91, P = 0.007). CONCLUSION: Step-up to high-dose combination treatment in uncontrolled asthma is associated with improved peripheral airway function as measured by Xrs5Hz and MBNW. Baseline MBNW and FOT parameters correlated with the improvement in symptoms and may predict a positive response to up-titration in uncontrolled asthmatic patients.


Assuntos
Asma/tratamento farmacológico , Asma/prevenção & controle , Oscilometria , Ventilação Pulmonar , Administração por Inalação , Corticosteroides/administração & dosagem , Corticosteroides/uso terapêutico , Agonistas de Receptores Adrenérgicos beta 2/uso terapêutico , Adulto , Asma/fisiopatologia , Combinação de Medicamentos , Feminino , Fluticasona/administração & dosagem , Fluticasona/farmacologia , Fluticasona/uso terapêutico , Fumarato de Formoterol/administração & dosagem , Fumarato de Formoterol/farmacologia , Fumarato de Formoterol/uso terapêutico , Humanos , Pulmão/efeitos dos fármacos , Pulmão/fisiopatologia , Masculino , Nitrogênio/metabolismo , Ventilação Pulmonar/efeitos dos fármacos , Curva ROC , Respiração , Testes de Função Respiratória , Espirometria
3.
Respirology ; 23(5): 512-518, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29141272

RESUMO

BACKGROUND AND OBJECTIVE: Smokers develop respiratory symptoms and peripheral airway dysfunction even when spirometry is preserved. Multiple breath nitrogen washout (MBNW) and impulse oscillometry system (IOS) are potentially useful measures of peripheral airway function but they have not been compared in such subjects. We hypothesized that MBNW and IOS are jointly abnormal in smokers with normal spirometry and that these abnormalities relate to respiratory symptoms. METHODS: Eighty smokers with normal spirometry completed a symptom questionnaire, had ventilation heterogeneity in diffusion (Sacin) and convection-dependent (Scond) airways and trapped gas volume at functional residual capacity as a percentage of vital capacity (%VtrFRC/VC) measured by MBNW. Respiratory resistance and reactance at 5 and 20 Hz were measured using IOS. RESULTS: Respiratory symptoms were reported in 55 (68%) subjects. Forty (50%) subjects had at least one abnormal MBNW parameter, predominantly in Sacin. Forty-one (51%) subjects had at least one abnormal IOS parameter, predominantly in resistance. Sixty-one (76%) subjects had an abnormality in either MBNW or IOS. Chronic bronchitis symptoms were associated with an increased Scond, while wheeze was associated with lower spirometry and an increased resistance. Abnormalities in MBNW and IOS parameters were unrelated to each other. CONCLUSIONS: Respiratory symptoms and peripheral airway dysfunction are common in smokers with normal spirometry. Symptoms of chronic bronchitis related to conductive airway abnormalities, while wheeze was related to spirometry and IOS. The clinical significance of abnormalities in peripheral airway function in smokers remains undetermined.


Assuntos
Bronquite Crônica/fisiopatologia , Pulmão/fisiopatologia , Fumar/fisiopatologia , Adulto , Resistência das Vias Respiratórias , Feminino , Capacidade Residual Funcional , Humanos , Masculino , Oscilometria , Estudos Prospectivos , Capacidade de Difusão Pulmonar , Sons Respiratórios , Espirometria , Inquéritos e Questionários , Avaliação de Sintomas , Volume de Ventilação Pulmonar
4.
J Clin Monit Comput ; 32(3): 509-512, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28761996

RESUMO

The forced oscillation technique (FOT) is an emerging clinical lung function test, with commercial devices becoming increasingly available. However comparability across existing devices has not been established. We evaluated in vivo and in vitro measurements made using three commercial devices against a custom-built device (WIMR): Resmon Pro Diary (Restech srl, Italy), tremoFlo C-100 (Thorasys Medical Systems, Canada), Jaeger Masterscope CT IOS (CareFusion, Hoechberg, Germany). Respiratory system resistance Rrs and reactance Xrs at 5 Hz were examined in twelve healthy subjects (mean age 33 ± 11 years, 7 males), and in two test standards of known resistance and reactance. Subjects performed three measurements during tidal breathing on the four devices in random order. Total, inspiratory and expiratory Rrs and Xrs were calculated and compared using one-way repeated measures ANOVA and Bonferroni post-hoc tests. Rrs did not differ between devices, with <10% deviation from predicted, except for the IOS device. With Xrs, similar values were seen between the WIMR and Resmon devices and between the tremoFlo and IOS devices. No differences were observed using test standards; deviation from theoretical value was <2% for resistance and <5% for reactance. The WIMR, tremoFlo and Resmon Pro but not IOS devices measure similar Rrs, whereas there was more disparity across devices in the estimation of Xrs parameters. The discrepancy between in vivo and in vitro measurements suggest that FOT validation procedures need to take into account the breathing pattern, either using biological controls or a breathing model.


Assuntos
Desenho de Equipamento , Oscilometria/métodos , Testes de Função Respiratória/instrumentação , Testes de Função Respiratória/métodos , Adulto , Feminino , Voluntários Saudáveis , Humanos , Técnicas In Vitro , Masculino , Monitorização Fisiológica , Reprodutibilidade dos Testes , Respiração , Processamento de Sinais Assistido por Computador , Software , Adulto Jovem
5.
Artigo em Inglês | MEDLINE | ID: mdl-32021155

RESUMO

Rationale: Pulmonary rehabilitation for chronic obstructive pulmonary disease (COPD) reduces dyspnoea and improves exercise capacity and quality of life. The improvement in exercise capacity is variable and unpredictable, however. Respiratory system impedance obtained by forced oscillation technique (FOT) as a measure of ventilatory impairment in COPD may relate to improvement in exercise capacity with pulmonary rehabilitation. We aimed to determine if baseline FOT parameters relate to changes in exercise capacity following pulmonary rehabilitation. Methods: At the start of rehabilitation, 15 COPD subjects (mean(SD) 75.2(6.1) years, FEV1 z-score -2.61(0.84)) had measurements by FOT, spirometry, plethysmographic lung volumes and 6-minute walk distance (6MWD). Respiratory system resistance (Rrs) and reactance (Xrs) parameters as the mean over all breaths (Rmean, Xmean), during inspiration only (Rinsp, Xinsp), and expiratory flow limitation (DeltaXrs = Xinsp-Xexp), were calculated. FOT and 6MWD measurements were repeated at completion of rehabilitation and 3 months after completion. Results: At baseline, Xrs measures were unrelated to 6MWD. Xinsp improved significantly with rehabilitation (from mean(SD) -2.35(1.02) to -2.04(0.85) cmH2O.s.L-1, p=0.008), while other FOT parameters did not. No FOT parameters related to the change in 6MWD at program completion. Baseline Xmean, DeltaXrs, and FVC z-score correlated with the change in 6MWD between completion and 3 months after completion of rehabilitation (rs=0.62, p=0.03; rs=-0.65, p=0.02; and rs=0.62, p=0.03, respectively); with worse ventilatory impairment predicting loss of 6MWD. There were no relationships between Rrs parameters, FEV1 or FEV1/FVC z-scores and changes in 6MWD. Conclusion: Baseline reactance parameters may be helpful in predicting those patients with COPD at most risk of loss of exercise capacity following completion of pulmonary rehabilitation.


Assuntos
Tolerância ao Exercício , Pulmão/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/reabilitação , Testes de Função Respiratória , Teste de Caminhada , Idoso , Idoso de 80 Anos ou mais , Feminino , Volume Expiratório Forçado , Humanos , Masculino , Oscilometria , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Recuperação de Função Fisiológica , Fatores de Tempo , Resultado do Tratamento , Capacidade Vital
6.
ERJ Open Res ; 2(2)2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27730194

RESUMO

The forced oscillation technique (FOT) is gaining clinical acceptance, facilitated by more commercial devices and clinical data. However, the effects of variations in testing protocols used in FOT data acquisition are unknown. We describe the effect of duration of data acquisition on FOT results in subjects with asthma, chronic obstructive pulmonary disease (COPD) and healthy controls. FOT data were acquired from 20 healthy, 22 asthmatic and 18 COPD subjects for 60 s in triplicate. The first 16, 30 and 60 s of each measurement were analysed to obtain total, inspiratory and expiratory resistance of respiratory system (Rrs) and respiratory system reactance (Xrs) at 5 and 19 Hz. With increasing duration, there was a decrease in total and expiratory Rrs for healthy controls, total and inspiratory Rrs for asthmatic subjects and magnitude of total and inspiratory Xrs for COPD subjects at 5 Hz. These decreases were small compared to the differences between clinical groups. Measuring for 16, 30 and 60 s provided ≥3 acceptable breaths in at least 90, 95 and 100% of subjects, respectively. The coefficient of variation for total Rrs and Xrs also decreased with duration. Similar results were found for Rrs and Xrs at 19 Hz. FOT results are statistically, but likely minimally, impacted by acquisition duration in healthy, asthmatic or COPD subjects.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa