Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Sensors (Basel) ; 19(22)2019 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-31752093

RESUMO

Energy-resolving photon-counting detectors (PCDs) separate photons from a polychromatic X-ray source into a number of separate energy bins. This spectral information from PCDs would allow advancements in X-ray imaging, such as improving image contrast, quantitative imaging, and material identification and characterization. However, aspects like detector spectral distortions and scattered photons from the object can impede these advantages if left unaccounted for. Scattered X-ray photons act as noise in an image and reduce image contrast, thereby significantly hindering PCD utility. In this paper, we explore and outline several important characteristics of spectral X-ray scatter with examples of soft-material imaging (such as cancer imaging in mammography or explosives detection in airport security). Our results showed critical spectral signatures of scattered photons that depend on a few adjustable experimental factors. Additionally, energy bins over a large portion of the spectrum exhibit lower scatter-to-primary ratio in comparison to what would be expected when using a conventional energy-integrating detector. These important findings allow flexible choice of scatter-correction methods and energy-bin utilization when using PCDs. Our findings also propel the development of efficient spectral X-ray scatter correction methods for a wide range of PCD-based applications.

2.
Euro Surveill ; 17(12)2012 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-22490309

RESUMO

We report on a case of imported human rabies in Portugal, in July 2011 in a woman who presented initially complaining of back pain, without relating exposure to animal bites. She had travelled from Portugal to Bissau, Guinea-Bissau, in April where she had been bitten by a dog on 1 May. She was diagnosed with rabies on 26 July and died two weeks later in spite of being treated following the Milwaukee protocol.


Assuntos
Mordeduras e Picadas/complicações , Vírus da Raiva/isolamento & purificação , Raiva/diagnóstico , Viagem , Adulto , Animais , Antivirais/uso terapêutico , Dor nas Costas/etiologia , Busca de Comunicante , Doenças do Cão/transmissão , Cães , Feminino , Guiné-Bissau , Humanos , Reação em Cadeia da Polimerase , Portugal , Profilaxia Pós-Exposição , Raiva/tratamento farmacológico , Raiva/mortalidade , Vacina Antirrábica/administração & dosagem , Vírus da Raiva/genética , Saliva/virologia
3.
Case Rep Urol ; 2021: 2184866, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34513109

RESUMO

Suprapubic catheterization (SPC) is considered a safe and effective procedure for long-term bladder decompression. With proper technique and appropriate patient selection, significant complications of SPC are rare. Immediate postoperative septic shock (i.e., within the first 24 hours of surgery) is rarely reported. We report a case of an 83-year-old patient who developed septic shock within one hour of suprapubic catheterization for a chronic hypotonic bladder, highlighting the importance of early recognition of complications from SPC and prompt management to ensure positive outcomes.

4.
SN Compr Clin Med ; 2(9): 1444-1448, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32838196

RESUMO

A novel coronavirus has emerged in late 2019 capable of causing a severe respiratory disease known as COVID-19. Its pathogenesis appears to be the initiation of an immune response and resulting cytokine storm that damages the healthy lung tissue of the host. Some epidemiological studies found bacillus Calmette-Guérin (BCG) vaccine can help to decrease morbidity and mortality of the viral infection. We aim to review and summarize what is known about COVID-19 and the current implications of intravesical BCG with regard to the disease.

6.
J Environ Radioact ; 139: 140-148, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25464050

RESUMO

Terrestrial gamma dose rates show important spatial variations in France. Previous studies resulted in maps of arithmetic means of indoor terrestrial gamma dose rates by "departement" (French district). However, numerous areas could not be characterized due to the lack of data. The aim of our work was to obtain more precise estimates of the spatial variability of indoor terrestrial gamma dose rates in France by using a more recent and complete data base and geostatistics. The study was based on the exploitation of 97,595 measurements results distributed in 17,404 locations covering all of France. Measurements were done by the Institute for Radioprotection and Nuclear Safety (IRSN) using RPL (Radio Photo Luminescent) dosimeters, exposed during several months between years 2011 and 2012 in French dentist surgeries and veterinary clinics. The data used came from dosimeters which were not exposed to anthropic sources. After removing the cosmic rays contribution in order to study only the telluric gamma radiation, it was decided to work with the arithmetic means of the time-series measurements, weighted by the time-exposure of the dosimeters, for each location. The values varied between 13 and 349 nSv/h, with an arithmetic mean of 76 nSv/h. The observed statistical distribution of the gamma dose rates was skewed to the right. Firstly, ordinary kriging was performed in order to predict the gamma dose rate on cells of 1*1 km(2), all over the domain. The second step of the study was to use an auxiliary variable in estimates. The IRSN achieved in 2010 a classification of the French geological formations, characterizing their uranium potential on the bases of geology and local measurement results of rocks uranium content. This information is georeferenced in a map at the scale 1:1,000,000. The geological uranium potential (GUP) was classified in 5 qualitative categories. As telluric gamma rays mostly come from the progenies of the (238)Uranium series present in rocks, this information, which is exhaustive throughout France, could help in estimating the telluric gamma dose rates. Such an approach is possible using multivariate geostatistics and cokriging. Multi-collocated cokriging has been performed on 1*1 km(2) cells over the domain. This model used gamma dose rate measurement results and GUP classes. Our results provide useful information on the variability of the natural terrestrial gamma radiation in France ('natural background') and exposure data for epidemiological studies and risk assessment from low dose chronic exposures.


Assuntos
Raios gama , Monitoramento de Radiação/métodos , França
7.
J Exp Psychol Hum Percept Perform ; 27(3): 633-43, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11424650

RESUMO

In four experiments, the authors examined the extent to which the ground interpretation of an edge may receive a shape description. These experiments used the priming effect that shapes have on perceptual judgments on a subsequent trial. A robust reduction in error rates and reaction times was seen when the figural shape was the same as that on the previous trial. This repetition priming effect may be due to activation of the shape description of the figure that remained from the previous trial. In contrast, no priming by the shape of the ground was seen even when the contrast sign of the figure reversed between trials. Priming for figural shapes occurred at a relatively abstract level because it was robust across reversals of contrast and orientation. These data suggest that the figural interpretation of a shape receives a shape description but that the ground does not.


Assuntos
Atenção , Aprendizagem por Discriminação , Área de Dependência-Independência , Reconhecimento Visual de Modelos , Adulto , Aprendizagem por Associação , Feminino , Humanos , Masculino , Rememoração Mental , Orientação , Psicofísica , Tempo de Reação
8.
Radiat Prot Dosimetry ; 161(1-4): 78-81, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24298170

RESUMO

Within the framework of the EURADOS Working Group 11, a comparison of passive neutron dosemeters in high-energy neutron fields was organised in 2011. The aim of the exercise was to evaluate the response of poly-allyl-glycol-carbonate neutron dosemeters from various European dosimetry laboratories to high-energy neutron fields. Irradiations were performed at the iThemba LABS facility in South Africa with neutrons having energies up to 66 and 100 MeV.


Assuntos
Nêutrons , Polímeros/química , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Ar , Aeronaves , Calibragem , Carbonatos/química , Radiação Cósmica , Ciclotrons , Europa (Continente) , Humanos , Imagens de Fantasmas , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Contagem de Cintilação , África do Sul , Astronave
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa