Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 93(2): 181-188, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30280482

RESUMO

OBJECTIVES: This prospective, observational all-comers registry assessed the safety and efficacy of a Drug Coated Balloon-only strategy (DCB-only) in patients with coronary lesions. BACKGROUND: Data regarding the performance of a DCB-only approach, especially in patients with previously untreated de-novo coronary artery disease (CAD), are still limited. METHODS: This study was conducted as an international, multicenter registry primarily enrolling patients with de-novo CAD. However, it was also possible to include patients with in-stent restenosis (ISR). The primary endpoint was the rate of clinically driven target lesion revascularization (TLR) after 9 months. RESULTS: A total of 1,025 patients with a mean age of 64.0 ± 11.2 years were enrolled. The majority of treated lesions were de-novo (66.9%), followed by drug-eluting-stent ISR (DES-ISR; 22.6%) and bare-metal-stent ISR (BMS-ISR; 10.5%). The TLR rate was lower in the de-novo group (2.3%) when compared to BMS- (2.9%) and DES-ISR (5.8%) (P = 0.049). Regarding MACE, there was a trend toward fewer events in the de-novo group (5.6%) than in the BMS- (7.8%) and DES-ISR cohort (9.6%) (P = 0.131). Subgroup analyses revealed that lesion type (95% CI 1.127-6.587); P = 0.026) and additional stent implantation (95% CI 0.054-0.464; P = 0.001) were associated with higher TLR rates. CONCLUSIONS: Our results show that DCB-only angioplasty of de-novo coronary lesions is associated with low MACE and TLR rates. Thus, DCBs appear to be an attractive alternative for the interventional, stentless treatment of suitable de-novo coronary lesions.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Desenho de Equipamento , Europa (Continente) , Feminino , Humanos , Malásia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
J Interv Cardiol ; 2019: 6548696, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31772539

RESUMO

OBJECTIVES: We analyzed the efficacy of drug coated balloons (DCB) as a stand-alone-therapy in de novo lesions of large coronary arteries. DCBs seem to be an attractive alternative for the stent-free interventional treatment of de novo coronary artery disease (CAD). However, data regarding a DCB-only approach in de novo CAD are currently limited to vessels of small caliber. METHODS: By means of propensity score (PS) matching 234 individuals with de novo CAD were identified with similar demographic characteristics. This patient population was stratified in a 1:1 fashion according to a reference vessel diameter cut-off of 2.75 mm in small and large vessel disease. The primary endpoint was the rate of clinically driven target lesion revascularization (TLR) at 9 months. RESULTS: Patients with small vessel disease had an average reference diameter of 2.45 ± 0.23 mm, while the large vessel group averaged 3.16 ± 0.27 mm. Regarding 9-month major adverse cardiac event (MACE), 5.7% of the patients with small and 6.1% of the patients with large vessels had MACE (p=0.903). Analysis of the individual MACE components revealed a TLR rate of 3.8% in small and 1.0% in large vessels (p=0.200). Of note, no thrombotic events in the DCB treated coronary segments occurred in either group during the 9-month follow-up. CONCLUSIONS: Our data demonstrate for the first time that DCB-only PCI of de novo lesions in large coronary arteries (>2.75 mm) is safe and as effective. Interventional treatment for CAD without permanent or temporary scaffolding, demonstrated a similar efficacy for large and small vessels.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Complicações Pós-Operatórias/epidemiologia , Idoso , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Pontuação de Propensão , Resultado do Tratamento
3.
Cardiology ; 142(2): 93-96, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31079093

RESUMO

To date, very little is known about the performance of a sirolimus-eluting bioresorbable magnesium scaffold (Mg-BRS) in patients with acute myocardial infarction (AMI). A multicenter cohort analysis was performed on 69 consecutive AMI subjects treated with Mg-BRS. Procedural success was obtained in all cases, and no in-hospital events were reported. At 9-month follow-up, no cardiac death, target-vessel myocardial infarction, ischemia-driven target lesion revascularization, or Mg-BRS thrombosis was reported. Although our analysis showed encouraging results, larger studies and longer-term follow-up are needed to better understand the potential benefits associated with the use of a Mg-BRS in AMI patients.


Assuntos
Implantes Absorvíveis , Stents Farmacológicos , Magnésio/administração & dosagem , Infarto do Miocárdio/cirurgia , Sirolimo/administração & dosagem , Doença Aguda , Idoso , Seguimentos , Humanos , Itália , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Desenho de Prótese , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 91(3): 444-453, 2018 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-29068130

RESUMO

BACKGROUND: Data on the clinical performance of bioresorbable scaffolds in patients with diabetes mellitus (DM) are still limited. The present study reported 1-year clinical outcomes associated with the use of everolimus-eluting bioresorbable vascular scaffolds (Absorb BVS; Abbott Vascular, Santa Clara, CA) in DM patients. METHODS AND RESULTS: This was a subanalysis from the GHOST-EU (Gauging coronary Healing with biOresorbable Scaffolding plaTforms in Europe) multicenter retrospective registry including patients treated with Absorb BVS between November 2011 and September 2014. In this study, a comparative analysis stratified according to DM was performed. The primary endpoint was target lesion failure (TLF), defined as the combination of cardiac death, target-vessel myocardial infarction (MI) and clinically-driven target-lesion revascularization (TLR). A total of 1,477 patients were treated with 2,224 Absorb BVS; 381 (25.8%) and 1,096 (74.2%) patients were with and without DM, respectively. The 1-year rate of TLF was higher among patients with DM (7.8%) than those without DM (4.3%); the increase in TLF was driven by TLR (6.5% vs. 3.3%, P = 0.009); no significant differences in cardiac death (1.1% vs. 0.9%, P = 0.68) and target-vessel MI (3.1% vs. 2.2%, P = 0.38) were observed, respectively. Definite/probable scaffold thrombosis rate tended to be higher among patients with DM than those without DM (3.0% vs. 1.7%, P = 0.14, respectively). CONCLUSIONS: Absorb BVS use in patients with DM was associated with increased 1-year TLF and scaffold thrombosis compared with non-diabetes patients.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/cirurgia , Diabetes Mellitus , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/epidemiologia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidade , Europa (Continente)/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
Heart Lung Circ ; 27(8): 940-951, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29503240

RESUMO

Coronary artery fistula (CAF) is a relatively rare anatomic abnormality of the coronary arteries that afflicts 0.002% of the general population and represents 14% of all the anomalies of coronary arteries. Its clinical relevance focusses mainly on the mechanism of "coronary steal phenomenon", causing myocardial functional ischaemia even in the absence of stenosis, hence common symptoms are angina or effort dyspnoea. The suggested diagnostic approach is guided by the patient's symptoms and consists of a number of instrumental examinations like ECG, treadmill test, echocardiography, computed tomography scan, cardiac magnetic resonance and coronary angiography. If it is not an incidental finding, coronary angiography is required in view of the optimal therapeutic planning. Small-sized fistulae are usually asymptomatic and have an excellent prognosis if managed medically with clinical follow-up with echocardiography every 2 to 5 years. In the case of symptomatic, large-sized or giant fistulae an invasive treatment, by transcatheter approach or surgical ligation, is usually a reasonable choice, and both strategies show equivalent results at long-term follow-up. Antibiotic prophylaxis for the prevention of bacterial endocarditis is recommended in all patients with coronary artery fistulae who undergo dental, gastrointestinal or urological procedures. A life-long follow-up is always essential to ensure that the patient is not undergoing progression of disease or further cardiac complications.


Assuntos
Cateterismo Cardíaco/métodos , Doença da Artéria Coronariana/diagnóstico , Gerenciamento Clínico , Guias de Prática Clínica como Assunto , Fístula Vascular/diagnóstico , Procedimentos Cirúrgicos Vasculares/métodos , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/cirurgia , Vasos Coronários , Humanos , Ligadura , Imagem Cinética por Ressonância Magnética , Fístula Vascular/cirurgia
6.
Catheter Cardiovasc Interv ; 89(1): 47-56, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27414021

RESUMO

OBJECTIVES: The aim of this study was to evaluate midterm outcomes of bioresorbable vascular scaffolds (BVS) implanted in bifurcation lesions. BACKGROUND: BVS have emerged as an alternative to conventional metallic drug-eluting stents for the treatment of coronary complex lesions. METHODS: Between November 2011 and January 2014, 1189 patients underwent percutaneous coronary intervention with BVS at 10 European centers (GHOST EU registry). Of these, 289 consecutive patients (302 bifurcation lesions) treated with either single-stenting (n = 260) or double-stenting (n = 42) were evaluated. RESULTS: True bifurcations were treated in 44.7%. Intravascular ultrasound and optical coherence tomography were utilized only in 22.2% and 21.2%, respectively. Predilation was performed in 95.4%, while postdilation of the main branch was performed in 61.3%. Final kissing inflation with no or minimal protrusion of a side-branch balloon into main branch was performed in 18.9%. Median follow-up period was 356 (IQR 191-419) days. The Kaplan-Meier estimated rates of target lesion failure and scaffold thrombosis (ST) were 6.4% and 2.5% at 360 days, respectively. Independent predictors for TLF were ACS and diabetes mellitus (HR 4.67; 95% CI: 1.78-12.3; P = 0.002 and HR 3.37; 95% CI: 1.38-8.26; P = 0.008, respectively). CONCLUSIONS: BVS use for coronary bifurcation lesions in an "all-comer" population was associated with acceptable TLF rates up to midterm follow-up. However, ST rates were higher than seen with contemporary metallic stents possibly due to the low incidence of intravascular guidance and postdilation resulting in a higher likelihood of scaffold underexpansion and malapposition, further supporting the importance of meticulous implantation technique. © 2016 Wiley Periodicals, Inc.


Assuntos
Implantes Absorvíveis , Síndrome Coronariana Aguda/terapia , Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/terapia , Stents , Síndrome Coronariana Aguda/diagnóstico por imagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Trombose Coronária/etiologia , Europa (Continente) , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Modelos de Riscos Proporcionais , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção
7.
Catheter Cardiovasc Interv ; 89(5): 812-818, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27515568

RESUMO

BACKGROUND: Overlapping implantation of bioresorbable scaffolds (BRSs) are frequent in long coronary lesions. Its impact on clinical outcomes is unknown. OBJECTIVE: To compare the clinical outcomes of patients treated with overlapping BRS with those patients treated with no-overlap BRS. METHODS: We analyzed the 1-year clinical outcomes of 1,477 patients treated with BRS in the GHOST-EU registry, according to the implantation of overlapping BRS. Primary endpoint was patient oriented composite endpoint (PoCE) of: all-cause death, any myocardial infarction (MI) and any repeated revascularization. Scaffold thrombosis, according to Academic Research Consortium definition, was also analyzed. RESULTS: A total of 320 (21.7%) patients were treated with overlapping BRS (overlap group), whereas the remaining 1,157 (78.3%) received no-overlap BRS (no-overlap group). The overlap group had significantly higher frequency of male sex, diabetes mellitus, stable angina, B2/C lesion type, SYNTAX score ≥22, lesion length >34 mm, use of intracoronary imaging guidance, pre- and postdilatation. At 1-year, there were no differences in PoCE between the overlap versus no-overlap group (18.4% vs. 18.2%; HR 1.07, [0.80-1.44]; P = 0.636), even after adjustment (HR 1.05, [0.48-2.20]; P = 0.904). Scaffold thrombosis rate did not differ either at one-month (1.3% vs. 1.5%, P = 0.769) or at 1-year (1.9% vs. 2.1%, P = 0.823). CONCLUSIONS: In "Real-world" clinical practice, overlapping BRS does not appear to have an impact on clinical outcomes as compared to no-overlapping BRS. These preliminary data should be confirmed. © 2016 Wiley Periodicals, Inc.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Everolimo/farmacologia , Intervenção Coronária Percutânea/métodos , Sistema de Registros , Alicerces Teciduais , Doença da Artéria Coronariana/diagnóstico , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Humanos , Imunossupressores/farmacologia , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Fatores de Tempo
8.
ARYA Atheroscler ; 19(1): 61-64, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38883154

RESUMO

BACKGROUND: Ehlers-Danlos syndrome (EDS) is a hereditary collagen vascular disorder characterized by joint hypermobility, skin hyperextensibility, and tissue fragility. Vascular EDS (vEDS) is a subtype of EDS which is characterized by vascular fragility. CASE PRESENTATION: This is a case report of a young man with vEDS hospitalized for myocardial infarction. He was presented with a coronary dissection and developed aortic dissection, coronary rupture, and cardiac tamponade until death. CONCLUSION: This case report highlights how patients with vEDS and acute coronary syndrome show a higher risk of vascular complications compared with other patients, and their admission to the institution with a cardiac surgery room could be helpful and safe for better management of the complications. Non-invasive methods could be useful to exclude other vascular diseases, before the emergency coronary intervention.

9.
J Clin Med ; 12(20)2023 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-37892796

RESUMO

This study aimed to compare the peri-procedural success and complication rate within a large registry of intra-cardiac echocardiography (ICE)- vs. transesophageal echocardiography (TEE)-guided left atrial appendage occlusion (LAAO) procedures with a Watchmann FLX device. Data from 772 LAAO procedures, performed at 26 Italian centers, were reviewed. Technical success was considered as the final implant of a Watchmann FLX device in LAA; the absence of pericardial tamponade, peri-procedural stroke and/or systemic embolism, major bleeding and device embolization during the procedure was defined as a procedural success. One-year stroke and major bleeding rates were evaluated as outcome. ICE-guided LAA occlusion was performed in 149 patients, while TEE was used in 623 patients. Baseline characteristics were similar between the ICE and TEE groups. The technical success was 100% in both groups. Procedural success was also extremely high (98.5%), and was comparable between ICE (98.7%) and TEE (98.5%). ICE was associated with a slightly longer procedural time (73 ± 31 vs. 61.9 ± 36 min, p = 0.042) and shorter hospital stay (5.3 ± 4 vs. 5.8 ± 6 days, p = 0.028) compared to the TEE group. At one year, stroke and major bleeding rates did not differ between the ICE and TEE groups. A Watchmann FLX device showed high technical and procedural success rate, and ICE guidance does not appear inferior to TEE.

10.
Front Cardiovasc Med ; 10: 1115811, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37180775

RESUMO

Introduction: The Watchman FLX is a novel device for transcatheter left atrial appendage occlusion (LAAO) specifically designed to improve procedural performance in more complex anatomies with a better safety profile. Recently, small prospective non-randomized studies have shown good procedural success and safety compared with previous experiences. Results from large multicenter registries are needed to confirm the safety and efficacy of the Watchman FLX device in a real-world setting. Methods: Italian FLX registry is a retrospective, non-randomized, multicentric study across 25 investigational centers in Italy including consecutive patients undergoing LAAO with the Watchman FLX between March 2019 and September 2021 (N = 772). The primary efficacy outcome was the technical success of the LAAO procedure (peri-device flow ≤ 5 mm) as assessed by intra-procedural imaging. The peri-procedural safety outcome was defined as the occurrence of one of the following events within 7 days after the procedure or by hospital discharge: death, stroke, transient ischemic attack, major extracranial bleeding (BARC type 3 or 5), pericardial effusion with tamponade or device embolization. Results: A total of 772 patients were enrolled. The mean age was 76 ± 8 with a mean CHA2DS2-VASc score of 4.1 ± 1.4 and a mean HAS-BLED score of 3.7 ± 1.1. Technical success was achieved in 772 (100%) patients with the first device implanted in 760 (98.4%) patients. A peri-procedural safety outcome event occurred in 21 patients (2.7%) with major extracranial bleeding being the most common (1.7%). No device embolization occurred. At discharge 459 patients (59.4%) were treated with dual antiplatelet therapy (DAPT). Conclusions: The Italian FLX registry represents the largest multicenter retrospective real-world study reporting periprocedural outcome of LAAO with the Watchman FLX device, resulting in a procedural success rate of 100% and a low incidence of peri-procedural major adverse events (2.7%).

11.
Front Cardiovasc Med ; 10: 1326091, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38299080

RESUMO

Introduction: The use of contemporary drug-eluting stents (DES) has significantly improved outcomes of patients with coronary artery disease (CAD) undergoing percutaneous coronary intervention (PCI). However, concerns exist regarding the long-term proinflammatory effects of durable polymer coatings used in most DES, potentially leading to long-term adverse events. First-generation polymer-free stent technologies, such as sirolimus- and probucol-eluting stents (PF-SES), have shown an excellent safety and efficacy profile. The aim of this study was to evaluate the safety and efficacy of the new ultrathin Coroflex ISAR NEO PF-SES, in a more-comers PCI population. Methods: The CAESAR (a more-Comers populAtion trEated with an ultrathin struts polimer-free Sirolimus stent: An Italian post-maRketing study) registry is a multicenter, prospective study conducted in Italy, enrolling more-comers CAD patients undergoing PCI with the Coroflex ISAR NEO stent. Patients with left main (LM) disease, cardiogenic shock (CS), or severely reduced left-ventricular ejection fraction (LVEF) were excluded. The primary endpoint was target-lesion revascularization (TLR) at 1 year. Results: A total of 425 patients were enrolled at 13 centers (mean age 66.9 ± 11.6 years, Diabetes mellitus 29%, acute coronary syndrome 67%, chronic total occlusion 9%). Of these, 40.9% had multivessel disease (MVD) and in 3.3% cases, the target lesion was in-stent restenosis (ISR). Clinical device success was reached in 422 (99.6%) cases. At 1 year, only two (0.5%) subjects presented ischemia-driven TLR. The 1-year rates of target vessel revascularization and MACE were 0.5% and 5.1%, respectively. Major bleeding was observed in four (1.0%) patients. Conclusion: In this multicenter, prospective registry, the use of a new ultrathin Coroflex ISAR NEO PF-SES in a more-comers PCI population showed good safety and efficacy at 1 year.

12.
EuroIntervention ; 18(13): e1108-e1119, 2023 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-36043326

RESUMO

BACKGROUND: Data on left main (LM) percutaneous coronary interventions (PCI) have mostly been obtained in studies using drug-eluting stent (DES) platforms without dedicated large-vessel devices and with limited expansion capability. AIMS: Our study aimed to investigate the safety and efficacy of LM PCI with the latest-generation Resolute Onyx DES. METHODS: ROLEX (Revascularization Of LEft main with resolute onyX) is a prospective, multicentre study (ClinicalTrials.gov: NCT03316833) enrolling patients with unprotected LM coronary artery disease and a SYNTAX score <33 undergoing PCI with the Resolute Onyx zotarolimus-eluting coronary stent, that includes dedicated extra-large vessel platforms. The primary endpoint (EP) was target lesion failure (TLF): a composite of cardiac death, target vessel myocardial infarction (TVMI) and ischaemia-driven target lesion revascularisation (ID-TLR), at 1 year. All events were adjudicated by an independent clinical event committee. An independent core lab analysed all procedural angiograms. RESULTS: A total of 450 patients (mean age 71.8 years, SYNTAX score 24.5±7.2, acute coronary syndrome in 53%) were enrolled in 26 centres. Of these, 77% of subjects underwent PCI with a single-stent and 23% with a 2-stent technique (8% double kissing [DK] crush, 6% culotte, 9% T/T and small protrusion [TAP] stenting). Intravascular imaging guidance was used in 45% (42% intravascular ultrasound [IVUS], 3% optical coherence tomography [OCT]). At 1 year, the primary EP incidence was 5.1% (cardiac death 2.7%, TVMI 2.7%, ID-TLR 2.0%). The definite/probable stent thrombosis rate was 1.1%. In a prespecified adjusted subanalysis, the primary EP incidence was significantly lower in patients undergoing IVUS/OCT-guided versus angio-guided PCI (2.0 vs 7.6%; hazard ratio [HR] 0.28, 95% confidence interval [CI]: 0.13-0.58; p<0.001). CONCLUSIONS: In this large, multicentre, prospective registry, LM PCI with the Resolute Onyx DES showed good safety and efficacy at 1 year, particularly when guided by intracoronary imaging.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Idoso , Intervenção Coronária Percutânea/efeitos adversos , Stents Farmacológicos/efeitos adversos , Resultado do Tratamento , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Infarto do Miocárdio/etiologia , Stents/efeitos adversos , Angiografia/efeitos adversos , Angiografia Coronária/métodos
13.
Cardiovasc Revasc Med ; 30: 1-8, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33077393

RESUMO

AIM: To compare the long-term outcomes of patients implanted with Absorb bioresorbable scaffold (BRS) with optimal versus suboptimal technique. METHODS AND RESULTS: All patients who received an Absorb between March 2012 and January 2016 were selected from 19 Italian centers databases to assess the impact of an optimal implantation technique (CIAO criteria) on long-term device-oriented composite end-point (DOCE) - including cardiac death (CD), target-vessel myocardial infarction (TV-MI) and ischemia-driven target lesion revascularization (ID-TLR) - on its single components and on scaffold thrombosis (ScT). CIAO criteria consist of predilation (balloon/vessel ratio 1:1), correct sizing (BRS/proximal reference vessel diameter -RVD- ratio 0.8-1.2) and high-pressure postdilation with non-compliant (NC) balloon (≥20 atm for balloon/BRS ratio 1:1 or ≥16 atm for a 0.25-0.5 mm oversized balloon). Among the 1.434 patients analyzed, 464 (32.4%) fulfilled all CIAO criteria for every BRS implanted (CIAO 3 group), while 970 (67.6%) did not in at least one of the received BRS (CIAO 0-1-2 group). At 31.0 (interquartile range -IQR- 24.8-38.5) months follow-up, CIAO criteria did not impact on DOCE (8.2% vs. 8.0%, p = 0.92), ID-TLR (6.9% vs. 7.1%, p = 0.72) or ScT (1.9% vs. 1.8%, p = 0.80) in the overall population. At multivariate analysis overall BRS length (p = 0.001), severely calcified lesions (p = 0.03) and absence of CIAO criteria (CIAO 0, p = 0.005) were independent predictors of DOCE in long-term follow-up. CONCLUSION: Our data suggest that strict application of an optimal Absorb implantation technique doesn't improve long-term DOCE or ScT but may mitigate the worse outcome of patients with calcific lesions.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Implantes Absorvíveis , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento
14.
Future Cardiol ; 16(6): 635-643, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32519916

RESUMO

Background: Epicardial fat increase has not yet a clear correlation with coronary artery disease (CAD). Aim: This study had as goal to demonstrate a relationship between an increase of epicardial fat thickness (EFT) and CAD. Materials & methods: In this observational study, we included 234 patients who underwent invasive coronary angiography. Before invasive coronary angiography, all patients underwent echocardiographic-2D for evaluation of EFT and they were divided into groups based on Gensini score and also on Syntax score. Results: EFT was significantly correlated to the presence and severity of CAD assessed by Gensini score with a cut-off value of 5.2 mm (sensitivity of 90.9%-specificity of 87.3%- area under the ROC curve = 92.1%). Conclusion: EFT increase (fat index ≥5.2 mm) evaluated by echocardiographic-2D could be considered as a risk factor for predicting CAD.


Assuntos
Doença da Artéria Coronariana , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Ecocardiografia , Humanos , Índice de Gravidade de Doença
15.
J Thorac Dis ; 9(12): 5363-5367, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29312747

RESUMO

Spontaneous coronary artery dissection (SCAD) is still today an underdiagnosed disease due to the absence of angiographic hallmarks in more than 70% of cases. In several cases, an intravascular imaging is a sole tool for recognizing a dissection. Particularly, optical coherence tomography analysis (OCT) could represent the gold standard technique of easy interpretation and prompt diagnosis. Here we present a rare case of multivessel spontaneous coronary artery disease (SCAD) with atypical collateral circulation.

16.
Int J Cardiol ; 231: 54-60, 2017 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-28104306

RESUMO

BACKGROUND: To assess clinical outcomes of patients needing short dual antiplatelet therapy (S-DAPT) after PCI with Cre8 polymer-free amphilimus eluting-stent (AES). The Cre8-AES with pure i-Carbofilm coating was supposed to induce faster stent endothelialization and reduce device thrombogenicity. METHODS: We performed a sub-analysis of unrestricted consecutive patients treated with Cre8-AES between August 2011 and January 2015. Two groups were formed: 1) patients discharged with S-DAPT (≤3-month), because of high bleeding risk or attending urgent non-cardiac surgery; and 2) patients discharged with Recommended DAPT duration (R-DAPT; ≥6-month). The primary ischemic- and bleeding-safety endpoints were Target Vessel Failure (TVF, composite endpoint of cardiac-death, target vessel-myocardial infarction and target vessel-revascularization), and major-bleeding (BARC ≥type-3a) at 6-month and 1-year. RESULTS: 106 patients (8.7%) were discharged with ≤3-month DAPT (83±19days; S-DAPT group) and 1102 patients (90.6%) with ≥6-month DAPT (342±62days; R-DAPT group). Between S-DAPT and R-DAPT groups no significant differences were observed in TVF at 1-year (5.7% vs 5.1%); 1-year BARC major bleeding rate was higher in S-DAPT group (3.4% vs 0.2%, p=0.007) with all bleeding events occurred within 3months. The landmark analysis (started at 90days, ended at 1year) showed no differences in BARC major bleedings between groups (0% vs. 0.3%). CONCLUSIONS: The results of this multicenter registry show that the use of Cre8 AES in patients needing short DAPT (≤3-month) was safe regarding ischemic events and could favor a reduction of bleeding events related to the recommended DAPT. A large randomized trial is necessary to support these preliminary findings.


Assuntos
Síndrome Coronariana Aguda/cirurgia , Reestenose Coronária/prevenção & controle , Stents Farmacológicos , Oclusão de Enxerto Vascular/prevenção & controle , Revascularização Miocárdica/métodos , Inibidores da Agregação Plaquetária/uso terapêutico , Polímeros , Síndrome Coronariana Aguda/tratamento farmacológico , Idoso , Reestenose Coronária/epidemiologia , Feminino , Seguimentos , Oclusão de Enxerto Vascular/epidemiologia , Humanos , Incidência , Itália/epidemiologia , Masculino , Sistema de Registros , Estudos Retrospectivos , Espanha/epidemiologia , Fatores de Tempo
17.
JACC Cardiovasc Interv ; 10(6): 560-568, 2017 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-28259663

RESUMO

OBJECTIVES: The authors sought to investigate 1-year outcomes in patients treated with bioresorbable everolimus-eluting vascular scaffolds (BVS) for "long coronary lesions." BACKGROUND: The present substudy derived from the GHOST-EU registry included 1,722 lesions in 1,468 consecutive patients, enrolled between November 2011 and September 2014 at 11 European centers. METHODS: The lesions were divided into 3 groups according to continuous BVS length: 1) shorter than 30 mm; 2) between 30 and 60 mm; and 3) longer than 60 mm. Primary device-oriented endpoint (target lesion failure [TLF]) was defined as a combination of cardiovascular death, target vessel myocardial infarction, or clinically driven target lesion revascularization. RESULTS: Patients with lesions ≥60 mm had more comorbidities and more complex lesion characteristics, including chronic total occlusions (37%), bifurcation lesions (40.3%), higher Syntax score (16.4 ± 7.8), and higher number of scaffolds implanted per lesion (3.3 ± 0.9 mm). The main target vessel was the left anterior coronary artery in all groups. Median follow-up was 384 (interquartile range: 359 to 459) days. One-year follow-up was completed in 70.3% of patients. TLF at 1 year was significantly higher in group C (group A 4.8%, group B 4.5%, group C 14.3%; overall p = 0.001), whereas there were no significant differences between groups A and B. Finally, a numerically higher (but not statistically significant) number of scaffold thromboses were observed in group C when compared with shorter lesions (group A 2.1%, group B 1.1%, group C 3.8%; overall p = 0.29). CONCLUSIONS: In a real-world setting, treatment of long coronary lesions with BVS ≥60 mm was associated with a higher TLF rate, driven by myocardial infarction and clinically driven target lesion revascularization.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Idoso , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Europa (Continente) , Everolimo/efeitos adversos , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Modelos de Riscos Proporcionais , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
18.
EuroIntervention ; 13(9): e1104-e1111, 2017 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-28320687

RESUMO

AIMS: The aim of this study was to report on the midterm outcomes of patients undergoing percutaneous coronary intervention with bioresorbable vascular scaffolds (BVS) for the treatment of acute coronary syndromes (ACS) and compare with those of patients with stable coronary artery disease (sCAD). METHODS AND RESULTS: One thousand four hundred and seventy-seven (1,477) patients underwent implantation of one or more BVS (Absorb BVS; Abbott Vascular, Santa Clara, CA, USA) at 11 European centres and were included in the GHOST-EU registry. Admissions comprised 47.1% of the patients (951 BVS) with ACS, and 52.8% (1,274 BVS) with sCAD. During a median follow-up of 384 (359-460) days, patient-oriented endpoints (PoCE), including all-cause death, any infarction, any revascularisation, were recorded in 271 patients (12-month incidence in ACS patients: 18.5% vs. 11.6% in the sCAD group, p<0.001). Device-oriented composite endpoints (DoCE), cardiac death, target vessel infarction and target lesion revascularisation, were observed in 98 patients (12-month incidence of 4.2% in the sCAD group, 6.4% in the ACS group; p=0.052). The 12-month incidence of definite scaffold thrombosis was 2.6% in ACS patients and 0.8% in XIENCE patients (p=0.006). In multivariate analysis, ACS was a predictor of DoCE (HR: 2.26 [1.34-3.81], p=0.002), PoCE (HR: 1.71 [1.13-2.58], p=0.011), and stent thrombosis (HR: 2.51 [1.13-5.60], p=0.025). In contrast, the incidence of target lesion revascularisation was not different between groups. There was no difference in the incidence of any of these endpoints among the different clinical presentations (unstable angina, non-ST-elevation infarction and ST-elevation infarction). CONCLUSIONS: PoCE, DoCE and scaffold thromboses were more frequent in ACS patients, without any difference among different forms of ACS.


Assuntos
Síndrome Coronariana Aguda/terapia , Intervenção Coronária Percutânea/estatística & dados numéricos , Sistema de Registros , Alicerces Teciduais , Idoso , Doença da Artéria Coronariana/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
19.
EuroIntervention ; 12(17): 2110-2117, 2017 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-28246060

RESUMO

AIMS: The aim of the study was to develop a scoring model to evaluate the quality of bioresorbable vascular scaffold (BVS) implantation and determine the model's usefulness in predicting adverse cardiac events. METHODS AND RESULTS: The implantation technique and clinical outcomes of 1,736 lesions treated with BVS were analysed using the GHOST-EU registry. Predilation, scaffold sizing, and post-dilation (PSP) were scored according to the hazard model derived from the weight of these variables. The primary endpoint was a one-year device-oriented composite endpoint (DoCE) composed of cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularisation. Definite/probable scaffold thrombosis was also evaluated as defined by the Academic Research Consortium. The PSP model performance was evaluated by internal validation. Predilation, correct scaffold sizing, and post-dilation with a non-compliant balloon were performed in 95.7%, 50.2%, and 26.2% of the cases and scored 0.63, 1.96 and 1.93 points, respectively, in the PSP-1 model. PSP-1 was an independent predictor of one-year DoCE (HR 0.75, 95% CI: 0.61-0.93; p=0.007), but with poor calibration and discrimination (AUC 0.611, 95% CI: 0.545-0.677). No patient with a maximum PSP-1 score had scaffold thrombosis, compared to those with a non-maximum PSP-1 score (0% vs. 2.3%; p=0.095). CONCLUSIONS: At one-year follow-up, the PSP-1 score was an independent predictor of DoCE. External validation and prospective studies are needed to determine the clinical usefulness of this score.


Assuntos
Implante de Prótese Vascular/normas , Modelos Teóricos , Avaliação de Resultados em Cuidados de Saúde/métodos , Complicações Pós-Operatórias , Antineoplásicos , Prótese Vascular , Everolimo , Humanos , Estudos Retrospectivos , Medição de Risco , Alicerces Teciduais
20.
EuroIntervention ; 11(14): e1589-95, 2016 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-27056119

RESUMO

AIMS: Our aim was to assess the feasibility and results of a hybrid approach with a bioresorbable scaffold (BRS) plus a drug-coated balloon (DCB) for the treatment of diffuse coronary artery disease (CAD). METHODS AND RESULTS: A retrospective analysis was performed on consecutive patients with diffuse de novo or in-stent restenosis treated with BRS implantation (larger proximal segment) and DCB inflation (smaller distal segment or bifurcation side branch). Endpoints were procedural success, then ischaemia-driven target lesion revascularisation (ID-TLR) and BRS/DCB segment thrombosis rates at follow-up. A total of 42 consecutive patients were treated with the hybrid strategy. Mean patient age was 62±1.02 years, while 12 (28.6%) patients were diabetics. Mean BRS and DCB length were 28.0±5.1 mm and 25.8±8.8 mm, respectively. Procedural success was obtained in all patients, but three (7.3%) patients required bail-out scaffolding for DCB-related dissection. At a median follow-up of 12 months (IQR: 6-18), there were no cases of cardiac death, target vessel myocardial infarction, or BRS/DCB segment thrombosis. ID-TLR occurred in two (4.7%) BRS-treated segments. CONCLUSIONS: Our data in consecutive patients with diffuse CAD suggest that a hybrid strategy using BRS and DCB in different segments of the diseased vessel is feasible and associated with encouraging clinical outcomes.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/cirurgia , Reestenose Coronária/cirurgia , Stents Farmacológicos , Idoso , Angioplastia Coronária com Balão/métodos , Stents Farmacológicos/efeitos adversos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/cirurgia , Projetos Piloto , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa