Appl Radiat Isot ; 158: 109044, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31989933

RESUMO

The SnO268Ge/68Ga generator system is widely used in medical imaging to provide a regular supply of the radionuclide 68Ga (T½ = 68.3 min) for positron emission tomography (PET). These generators are also used to supply 68Ga for the fabrication of tracer particles for application in positron emission particle tracking (PEPT). The tracer particles are fabricated by radiolabelling ion exchange resins such as Purolite NRW100 with 68Ga; however, contaminants from the degradation of the SnO2 column over time interfere with the uptake of 68Ga. The major contaminants are Zn(II), Fe(III) and Sn(IV) with 68Ge (IV) being eluted from the column as it degrades. This paper describes an improved method to purify the 68Ga supply using an Amberchrom CG-71m absorption resin column integrated into a newly designed separation panel. This method reduces the amount of Zn(II) and Fe(III) in the 68Ga eluate and improves the radiolabelling performance by more than 10% when compared to the un-purified product. The method can extend the life-span of the generator by several months.

2.
Radiat Prot Dosimetry ; 126(1-4): 218-22, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17575291

RESUMO

A compact liquid organic neutron spectrometer based on a single NE213 liquid scintillator (5 cm diameter x 5 cm) is described. The spectrometer is designed to measure neutron fluence spectra over the energy range 2-200 MeV and is suitable for use in neutron fields having any type of time structure. Neutron fluence spectra are obtained from measurements of two-parameter distributions (counts versus pulse-height and pulse shape) using the Bayesian unfolding code MAXED. Calibration and test measurements made using a pulsed neutron beam with a continuous energy spectrum are described and the application of the spectrometer to radiation dose measurements is discussed.


Assuntos
Nêutrons , Compostos Orgânicos/química , Compostos Orgânicos/efeitos da radiação , Radiometria/instrumentação , Radiometria/métodos , Análise Espectral/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Soluções
3.
Radiat Prot Dosimetry ; 126(1-4): 346-9, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17545657

RESUMO

A NE230 deuterated liquid scintillator detector (25 mm diameter x 25 mm) has been used to investigate neutron energy spectra as a function of position in a water phantom under irradiation by a quasi-monoenergetic 64 MeV neutron beam. Neutron energy spectra are obtained from measurements of pulse height spectra by the NE230 detector using the Bayesian unfolding code MAXED. The experimentally measured energy spectra are compared with spectra calculated by Monte Carlo simulation using the code MCNPX.


Assuntos
Nêutrons , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Contagem de Cintilação/instrumentação , Análise Espectral/instrumentação , Água/química , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Espalhamento de Radiação , Contagem de Cintilação/métodos , Sensibilidade e Especificidade , Análise Espectral/métodos
4.
Med Phys ; 19(5): 1285-91, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1435611

RESUMO

High-resolution neutron fluence spectra have been measured in the National Accelerator Centre's p(66)/Be(40) neutron therapy beam by the pulsed-beam time-of-flight method. ICRU muscle kerma spectra have been derived from the fluence spectra. Spectral changes resulting from different irradiation conditions have been quantified in terms of the average neutron energy and the fractional low-energy (< 16 MeV) contribution. The changes observed with different thicknesses of polyethylene filtration are consistent with changes in quality parameters determined in biological and microdosimetric experiments. The dosimetry parameters (KtissueA150) N and (Wgas) N calculated for the measured spectra agree with the values recommended in the neutron dosimetry protocol. The shapes of the present fluence spectra differ from previous measurements of p(> 40)/Be spectra. In particular, they differ significantly from the spectrum measured by recoil techniques in an identical neutron therapy unit at the Clatterbridge Hospital, UK. The reasons for the difference are not known.


Assuntos
Berílio , Terapia por Captura de Nêutron , Humanos , Matemática , Músculos/efeitos da radiação , Terapia por Captura de Nêutron/métodos , Dosagem Radioterapêutica
5.
Hernia ; 5(2): 88-91, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11505655

RESUMO

Laparoscopic treatment of inguinal hernias has expanded rapidly during the last decade. Several studies have evaluated the early results of this technique, and the rate of recurrence was estimated less than 5% with a range from 0.5% to 10%. The long-term recurrence after such treatment is still not well known. This study reports the 2 year follow-up of laparoscopic treatment of 236 inguinal hernias (220 patients) from January 1996 to December 1997. All patients were contacted by telephone, 196 (90%) (193 men and 3 women) were examined by a senior surgeon. The average time from operation to examination was 34 months (range 20-42 months). We observed a 15% recurrence rate (35 hernias in 34 patients) of which 5% (12 cases) were symptomatic but 10% (23 cases) were totally asymptomatic and diagnosed on clinical examination. The postoperative inguinal haematoma and the physical activity of the patients seem to predispose the recurrence. Chronic pain was rarely observed in this study.


Assuntos
Hérnia Inguinal/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Laparoscopia , Masculino , Pessoa de Meia-Idade , Recidiva , Fatores de Tempo
6.
Appl Radiat Isot ; 61(1): 27-34, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15145435

RESUMO

Four methods for employing neutrons to detect abandoned small anti-personnel landmines are presented and discussed. The techniques used are based on measurements of effects due to the scattering of neutrons on the hydrogen content of the landmine.


Assuntos
Traumatismos por Explosões/prevenção & controle , Nêutrons , Simulação por Computador , Humanos , Hidrogênio/química , Método de Monte Carlo , Espalhamento de Radiação , Guerra
7.
Radiat Prot Dosimetry ; 110(1-4): 151-5, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15353638

RESUMO

A stacked scintillator neutron spectrometer (S3N) consisting of three slabs of liquid organic scintillator is described. A pulsed beam providing a broad spectrum of neutron energies is used to determine the detection efficiency of the spectrometer as a function of incident neutron energy and to measure the pulse height response matrix of the system. Neutron spectra can then be determined for beams with any kind of time structure by unfolding pulse height spectra measured by the S3N. Examples of fluence spectrum measurements in the energy range 20-150 MeV are presented.


Assuntos
Nêutrons , Radioisótopos/análise , Contagem de Cintilação/instrumentação , Contagem de Cintilação/métodos , Análise Espectral/instrumentação , Análise Espectral/normas , Calibragem/normas , Guias como Assunto , Transferência Linear de Energia , Padrões de Referência , Reprodutibilidade dos Testes , Espalhamento de Radiação , Contagem de Cintilação/normas , Sensibilidade e Especificidade , África do Sul , Análise Espectral/métodos
8.
Radiat Prot Dosimetry ; 110(1-4): 97-102, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15353629

RESUMO

Well-characterised neutron fields are a prerequisite for the investigation of neutron detectors. Partly in collaboration with external partners, the PTB neutron metrology group makes available for other users neutron reference fields covering the full energy range from thermal to 200 MeV. The specification of the neutron fluence in these beams is traceable to primary standard cross sections.


Assuntos
Algoritmos , Análise de Falha de Equipamento/normas , Modelos Químicos , Nêutrons , Proteção Radiológica/normas , Radiometria/métodos , Radiometria/normas , Simulação por Computador , Análise de Falha de Equipamento/métodos , Alemanha , Internacionalidade , Doses de Radiação , Proteção Radiológica/métodos , Radioisótopos/análise , Padrões de Referência , Espalhamento de Radiação
9.
Ann Chir ; 127(4): 257-61, 2002 Apr.
Artigo em Francês | MEDLINE | ID: mdl-11980297

RESUMO

OBJECTIVE: To evaluate prospectively the laparoscopic surgery for giant hiatal hernias treated by fundoplication and hiatal prosthesis. PATIENTS AND METHODS: Ten patients were included in this study. Surgical technic included the dissection of oesophageal hiatus, the sac excision and the dissection of the abdominal oesophagus to obtain a physiological length. The decision criterion for a prosthesis was the hiatus oesophagus diameter of 5 cm or more. The crura were closed and the hiatus was reinforce by a prosthesis of 15 x 15 cm. All patients underwent a fundoplication whether partial or complete. RESULTS: Eight patients had a type III hernia, and 2 had a type II. The mean size for the hiatus was 6.5 cm (5.5-8). Eight patients underwent a total fundoplicature and 2 a partial one. The prosthesis was made of polypropylene in 5 cases. Average operating time was 182 min (78-240). One patient had postoperative morbidity, with gastroplagia which resolved. There was no mortality. Mean hospitalisation duration was 7.7 days (5-12). No one case of recurrence have been noticed after a mean follow-up of 24 months (8-40). CONCLUSION: It appears that the large size hiatal hernia (more than 5 cm) can be treated with good results by using a prosthesis during laparoscopic fundoplication.


Assuntos
Fundoplicatura/métodos , Hérnia Hiatal/cirurgia , Laparoscopia/métodos , Implantação de Prótese , Idoso , Feminino , Hérnia Hiatal/patologia , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Morbidade , Estudos Prospectivos , Recidiva , Telas Cirúrgicas , Resultado do Tratamento
10.
Radiat Prot Dosimetry ; 161(1-4): 78-81, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24298170

RESUMO

Within the framework of the EURADOS Working Group 11, a comparison of passive neutron dosemeters in high-energy neutron fields was organised in 2011. The aim of the exercise was to evaluate the response of poly-allyl-glycol-carbonate neutron dosemeters from various European dosimetry laboratories to high-energy neutron fields. Irradiations were performed at the iThemba LABS facility in South Africa with neutrons having energies up to 66 and 100 MeV.


Assuntos
Nêutrons , Polímeros/química , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Ar , Aeronaves , Calibragem , Carbonatos/química , Radiação Cósmica , Ciclotrons , Europa (Continente) , Humanos , Imagens de Fantasmas , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Contagem de Cintilação , África do Sul , Astronave
11.
J Mal Vasc ; 38(1): 29-42, 2013 Feb.
Artigo em Francês | MEDLINE | ID: mdl-23312609

RESUMO

THE QUALITY STANDARDS OF THE FRENCH SOCIETY OF VASCULAR MEDICINE FOR THE ULTRASONOGRAPHIC ASSESSMENT OF VASCULAR MALFORMATIONS ARE BASED ON THE TWO FOLLOWING REQUIREMENTS: Technical know-how: mastering the use of ultrasound devices and the method of examination. Medical know-how: ability to adapt the methods and scope of the examination to its clinical indication and purpose, and to rationally analyze and interpret its results. AIMS OF THE QUALITY STANDARDS: To describe an optimal method of examination in relation to the clinical question and hypothesis. To achieve consistent practice, methods, glossary, and reporting. To provide good practice reference points, and promote a high-quality process. ITEMS OF THE QUALITY STANDARDS: The three levels of examination; their clinical indications and goals. The reference standard examination (level 2), its variants according to clinical needs. The minimal content of the examination report; the letter to the referring physician (synthesis, conclusion and proposal for further investigation and/or therapeutic management). Commented glossary (anatomy, hemodynamics, semiology). Technical bases. Settings and use of ultrasound devices. Here, we discuss the methods of using ultrasonography for the assessment of peripheral vascular malformations and tumors.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde , Ultrassonografia Doppler/normas , Malformações Vasculares/diagnóstico por imagem , Neoplasias Vasculares/diagnóstico por imagem , Braço/irrigação sanguínea , Artérias/diagnóstico por imagem , Hemangioma/diagnóstico por imagem , Humanos , Perna (Membro)/irrigação sanguínea , Linfangioma/diagnóstico por imagem , Exame Físico/métodos , Exame Físico/normas , Ultrassonografia Doppler/instrumentação , Ultrassonografia Doppler/métodos , Ultrassonografia Doppler em Cores/métodos , Ultrassonografia Doppler em Cores/normas , Ultrassonografia Doppler de Pulso/métodos , Ultrassonografia Doppler de Pulso/normas , Ultrassonografia de Intervenção/normas , Malformações Vasculares/classificação , Veias/diagnóstico por imagem , Trombose Venosa/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS