RESUMO
BACKGROUND: Midurethral slings are the gold standard for treating stress urinary incontinence, but their complications may raise concerns. Complications may differ by the approach used to place them. OBJECTIVE: This study aimed to compare serious complications and reoperations for recurrence after midurethral sling procedures when using the retropubic vs the transobturator route for female stress urinary incontinence. STUDY DESIGN: This analysis was of patients included in the French, multicenter VIGI-MESH register since February 2017 who received a midurethral sling for female stress urinary incontinence either by the retropubic or the transobturator route and excluded patients with single-incision slings. Follow-up continued until October 2021. Serious complications (Clavien-Dindo classification ≥ grade III) attributable to the midurethral sling and reoperations for recurrence were compared using Cox proportional hazard models including any associated surgery (hysterectomy or prolapse) and a frailty term to consider the center effect. Baseline differences were balanced by propensity score weighting. Analyses using the propensity score and Cox models were adjusted for baseline differences, center effect, and associated surgery. RESULTS: A total of 1830 participants received a retropubic sling and 852 received a transobturator sling in 27 French centers that were placed by 167 surgeons. The cumulative 2-year estimate of serious complications was 5.8% (95% confidence interval, 4.8-7.0) in the retropubic group and 2.9% (95% confidence interval, 1.9-4.3) in the transobturator group, that is, after adjustment, half of the retropubic group was affected (adjusted hazard ratio, 0.41; 95% confidence interval, 0.3-0.6). The cumulative 2-year estimate of reoperation for recurrence of stress urinary incontinence was 2.7% (95% confidence interval, 2.0-3.6) in the retropubic group and 2.8% (95% confidence interval, 1.7-4.2) in the transobturator group with risk for revision for recurrence being higher in the transobturator group after adjustment (adjusted hazard ratio, 1.9; 95% confidence interval, 1.2-2.9); this surplus risk disappeared after exclusion of the patients with a previous surgery for stress urinary incontinence. CONCLUSION: The transobturator route for midurethral sling placement is associated with a lower risk for serious complications but a higher risk for surgical reoperation for recurrence than the retropubic route. Despite the large number of surgeons involved, these risks were low. The data are therefore reassuring.
Assuntos
Slings Suburetrais , Incontinência Urinária por Estresse , Feminino , Humanos , Incontinência Urinária por Estresse/cirurgia , Incontinência Urinária por Estresse/etiologia , Slings Suburetrais/efeitos adversos , Telas Cirúrgicas , Procedimentos Cirúrgicos Urológicos/métodos , ReoperaçãoRESUMO
OBJECTIVE: To evaluate the health status and recovery of women after mid-urethral sling (MUS) revision in response to complications. DESIGN: Cross-sectional study using a questionnaire sent to women from a registry. SETTING: Twenty-two French surgical centres. POPULATION: A total of 287 women from the VIGI-MESH registry responded, having undergone MUS revision for complications. METHODS: Our sample of women were compared against a representative set of French women taken from the Eurostat database. Multivariate analysis was performed to identify clinical predictors for successful MUS revision. A qualitative analysis was carried out on free-text comments. MAIN OUTCOME MEASURES: Health status, defined by the Minimum European Health Module, and recovery, assessed by Patient Global Impression of Improvement. RESULTS: The response rate was 76% (287/378), with 49% of the women (141/287, 95% CI 43%-55%) reporting good health status, which was 8 points lower than that expected from the comparator French set (57%, 95% CI 55%-58%). Overall, 53% (147/275, 95% CI 47%-59%) of the women reported feeling much better after MUS revision. Just over one-third (35%, 95/275, 95% CI 29%-40%) of respondents reported poor health with little or no improvement. Multivariate analysis showed that being operated on for pain at revision was associated with worse self-perceived health than being operated on for exposure (OR 0.36, 95% CI 0.14-0.95); women with pre-existing comorbidity reported a poorer health status following MUS revision (OR 0.22, 95% CI 0.13-0.38). CONCLUSIONS: Our results suggest that half of the women recovered good health status after MUS revision, whereas a proportion appeared to be seriously affected by an MUS complication despite the revision.
Assuntos
Nível de Saúde , Sistema de Registros , Reoperação , Slings Suburetrais , Humanos , Feminino , Estudos Transversais , Pessoa de Meia-Idade , Reoperação/estatística & dados numéricos , Inquéritos e Questionários , França , Incontinência Urinária por Estresse/cirurgia , Idoso , Adulto , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Qualidade de VidaRESUMO
BACKGROUND: While intravesical injections of botulinum neurotoxin A (BoNT-A) are currently recommended for patients experiencing refractory neurogenic overactive bladder and/or detrusor overactivity (OAB/DO), it is unclear how much this therapy is effective and sustainable in the long-term in patients with multiple sclerosis (MS). OBJECTIVES: To assess the mid-term continuation rate of BoNT-A injections to treat neurogenic OAB/DO in MS patients and to investigate MS-specific risk factors for discontinuation. METHODS: This retrospective study involved 11 French university hospital centers. All MS patients who received BoNT-A to treat neurogenic OAB/DO between 2008 and 2013 and were subsequently followed up for at least 5 years were eligible. RESULTS: Of the 196 MS patients included, 159 (81.1%) were still under BoNT-A 5 years after the first injection. The combination of the Expanded Disability Status Scale (EDSS < 6 or ⩾ 6) and of the MS type (relapsing-remitting vs progressive) predicted the risk of discontinuation. This risk was 5.5% for patients with no risk factor, whereas patients presenting with one or two risk factors were 3.3 and 5.7 times more likely to discontinue, respectively. CONCLUSION: BoNT-A is a satisfying mid-term neurogenic OAB/DO therapy for most MS patients. Combining EDSS and MS type could help predict BoNT-A discontinuation.
Assuntos
Toxinas Botulínicas Tipo A , Esclerose Múltipla , Fármacos Neuromusculares , Bexiga Urinaria Neurogênica , Bexiga Urinária Hiperativa , Urologia , Humanos , Toxinas Botulínicas Tipo A/efeitos adversos , Bexiga Urinária Hiperativa/etiologia , Bexiga Urinária Hiperativa/complicações , Fármacos Neuromusculares/efeitos adversos , Administração Intravesical , Estudos Retrospectivos , Esclerose Múltipla/complicações , Esclerose Múltipla/induzido quimicamente , Bexiga Urinaria Neurogênica/tratamento farmacológico , Bexiga Urinaria Neurogênica/etiologia , Resultado do TratamentoRESUMO
PURPOSE: Robot-assisted partial nephrectomy (RAPN) reduces morbidity, enabling development of Enhanced Recovery After Surgery (ERAS) and day-case protocols. Additional financial costs limit its integration into clinical practice. We evaluated the medico-economic impact of RAPN using a nurse-led coordinated pathway of care (NLC-RAPN). METHODS: All tumor RAPNs performed in 2017 were prospectively included in nurse-led protocols: NP-RAAC (ERAS) or Ambu-Rein (day case). Clinico-biological and pathological data were prospectively collected within the French Research Network for Kidney Cancer database (NCT03293563). Estimated costs were compared to "average" patients at the national level operated by open partial nephrectomy (OPN) or RAPN, using data from the 2017 French hospital discharge database and the national cost scale. RESULTS: The NLC-RAPN cohort (n = 151) included 27 (18%) outpatients and the average hospital length of stay (LOS) was 2.4 days. In the national control cohorts for OPN (n = 2475) and RAPN (n = 3529), the average LOS were 8.0 and 5.2 days, respectively. The mean incomes per group were 7607 for NLC-RAPN, 9813 for OPN, and 8215 for RAPN. The mean daily cost of stay was 659 for NLC-RAPN, 838 for OPN, and 725 for RAPN. The overall cost for NLC-RAPN was 6594, 8733 for OPN, and 8763 for RAPN. The best operational margin was obtained for day-case NLC-RAPN (1967). CONCLUSION: Combining RAPN with nurse-led coordinated pathways of care led to a shorter hospital stay and reduced costs versus OPN. This may facilitate the economic sustainability of robotic assistance for hospitals where the extra cost is not covered by the healthcare system.
Assuntos
Neoplasias Renais , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Clínicos , Neoplasias Renais/patologia , Nefrectomia/métodos , Papel do Profissional de Enfermagem , Complicações Pós-Operatórias/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Resultado do Tratamento , Estudos ProspectivosRESUMO
PURPOSE: Persistence or recurrence of stress urinary incontinence (prSUI) after artificial urinary sphincter (AUS) implantation may be secondary to non-mechanical failure (NOMECA). It have for long been assumed to result from urethral atrophy. Its existence is now debated. As the pathophysiology of NOMECA is not elucidated, the most appropriate management remains unclear. We aimed to compare the several revision techniques for NOMECA of AUS in men. METHODS: NOMECA was defined as prSUI, with normally functioning device, no erosion, infection or fluid loss. Exclusion criteria were neurogenic SUI, revision or explantation for other causes. From 1991 to 2022, 143 AUS revisions for NOMECA, including 99 cuff DOWNSIZING, 10 cuff repositioning (RELOC), 13 TANDEM-CUFF placement, 18 cuff changing (CHANGE), three increasing balloon pressure (BALLOON-UP), were performed in 10 centers. BALLOON-UP patients weren't included in comparative analysis due to small sample size. All components could be changed during the revision. Patients were also categorized in COMPLETE-CHANGE vs. PARTIAL-CHANGE of the device. RESULTS: The three-months complete continence rate was 70.8% with a significant difference between RELOC and DOWNSIZING groups (p = 0.04). COMPLETE CHANGE was significantly associated with complete continence status at three months in multivariate analysis (83.3% vs. 63.3%, OR = 2.7; CI 95% [1.1-7.1], p = 0.03). Estimated five-year reoperation-free and explantation-free survival were respectively 63.4% and 75.9% (p = 0.16; p = 0.30). Those were significantly longer in COMPLETE-CHANGE vs PARTIAL-CHANGE (82.2% vs. 69.6%, p = 0.03); (71.2% vs. 58.2%, p = 0.047). CONCLUSIONS: AUS revision for prSUI due to NOMECA yields satisfactory outcomes regardless of the technique used. We observed better functional outcomes when repositioning the new cuff. COMPLETE-CHANGE may improve functional outcomes, explantation-free and reoperation-free survivals.
Assuntos
Doenças Uretrais , Incontinência Urinária por Estresse , Esfíncter Urinário Artificial , Humanos , Masculino , Esfíncter Urinário Artificial/efeitos adversos , Incontinência Urinária por Estresse/cirurgia , Incontinência Urinária por Estresse/etiologia , Implantação de Prótese/métodos , Reoperação/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Uretra/cirurgiaRESUMO
PURPOSE: Robot-assisted partial nephrectomy (RAPN) is a difficult procedure with risk of significant perioperative complications. The objective was to evaluate the impact of preoperative planning and intraoperative guidance with 3D model reconstructions on perioperative outcomes of RAPN. METHODS: We conducted a retrospective analysis of all patients who underwent RAPN for kidney tumor by three high-volume expert surgeons from academic centers. Clinical data were collected prospectively after written consent into the French kidney cancer network database UroCCR (CNIL-DR 2013-206; NCT03293563). Our cohort was divided into two groups: 3D-Image guided RAPN group (3D-IGRAPN) and control group. A propensity score according to age, pre-operative renal function and RENAL tumor complexity score was used. Both surgical techniques were compared in terms of perioperative outcomes. RESULTS: The initial study cohort included 230 3D-IGRAPN and 415 control RAPN. Before propensity-score matching, patients in the 3D-IGRAPN group had a larger tumor (4.3 cm vs. 3.5 cm, P < 0.001) and higher RENAL complexity score (9 vs. 8, P < 0.001). Following propensity-score matching, there were 157 patients in both groups. The rate of major complications was lower for patients in the 3D-IGRAPN group (3.8% vs. 9.5%, P = 0.04). The median percentage of eGFR variation recorded at first follow-up was lower in the 3D-IGRAPN group (- 5.6% vs. - 10.5%, P = 0.002). The trifecta achievement rate was higher in the 3D-IGRAPN group (55.7% vs. 45.1%; P = 0.005). CONCLUSION: Three-dimensional kidney reconstructions use for pre-operative planning and intraoperative surgical guidance lowers the risk of complications and improve perioperative clinical outcomes of RAPN.
Assuntos
Neoplasias Renais , Procedimentos Cirúrgicos Robóticos , Humanos , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/métodos , Pontuação de Propensão , Nefrectomia/métodos , Neoplasias Renais/patologia , Resultado do TratamentoRESUMO
INTRODUCTION AND HYPOTHESIS: To assess the effectiveness, safety and risk factors of failure and complications associated with Adjustable Continence Therapy (ACT®) balloons as a treatment for female stress urinary incontinence (SUI). METHODS: In the present multicentric retrospective study, all women implanted with ACT® balloons between 2000 and 2018 were considered eligible. Effectiveness and safety were assessed at 1 year, and risk factors for failure and complications were sought. The effectiveness was categorized into three distinct groups: Success = maximum 1 pad/day and patient's impression of improvement using a numerical rating scale (NRS) ≥ 8/10; Improvement = decrease of daily pad use and NRS ≥ 5/10; Failure = increase or stability of daily pad use or NRS < 5/10. The intra- and postoperative surgical complications were collected. RESULTS: Over the study period, 281 women were included. Among them, 104 (37.0%), 94 (33.5%) and 83 (29.5%) were categorized as success, improvement, and failure, respectively. Intra-, early and late postoperative complications occurred in 13 (4.6%), 35 (12.5%) and 75 (26.7%) women, respectively. Most early surgical complications were minor according to the Dindo-Clavien classification. Of women that presented a late postoperative surgical complication, 64 (22.8%) underwent an explantation performed under local or general anesthesia without associated sequalae. CONCLUSIONS: The short-term effectiveness associated with ACT® balloons, their minimally invasive implantation and the frequent but easily manageable and sequelae-free complications suggest that they should be part of the therapeutic arsenal for female SUI.
Assuntos
Incontinência Urinária por Estresse , Esfíncter Urinário Artificial , Humanos , Feminino , Masculino , Incontinência Urinária por Estresse/cirurgia , Incontinência Urinária por Estresse/etiologia , Resultado do Tratamento , Estudos Retrospectivos , Próteses e Implantes , Fatores de Risco , Esfíncter Urinário Artificial/efeitos adversosRESUMO
PURPOSE: Robotic partial nephrectomy (RPN) is a minimally-invasive technique used to treat renal tumors. A clinical pathway and prospective research protocol (AMBU-REIN) were specifically set up to establish and assess the routine use of day-case RPN. METHODS: The AMBU-REIN study was conducted in the framework of the French research network on kidney cancer UroCCR (NCT03293563). We present our initial experience of patients treated using day-case RPN and released from our hospital on the same day, focusing on patient selection, safety and patient satisfaction using the EVAN-G validated questionnaire. RESULTS: Between September 2016 and September 2019, 429 RPN were performed and 82 patients were consecutively selected for day-case RPN. Patients were managed using transperitoneal RPN with off-clamp tumorectomy for 66/82 cases. Mean tumor size was 2.7 ± 1.2 cm. There were no immediate severe postoperative complications; 7/82 patients were kept under observation overnight and discharged the following day. The follow-up at day 30 indicated postoperative complications, readmissions, and mortality rates of 1.2, 1.2, and 0%, respectively. Next-day patient satisfaction questionnaires indicated that patients were generally highly satisfied, with a mean ± standard deviation global score of 83.6 ± 10.3%. "Attention" was rated the highest overall (mean 94.8 ± 10.5%), while "pain management" scored the lowest (61.2 ± 20.5%). CONCLUSIONS: This prospective case series is the first to demonstrate the safety and feasibility of day-case RPN. For selected patients and through a dedicated, nurse-led clinical pathway, it provided a high level of patient satisfaction. Expected benefits on healthcare cost savings warrant further investigation.
Assuntos
Neoplasias Renais , Procedimentos Cirúrgicos Robóticos , Estudos de Viabilidade , Humanos , Neoplasias Renais/patologia , Neoplasias Renais/cirurgia , Nefrectomia/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/métodos , Resultado do TratamentoRESUMO
PURPOSE: To establish whether the expression of markers of cell differentiation (CK7, CK14, CK20, GATA3), apoptosis (p53), proliferation (Ki67, STAG2) and peri-tumoural lymphocytes (CD3, CD8), provides specific information about urothelial carcinogenesis in neuro-urological patients with bladder cancer (NBC). METHODS: Tissue samples from NBC were retrieved from 15 centres in France and compared to control samples from non neuro-urological patients with bladder cancer (NNBC) and from neuro-urological patients without bladder cancer (NB). The expression of CK7, CK14, CK20, GATA3, p53, Ki67, STAG2, CD3 and CD8 markers was analysed using immunohistochemistry of tissue microarray sections. RESULTS: Overall, tissue samples from 124 patients were included in the study (n = 72 NBC, n = 26 NNBC and n = 26 NB). Muscle invasive bladder cancer (MIBC) was found in 52 NBC patients (72.2%) and squamous cell differentiation in 9 (12.5%). In NBC samples, the expression of CK20 and GATA3 was significantly more frequent in NMIBC compared to MIBC (p = 0.015 and p = 0.004, respectively). CK20 and GATA3 were significantly more expressed in NBC compared to NNBC (p < 0.001 and p = 0.010, respectively). The expression of CK14, Ki67, CD3 and CD8 was significantly more frequent in NBC than in NNBC samples (p = 0.005, p < 0.001, p < 0.001 and p < 0.001, respectively). The expression of CD3 and CD8 was similar in NBC and NB samples. CONCLUSION: In NBC, markers of basal differentiation, proliferation and peri-tumoural lymphocytes were significantly more expressed compared to NNBC controls. These results suggest the aggressiveness of NBC and the role of chronic inflammation in the carcinogenesis of bladder cancer in neuro-urological patients.
Assuntos
Neoplasias da Bexiga Urinária , Urologia , Biomarcadores Tumorais/metabolismo , Carcinogênese , Humanos , Antígeno Ki-67/metabolismo , Proteína Supressora de Tumor p53 , Neoplasias da Bexiga Urinária/metabolismoRESUMO
AIMS: To compare efficacy and safety between neurogenic and non-neurogenic women after adjustable continence therapy (ACT®) balloons implantation to treat stress urinary incontinence (SUI) due to intrinsic sphincter deficiency. METHODS: In the present retrospective multicentric study, all neurogenic and non-neurogenic women implanted with ACT® balloons between 2000 and 2018 were considered for inclusion. Efficacy was compared 1 year after implantation, and women were allocated in three different groups as follows. Success: maximum 1 pad per day and patient's impression of improvement assessed using a numeral rating scale (NRS) ≥8/10. Improvement: decrease of daily pad use and/or NRS ≥5/10. Failure: increase or stability of daily pad use or NRS <5/10. Overall surgical complications and explantations were compared 1 year after implantation. RESULTS: Among the 277 included women, 51 presented with a neurologic underlying disease. Mean age at implantation was 68.5 years. There was no significant difference in efficacy between neurogenic and non-neurogenic women with a success rate of 39.2% and 36.3%, respectively (p = 0.69). Similarly, improvement rate was reported to be 31.4% and 33.6%, in neurogenic and non-neurogenic women, respectively (p = 0.92). The overall surgical complications rate (24% vs. 34.5%, p = 0.15) and the explantation rate (19.6% vs. 28.8%, p = 0.18) were not significantly different. CONCLUSION: ACT balloons may be proposed to treat mixed or SUI in females with ISD. Efficacy and safety profiles appear to be similar in both neurogenic and non-neurogenic patients.
Assuntos
Doenças Uretrais , Incontinência Urinária por Estresse , Esfíncter Urinário Artificial , Feminino , Humanos , Próteses e Implantes/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Doenças Uretrais/complicações , Incontinência Urinária por Estresse/etiologia , Incontinência Urinária por Estresse/cirurgia , Esfíncter Urinário Artificial/efeitos adversosRESUMO
AIMS: To evaluate the impact of an history of radiation therapy on the outcomes of artificial urinary sphincter (AUS) implantation in male patients. METHODS: The charts of all patients who underwent AUS implantation for stress urinary incontinence (SUI) after prostate surgery in thirteen centers between 2004 and 2020 were retrospectively reviewed. We excluded patients with neurogenic SUI. Continence rates and incidence of complications, revision and cuff erosion were evaluated. The outcomes in irradiated men were compared to those of non irradiated men. RESULTS: A total of 1277 patients who had an AUS met the inclusion criteria with a median age of 70 years, of which 437 had an history of prior radiotherapy. There was no difference in comorbidities. In irradiated patients, postoperative social continence, urethral atrophy and infection rates were respectively 75.6%, 2.4% and 9.5% and 76.8%, 5.4%, and 5.8% in nonirradiated men (respectively, p = 0.799, p = 0.128, p = 0.148). There were more urethral erosion in irradiated male patients. After a mean follow up of 36.8 months, the explantation free survival was poorer in irradiated patients (p = 0.001). CONCLUSION: These data suggest that pelvic radiotherapy before AUS adversely affect device survival with and increased greater occurrence of infection-erosion and therefore of explantation.
Assuntos
Incontinência Urinária por Estresse , Esfíncter Urinário Artificial , Idoso , Humanos , Masculino , Implantação de Prótese/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Uretra/cirurgia , Incontinência Urinária por Estresse/etiologia , Incontinência Urinária por Estresse/cirurgia , Esfíncter Urinário Artificial/efeitos adversosRESUMO
OBJECTIVES: To describe the incidental prostate cancer (iPCa) rate and identify predictive factors for PCa progression after holmium laser enucleation of the prostate (HoLEP). METHODS: A retrospective review of all iPCa cases diagnosed after HoLEP procedures between April 2012 and May 2020 was conducted. iPCa was defined as a symptom-free cancer diagnosed after HoLEP in patients without any diagnosis or suspicion of PCa before surgical treatment. PCa progression was suspected by rise in PSA from baseline after HoLEP and confirmed by progressive disease detected on transrectal needle biopsy or by the appearance of metastatic disease. Univariate and multivariate logistic regression were used to identify predictive factors for cancer progression. RESULTS: The iPCa rate in our cohort was 10.7% (n = 134). Among patients with iPCa, 25 (18.6%) progressed with a mean follow-up of 32 months. Regarding predictive factors, post-operative PSA (OR 2.35, p < 0.001) was significantly associated with PCa progression in multivariate analysis. The cutoff value for post-operative PSA was determined at 2 ng/mL. Among iPCa cases, 14 patients (10.4%) had both T1b stage disease and PSA ≥ 2 ng/mL, while 68 (50.7%) had neither of these factors. Univariate logistic regression analysis showed that patients with both factors had the highest risk of progression (OR 49.4; p < 0.001). CONCLUSION: In this study, post-operative PSA above 2 ng/mL was the only independent risk factor for iPCa progression after HoLEP. Patients with post-operative PSA ≥ 2 ng/mL must be considered to be at risk of progression and may require early curative treatment or closer follow-up in the post-operative period, especially when this is associated with T1b stage disease.
Assuntos
Lasers de Estado Sólido , Hiperplasia Prostática , Neoplasias da Próstata , Hólmio , Humanos , Incidência , Lasers de Estado Sólido/efeitos adversos , Masculino , Próstata/patologia , Antígeno Prostático Específico , Hiperplasia Prostática/complicações , Hiperplasia Prostática/patologia , Hiperplasia Prostática/cirurgia , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Resultado do TratamentoRESUMO
PURPOSE: The main objective of this study was to assess the prevalence and risk factors of male artificial urinary sphincter (AUS) mechanical failures and nonmechanical failures. MATERIALS AND METHODS: The charts of all male patients who underwent AUS implantation between 2004 and 2020 in 16 centers were retrospectively reviewed. Patients with neurogenic stress urinary incontinence (SUI) were excluded as well as revisions/explantations due to infections and/or erosions. The causes of revision were divided into mechanical failures (fluid loss or malfunction from any components of the AUS), nonmechanical failures (urethral atrophy, recurrence/persistence of SUI despite normally functioning device) and other (pump malposition, balloon herniation, hematoma, pain). Failure-free survival analysis was performed both for general and specific causes of revision. Predictors of mechanical and nonmechanical failures were determined by Cox proportional hazards model. RESULTS: A total of 1,020 patients met the inclusion criteria. After a median followup of 20 months, the estimated 5-year and 10-year overall revision-free survival was 60% and 40%, respectively. There were 214 AUS revisions: 59 (27.6%) for mechanical failures, 121 (56.5%) for nonmechanical failures and 34 (15.9%) other causes of revision. In multivariable Cox regression analysis, larger cuff size was the only predictor of overall revisions (HR=1.04 [1.01-1.07]; p=0.01) and revision for nonmechanical failure (HR=1.05 [1.02-1.09]; p=0.004). CONCLUSIONS: Half of the male AUS patients underwent device revision within the first 10 years after implantation. Nonmechanical failures are the primary cause of AUS revision in nonneurological men. Larger cuff size appears to be the main determinant of AUS revision risk.
Assuntos
Remoção de Dispositivo/estatística & dados numéricos , Falha de Prótese , Implantação de Prótese/efeitos adversos , Incontinência Urinária/cirurgia , Esfíncter Urinário Artificial/efeitos adversos , Idoso , Seguimentos , Humanos , Masculino , Prevalência , Implantação de Prótese/instrumentação , Estudos Retrospectivos , Medição de Risco/estatística & dados numéricos , Fatores de Risco , Incontinência Urinária/etiologia , Esfíncter Urinário Artificial/estatística & dados numéricosRESUMO
PURPOSE: To assess the outcomes of continent urinary diversion according to the Mitrofanoff principle by robot-assisted laparoscopic surgery in terms of continence, catheterization and repeat surgery. METHODS: All adult patients who underwent procedures for continent urinary diversion via a robot-assisted laparoscopic route between October 2014 and November 2018 were enrolled retrospectively. Abdominal continence and clean intermittent catheterization ability were noted, as well as patient characteristics, details of the technique, intra- and perioperative parameters, and complications. RESULTS: Ten patients were included. Bladder-sphincter disorders were due to neurological causes in nine patients, and one patient had idiopathic bladder sphincter dyssynergia. A continent catheterizable channel was created using the appendix in six cases and the ileum in four cases. The median operative duration was 245 min (IQR 228-370). Two patients had a Clavien 3 complication requiring laparoscopy to separately drain a haematoma and a pelvic abscess. The median follow-up was 21 months (IQR 17-27). Abdominal continence without further intervention was obtained in 6/10 patients (60%). Two patients needed an open revision of the continent urinary diversion, one required injection of Deflux® and one an intradetrusorian injection of botulinum toxin type A (Botox®). Further surgery was needed for two patients to improve urethral continence. At the end of follow-up, all patients were continent and clean intermittent catheterization was possible. CONCLUSION: Continent urinary diversion performed according to the Mitrofanoff principle is possible via a robot-assisted laparoscopic route and yields good outcomes on abdominal continence in the short term in patients with clean intermittent catheterization ability.
Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Doenças da Bexiga Urinária/cirurgia , Derivação Urinária/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos RetrospectivosRESUMO
PURPOSE: To compare transcorporal vs bulbar artificial urinary sphincter (AUS) implantation in men with fragile urethra and to investigate the risk factors of AUS explantation in this population. METHODS: The charts of all male patients who had an AUS implantation between 2004 and 2020 in 16 centers were reviewed retrospectively. The primary endpoint was device explantation-free survival. Only patients with a fragile urethra were included in the present analysis. Fragile urethra was defined as a urethra carrying a high risk of cuff erosion because of prior radiotherapy and/or history of AUS explantation and/or history of urethral stricture surgery. The patients were divided in two groups according to the implantation site: bulbar vs transcorporal. RESULTS: 464 patients were included for analysis. 88 patients underwent a transcorporal AUS implantation and 376 underwent a bulbar AUS implantation. Explantation-free survival was similar in both groups (estimated 5-year explantation free survival rates 55.3% vs. 58.4%; p=0.98). In the subgroup of patients with a history of previous AUS explantation, transcorporal approach tended to bring longer explantation-free survival (2-year explantation-free survival: 61.9% vs. 58.2%; p=0.096). In multivariate analysis, the only risk factor of shorter explantation-free survival was the history of previous AUS explantation (HR=2.65; p=0.01). CONCLUSIONS: Transcorporal AUS implantation was not associated with longer explantation-free survival. History of previous AUS explantation was the only risk factor associated with shorter explantation-free survival and this subgroup of patients may be the only one to draw benefits of transcorporal AUS implantation.
Assuntos
Implantação de Prótese/métodos , Esfíncter Urinário Artificial , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Fatores de RiscoRESUMO
PURPOSE OF REVIEW: The aim of the present manuscript was to provide an overview on the current state of robotic artificial urinary sphincter (AUS) implantation in male and female patients. RECENT FINDINGS: Over the past few years, several series have been reported, with promising outcomes for the most part. This has contributed to expand the use of bladder neck AUS, especially in female patients, which was, until then, hampered by its perioperative morbidity. SUMMARY: Robotic AUS has been developed to overcome the technical challenge of bladder neck implantation in female patients and in specific male subgroups, especially self-catheterizing neurological patients. All the series of robotic AUS implantation published in the past few years reported much lower rates of cuff erosion and AUS explantation than the historical open cohorts suggesting that the robotic approach might become the standard for female AUS implantation. This less morbid approach along with technological improvement of the AUS device may contribute to make it a more popular option in the treatment of female stress urinary incontinence due to intrinsic sphincter deficiency. There are much less data available on robotic bladder neck AUS implantation in male patients.
Assuntos
Robótica , Incontinência Urinária por Estresse , Esfíncter Urinário Artificial , Feminino , Humanos , Masculino , Implantação de Prótese/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Incontinência Urinária por Estresse/cirurgia , Procedimentos Cirúrgicos UrológicosRESUMO
AIMS: To report the long-term functional outcomes of artificial urinary sphincter (AUS) implantation in female patients with spinal dysraphism and stress urinary incontinence (SUI) related to intrinsic sphincter deficiency (ISD). METHODS: The charts of all spina bifida female patients with SUI due to ISD who underwent AUS (AMS 800) implantation between 2005 and 2019 at three academic departments of urology were retrospectively reviewed. Reoperation was defined as either revision or explantation of the AUS device. Reoperation-free survival of the AUS device was estimated using the Kaplan-Meier method. Continence status as per patients' subjective assessment was categorized as follows: complete continence (no pads), improved continence, unchanged SUI or worsened SUI. RESULTS: Twenty-three patients were included, 69.6% were self-catheterizing. The median follow-up was 14 years. Median time to first reoperation was 10 years. Survival rates without reoperation were 85.9%, 41.8%, 34.6%, and 20.9% at 5, 10, 15, 20 years, respectively. Survival rates without AUS explantation were 90.7%, 66.3%, 55.2%, and 41.4% at 5, 10, 15, 20 years, respectively. None of the patients who underwent device explantation had a new AUS implanted. The only predictive factor of reoperation-free survival was the type of spinal dysraphism (hazards ratio = 3.60 for closed vs. open dysraphism; p = .04). At last follow-up, 17 of the 23 patients were fully continent (73.9%). CONCLUSION: AUS in female patients with spina bifida may be associated with satisfactory long-term functional outcomes and a high reoperation rate. The median time to first reoperation was similar to what is reported in the male AUS literature (10 years).
Assuntos
Disrafismo Espinal/complicações , Disrafismo Espinal/terapia , Incontinência Urinária por Estresse/cirurgia , Esfíncter Urinário Artificial/normas , Adulto , Feminino , Humanos , Estudos Retrospectivos , Análise de Sobrevida , Resultado do Tratamento , Incontinência Urinária por Estresse/mortalidadeRESUMO
PURPOSE OF REVIEW: The aim of the present report was to review the recent evidences regarding the use of artificial urinary sphincter (AUS) in adult females. RECENT FINDINGS: While the excellent functional outcomes of AUS in female patients with stress urinary incontinence (SUI) due to intrinsic sphincter deficiency (ISD) have been reported for decades, its use has remained confidential in most countries likely due to its challenging implantation and inherent morbidity. Over the past few years, laparoscopic and, more recently, robotic techniques of AUS implantation in female patients have been described with promising perioperative outcomes. As a result, the use of AUS has increased in several countries. The indications are mostly recurrent or persistent SUI after previous anti-incontinence procedures and neurogenic SUI. Owing to its unique potential to restore continence while maintaining low outlet resistance during the voiding phase, AUS may be of special interest in female patients with detrusor underactivity. High level of evidence data from trials which are underway, along with developments in robotic surgery and technological refinements of the device, may well, almost 50 years after its introduction, give to the AUS its momentum as a major contributor in the female SUI armamentarium. While the use of AUS in female patients has been restricted to some countries and a few high-volume centers, it has started spreading again over the past few years, thanks to the rise of minimally invasive approaches which facilitate its implantation, and this is yielding promising outcomes.
Assuntos
Implantação de Prótese , Incontinência Urinária por Estresse/cirurgia , Esfíncter Urinário Artificial , Adulto , Feminino , Humanos , Laparoscopia , Implantação de Prótese/métodos , Procedimentos Cirúrgicos Robóticos , Resultado do Tratamento , Esfíncter Urinário Artificial/efeitos adversosRESUMO
AIMS: To perform a systematic review of studies reporting the outcomes of AMS-800 artificial urinary sphincter (AUS) implantation in female patients with stress urinary incontinence (SUI) resulting from intrinsic sphincter deficiency (ISD). METHODS: A systematic literature search of the Medline and Embase databases was performed in June 2018 in accordance with the PRISMA statement. No time limit was used. The protocol was registered in PROSPERO (CRD42018099612). Study selection and data extraction were performed by two independent reviewers. RESULTS: Of 886 records screened, 17 were included. All were retrospective or prospective non-comparative case series. One study reported on vaginal AUS implantation, 11 on open AUS implantation, two on laparoscopic AUS implantation, two on robot-assisted AUS implantation and one compared open and robot-assisted implantations. The vast majority of patients had undergone at least one anti-incontinence surgical procedure prior to AUS implantation (69.1-100%). The intraoperative bladder neck injury rates ranged from 0% to 43.8% and the intraoperative vaginal injury rates ranged from 0 to 25%. After mean follow-up periods ranging from 5 to 204 months, the complete continence rates ranged from 61.1% to 100%. The rates of explantation, erosion and mechanical failure varied from 0% to 45.3%, 0% to 22.2% and 0% to 44.1%, respectively. CONCLUSIONS: AMS-800 AUS can provide excellent functional outcomes in female patients with SUI resulting from ISD but at the cost of a relatively high morbidity. High level of evidence studies are needed to help better define the role of AUS in the female SUI armamentarium.
Assuntos
Incontinência Urinária por Estresse/cirurgia , Esfíncter Urinário Artificial , Procedimentos Cirúrgicos Urológicos/métodos , Feminino , HumanosRESUMO
PURPOSE: The aim of the current study was to determine the outcomes of botulinum toxin A intradetrusor injections in adult patients with spina bifida. MATERIALS AND METHODS: All patients with spinal dysraphism who underwent intradetrusor injections of botulinum toxin A from 2002 to 2016 at a total of 14 centers were retrospectively included in analysis. The primary end point was the global success of injections, defined subjectively as the combination of urgency, urinary incontinence and detrusor overactivity/low bladder compliance resolution. Univariate and multivariate analysis was performed to seek predictors of global success. RESULTS: A total of 125 patients were included in study. The global success rate of the first injection was 62.3% with resolution of urinary incontinence in 73.5% of patients. All urodynamic parameters had improved significantly by 6 to 8 weeks compared to baseline, including maximum detrusor pressure (-12 cm H2O, p <0.001), maximum cystometric capacity (86.6 ml, p <0.001) and compliance (8.9 ml/cm H2O, p = 0.002). A total of 20 complications (3.6%) were recorded for the 561 intradetrusor botulinum toxin A injections, including 3 muscular weakness complications. The global success rate of the first injection was significantly lower in patients with poor compliance (34.4% vs 86.9%, OR 0.08, p <0.001). On multivariate analysis poor compliance was associated with a lower global success rate (OR 0.13, p <0.001). Female gender (OR 3.53, p = 0.01) and patient age (OR 39.9, p <0.001) were predictors of global success. CONCLUSIONS: Intradetrusor botulinum toxin A injections were effective in adult patients with spina bifida who had detrusor overactivity. In contrast, effectiveness was much lower in adult patients with spina bifida who had poor bladder compliance. The other predictors of global success were female gender and older age.