Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(7)2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-37050652

RESUMO

Surface brachytherapy (BT) lacks standard quality assurance (QA) protocols. Commercially available treatment planning systems (TPSs) are based on a dose calculation formalism that assumes the patient is made of water, resulting in potential deviations between planned and delivered doses. Here, a method for treatment plan verification for skin surface BT is reported. Chips of thermoluminescent dosimeters (TLDs) were used for dose point measurements. High-dose-rate treatments were simulated and delivered through a custom-flap applicator provided with four fixed catheters to guide the Iridium-192 (Ir-192) source by way of a remote afterloading system. A flat water-equivalent phantom was used to simulate patient skin. Elekta TPS Oncentra Brachy was used for planning. TLDs were calibrated to Ir-192 through an indirect method of linear interpolation between calibration factors (CFs) measured for 250 kV X-rays, Cesium-137, and Cobalt-60. Subsequently, plans were designed and delivered to test the reproducibility of the irradiation set-up and to make comparisons between planned and delivered dose. The obtained CF for Ir-192 was (4.96 ± 0.25) µC/Gy. Deviations between measured and TPS calculated doses for multi-catheter treatment configuration ranged from -8.4% to 13.3% with an average of 0.6%. TLDs could be included in clinical practice for QA in skin BT with a customized flap applicator.


Assuntos
Braquiterapia , Humanos , Braquiterapia/métodos , Reprodutibilidade dos Testes , Radioisótopos de Irídio/uso terapêutico , Dosagem Radioterapêutica , Dosimetria Termoluminescente , Água , Radiometria
2.
Front Oncol ; 13: 1270498, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38023175

RESUMO

Simple summary: Stereotactic body radiotherapy (SBRT) of 35-36.25 Gy in five fractions with the CyberKnife System yields excellent control with low toxicity in low-intermediate-risk prostate cancer patients. We found no differences in biochemical control and overall survival in relation to dose. There were no significant differences in toxicity or quality of life between the two groups. Aims: Stereotactic body radiotherapy (SBRT) is an emerging therapeutic approach for low- and intermediate-risk prostate cancer. We present retrospective data on biochemical control, toxicity, and quality of life of CyPro Trial. Materials and methods: A total of 122 patients with low- and intermediate-risk prostate cancer were treated with the CyberKnife System at a dose of 35 Gy or 36.25 Gy in five fractions. Biochemical failure (BF)/biochemical disease-free survival (bDFS) was defined using the Phoenix method (nadir + 2 ng/ml). Acute/late rectal and urinary toxicities were assessed by the Radiation Therapy Oncology Group (RTOG) toxicity scale. Quality of life (QoL) was assessed by the European Organisation for Research and Treatment of Cancer (EORTC) QLQ C30 and PR25. International Erectile Function Index-5 (IIEF5) and International Prostate Symptom Score (IPSS) questionnaires were administered at baseline, every 3 months after treatment during the first years, and then at 24 months and 36 months. Results: The 1-, 2-, and 5-year DFS rates were 92.9%, 92.9%, and 92.3%, respectively, while the 1-, 2-, and 5-year bDFS rates were 100%, 100%, and 95.7%, respectively. With regard to risk groups or doses, no statistically significant differences were found in terms of DFS or bDFS. Grade 2 urinary toxicity was acute in 10% and delayed in 2% of patients. No Grade 3 acute and late urinary toxicity was observed. Grade 2 rectal toxicity was acute in 8% and late in 1% of patients. No Grade 3-4 acute and late rectal toxicity was observed. Grade 2 acute toxicity appeared higher in the high-dose group (20% in the 36.25-Gy group versus 3% in the 35-Gy group) but was not statistically significant. Conclusion: Our study confirms that SBRT of 35-36.25 Gy in five fractions with the CyberKnife System produces excellent control with low toxicity in patients with low-intermediate-risk prostate cancer. We found no dose-related differences in biochemical control and overall survival. Further confirmation of these results is awaited through the prospective phase of this study, which is still ongoing.

3.
Radiother Oncol ; 166: 15-25, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34774654

RESUMO

Uveal melanoma (UM) represents the most common primary intraocular tumor, and nowadays eye plaque brachytherapy (EPB) is the most frequently used visual acuity preservation treatment option for small to medium sized UMs. The excellent local tumor control (LTC) rate achieved by EPB may be associated with severe complications and adverse events. Several dosimetric and clinical risk factors for the development of EPB-related ocular morbidity can be identified. However, morbidity predictive models specifically developed for EPB are still scarce. PRISMA methodology was used for the present systematic review of articles indexed in PubMed in the last sixteen years on EPB treatment of UM which aims at determining the major factors affecting local tumor control and ocular morbidities. To our knowledge, for the first time in EPB field, local tumor control probability (TCP) and normal tissue complication probability (NTCP) modelling on pooled clinical outcomes were performed. The analyzed literature (103 studies including 21,263 UM patients) pointed out that Ru-106 EPB provided high local control outcomes while minimizing radiation induced complications. The use of treatment planning systems (TPS) was the most influencing factor for EPB outcomes such as metastasis occurrence, enucleation, and disease specific survival, irrespective of radioactive implant type. TCP and NTCP parameters were successfully extracted for 5-year LTC, cataract and optic neuropathy. In future studies, more consistent recordings of ocular morbidities along with accurate estimation of doses through routine use of TPS are needed to expand and improve the robustness of toxicity risk prediction in EPB.


Assuntos
Braquiterapia , Melanoma , Lesões por Radiação , Neoplasias Uveais , Braquiterapia/efeitos adversos , Braquiterapia/métodos , Humanos , Lesões por Radiação/etiologia , Dosagem Radioterapêutica , Estudos Retrospectivos , Neoplasias Uveais/radioterapia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa