Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 261
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Magn Reson Med ; 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38872384

RESUMO

PURPOSE: To develop and validate a highly efficient motion compensated free-breathing isotropic resolution 3D whole-heart joint T1/T2 mapping sequence with anatomical water/fat imaging at 0.55 T. METHODS: The proposed sequence takes advantage of shorter T1 at 0.55 T to acquire three interleaved water/fat volumes with inversion-recovery preparation, no preparation, and T2 preparation, respectively. Image navigators were used to facilitate nonrigid motion-compensated image reconstruction. T1 and T2 maps were jointly calculated by a dictionary matching method. Validations were performed with simulation, phantom, and in vivo experiments on 10 healthy volunteers and 1 patient. The performance of the proposed sequence was compared with conventional 2D mapping sequences including modified Look-Locker inversion recovery and T2-prepared balanced steady-SSFP sequence. RESULTS: The proposed sequence has a good T1 and T2 encoding sensitivity in simulation, and excellent agreement with spin-echo reference T1 and T2 values was observed in a standardized T1/T2 phantom (R2 = 0.99). In vivo experiments provided good-quality co-registered 3D whole-heart T1 and T2 maps with 2-mm isotropic resolution in a short scan time of about 7 min. For healthy volunteers, left-ventricle T1 mean and SD measured by the proposed sequence were both comparable with those of modified Look-Locker inversion recovery (640 ± 35 vs. 630 ± 25 ms [p = 0.44] and 49.9 ± 9.3 vs. 54.4 ± 20.5 ms [p = 0.42]), whereas left-ventricle T2 mean and SD measured by the proposed sequence were both slightly lower than those of T2-prepared balanced SSFP (53.8 ± 5.5 vs. 58.6 ± 3.3 ms [p < 0.01] and 5.2 ± 0.9 vs. 6.1 ± 0.8 ms [p = 0.03]). Myocardial T1 and T2 in the patient measured by the proposed sequence were in good agreement with conventional 2D sequences and late gadolinium enhancement. CONCLUSION: The proposed sequence simultaneously acquires 3D whole-heart T1 and T2 mapping with anatomical water/fat imaging at 0.55 T in a fast and efficient 7-min scan. Further investigation in patients with cardiovascular disease is now warranted.

2.
Magn Reson Med ; 91(5): 1951-1964, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38181169

RESUMO

PURPOSE: Simultaneous PET-MRI improves inflammatory cardiac disease diagnosis. However, challenges persist in respiratory motion and mis-registration between free-breathing 3D PET and 2D breath-held MR images. We propose a free-breathing non-rigid motion-compensated 3D T2 -mapping sequence enabling whole-heart myocardial tissue characterization in a hybrid 3T PET-MR system and provides non-rigid respiratory motion fields to correct also simultaneously acquired PET data. METHODS: Free-breathing 3D whole-heart T2 -mapping was implemented on a hybrid 3T PET-MRI system. Three datasets were acquired with different T2 -preparation modules (0, 28, 55 ms) using 3-fold undersampled variable-density Cartesian trajectory. Respiratory motion was estimated via virtual 3D image navigators, enabling multi-contrast non-rigid motion-corrected MR reconstruction. T2 -maps were computed using dictionary-matching. Approach was tested in phantom, 8 healthy subjects, 14 MR only and 2 PET-MR patients with suspected cardiac disease and compared with spin echo reference (phantom) and clinical 2D T2 -mapping (in-vivo). RESULTS: Phantom results show a high correlation (R2 = 0.996) between proposed approach and gold standard 2D T2 mapping. In-vivo 3D T2 -mapping average values in healthy subjects (39.0 ± 1.4 ms) and patients (healthy tissue) (39.1 ± 1.4 ms) agree with conventional 2D T2 -mapping (healthy = 38.6 ± 1.2 ms, patients = 40.3 ± 1.7 ms). Bland-Altman analysis reveals bias of 1.8 ms and 95% limits of agreement (LOA) of -2.4-6 ms for healthy subjects, and bias of 1.3 ms and 95% LOA of -1.9 to 4.6 ms for patients. CONCLUSION: Validated efficient 3D whole-heart T2 -mapping at hybrid 3T PET-MRI provides myocardial inflammation characterization and non-rigid respiratory motion fields for simultaneous PET data correction. Comparable T2 values were achieved with both 3D and 2D methods. Improved image quality was observed in the PET images after MR-based motion correction.


Assuntos
Miocardite , Miocárdio , Humanos , Imageamento por Ressonância Magnética , Movimento (Física) , Imageamento Tridimensional/métodos , Tomografia por Emissão de Pósitrons , Coração/diagnóstico por imagem , Imagens de Fantasmas
3.
J Cardiovasc Electrophysiol ; 35(2): 258-266, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38065834

RESUMO

BACKGROUND: Incomplete atrial lesions resulting in pulmonary vein-left atrium reconnection after pulmonary vein antrum isolation (PVAI), are related to atrial fibrillation (AF) recurrence. Unfortunately, during the PVAI procedure, fluoroscopy and electroanatomic mapping cannot accurately determine the location and size of the ablation lesions in the atrial wall and this can result in incomplete PVAI lesions (PVAI-L) after radiofrequency catheter ablation (RFCA). AIM: We seek to evaluate whether cardiac magnetic resonance (CMR), immediately after RFCA of AF, can identify PVAI-L by characterizing the left atrial tissue. METHODS: Ten patients (63.1 ± 5.7 years old, 80% male) receiving a RFCA for paroxysmal AF underwent a CMR before (<1 week) and after (<1 h) the PVAI. Two-dimensional dark-blood T2-weighted short tau inversion recovery (DB-STIR), Three-dimensional inversion-recovery prepared long inversion time (3D-TWILITE) and three-dimensional late gadolinium enhancement (3D-LGE) images were performed to visualize PVAI-L. RESULTS: The PVAI-L was visible in 10 patients (100%) using 3D-TWILITE and 3D-LGE. Conversely, On DB-STIR, the ablation core of the PAVI-L could not be identified because of a diffuse high signal of the atrial wall post-PVAI. Microvascular obstruction was identified in 7 (70%) patients using 3D-LGE. CONCLUSION: CMR can visualize PVAI-L immediately after the RFCA of AF even without the use of contrast agents. Future studies are needed to understand if the use of CMR for PVAI-L detection after RFCA can improve the results of ablation procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Meios de Contraste , Resultado do Tratamento , Gadolínio , Espectroscopia de Ressonância Magnética , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia
4.
J Cardiovasc Magn Reson ; 26(1): 101039, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38521391

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) is an important imaging modality for the assessment and management of adult patients with congenital heart disease (CHD). However, conventional techniques for three-dimensional (3D) whole-heart acquisition involve long and unpredictable scan times and methods that accelerate scans via k-space undersampling often rely on long iterative reconstructions. Deep-learning-based reconstruction methods have recently attracted much interest due to their capacity to provide fast reconstructions while often outperforming existing state-of-the-art methods. In this study, we sought to adapt and validate a non-rigid motion-corrected model-based deep learning (MoCo-MoDL) reconstruction framework for 3D whole-heart MRI in a CHD patient cohort. METHODS: The previously proposed deep-learning reconstruction framework MoCo-MoDL, which incorporates a non-rigid motion-estimation network and a denoising regularization network within an unrolled iterative reconstruction, was trained in an end-to-end manner using 39 CHD patient datasets. Once trained, the framework was evaluated in eight CHD patient datasets acquired with seven-fold prospective undersampling. Reconstruction quality was compared with the state-of-the-art non-rigid motion-corrected patch-based low-rank reconstruction method (NR-PROST) and against reference images (acquired with three-or-four-fold undersampling and reconstructed with NR-PROST). RESULTS: Seven-fold undersampled scan times were 2.1 ± 0.3 minutes and reconstruction times were ∼30 seconds, approximately 240 times faster than an NR-PROST reconstruction. Image quality comparable to the reference images was achieved using the proposed MoCo-MoDL framework, with no statistically significant differences found in any of the assessed quantitative or qualitative image quality measures. Additionally, expert image quality scores indicated the MoCo-MoDL reconstructions were consistently of a higher quality than the NR-PROST reconstructions of the same data, with the differences in 12 of the 22 scores measured for individual vascular structures found to be statistically significant. CONCLUSION: The MoCo-MoDL framework was applied to an adult CHD patient cohort, achieving good quality 3D whole-heart images from ∼2-minute scans with reconstruction times of ∼30 seconds.


Assuntos
Aprendizado Profundo , Cardiopatias Congênitas , Interpretação de Imagem Assistida por Computador , Valor Preditivo dos Testes , Humanos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Reprodutibilidade dos Testes , Adulto , Masculino , Feminino , Adulto Jovem , Imageamento Tridimensional , Fatores de Tempo , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética
5.
J Cardiovasc Magn Reson ; 26(1): 100008, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38194762

RESUMO

BACKGROUND: Three dimensional, whole-heart (3DWH) MRI is an established non-invasive imaging modality in patients with congenital heart disease (CHD) for the diagnosis of cardiovascular morphology and for clinical decision making. Current techniques utilise diaphragmatic navigation (dNAV) for respiratory motion correction and gating and are frequently limited by long acquisition times. This study proposes and evaluates the diagnostic performance of a respiratory gating-free framework, which considers respiratory image-based navigation (iNAV), and highly accelerated variable density Cartesian sampling in concert with non-rigid motion correction and low-rank patch-based denoising (iNAV-3DWH-PROST). The method is compared to the clinical dNAV-3DWH sequence in adult patients with CHD. METHODS: In this prospective single center study, adult patients with CHD who underwent the clinical dNAV-3DWH MRI were also scanned with the iNAV-3DWH-PROST. Diagnostic confidence (4-point Likert scale) and diagnostic accuracy for common cardiovascular lesions was assessed by three readers. Scan times and diagnostic confidence were compared using the Wilcoxon-signed rank test. Co-axial vascular dimensions at three anatomic landmarks were measured, and agreement between the research and the corresponding clinical sequence was assessed with Bland-Altman analysis. RESULTS: The study included 60 participants (mean age ± [SD]: 33 ± 14 years; 36 men). The mean acquisition time of iNAV-3DWH-PROST was significantly lower compared with the conventional clinical sequence (3.1 ± 0.9 min vs 13.9 ± 3.9 min, p < 0.0001). Diagnostic confidence was higher for the iNAV-3DWH-PROST sequence compared with the clinical sequence (3.9 ± 0.2 vs 3.4 ± 0.8, p < 0.001), however there was no significant difference in diagnostic accuracy. Narrow limits of agreement and mean bias less than 0.08 cm were found between the research and the clinical vascular measurements. CONCLUSIONS: The iNAV-3DWH-PROST framework provides efficient, high quality and robust 3D whole-heart imaging in significantly shorter scan time compared to the standard clinical sequence.


Assuntos
Cardiopatias Congênitas , Imageamento Tridimensional , Valor Preditivo dos Testes , Humanos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Masculino , Adulto , Estudos Prospectivos , Feminino , Reprodutibilidade dos Testes , Pessoa de Meia-Idade , Fatores de Tempo , Adulto Jovem , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Respiração
6.
Radiology ; 306(1): 150-159, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36040337

RESUMO

Background Liver MR fingerprinting (MRF) enables simultaneous quantification of T1, T2, T2*, and proton density fat fraction (PDFF) maps in single breath-hold acquisitions. Histopathologic correlation studies are desired for its clinical use. Purpose To compare liver MRF-derived metrics with separate reference quantitative MRI in participants with diffuse liver disease, evaluate scan-rescan repeatability of liver MRF, and validate MRF-derived measurements for histologic grading of liver biopsies. Materials and Methods This prospective study included participants with diffuse liver disease undergoing MRI from July 2021 to January 2022. Participants underwent two-dimensional single-section liver MRF and separate reference quantitative MRI. Linear regression, Bland-Altman plots, and coefficients of variation were used to assess the bias and repeatability of liver MRF measurements. For participants undergoing liver biopsy, the association between mapping and histologic grading was evaluated by using the Spearman correlation coefficient. Results Fifty-six participants (mean age, 59 years ± 15 [SD]; 32 women) were included to compare mapping techniques and 23 participants were evaluated with liver biopsy (mean age, 52.7 years ± 12.7; 14 women). The linearity of MRF with reference measurements in participants with diffuse liver disease (R2 value) for T1, T2, T2*, and PDFF maps was 0.86, 0.88, 0.54, and 0.99, respectively. The overall coefficients of variation for repeatability in the liver were 3.2%, 5.5%, 7.1%, and 4.6% for T1, T2, T2*, and PDFF maps, respectively. MRF-derived metrics showed high diagnostic performance in differentiating moderate or severe changes from mild or no changes (area under the receiver operating characteristic curve for fibrosis, inflammation, steatosis, and siderosis: 0.62 [95% CI: 0.52, 0.62], 0.92 [95% CI: 0.88, 0.92], 0.97 [95% CI: 0.96, 0.97], and 0.74 [95% CI: 0.57, 0.74], respectively). Conclusion Liver MR fingerprinting provided repeatable T1, T2, T2*, and proton density fat fraction maps in high agreement with reference quantitative mapping and may correlate with pathologic grades in participants with diffuse liver disease. © RSNA, 2022 Online supplemental material is available for this article.


Assuntos
Fígado Gorduroso , Prótons , Humanos , Feminino , Pessoa de Meia-Idade , Correlação de Dados , Estudos Prospectivos , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Fígado Gorduroso/patologia
7.
Magn Reson Med ; 89(1): 217-232, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36198014

RESUMO

PURPOSE: To introduce non-rigid cardiac motion correction into a novel free-running framework for the simultaneous acquisition of 3D whole-heart myocardial T 1 $$ {T}_1 $$ and T 2 $$ {T}_2 $$ maps and cine images, enabling a ∼ $$ \sim $$ 3-min scan. METHODS: Data were acquired using a free-running 3D golden-angle radial readout interleaved with inversion recovery and T 2 $$ {T}_2 $$ -preparation pulses. After correction for translational respiratory motion, non-rigid cardiac-motion-corrected reconstruction with dictionary-based low-rank compression and patch-based regularization enabled 3D whole-heart T 1 $$ {T}_1 $$ and T 2 $$ {T}_2 $$ mapping at any given cardiac phase as well as whole-heart cardiac cine imaging. The framework was validated and compared with established methods in 11 healthy subjects. RESULTS: Good quality 3D T 1 $$ {T}_1 $$ and T 2 $$ {T}_2 $$ maps and cine images were reconstructed for all subjects. Septal T 1 $$ {T}_1 $$ values using the proposed approach ( 1200 ± 50 $$ 1200\pm 50 $$ ms) were higher than those from a 2D MOLLI sequence ( 1063 ± 33 $$ 1063\pm 33 $$ ms), which is known to underestimate T 1 $$ {T}_1 $$ , while T 2 $$ {T}_2 $$ values from the proposed approach ( 51 ± 4 $$ 51\pm 4 $$ ms) were in good agreement with those from a 2D GraSE sequence ( 51 ± 2 $$ 51\pm 2 $$ ms). CONCLUSION: The proposed technique provides 3D T 1 $$ {T}_1 $$ and T 2 $$ {T}_2 $$ maps and cine images with isotropic spatial resolution in a single ∼ $$ \sim $$ 3.3-min scan.


Assuntos
Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Coração/diagnóstico por imagem , Miocárdio , Movimento (Física) , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética , Imagens de Fantasmas
8.
NMR Biomed ; 36(8): e4932, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36940044

RESUMO

Nonalcoholic fatty liver disease (NAFLD) is the leading cause of chronic liver disease worldwide. Liver biopsy remains the gold standard for diagnosis and staging of disease. There is a clinical need for noninvasive diagnostic tools for risk stratification, follow-up, and monitoring treatment response that are currently lacking, as well as preclinical models that recapitulate the etiology of the human condition. We have characterized the progression of NAFLD in eNOS-/- mice fed a high fat diet (HFD) using noninvasive Dixon-based magnetic resonance imaging and single voxel STEAM spectroscopy-based protocols to measure liver fat fraction at 3 T. After 8 weeks of diet intervention, eNOS-/- mice exhibited significant accumulation of intra-abdominal and liver fat compared with control mice. Liver fat fraction measured by 1 H-MRS in vivo showed a good correlation with the NAFLD activity score measured by histology. Treatment of HFD-fed NOS3-/- mice with metformin showed significantly reduced liver fat fraction and altered hepatic lipidomic profile compared with untreated mice. Our results show the potential of in vivo liver MRI and 1 H-MRS to noninvasively diagnose and stage the progression of NAFLD and to monitor treatment response in an eNOS-/- murine model that represents the classic NAFLD phenotype associated with metabolic syndrome.


Assuntos
Metformina , Hepatopatia Gordurosa não Alcoólica , Humanos , Animais , Camundongos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/tratamento farmacológico , Hepatopatia Gordurosa não Alcoólica/metabolismo , Ácidos Graxos/metabolismo , Metformina/farmacologia , Metformina/uso terapêutico , Modelos Animais de Doenças , Fígado/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Camundongos Endogâmicos C57BL
9.
J Magn Reson Imaging ; 57(2): 387-402, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36205716

RESUMO

Magnetic resonance imaging (MRI) is a versatile modality that can generate high-resolution images with a variety of tissue contrasts. However, MRI is a slow technique and requires long acquisition times, which increase with higher temporal and spatial resolution and/or when multiple contrasts and large volumetric coverage is required. In order to speedup MR data acquisition, several approaches have been introduced in the literature. Most of these techniques acquire less data than required and exploit intrinsic redundancies in the MR images to recover the information that was not sampled. This article presents a review of MR acquisition and reconstruction methods that have exploited redundancies in the temporal, spatial, and contrast/parametric dimensions to accelerate image data acquisition, focusing on cardiac and abdominal MR imaging applications. The review describes how each of these dimensions has been separately exploited for speeding up MR acquisition to then discuss more advanced techniques where multiple dimensions are exploited together for further reducing scan times. Finally, future directions for multidimensional image acceleration and remaining technical challenges are discussed. EVIDENCE LEVEL: 5 TECHNICAL EFFICACY: 1.


Assuntos
Coração , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Coração/diagnóstico por imagem , Aceleração , Processamento de Imagem Assistida por Computador/métodos
10.
J Magn Reson Imaging ; 57(2): 521-531, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35642573

RESUMO

BACKGROUND: Cardiac MRI plays an important role in the diagnosis and follow-up of patients with congenital heart disease (CHD). Gadolinium-based contrast agents are often needed to overcome flow-related and off-resonance artifacts that can impair the quality of conventional noncontrast 3D imaging. As serial imaging is often required in CHD, the development of robust noncontrast 3D MRI techniques is desirable. PURPOSE: To assess the clinical utility of noncontrast enhanced magnetization transfer and inversion recovery prepared 3D free-breathing sequence (MTC-BOOST) compared to conventional 3D whole heart imaging in patients with CHD. STUDY TYPE: Prospective, image quality. POPULATION: A total of 27 adult patients (44% female, mean age 30.9 ± 14.8 years) with CHD. FIELD STRENGTH/SEQUENCE: A 1.5 T; free-breathing 3D MTC-BOOST sequence. ASSESSMENT: MTC-BOOST was compared to diaphragmatic navigator-gated, noncontrast T2 prepared 3D whole-heart imaging sequence (T2prep-3DWH) for comparison of vessel dimensions, lumen-to-myocardium contrast ratio (CR), and image quality (vessel wall sharpness and presence and type of artifacts) assessed by two experienced cardiologists on a 5-point scale. STATISTICAL TESTS: Mann-Whitney test, paired Wilcoxon signed-rank test, Bland-Altman plots. P < 0.05 was considered statistically significant. RESULTS: MTC-BOOST significantly improved image quality and CR of the right-sided pulmonary veins (PV): (CR: right upper PV 1.06 ± 0.50 vs. 0.58 ± 0.74; right lower PV 1.32 ± 0.38 vs. 0.81 ± 0.73) compared to conventional T2prep-3DWH imaging where the PVs were not visualized in some cases due to off-resonance effects. MTC-BOOST demonstrated resistance to degradation of luminal signal (assessed by CR) secondary to accelerated or turbulent flow conditions. T2prep-3DWH had higher image quality scores than MTC-BOOST for the aorta and coronary arteries; however, great vessel dimensions derived from MTC-BOOST showed excellent agreement with standard T2prep-3DWH imaging. DATA CONCLUSION: MTC-BOOST allows for improved contrast-free imaging of pulmonary veins and regions characterized by accelerated or turbulent blood flow compared to standard T2prep-3DWH imaging, with excellent agreement of great vessel dimensions. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.


Assuntos
Cardiopatias Congênitas , Veias Pulmonares , Humanos , Adulto , Feminino , Adolescente , Adulto Jovem , Pessoa de Meia-Idade , Masculino , Veias Pulmonares/diagnóstico por imagem , Estudos Prospectivos , Angiografia por Ressonância Magnética/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Meios de Contraste , Imageamento Tridimensional/métodos , Reprodutibilidade dos Testes
11.
J Magn Reson Imaging ; 58(4): 1110-1122, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36757267

RESUMO

BACKGROUND: Bright-blood lumen and black-blood vessel wall imaging are required for the comprehensive assessment of aortic disease. These images are usually acquired separately, resulting in long examinations and potential misregistration between images. PURPOSE: To characterize the performance of an accelerated and respiratory motion-compensated three-dimensional (3D) cardiac MRI technique for simultaneous contrast-free aortic lumen and vessel wall imaging with an interleaved T2 and inversion recovery prepared sequence (iT2Prep-BOOST). STUDY TYPE: Prospective. POPULATION: A total of 30 consecutive patients with aortopathy referred for a clinically indicated cardiac MRI examination (9 females, mean age ± standard deviation: 32 ± 12 years). FIELD STRENGTH/SEQUENCE: 1.5-T; bright-blood MR angiography (diaphragmatic navigator-gated T2-prepared 3D balanced steady-state free precession [bSSFP], T2Prep-bSSFP), breath-held black-blood two-dimensional (2D) half acquisition single-shot turbo spin echo (HASTE), and 3D bSSFP iT2Prep-BOOST. ASSESSMENT: iT2Prep-BOOST bright-blood images were compared to T2prep-bSSFP images in terms of aortic vessel dimensions, lumen-to-myocardium contrast ratio (CR), and image quality (diagnostic confidence, vessel sharpness and presence of artifacts, assessed by three cardiologists on a 4-point scale, 1: nondiagnostic to 4: excellent). The iT2Prep-BOOST black-blood images were compared to 2D HASTE images for quantification of wall thickness. A visual comparison between computed tomography (CT) and iT2Prep-BOOST was performed in a patient with chronic aortic dissection. STATISTICAL TESTS: Paired t-tests, Wilcoxon signed-rank tests, intraclass correlation coefficient (ICC), Bland-Altman analysis. A P value < 0.05 was considered statistically significant. RESULTS: Bright-blood iT2Prep-BOOST resulted in significantly improved image quality (mean ± standard deviation 3.8 ± 0.5 vs. 3.3 ± 0.8) and CR (2.9 ± 0.8 vs. 1.8 ± 0.5) compared with T2Prep-bSSFP, with a shorter scan time (7.8 ± 1.7 minutes vs. 12.9 ± 3.4 minutes) while providing a complementary 3D black-blood image. Aortic lumen diameter and vessel wall thickness measurements in bright-blood and black-blood images were in good agreement with T2Prep-bSSFP and HASTE images (<0.02 cm and <0.005 cm bias, respectively) and good intrareader (ICC > 0.96) and interreader (ICC > 0.94) agreement was observed for all measurements. DATA CONCLUSION: iT2Prep-BOOST might enable time-efficient simultaneous bright- and black-blood aortic imaging, with improved image quality compared to T2Prep-bSSFP and HASTE imaging, and comparable measurements for aortic wall and lumen dimensions. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 2.


Assuntos
Doenças da Aorta , Angiografia por Ressonância Magnética , Feminino , Humanos , Angiografia por Ressonância Magnética/métodos , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Doenças da Aorta/diagnóstico por imagem , Miocárdio , Imageamento Tridimensional/métodos , Reprodutibilidade dos Testes
12.
J Cardiovasc Magn Reson ; 25(1): 52, 2023 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-37779192

RESUMO

BACKGROUND: Coronary magnetic resonance angiography (coronary MRA) is increasingly being considered as a clinically viable method to investigate coronary artery disease (CAD). Accurate determination of the trigger delay to place the acquisition window within the quiescent part of the cardiac cycle is critical for coronary MRA in order to reduce cardiac motion. This is currently reliant on operator-led decision making, which can negatively affect consistency of scan acquisition. Recently developed deep learning (DL) derived software may overcome these issues by automation of cardiac rest period detection. METHODS: Thirty individuals (female, n = 10) were investigated using a 0.9 mm isotropic image-navigator (iNAV)-based motion-corrected coronary MRA sequence. Each individual was scanned three times utilising different strategies for determination of the optimal trigger delay: (1) the DL software, (2) an experienced operator decision, and (3) a previously utilised formula for determining the trigger delay. Methodologies were compared using custom-made analysis software to assess visible coronary vessel length and coronary vessel sharpness for the entire vessel length and the first 4 cm of each vessel. RESULTS: There was no difference in image quality between any of the methodologies for determination of the optimal trigger delay, as assessed by visible coronary vessel length, coronary vessel sharpness for each entire vessel and vessel sharpness for the first 4 cm of the left mainstem, left anterior descending or right coronary arteries. However, vessel length of the left circumflex was slightly greater using the formula method. The time taken to calculate the trigger delay was significantly lower for the DL-method as compared to the operator-led approach (106 ± 38.0 s vs 168 ± 39.2 s, p < 0.01, 95% CI of difference 25.5-98.1 s). CONCLUSIONS: Deep learning-derived automated software can effectively and efficiently determine the optimal trigger delay for acquisition of coronary MRA and thus may simplify workflow and improve reproducibility.


Assuntos
Coração , Angiografia por Ressonância Magnética , Humanos , Feminino , Angiografia por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Angiografia Coronária/métodos , Imageamento Tridimensional
13.
Magn Reson Med ; 87(4): 1980-1991, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34792212

RESUMO

PURPOSE: To develop a novel simultaneous co-registered T1 , T2 , T2∗ , T1ρ , and fat fraction abdominal MR fingerprinting (MRF) approach for fully comprehensive liver-tissue characterization in a single breath-hold scan. METHODS: A gradient-echo liver MRF sequence with low fixed flip angle, multi-echo radial readout, and varying magnetization preparation pulses for multiparametric encoding is performed at 1.5 T. The T2∗ and fat fraction are estimated from a graph/cut water/fat separation method using a six-peak fat model. Water/fat singular images obtained are then matched to an MRF dictionary, estimating water-specific T1 , T2 , and T1ρ . The proposed approach was tested in phantoms and 10 healthy subjects and compared against conventional sequences. RESULTS: For the phantom studies, linear fits show excellent coefficients of determination (r2 > 0.9) for every parametric map. For in vivo studies, the average values measured within regions of interest drawn on liver, spleen, muscle, and fat are statistically different from the reference scans (p < 0.05) for T1 , T2 , and T1⍴ but not for T2∗ and fat fraction, whereas correlation between MRF and reference scans is excellent for each parameter (r2 > 0.92 for every parameter). CONCLUSION: The proposed multi-echo inversion-recovery, T2 , and T1⍴ prepared liver MRF sequence presented in this work allows for quantitative T1 , T2 , T2∗ , T1⍴ , and fat fraction liver-tissue characterization in a single breath-hold scan of 18 seconds. The approach showed good agreement and correlation with respect to reference clinical maps.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Suspensão da Respiração , Humanos , Processamento de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
14.
Magn Reson Med ; 87(4): 1992-2002, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34799854

RESUMO

PURPOSE: To develop a simultaneous T1 , T2 , and T1ρ cardiac magnetic resonance fingerprinting (MRF) approach to enable comprehensive contrast agent-free myocardial tissue characterization in a single breath-hold scan. METHODS: A 2D gradient-echo electrocardiogram-triggered cardiac MRF sequence with low flip angles, varying magnetization preparation, and spiral trajectory was acquired at 1.5 T to encode T1 , T2 , and T1⍴ simultaneously. The MRF images were reconstructed using low-rank inversion, regularized with a multicontrast patch-based higher-order reconstruction. Parametric maps were generated and matched in the singular value domain to extended phase graph-based dictionaries. The proposed approach was tested in phantoms and 10 healthy subjects and compared against conventional methods in terms of coefficients of determination and best fits for the phantom study, and in terms of Bland-Altman agreement, average values and coefficient of variation of T1 , T2 , and T1⍴ for the healthy subjects study. RESULTS: The T1 , T2 , and T1⍴ MRF values showed excellent correlation with conventional spin-echo and clinical mapping methods in phantom studies (r2 > 0.97). Measured MRF values in myocardial tissue (mean ± SD) were 1133 ± 33 ms, 38.8 ± 3.5 ms, and 52.0 ± 4.0 ms for T1 , T2 and T1⍴ , respectively, against 1053 ± 47 ms, 50.4 ± 3.9 ms, and 55.9 ± 3.3 ms for T1 modified Look-Locker inversion imaging, T2 gradient and spin echo, and T1⍴ turbo field echo, respectively. CONCLUSION: A cardiac MRF approach for simultaneous quantification of myocardial T1 , T2 , and T1ρ in a single breath-hold MR scan of about 16 seconds has been proposed. The approach has been investigated in phantoms and healthy subjects showing good agreement with reference spin echo measurements and conventional clinical maps.


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética , Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas
15.
J Cardiovasc Magn Reson ; 24(1): 5, 2022 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-35000609

RESUMO

BACKGROUND: The application of cardiovascular magnetic resonance angiography (CMRA) for the assessment of thoracic aortic disease is often associated with prolonged and unpredictable acquisition times and residual motion artefacts. To overcome these limitations, we have integrated undersampled acquisition with image-based navigators and inline non-rigid motion correction to enable a free-breathing, contrast-free Cartesian CMRA framework for the visualization of the thoracic aorta in a short and predictable scan of 3 min. METHODS: 35 patients with thoracic aortic disease (36 ± 13y, 14 female) were prospectively enrolled in this single-center study. The proposed 3D T2-prepared balanced steady state free precession (bSSFP) sequence with image-based navigator (iNAV) was compared to the clinical 3D T2-prepared bSSFP with diaphragmatic-navigator gating (dNAV), in terms of image acquisition time. Three cardiologists blinded to iNAV vs. dNAV acquisition, recorded image quality scores across four aortic segments and their overall diagnostic confidence. Contrast ratio (CR) and relative standard deviation (RSD) of signal intensity (SI) in the corresponding segments were estimated. Co-axial aortic dimensions in six landmarks were measured by two readers to evaluate the agreement between the two methods, along with inter-observer and intra-observer agreement. Kolmogorov-Smirnov test, Mann-Whitney U (MWU), Bland-Altman analysis (BAA), intraclass correlation coefficient (ICC) were used for statistical analysis. RESULTS: The scan time for the iNAV-based approach was significantly shorter (3.1 ± 0.5 min vs. 12.0 ± 3.0 min for dNAV, P = 0.005). Reconstruction was performed inline in 3.0 ± 0.3 min. Diagnostic confidence was similar for the proposed iNAV versus dNAV for all three reviewers (Reviewer 1: 3.9 ± 0.3 vs. 3.8 ± 0.4, P = 0.7; Reviewer 2: 4.0 ± 0.2 vs. 3.9 ± 0.3, P = 0.4; Reviewer 3: 3.8 ± 0.4 vs. 3.7 ± 0.6, P = 0.3). The proposed method yielded higher image quality scores in terms of artefacts from respiratory motion, and non-diagnostic images due to signal inhomogeneity were observed less frequently. While the dNAV approach outperformed the iNAV method in the CR assessment, the iNAV sequence showed improved signal homogeneity along the entire thoracic aorta [RSD SI 5.1 (4.4, 6.5) vs. 6.5 (4.6, 8.6), P = 0.002]. BAA showed a mean difference of < 0.05 cm across the 6 landmarks between the two datasets. ICC showed excellent inter- and intra-observer reproducibility. CONCLUSIONS: Thoracic aortic iNAV-based CMRA with fast acquisition (~ 3 min) and inline reconstruction (3 min) is proposed, resulting in high diagnostic confidence and reproducible aortic measurements.


Assuntos
Aorta Torácica , Angiografia por Ressonância Magnética , Aorta Torácica/diagnóstico por imagem , Feminino , Coração , Humanos , Imageamento Tridimensional , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
16.
J Cardiovasc Magn Reson ; 24(1): 44, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35864534

RESUMO

Cardiovascular magnetic resonance (CMR) is widely used for diagnostic imaging in the pediatric population. In addition to structural congenital heart disease (CHD), for which published guidelines are available, CMR is also performed for non-structural pediatric heart disease, for which guidelines are not available. This article provides guidelines for the performance and reporting of CMR in the pediatric population for non-structural ("non-congenital") heart disease, including cardiomyopathies, myocarditis, Kawasaki disease and systemic vasculitides, cardiac tumors, pericardial disease, pulmonary hypertension, heart transplant, and aortopathies. Given important differences in disease pathophysiology and clinical manifestations as well as unique technical challenges related to body size, heart rate, and sedation needs, these guidelines focus on optimization of the CMR examination in infants and children compared to adults. Disease states are discussed, including the goals of CMR examination, disease-specific protocols, and limitations and pitfalls, as well as newer techniques that remain under development.


Assuntos
Cardiopatias Congênitas , Imageamento por Ressonância Magnética , Adulto , Criança , Consenso , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Humanos , Lactente , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes
17.
Radiology ; 298(3): 578-586, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33464179

RESUMO

Background Clinical guidelines recommend the use of established T2 mapping sequences to detect and quantify myocarditis and edema, but T2 mapping is performed in two dimensions with limited coverage and repetitive breath holds. Purpose To assess the reproducibility of an accelerated free-breathing three-dimensional (3D) whole-heart T2 MRI mapping sequence in phantoms and participants without a history of cardiac disease and to investigate its clinical performance in participants with suspected myocarditis. Materials and Methods Eight participants (three women, mean age, 31 years ± 4 [standard deviation]; cohort 1) without a history of cardiac disease and 25 participants (nine women, mean age, 45 years ± 17; cohort 2) with clinically suspected myocarditis underwent accelerated free-breathing 3D whole-heart T2 mapping with 100% respiratory scanning efficiency at 1.5 T. The participants were enrolled from November 2018 to August 2020. Three repeated scans were performed on 2 separate days in cohort 1. Segmental variations in T2 relaxation times of the left ventricular myocardium were assessed, and intrasession and intersession reproducibility were measured. In cohort 2, segmental myocardial T2 values, detection of focal inflammation, and map quality were compared with those obtained from clinical breath-hold two-dimensional (2D) T2 mapping. Statistical differences were assessed using the nonparametric Mann-Whitney and Kruskal-Wallis tests, whereas the paired Wilcoxon signed-rank test was used to assess subjective scores. Results Whole-heart T2 maps were acquired in a mean time of 6 minutes 53 seconds ± 1 minute 5 seconds at 1.5 mm3 resolution. Breath-hold 2D and free-breathing 3D T2 mapping had similar intrasession (mean T2 change of 3.2% and 2.3% for 2D and 3D, respectively) and intersession (4.8% and 4.9%, respectively) reproducibility. The two T2 mapping sequences showed similar map quality (P = .23, cohort 2). Abnormal myocardial segments were identified with confidence (score 3) in 14 of 25 participants (56%) with 3D T2 mapping and only in 10 of 25 participants (40%) with 2D T2 mapping. Conclusion High-spatial-resolution three-dimensional (3D) whole-heart T2 mapping shows high intrasession and intersession reproducibility and helps provide T2 myocardial characterization in agreement with clinical two-dimensional reference, while enabling 3D assessment of focal disease with higher confidence. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Friedrich in this issue.


Assuntos
Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Miocardite/diagnóstico por imagem , Adulto , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Estudos Prospectivos , Reprodutibilidade dos Testes
18.
Magn Reson Med ; 85(4): 2069-2083, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33201524

RESUMO

PURPOSE: To develop a novel gadolinium-free model-based quantitative magnetization transfer (qMT) technique to assess macromolecular changes associated with myocardial fibrosis. METHODS: The proposed sequence consists of a two-dimensional breath-held dual shot interleaved acquisition of five MT-weighted (MTw) spoiled gradient echo images, with variable MT flip angles (FAs) and off-resonance frequencies. A two-pool exchange model and dictionary matching were used to quantify the pool size ratio (PSR) and bound pool T2 relaxation ( T2B ). The signal model was developed and validated using 25 MTw images on a bovine serum albumin (BSA) phantom and in vivo human thigh muscle. A protocol with five MTw images was optimized for single breath-hold cardiac qMT imaging. The proposed sequence was tested in 10 healthy subjects and 5 patients with myocardial fibrosis and compared to late gadolinium enhancement (LGE). RESULTS: PSR values in the BSA phantom were within the confidence interval of previously reported values (concentration 10% BSA = 5.9 ± 0.1%, 15% BSA = 9.4 ± 0.2%). PSR and T2B in thigh muscle were also in agreement with literature (PSR = 10.9 ± 0.3%, T2B = 6.4 ± 0.4 us). In 10 healthy subjects, global left ventricular PSR was 4.30 ± 0.65%. In patients, PSR was reduced in areas associated with LGE (remote: 4.68 ± 0.70% vs. fibrotic: 3.12 ± 0.78 %, n = 5, P < .002). CONCLUSION: In vivo model-based qMT mapping of the heart was performed for the first time, with promising results for non-contrast enhanced assessment of myocardial fibrosis.


Assuntos
Cardiomiopatias , Meios de Contraste , Cardiomiopatias/diagnóstico por imagem , Fibrose , Gadolínio , Humanos , Imageamento por Ressonância Magnética
19.
J Magn Reson Imaging ; 53(4): 1253-1265, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33124081

RESUMO

BACKGROUND: Dixon cardiac magnetic resonance fingerprinting (MRF) has been recently introduced to simultaneously provide water T1 , water T2 , and fat fraction (FF) maps. PURPOSE: To assess Dixon cardiac MRF repeatability in healthy subjects and its clinical feasibility in a cohort of patients with cardiovascular disease. POPULATION: T1MES phantom, water-fat phantom, 11 healthy subjects and 19 patients with suspected cardiovascular disease. STUDY TYPE: Prospective. FIELD STRENGTH/SEQUENCE: 1.5T, inversion recovery spin echo (IRSE), multiecho spin echo (MESE), modified Look-Locker inversion recovery (MOLLI), T2 gradient spin echo (T2 -GRASE), 6-echo gradient rewound echo (GRE), and Dixon cardiac MRF. ASSESSMENT: Dixon cardiac MRF precision was assessed through repeated scans against conventional MOLLI, T2 -GRASE, and PDFF in phantom and 11 healthy subjects. Dixon cardiac MRF native T1 , T2 , FF, postcontrast T1 and synthetic extracellular volume (ECV) maps were assessed in 19 patients in comparison to conventional sequences. Measurements in patients were performed in the septum and in late gadolinium enhanced (LGE) areas and assessed using mean value distributions, correlation, and Bland-Altman plots. Image quality and diagnostic confidence were assessed by three experts using 5-point scoring scales. STATISTICAL TESTS: Paired Wilcoxon rank signed test and paired t-tests were applied. Statistical significance was indicated by *(P < 0.05). RESULTS: Dixon cardiac MRF showed good overall precision in phantom and in vivo. Septal average repeatability was ~23 msec for T1 , ~2.2 msec for T2 , and ~1% for FF. Biases in healthy subjects/patients were measured at +37 msec*/+60 msec* and -8.8 msec*/-8 msec* when compared to MOLLI and T2 -GRASE, respectively. No statistically significant differences in postcontrast T1 (P = 0.17) and synthetic ECV (P = 0.19) measurements were observed in patients. DATA CONCLUSION: Dixon cardiac MRF attained good overall precision in phantom and healthy subjects, while providing coregistered T1 , T2 , and fat fraction maps in a single breath-hold scan with similar or better image quality than conventional methods in patients. LEVEL OF EVIDENCE: 2. TECHNICAL EFFICACY STAGE: 2.


Assuntos
Coração , Imageamento por Ressonância Magnética , Coração/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Estudos Prospectivos , Reprodutibilidade dos Testes
20.
Arterioscler Thromb Vasc Biol ; 40(9): 2159-2170, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32673527

RESUMO

OBJECTIVE: Evidence from preclinical and clinical studies has demonstrated that myocardial infarction promotes atherosclerosis progression. The impact of focal vascular inflammation on the progression and phenotype of remote atherosclerosis remains unknown. Approach and Results: We used a novel ApoE-/- knockout mouse model of sustained arterial inflammation, initiated by mechanical injury in the abdominal aorta. Using serial in vivo molecular MRI and ex vivo histology and flow cytometry, we demonstrate that focal arterial inflammation triggered by aortic injury, accelerates atherosclerosis in the remote brachiocephalic artery. The brachiocephalic artery atheroma had distinct histological features including increased plaque size, plaque permeability, necrotic core to collagen ratio, infiltration of more inflammatory monocyte subsets, and reduced collagen content. We also found that arterial inflammation following focal vascular injury evoked a prolonged systemic inflammatory response manifested as a persistent increase in serum IL-6 (interleukin 6). Finally, we demonstrate that 2 therapeutic interventions-pravastatin and minocycline-had distinct anti-inflammatory effects at the plaque and systemic level. CONCLUSIONS: We show for the first time that focal arterial inflammation in response to vascular injury enhances systemic vascular inflammation, accelerates remote atheroma progression and induces plaques more inflamed, lipid-rich, and collagen-poor in the absence of ischemic myocardial injury. This inflammatory cascade is modulated by pravastatin and minocycline treatments, which have anti-inflammatory effects at both plaque and systemic levels that mitigate atheroma progression.


Assuntos
Aortite/complicações , Aterosclerose/etiologia , Tronco Braquiocefálico/metabolismo , Mediadores da Inflamação/sangue , Placa Aterosclerótica , Animais , Anti-Inflamatórios/farmacologia , Aortite/sangue , Aortite/patologia , Aterosclerose/sangue , Aterosclerose/patologia , Aterosclerose/prevenção & controle , Tronco Braquiocefálico/efeitos dos fármacos , Tronco Braquiocefálico/patologia , Colágeno/metabolismo , Modelos Animais de Doenças , Progressão da Doença , Interleucina-6/sangue , Metabolismo dos Lipídeos , Masculino , Camundongos Knockout para ApoE , Minociclina/farmacologia , Necrose , Pravastatina/farmacologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa