Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Prosthet Dent ; 126(1): 119-127, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32636073

RESUMO

STATEMENT OF PROBLEM: Data comparing the fatigue performance of adhesively luted glass or polycrystalline ceramic systems for computer-aided design and computer-aided manufacturing (CAD-CAM) are scarce. PURPOSE: The purpose of this in vitro study was to evaluate and compare the fatigue performance of monolithic crowns manufactured from glass or polycrystalline CAD-CAM ceramic systems adhesively luted to a dentin analog. MATERIALS AND METHODS: Fifty-four pairs of standardized preparations of dentin analog (NEMA Grade G10) and simplified ceramic crowns of 1.5-mm thickness were obtained with 3 ceramic materials: lithium disilicate (LD) glass-ceramic (IPS e.max CAD); zirconia-reinforced lithium silicate (ZLS) glass-ceramic (Vita Suprinity); and translucent yttrium fully stabilized polycrystalline zirconia (Trans YZ) (Prettau Anterior). The simplified crowns (n=15) were adhesively cemented onto the preparations and subjected to step-stress fatigue test (initial load of 400 N, 20 Hz, 10 000 cycles, followed by 100-N increment steps until failure). Collected data (fatigue failure load [FFL] and cycles for failure [CFF]) were submitted to survival analysis with the Kaplan-Meier and Mantel-Cox post hoc tests (α=.05) and to Weibull analysis (Weibull modulus and its respective 95% confidence interval). Failed crowns were submitted to fractography analysis. The surface characteristics of the internal surface (roughness, fractal dimension) of additional crowns were accessed, and the occlusal cement thickness obtained in each luted system was measured. RESULTS: Trans YZ crowns presented the highest values of FFL, CFF, and survival rates, followed by ZLS and LD (mean FFL: 1740 N>1187 N>987 N; mean CFF: 149 000>92 613>73 667). Weibull modulus and cement thickness were similar for all tested materials. LD presented the roughest internal surface, followed by ZLS (mean Ra: 226 nm>169 nm>93 nm). The LD and ZLS internal surfaces also showed higher fractal dimension, pointing to a more complex surface topography (mean fractal dimension: 2.242=2.238>2.147). CONCLUSIONS: CAD-CAM monolithic crowns of Trans YZ show the best fatigue performance. In addition, ZLS crowns also showed better performance than LD crowns.


Assuntos
Cerâmica , Porcelana Dentária , Desenho Assistido por Computador , Coroas , Falha de Restauração Dentária , Análise do Estresse Dentário , Teste de Materiais , Propriedades de Superfície
2.
Artigo em Inglês | MEDLINE | ID: mdl-36383889

RESUMO

In this study, B. cereus was detected in dialysis fluids within international parameters (ultrapure - maximum limit of 0.1 CFU/mL for heterotrophic bacteria count) by analyzing the pellet obtained through the centrifugation method. We also investigated the ability of the B. cereus isolate to form a biofilm at different temperatures, the production of virulence factors, and the susceptibility to commercial antimicrobial agents. This study demonstrated a high ability of B. cereus to persist in the hemodialysis system, which can be explained by its broad ability to produce a biofilm at 25 °C, its relevant production of virulence factors, such as ß-hemolysin, lecithinase and cereulide, and its important resistance pattern to antimicrobial drugs. In conclusion, these new findings expand the understanding that this microorganism should not be neglected and new methods for tracking it should be considered.


Assuntos
Bacillus cereus , Microbiologia de Alimentos , Contaminação de Alimentos , Diálise Renal , Fatores de Virulência
3.
J Mech Behav Biomed Mater ; 124: 104792, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34488172

RESUMO

This study evaluated the influence of surface treatments of resin composite substrate on the fatigue behavior of adhesively cemented lithium disilicate glass-ceramic simplified restorations. CAD/CAM lithium disilicate ceramic blocks were shaped into discs (N = 60, Ø = 10 mm; thickness = 1.0 mm). Resin composite discs (N = 60, Ø = 10 mm, thickness = 2 mm) were allocated into four groups considering the "surface treatment" factor: Ctrl - no surface treatment; Bur - grinding with coarse diamond bur (#3101G, KG Sorensen); PA - etching with 37% phosphoric acid (15 s); AA - air abrasion with alumina particles (45 µm, 10 mm distance, 2.8 bars, 10 s). The surface topography, the roughness, the fractal dimension (estimated by the box-counting method) and the contact angle analyses were performed after the surface treatments. The lithium disilicate discs were etched (5% hydrofluoric acid, 20 s), silanized and adhesively cemented (Multilink N, Ivoclar Vivadent) on the resin composite discs. The samples (bonded restoration set) were subjected to a step-stress fatigue test at 20 Hz, 10,000 cycles/step with a step-size of 100 N applied on the ceramic surface, having ceramic up and resin composite down. Fractographic analysis was performed. The fatigue data (Fatigue Failure Load - FFL; and Cycles for Failure - CFF) were analyzed by Kaplan Meier with Mantel-Cox log-rank post-hoc tests (α = 0.05). No statistical difference for fatigue performance could be found among the groups (FFL means: 820-867 N; CFF means: 53,195-61,090 cycles). The bur group showed higher surface roughness and contact angle values. The PA group has the highest average fractal dimension. Therefore, the resin composite surface treatment induces topographical changes, however, it has no effect on the fatigue behavior of lithium disilicate restorations.


Assuntos
Cerâmica , Porcelana Dentária , Análise do Estresse Dentário , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície , Suporte de Carga
4.
J Adhes Dent ; 23(2): 133-143, 2021 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-33825427

RESUMO

PURPOSE: To evaluate the effect of different etching times of a self-etching ceramic primer on the microshear bond strength (µSBS) and topographic surface pattern of a lithium-disilicate glass-ceramic. MATERIALS AND METHODS: Ceramic slices were subjected to an in-lab simulation of CAD/CAM milling and randomly allocated to 10 groups (n = 35) considering two factors: "surface treatment" in 5 levels - one control group (5% hydrofluoric acid + silane application [HF5+SIL]), and 4 experimental groups using ceramic etching/primer (Monobond Etch & Prime, E&P) with different passive application times (40 s, 2 min, 5 min, or 10 min); and "aging" factor in 2 levels - short-term (after 24 h), or long-term (storage for 180 days + 12,000 thermal cycles). Composite cement cylinders were built and µSBS tests were run in a universal testing machine. The failure patterns were categorized, and complementary analyses with SEM and Atomic Force Microscopy (AFM) were performed. RESULTS: The groups showed statistically similar bond strengths in the short term (range 22.4 to 25.1 MPa). However, only the E&P 20s+40s (19.3 MPa) and E&P 20s+5min (21.5 MPa) groups maintained stable bond strength in the long term, and HF5+SIL (17.1 MPa) presented statistically significantly lower values than did E&P 20s+5min. The failure pattern was predominantly adhesive. The increased application time of the ceramic primer promoted greater dissolution of the glass matrix; thus, the E&P 20s+10min group presented the most complex surface characteristics in the fractal dimension analysis. CONCLUSION: The self-etching ceramic primer can be used as an alternative to classical conditioning with HF plus silane, promoting stable bond strength for etching times of 40 s or 5 min of passive application.


Assuntos
Colagem Dentária , Lítio , Cerâmica , Porcelana Dentária , Ácido Fluorídrico , Teste de Materiais , Cimentos de Resina , Silanos , Propriedades de Superfície
5.
J Mech Behav Biomed Mater ; 110: 103962, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32957253

RESUMO

This study evaluated the distinct conditioning effect of the intaglio surface of bonded fully-stabilized zirconia (FSZ) simplified restorations on the mechanical fatigue behavior of the set prior to and after aging. Ceramic disc shaped specimens (Ø= 10 mm and 1 mm thick) were randomly allocated into 14 groups considering: "surface treatments" (Ctrl: no-treatment; PM: universal primer; GLZ: low-fusing porcelain glaze; SNF: 5 nm SiO2 nanofilm deposition; AlOx: air-abrasion with aluminum oxide; SiC: air-abrasion with silica-coated aluminum oxide; 7%Si: air-abrasion with 7% silica-coated aluminum oxide); and "aging" (baseline: 24 h at 37 °C in water; or aged: 90 days at 37 °C in water + 12,000 thermal cycles). The discs were treated, luted with resin cement onto the dentin analog, subjected to aging or not, and then tested under a step-stress fatigue test at 20 Hz, 10,000 cycles/step, step-size of 100N starting at 200N, and proceeding until failure detection. Fractographic, topographic, surface roughness, contact angle, and atomic force microscopy analyzes were performed. The surface treatments at baseline led to statistically similar fatigue failure loads (953N-1313N), except for GLZ (1313N), which was significantly higher than 7%Si (953 N). Meanwhile, Ctrl had 40% pre-test failures (debonding) after aging, and therefore the worst fatigue performance (notable decrease in fatigue results), while all the other groups presented superior and statistically similar fatigue behavior (973-1271N). In fact, when considering baseline Vs aging conditions, stable fatigue results could only be noted when using surface treatments. In conclusion, internal surface treatments of FSZ ceramic restorations are mandatory for fatigue behavior stability after aging the restorative set, while non-treatment induced unstable results.


Assuntos
Colagem Dentária , Dióxido de Silício , Análise do Estresse Dentário , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície , Zircônio
6.
Dent Mater ; 34(8): 1134-1143, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29789162

RESUMO

OBJECTIVES: To evaluate the effect of different glass-ceramic surface treatments and aging on the fatigue failure load of a lithium disilicate glass-ceramic adhesively cemented to a dentin analogue material. METHODS: One hundred and twenty (120) disc-shaped lithium disilicate specimens (Ø=10mm, thickness=1.5mm) were produced and randomly allocated (n=20) into 6 groups, considering 2 study factors: "surface treatment" in 3 levels (SIL-silane application only; HF5+SIL-5% hydrofluoric acid etching and silane application; ME&P-etching with an one-step ceramic primer), and "storage" in 2 levels (baseline-storage for 7 days; aging-storage for 90 days+12,000 thermal cycles). Ceramic discs were adhesively cemented to discs of a dentin analogue material (Ø=10mm, thickness=2.0mm) following the manufacturers' instructions. The fatigue failure load was determined by the staircase approach (250,000 cycles; 20Hz; initial load=1050N [∼70% of mean load-to-failure]; step size=52.5N [5% of initial load]). Micro-morphologic, fractographic, and atomic force microscope analysis were also performed. Fatigue failure load data were evaluated by one-way ANOVA, Bonferroni and t-tests for independent samples. RESULTS: HF5+SIL presented higher fatigue failure load in both conditions (baseline and aging); ME&P presented intermediary mean values, while the SIL group presented the worst performance. All groups had a statistically significant decrease in the fatigue performance after aging. SIGNIFICANCE: Hydrofluoric acid followed by silane application showed the best fatigue performance for an adhesively-cemented lithium disilicate ceramic. Aging negatively influenced the fatigue performance for all tested groups.


Assuntos
Condicionamento Ácido do Dente , Cerâmica/química , Porcelana Dentária/química , Difosfatos/química , Etanol/química , Metacrilatos/química , Desenho Assistido por Computador , Análise do Estresse Dentário , Teste de Materiais , Microscopia de Força Atômica , Cimentos de Resina , Silanos/química , Propriedades de Superfície
7.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1406864

RESUMO

ABSTRACT In this study, B. cereus was detected in dialysis fluids within international parameters (ultrapure - maximum limit of 0.1 CFU/mL for heterotrophic bacteria count) by analyzing the pellet obtained through the centrifugation method. We also investigated the ability of the B. cereus isolate to form a biofilm at different temperatures, the production of virulence factors, and the susceptibility to commercial antimicrobial agents. This study demonstrated a high ability of B. cereus to persist in the hemodialysis system, which can be explained by its broad ability to produce a biofilm at 25 °C, its relevant production of virulence factors, such as β-hemolysin, lecithinase and cereulide, and its important resistance pattern to antimicrobial drugs. In conclusion, these new findings expand the understanding that this microorganism should not be neglected and new methods for tracking it should be considered.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa