Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Eur J Vasc Endovasc Surg ; 47(1): 53-60, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24183249

RESUMO

OBJECTIVES: The purpose of this in vitro study was to clinically assess the feasibility of a three-dimensional (3D) electromagnetic (EM) navigator, including sensorized catheters and guidewires, to determine any reduction in radiation dose and contrast medium injection. METHODS: The study was performed using a navigator prototype developed at the EndoCAS center. The system includes catheters and guidewires simultaneously tracked with an EM localizer (Aurora, Northern Digital, Waterloo, Canada). Tests were performed on a commercial abdominal aortic aneurysm model. Fifteen operators were asked to cannulate renal arteries using the conventional fluoroscopic guidance and the EM navigator without fluoroscopic support. Each trial was video-recorded and analyzed for timing and success of completing the cannulation task by two blinded and independent observers. Performances were also qualitatively evaluated using the Imperial College Endovascular Cannulation Scoring Tool (IC3ST). Moreover, a questionnaire was administered to participants to evaluate the navigator potentialities. RESULTS: Quantitative analysis results show no significant difference between the fluoroscopic and EM guidance regarding the total procedure time (median 2.36 minutes [interquartile range {IQR} = 1.26-4.7) vs. 2.95 min [IQR = 1.35-5.38], respectively; p = .93); number of total hits with catheter/guidewire tip to vessels wall (median 5.50 [IQR = 2.00-10.00] vs. 3.50 [IQR = 2.50-7.00], respectively; p = .65); and number of attempts at cannulation (median 4.0 [IQR = 2.00-5.00] vs. 4.0 [IQR = 2.00-5.00], respectively; p = .72]. Moreover, there was no significant difference between the IC3ST score obtained using the EM navigator and the traditional method (average 22.37 [STD = 7.95] vs. 21.58 [STD = 6.86]; p = .92). Finally, questionnaire results indicate a general agreement concerning the navigator usefulness, which clearly shows the positions of instruments inside the 3D model of the patient's anatomy. Participants also agreed that the navigator can reduce the amount of contrast media delivered to the patient, as well as fluoroscopy time. CONCLUSIONS: This work provides proof of concept that simultaneous EM navigation of guidewires and catheters is feasible without the use of live fluoroscopic images.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Fenômenos Eletromagnéticos , Radiografia Intervencionista , Artéria Renal/diagnóstico por imagem , Terapia Assistida por Computador , Dispositivos de Acesso Vascular , Aneurisma da Aorta Abdominal/terapia , Aortografia/métodos , Cateterismo Periférico/instrumentação , Cateterismo Periférico/métodos , Competência Clínica , Meios de Contraste , Estudos de Viabilidade , Fluoroscopia , Humanos , Modelos Anatômicos , Modelos Cardiovasculares , Doses de Radiação , Radiografia Intervencionista/métodos , Inquéritos e Questionários , Análise e Desempenho de Tarefas , Terapia Assistida por Computador/instrumentação , Terapia Assistida por Computador/métodos , Fatores de Tempo , Tomografia Computadorizada por Raios X , Gravação em Vídeo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa