Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Ann Thorac Surg ; 114(6): 2270-2279, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-34890574

RESUMO

BACKGROUND: Open heart surgeries for coronary arterial bypass graft and valve replacements are performed on 400,000 Americans each year. Unexplained hypotension during recovery causes morbidity and mortality through cerebral, kidney, and coronary hypoperfusion. An early detection method that distinguishes between hypovolemia and decreased myocardial function before onset of hypotension is desirable. We hypothesized that admittance measured from a modified pericardial drain can detect changes in left ventricular end-systolic, end-diastolic, and stroke volumes. METHODS: Admittance was measured from 2 modified pericardial drains placed in 7 adult female dogs using an open chest preparation, each with 8 electrodes. The resistive and capacitive components of the measured admittance signal were used to distinguish blood and muscle components. Admittance measurements were taken from 12 electrode configurations in each experiment. Left ventricular preload was reduced by inferior vena cava occlusion. Physiologic response to vena cava occlusion was measured by aortic pressure, aortic flow, left ventricle diameter, left ventricular wall thickness, and electrocardiogram. RESULTS: Admittance successfully detected a drop in left ventricular end-diastolic volume (P < .001), end-systolic volume (P < .001), and stroke volume (P < .001). Measured left ventricular muscle resistance correlated with crystal-derived left ventricular wall thickness (R2 = 0.96), validating the method's ability to distinguish blood from muscle components. CONCLUSIONS: Admittance measured from chest tubes can detect changes in left ventricular end-systolic, end-diastolic, and stroke volumes and may therefore have diagnostic value for unexplained hypotension.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Hipotensão , Feminino , Cães , Animais , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Volume Sistólico/fisiologia , Modelos Animais , Função Ventricular Esquerda/fisiologia
2.
Intensive Care Med Exp ; 9(1): 54, 2021 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-34657982

RESUMO

BACKGROUND: The COVID-19 pandemic has caused a global mechanical ventilator shortage for treatment of severe acute respiratory failure. Development of novel breathing devices has been proposed as a low cost, rapid solution when full-featured ventilators are unavailable. Here we report the design, bench testing and preclinical results for an 'Automated Bag Breathing Unit' (ABBU). Output parameters were validated with mechanical test lungs followed by animal model testing. RESULTS: The ABBU design uses a programmable motor-driven wheel assembled for adult resuscitation bag-valve compression. ABBU can control tidal volume (200-800 ml), respiratory rate (10-40 bpm), inspiratory time (0.5-1.5 s), assist pressure sensing (- 1 to - 20 cm H2O), manual PEEP valve (0-20 cm H2O). All set values are displayed on an LCD screen. Bench testing with lung simulators (Michigan 1600, SmartLung 2000) yielded consistent tidal volume delivery at compliances of 20, 40 and 70 (mL/cm H2O). The delivered fraction of inspired oxygen (FiO2) decreased with increasing minute ventilation (VE), from 98 to 47% when VE was increased from 4 to 16 L/min using a fixed oxygen flow source of 5 L/min. ABBU was tested in Berkshire pigs (n = 6, weight of 50.8 ± 2.6 kg) utilizing normal lung model and saline lavage induced lung injury. Arterial blood gases were measured following changes in tidal volume (200-800 ml), respiratory rate (10-40 bpm), and PEEP (5-20 cm H2O) at baseline and after lung lavage. Physiological levels of PaCO2 (≤ 40 mm Hg [5.3 kPa]) were achieved in all animals at baseline and following lavage injury. PaO2 increased in lavage injured lungs in response to incremental PEEP (5-20 cm H2O) (p < 0.01). At fixed low oxygen flow rates (5 L/min), delivered FiO2 decreased with increased VE. CONCLUSIONS: ABBU provides oxygenation and ventilation across a range of parameter settings that may potentially provide a low-cost solution to ventilator shortages. A clinical trial is necessary to establish safety and efficacy in adult patients with diverse etiologies of respiratory failure.

3.
Theranostics ; 9(12): 3555-3564, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31281497

RESUMO

Higher precision surgical devices are needed for tumor resections near critical brain structures. The goal of this study is to demonstrate feasibility of a system capable of precise and bloodless tumor ablation. An image-guided laser surgical system is presented for excision of brain tumors in vivo in a murine xenograft model. The system combines optical coherence tomography (OCT) guidance with surgical lasers for high-precision tumor ablation (Er:YAG) and microcirculation coagulation (Thulium (Tm) fiber laser). Methods: A fluorescent human glioblastoma cell line was injected into mice and allowed to grow four weeks. Craniotomies were performed and tumors were imaged with confocal fluorescence microscopy. The mice were subsequently OCT imaged prior, during and after laser coagulation and/or ablation. The prior OCT images were used to compute three-dimensional tumor margin and angiography images, which guided the coagulation and ablation steps. Histology of the treated regions was then compared to post-treatment OCT images. Results: Tumor sizing based on OCT margin detection matched histology to within experimental error. Although fluorescence microscopy imaging showed the tumors were collocated with OCT imaging, margin assessment using confocal microscopy failed to see the extent of the tumor beyond ~ 250 µm in depth, as verified by OCT and histology. The two-laser approach to surgery utilizing Tm wavelength for coagulation and Er:YAG for ablation yielded bloodless resection of tumor regions with minimal residual damage as seen in histology. Conclusion: Precise and bloodless tumor resection under OCT image guidance is demonstrated in the murine xenograft brain cancer model. Tumor margins and vasculature are accurately made visible without need for exogenous contrast agents.


Assuntos
Neoplasias Encefálicas/cirurgia , Glioblastoma/cirurgia , Terapia a Laser/métodos , Cirurgia Assistida por Computador/métodos , Animais , Neoplasias Encefálicas/diagnóstico por imagem , Modelos Animais de Doenças , Glioblastoma/diagnóstico por imagem , Humanos , Camundongos , Transplante de Neoplasias , Tomografia de Coerência Óptica , Transplante Heterólogo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa