Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Am J Respir Crit Care Med ; 208(12): 1293-1304, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37774011

RESUMO

Rationale: The effects of high-dose inhaled nitric oxide on hypoxemia in coronavirus disease (COVID-19) acute respiratory failure are unknown. Objectives: The primary outcome was the change in arterial oxygenation (PaO2/FiO2) at 48 hours. The secondary outcomes included: time to reach a PaO2/FiO2.300mmHg for at least 24 hours, the proportion of participants with a PaO2/FiO2.300mmHg at 28 days, and survival at 28 and at 90 days. Methods: Mechanically ventilated adults with COVID-19 pneumonia were enrolled in a phase II, multicenter, single-blind, randomized controlled parallel-arm trial. Participants in the intervention arm received inhaled nitric oxide at 80 ppm for 48 hours, compared with the control group receiving usual care (without placebo). Measurements and Main Results: A total of 193 participants were included in the modified intention-to-treat analysis. The mean change in PaO2/FiO2 ratio at 48 hours was 28.3mmHg in the intervention group and 21.4mmHg in the control group (mean difference, 39.1mmHg; 95% credible interval [CrI], 18.1 to 60.3). The mean time to reach a PaO2/FiO2.300mmHg in the interventional group was 8.7 days, compared with 8.4 days for the control group (mean difference, 0.44; 95% CrI, 23.63 to 4.53). At 28 days, the proportion of participants attaining a PaO2/FiO2.300mmHg was 27.7% in the inhaled nitric oxide group and 17.2% in the control subjects (risk ratio, 2.03; 95% CrI, 1.11 to 3.86). Duration of ventilation and mortality at 28 and 90 days did not differ. No serious adverse events were reported. Conclusions: The use of high-dose inhaled nitric oxide resulted in an improvement of PaO2/FiO2 at 48 hours compared with usual care in adults with acute hypoxemic respiratory failure due to COVID-19.


Assuntos
COVID-19 , Insuficiência Respiratória , Adulto , Humanos , Óxido Nítrico/uso terapêutico , COVID-19/complicações , Método Simples-Cego , Insuficiência Respiratória/tratamento farmacológico , Insuficiência Respiratória/etiologia , Respiração Artificial , Administração por Inalação
2.
Am J Med Genet A ; 191(12): 2898-2902, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37655511

RESUMO

We report a 10-year-old boy with a de novo pathogenic variant in ALDH18A1, a rare form of metabolic cutis laxa, which was complicated by atlantoaxial instability and spinal cord compression following a fall from standing height. The patient required emergent cervical spine fusion and decompression followed by a 2-month hospitalization and rehabilitation. In addition to the core clinical features of joint and skin laxity, hypotonia, and developmental delays, we expand the connective tissue phenotype by adding a new potential feature of cervical spine instability. Patients with pathogenic variants in ALDH18A1 may warrant cervical spine screening to minimize possible morbidity. Neurosurgeons, geneticists, primary care providers, and families should be aware of the increased risk of severe cervical injury from minor trauma.


Assuntos
Cútis Laxa , Instabilidade Articular , Doenças da Coluna Vertebral , Masculino , Humanos , Criança , Instabilidade Articular/diagnóstico , Instabilidade Articular/genética , Cútis Laxa/genética , Mutação , Vértebras Cervicais/cirurgia , Vértebras Cervicais/patologia
3.
Nitric Oxide ; 138-139: 17-25, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37277062

RESUMO

BACKGROUND: Several nitric oxide (NO) generating devices have been developed to deliver NO between 1 part per million (ppm) and 80 ppm. Although inhalation of high-dose NO may exert antimicrobial effects, the feasibility and safety of producing high-dose (more than 100 ppm) NO remains to be established. In the current study, we designed, developed, and tested three high-dose NO generating devices. METHODS: We constructed three NO generating devices: a double spark plug NO generator, a high-pressure single spark plug NO generator, and a gliding arc NO generator. The NO and NO2 concentrations were measured at different gas flows and under various atmospheric pressures. The double spark plug NO generator was designed to deliver gas through an oxygenator and mixing with pure oxygen. The high-pressure and gliding arc NO generators were used to deliver gas through a ventilator into artificial lungs to mimic delivering high-dose NO in the clinical settings. The energy consumption was measured and compared among the three NO generators. RESULTS: The double spark plug NO generator produced 200 ± 2 ppm (mean ± SD) of NO at gas flow of 8 L/min (or 320 ± 3 ppm at gas flow of 5 L/min) with electrode gap of 3 mm. The nitrogen dioxide (NO2) levels were below 3.0 ± 0.1 ppm when mixing with various volumes of pure oxygen. The addition of a second generator increased the delivered NO from 80 (with one spark plug) to 200 ppm. With the high-pressure chamber, the NO concentration reached 407 ± 3 ppm with continuous air flow at 5 L/min when employing the 3 mm electrode gap under 2.0 atmospheric pressure (ATA). When compared to 1 ATA, NO production was increased 22% at 1.5 ATA and 34% at 2 ATA. The NO level was 180 ± 1 ppm when connecting the device to a ventilator with a constant inspiratory airflow of 15 L/min, and NO2 levels were below 1 (0.93 ± 0.02) ppm. The gliding arc NO generator produced up to 180 ± 4 ppm of NO when connecting the device to a ventilator, and the NO2 level was below 1 (0.91 ± 0.02) ppm in all testing conditions. The gliding arc device required more power (in watts) to generate the same concentrations of NO when compared to double spark plug or high-pressure NO generators. CONCLUSIONS: Our results demonstrated that it is feasible to enhance NO production (more than 100 ppm) while maintaining NO2 level relatively low (less than 3 ppm) with the three recently developed NO generating devices. Future studies might include these novel designs to deliver high doses of inhaled NO as an antimicrobial used to treat upper and lower respiratory tract infections.


Assuntos
Óxido Nítrico , Dióxido de Nitrogênio , Terapia Respiratória , Pulmão , Administração por Inalação , Oxigênio
4.
Pediatr Crit Care Med ; 24(5): 356-371, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36995097

RESUMO

OBJECTIVES: Extracorporeal membrane oxygenation (ECMO) has been used successfully to support adults with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-related cardiac or respiratory failure refractory to conventional therapies. Comprehensive reports of children and adolescents with SARS-CoV-2-related ECMO support for conditions, including multisystem inflammatory syndrome in children (MIS-C) and acute COVID-19, are needed. DESIGN: Case series of patients from the Overcoming COVID-19 public health surveillance registry. SETTING: Sixty-three hospitals in 32 U.S. states reporting to the registry between March 15, 2020, and December 31, 2021. PATIENTS: Patients less than 21 years admitted to the ICU meeting Centers for Disease Control criteria for MIS-C or acute COVID-19. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The final cohort included 2,733 patients with MIS-C ( n = 1,530; 37 [2.4%] requiring ECMO) or acute COVID-19 ( n = 1,203; 71 [5.9%] requiring ECMO). ECMO patients in both groups were older than those without ECMO support (MIS-C median 15.4 vs 9.9 yr; acute COVID-19 median 15.3 vs 13.6 yr). The body mass index percentile was similar in the MIS-C ECMO versus no ECMO groups (89.9 vs 85.8; p = 0.22) but higher in the COVID-19 ECMO versus no ECMO groups (98.3 vs 96.5; p = 0.03). Patients on ECMO with MIS-C versus COVID-19 were supported more often with venoarterial ECMO (92% vs 41%) for primary cardiac indications (87% vs 23%), had ECMO initiated earlier (median 1 vs 5 d from hospitalization), shorter ECMO courses (median 3.9 vs 14 d), shorter hospital length of stay (median 20 vs 52 d), lower in-hospital mortality (27% vs 37%), and less major morbidity at discharge in survivors (new tracheostomy, oxygen or mechanical ventilation need or neurologic deficit; 0% vs 11%, 0% vs 20%, and 8% vs 15%, respectively). Most patients with MIS-C requiring ECMO support (87%) were admitted during the pre-Delta (variant B.1.617.2) period, while most patients with acute COVID-19 requiring ECMO support (70%) were admitted during the Delta variant period. CONCLUSIONS: ECMO support for SARS-CoV-2-related critical illness was uncommon, but type, initiation, and duration of ECMO use in MIS-C and acute COVID-19 were markedly different. Like pre-pandemic pediatric ECMO cohorts, most patients survived to hospital discharge.


Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Adulto , Humanos , Criança , Adolescente , COVID-19/terapia , SARS-CoV-2 , Hospitalização , Unidades de Terapia Intensiva , Estudos Retrospectivos
5.
Matern Child Health J ; 27(10): 1898-1903, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37278847

RESUMO

OBJECTIVE: To determine the proportion of small for gestational age (weight < 10th percentile, SGA) births among fathers with lifelong low (compared to high) socioeconomic position (SEP) attributable to white and African-American women's unhealthy pregnancy-related behaviors. METHODS: Oaxaca-Blinder decomposition methods were conducted on the Illinois transgenerational dataset of infants (1989-1991) and their Chicago-born parents (1956-1976) with appended US census income data. The neighborhood income of father's residence at the time of his birth and at the time of his infant's birth were used to estimate his lifetime SEP. Maternal unhealthy pregnancy-related behaviors were defined as cigarette smoking, inadequate prenatal care, and/or low weight gain during pregnancy. RESULTS: Among African-American women, births (n = 4426) to fathers with lifetime low SEP had an SGA rate of 14.8% compared to 12.1% for those (n = 365) born to fathers with lifetime high SEP (p < 0.0001). Among white women, births (n = 1430) to fathers with lifetime low SEP had an SGA rate of 9.8% compared to 6.2% for those (n = 9141) born to fathers with lifetime high SEP (p < 0.0001). Adjusting for maternal age, marital status, education, and parity, African-American and white women's unhealthy pregnancy behaviors accounted for 25% and 33%, respectively, of the disparity in SGA rates among infants of lifetime low (compared to high) SEP fathers. CONCLUSION: A significant proportion of the disparity in SGA rates between fathers with lifelong low (compared to high) SEP is explained in both races by maternal unhealthy pregnancy behaviors.


Assuntos
Recém-Nascido Pequeno para a Idade Gestacional , Comportamento Materno , Lactente , Recém-Nascido , Feminino , Humanos , Gravidez , Masculino , Idade Gestacional , Estado Civil , Pai , Fatores de Risco
6.
Am J Emerg Med ; 58: 5-8, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35623183

RESUMO

BACKGROUND: Inhaled nitric oxide (iNO) is a selective pulmonary vasodilator and mild bronchodilator that has been shown to improve systemic oxygenation, but has rarely been administered in the Emergency Department (ED). In addition to its favorable pulmonary vascular effects, in-vitro studies report that NO donors can inhibit replication of viruses, including SARS Coronavirus 2 (SARS-CoV-2). This study evaluated the administration of high-dose iNO by mask in spontaneously breathing emergency department (ED) patients with respiratory symptoms attributed to Coronavirus disease 2019 (COVID-19). METHODS: We designed a randomized clinical trial to determine whether 30 min of high dose iNO (250 ppm) could be safely and practically administered by emergency physicians in the ED to spontaneously-breathing patients with respiratory symptoms attributed to COVID-19. Our secondary goal was to learn if iNO could prevent the progression of mild COVID-19 to a more severe state. FINDINGS: We enrolled 47 ED patients with acute respiratory symptoms most likely due to COVID-19: 25 of 47 (53%) were randomized to the iNO treatment group; 22 of 47 (46%) to the control group (supportive care only). All patients tolerated the administration of high-dose iNO in the ED without significant complications or symptoms. Five patients receiving iNO (16%) experienced asymptomatic methemoglobinemia (MetHb) > 5%. Thirty-four of 47 (72%) subjects tested positive for SARS-CoV-2: 19 of 34 were randomized to the iNO treatment group and 15 of 34 subjects to the control group. Seven of 19 (38%) iNO patients returned to the ED, while 4 of 15 (27%) control patients did. One patient in each study arm was hospitalized: 5% in iNO treatment and 7% in controls. One patient was intubated in the iNO group. No patients in either group died. The differences between these groups were not significant. CONCLUSION: A single dose of iNO at 250 ppm was practical and not associated with any significant adverse effects when administered in the ED by emergency physicians. Local disease control led to early study closure and prevented complete testing of COVID-19 safety and treatment outcomes measures.


Assuntos
COVID-19 , Insuficiência Respiratória , Administração por Inalação , Serviço Hospitalar de Emergência , Humanos , Óxido Nítrico/uso terapêutico , Insuficiência Respiratória/terapia , SARS-CoV-2
7.
BMC Public Health ; 22(1): 1010, 2022 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-35590303

RESUMO

BACKGROUND: Distribution of long-lasting insecticide treated nets (LLINs) is the most widely used intervention for the prevention of malaria but recall and social desirability biases may lead to challenges in accurately measuring use of bednets. SmartNet is a remote electronic monitor that provides objective measurements of bednet use over weeks at a time. Assessing local acceptability is important when implementing innovative global health technologies such as SmartNet. This study draws on established models such as the Technology Acceptance Model (TAM) and Theoretical Framework of Acceptability (TFA) to assess acceptability of SmartNet in Ugandan households. METHODS: Semi-structured qualitative interviews were conducted at weeks one and six following installation of SmartNet in ten households in Western Uganda. Heads-of-households answered open-ended questions addressing the main acceptability domains of the TFA and TAM models (i.e. perceived ease of use, ethicality, etc.). Responses were digitally recorded, transcribed, coded and analyzed using a thematic analysis approach. RESULTS: Seven out of ten households interviewed reported no difference in use between SmartNet and a standard LLIN. Households stated the large size, soft fabric, and the efficacy of SmartNet relative to a standard LLIN contributed to perceived usefulness and perceived ease of use. Opportunity costs of the novel monitoring system expressed by households included difficulty washing nets and dislike of blinking lights on the device. Barriers to SmartNet use focused on questions of the ethics of bednet use monitoring, discomfort with technical aspects of the device and a poor understanding of its function amongst others in the community. However, explaining SmartNet to other community members resolved these concerns and often resulted in interest and acceptance among peers. CONCLUSION: Objective monitoring of bednet use with SmartNet appears acceptable to these households in Uganda. Use of SmartNet seems to be similar to behaviors around use of standard LLINs. Viewpoints on many aspects of SmartNet were generally favorable. Concerns around ethicality of bednet monitoring are present and indicate the need for continuing community education. The device will continue to be optimized to make it more acceptable to users and to accurately reflect standard LLIN use to improve our understanding of prevention behaviors in malaria endemic settings.


Assuntos
Mosquiteiros Tratados com Inseticida , Malária , Estudos Transversais , Eletrônica , Humanos , Malária/epidemiologia , Malária/prevenção & controle , Controle de Mosquitos , Uganda
8.
Nitric Oxide ; 116: 7-13, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34400339

RESUMO

BACKGROUND: Inhaled nitric oxide (NO) is a selective pulmonary vasodilator. In-vitro studies report that NO donors can inhibit replication of SARS-CoV-2. This multicenter study evaluated the feasibility and effects of high-dose inhaled NO in non-intubated spontaneously breathing patients with Coronavirus disease-2019 (COVID-19). METHODS: This is an interventional study to determine whether NO at 160 parts-per-million (ppm) inhaled for 30 min twice daily might be beneficial and safe in non-intubated COVID-19 patients. RESULTS: Twenty-nine COVID-19 patients received a total of 217 intermittent inhaled NO treatments for 30 min at 160 ppm between March and June 2020. Breathing NO acutely decreased the respiratory rate of tachypneic patients and improved oxygenation in hypoxemic patients. The maximum level of nitrogen dioxide delivered was 1.5 ppm. The maximum level of methemoglobin (MetHb) during the treatments was 4.7%. MetHb decreased in all patients 5 min after discontinuing NO administration. No adverse events during treatment, such as hypoxemia, hypotension, or acute kidney injury during hospitalization occurred. In our NO treated patients, one patient of 29 underwent intubation and mechanical ventilation, and none died. The median hospital length of stay was 6 days [interquartile range 4-8]. No discharged patients required hospital readmission nor developed COVID-19 related long-term sequelae within 28 days of follow-up. CONCLUSIONS: In spontaneous breathing patients with COVID-19, the administration of inhaled NO at 160 ppm for 30 min twice daily promptly improved the respiratory rate of tachypneic patients and systemic oxygenation of hypoxemic patients. No adverse events were observed. None of the subjects was readmitted or had long-term COVID-19 sequelae.


Assuntos
Tratamento Farmacológico da COVID-19 , Hospitalização , Óxido Nítrico/administração & dosagem , Pneumonia Viral/tratamento farmacológico , Respiração/efeitos dos fármacos , Administração por Inalação , COVID-19/complicações , COVID-19/virologia , Relação Dose-Resposta a Droga , Humanos , Óxido Nítrico/farmacologia , Óxido Nítrico/uso terapêutico , Pneumonia Viral/complicações
9.
JAMA ; 325(11): 1074-1087, 2021 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-33625505

RESUMO

Importance: Refinement of criteria for multisystem inflammatory syndrome in children (MIS-C) may inform efforts to improve health outcomes. Objective: To compare clinical characteristics and outcomes of children and adolescents with MIS-C vs those with severe coronavirus disease 2019 (COVID-19). Setting, Design, and Participants: Case series of 1116 patients aged younger than 21 years hospitalized between March 15 and October 31, 2020, at 66 US hospitals in 31 states. Final date of follow-up was January 5, 2021. Patients with MIS-C had fever, inflammation, multisystem involvement, and positive severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) reverse transcriptase-polymerase chain reaction (RT-PCR) or antibody test results or recent exposure with no alternate diagnosis. Patients with COVID-19 had positive RT-PCR test results and severe organ system involvement. Exposure: SARS-CoV-2. Main Outcomes and Measures: Presenting symptoms, organ system complications, laboratory biomarkers, interventions, and clinical outcomes. Multivariable regression was used to compute adjusted risk ratios (aRRs) of factors associated with MIS-C vs COVID-19. Results: Of 1116 patients (median age, 9.7 years; 45% female), 539 (48%) were diagnosed with MIS-C and 577 (52%) with COVID-19. Compared with patients with COVID-19, patients with MIS-C were more likely to be 6 to 12 years old (40.8% vs 19.4%; absolute risk difference [RD], 21.4% [95% CI, 16.1%-26.7%]; aRR, 1.51 [95% CI, 1.33-1.72] vs 0-5 years) and non-Hispanic Black (32.3% vs 21.5%; RD, 10.8% [95% CI, 5.6%-16.0%]; aRR, 1.43 [95% CI, 1.17-1.76] vs White). Compared with patients with COVID-19, patients with MIS-C were more likely to have cardiorespiratory involvement (56.0% vs 8.8%; RD, 47.2% [95% CI, 42.4%-52.0%]; aRR, 2.99 [95% CI, 2.55-3.50] vs respiratory involvement), cardiovascular without respiratory involvement (10.6% vs 2.9%; RD, 7.7% [95% CI, 4.7%-10.6%]; aRR, 2.49 [95% CI, 2.05-3.02] vs respiratory involvement), and mucocutaneous without cardiorespiratory involvement (7.1% vs 2.3%; RD, 4.8% [95% CI, 2.3%-7.3%]; aRR, 2.29 [95% CI, 1.84-2.85] vs respiratory involvement). Patients with MIS-C had higher neutrophil to lymphocyte ratio (median, 6.4 vs 2.7, P < .001), higher C-reactive protein level (median, 152 mg/L vs 33 mg/L; P < .001), and lower platelet count (<150 ×103 cells/µL [212/523 {41%} vs 84/486 {17%}, P < .001]). A total of 398 patients (73.8%) with MIS-C and 253 (43.8%) with COVID-19 were admitted to the intensive care unit, and 10 (1.9%) with MIS-C and 8 (1.4%) with COVID-19 died during hospitalization. Among patients with MIS-C with reduced left ventricular systolic function (172/503, 34.2%) and coronary artery aneurysm (57/424, 13.4%), an estimated 91.0% (95% CI, 86.0%-94.7%) and 79.1% (95% CI, 67.1%-89.1%), respectively, normalized within 30 days. Conclusions and Relevance: This case series of patients with MIS-C and with COVID-19 identified patterns of clinical presentation and organ system involvement. These patterns may help differentiate between MIS-C and COVID-19.


Assuntos
COVID-19 , Síndrome de Resposta Inflamatória Sistêmica , Adolescente , Fatores Etários , Biomarcadores/análise , COVID-19/complicações , COVID-19/diagnóstico , COVID-19/fisiopatologia , COVID-19/terapia , Criança , Pré-Escolar , Diagnóstico Diferencial , Feminino , Humanos , Unidades de Terapia Intensiva Pediátrica , Masculino , Gravidade do Paciente , Análise de Regressão , Volume Sistólico , Síndrome de Resposta Inflamatória Sistêmica/complicações , Síndrome de Resposta Inflamatória Sistêmica/diagnóstico , Síndrome de Resposta Inflamatória Sistêmica/fisiopatologia , Síndrome de Resposta Inflamatória Sistêmica/terapia , Estados Unidos , Adulto Jovem
10.
Nitric Oxide ; 104-105: 29-35, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32835810

RESUMO

BACKGROUND: There is an increasing interest in safely delivering high dose of inhaled nitric oxide (NO) as an antimicrobial and antiviral therapeutics for spontaneously breathing patients. A novel NO delivery system is described. METHODS: We developed a gas delivery system that utilizes standard respiratory circuit connectors, a reservoir bag, and a scavenging chamber containing calcium hydroxide. The performance of the system was tested using a mechanical lung, assessing the NO concentration delivered at varying inspiratory flows. Safety was assessed in vitro and in vivo by measuring nitrogen dioxide (NO2) levels in the delivered NO gas. Lastly, we measured the inspired and expired NO and NO2 of this system in 5 healthy subjects during a 15-min administration of high dose NO (160 parts-per-million, ppm) using our delivery system. RESULTS: The system demonstrated stable delivery of prescribed NO levels at various inspiratory flow rates (0-50 L/min). The reservoir bag and a high flow of entering air minimized the oscillation of NO concentrations during inspiration on average 4.6 ppm for each 10 L/min increment in lung inspiratory flow. The calcium hydroxide scavenger reduced the inhaled NO2 concentration on average 0.9 ppm (95% CI -1.58, -0.22; p = .01). We performed 49 NO administrations of 160 ppm in 5 subjects. The average concentration of inspired NO was 164.8±10.74 ppm, with inspired NO2 levels of 0.7±0.13 ppm. The subjects did not experience any adverse events; transcutaneous methemoglobin concentrations increased from 1.05±0.58 to 2.26±0.47%. CONCLUSIONS: The system we developed to administer high-dose NO for inhalation is easy to build, reliable, was well tolerated in healthy subjects.


Assuntos
Sistemas de Liberação de Medicamentos/instrumentação , Sistemas de Liberação de Medicamentos/métodos , Óxido Nítrico/administração & dosagem , Administração por Inalação , Adulto , Feminino , Humanos , Masculino , Respiração
12.
Trop Med Int Health ; 22(9): 1072-1080, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28627004

RESUMO

OBJECTIVE: Diagnosis of bacterial meningitis often requires cytometry, chemistry and/or microbiologic culture capabilities. Unfortunately, laboratory resources in low-resource settings (LRS) often lack the capacity to perform these studies. We sought to determine whether the presence of white blood cells in CSF detected by commercially available urine reagent strips could aid in the diagnosis of bacterial meningitis. METHODS: We searched PubMed for studies published between 1980 and 2016 that investigated the use of urine reagent strips to identify cerebrospinal fluid (CSF) pleocytosis. We assessed studies in any language that enrolled subjects who underwent lumbar puncture and had cerebrospinal fluid testing by both standard laboratory assays and urine reagent strips. We abstracted true-positive, false-negative, false-positive and true-negative counts for each study using a diagnostic threshold of ≥10 white blood cells per microlitre for suspected bacterial meningitis and performed mixed regression modelling with random effects to estimate pooled diagnostic accuracy across studies. RESULTS: Our search returned 13 studies including 2235 participants. Urine reagent strips detected CSF pleocytosis with a pooled sensitivity of 92% (95% CI: 84-96), a pooled specificity of 98% (95% CI: 94-99) and a negative predictive value of 99% when the bacterial meningitis prevalence is 10%. CONCLUSIONS: Urine reagent strips could provide a rapid and accurate tool to detect CSF pleocytosis, which, if negative, can be used to exclude diagnosis of bacterial meningitis in settings without laboratory infrastructure. Further investigation of the diagnostic value of using protein, glucose and bacteria components of these strips is warranted.


Assuntos
Contagem de Leucócitos/métodos , Leucócitos , Meningites Bacterianas/diagnóstico , Fitas Reagentes , Adolescente , Adulto , Idoso , Bactérias , Hidrolases de Éster Carboxílico/metabolismo , Criança , Pré-Escolar , Recursos em Saúde , Humanos , Lactente , Recém-Nascido , Leucocitose/líquido cefalorraquidiano , Meningites Bacterianas/líquido cefalorraquidiano , Meningites Bacterianas/imunologia , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Punção Espinal , Adulto Jovem
14.
Int J Technol Assess Health Care ; 30(3): 260-4, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25096225

RESUMO

Medical technology offers enormous potential for scalable medicine--to improve the quality and access in health care while simultaneously reducing cost. However, current medical device innovation within companies often only offers incremental advances on existing products, or originates from engineers with limited knowledge of the clinical complexities. We describe how the Hacking Medicine Initiative, based at Massachusetts Institute of Technology has developed an innovative "healthcare hackathon" approach, bringing diverse teams together to rapidly validate clinical needs and develop solutions. Hackathons are based on three core principles; emphasis on a problem-based approach, cross-pollination of disciplines, and "pivoting" on or rapidly iterating on ideas. Hackathons also offer enormous potential for innovation in global health by focusing on local needs and resources as well as addressing feasibility and cultural contextualization. Although relatively new, the success of this approach is clear, as evidenced by the development of successful startup companies, pioneering product design, and the incorporation of creative people from outside traditional life science backgrounds who are working with clinicians and other scientists to create transformative innovation in health care.


Assuntos
Difusão de Inovações , Avaliação da Tecnologia Biomédica/métodos , Reforma dos Serviços de Saúde , Humanos , Internacionalidade , Massachusetts , Universidades
15.
Ann Otol Rhinol Laryngol ; 123(10): 726-33, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24835243

RESUMO

OBJECTIVE: This study aimed to describe the development and implementation of the first sustainable, multidisciplinary, pediatric airway surgical mission in an underserved country. METHODS: This prospective, qualitative study was conducted for the first 4 Operation Airway missions in Quito, Ecuador. The major goals of the missions were to assist children with aerodigestive abnormalities, create a sustainable program where the local team could independently provide for their own patient population, develop an educational curriculum and training program for the local team, and cultivate a collaborative approach to provide successful multidisciplinary care. RESULTS: Twenty patients ages 4 months to 21 years were included. Twenty-three bronchoscopies, 5 salivary procedures, 2 tracheostomies, 1 T-tube placement, 1 tracheocutaneous fistula closure, 2 open granuloma excisions, and 6 laryngotracheal reconstructions (LTRs) were performed. All LTR patients were decannulated. A new type of LTR (1.5 stage) was developed to meet special mission circumstances. Two videofluoroscopic swallow studies and 40 bedside swallow evaluations were performed. One local pediatric otolaryngologist, 1 pediatric surgeon, 3 anesthesiologists, 7 intensivists, 16 nurses, and 2 speech-language pathologists have received training. More than 25 hours of lectures were given, and a website was created collaboratively for educational and informational dissemination (http://www.masseyeandear.org/specialties/pediatrics/pediatric-ent/airway/OperationAirway/). CONCLUSION: We demonstrated the successful creation of the first mission stemming from a teaching institution with the goal of developing a sustainable, autonomous surgical airway program.


Assuntos
Manuseio das Vias Aéreas , Países em Desenvolvimento , Missões Médicas/organização & administração , Otolaringologia , Equipe de Assistência ao Paciente/organização & administração , Pediatria , Adolescente , Criança , Pré-Escolar , Equador , Humanos , Lactente , Avaliação de Programas e Projetos de Saúde , Estudos Prospectivos , Adulto Jovem
16.
Fam Syst Health ; 42(1): 34-49, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38647492

RESUMO

BACKGROUND: Up to 20% of youth have impairing mental health problems as early as age 3. Early identification and intervention of mental health risks in pediatric primary care could mitigate this crisis via prevention prior to disease onset. The purpose of this study was to establish the feasibility and acceptability of implementing a brief transdiagnostic screening instrument in pediatric primary care for irritability and corollary impairment. METHOD: Five pediatric clinicians in a Midwest clinic implemented the Multidimensional Assessment Profiles-Early Assessment Screener of Irritability (MAPS-EASI) for toddlers (24-30 months) and their families. MAPS-EASI (psychometrically derived from the well-validated MAPS-Scales) includes six items (scored 0-5) about symptoms (e.g., tantrums, grumpy mood), context, and frequency and two items (scored 0-3) assessed impairment. Positive screens (MAPS-EASI ≥ 5 plus impairment ≥ 2) were referred to an evidence-based parenting intervention. We assessed reach and outcomes of MAPS-EASI screening. Follow-up interviews with clinicians assessed perspectives on irritability screening and MAPS-EASI implementation. RESULTS: Of 201 eligible families, 100 (49.8%) completed the screener for a 24- or 30-month well-child visit. Mean MAPS-EASI scores were 5.8 (SD = 3.2), mean impairment scores were 0.9 (SD = 0.9), and 24 (24.0%) screened positive. Clinicians indicated that irritability screening for toddlers was aligned with their prevention-oriented, developmentally based practice. MAPS-EASI had face validity and increased clinician decision-making confidence. Finally, clinicians identified barriers and facilitators to large-scale implementation. CONCLUSIONS: MAPS-EASI proved to be feasible and acceptable in pediatric primary care. Further tailoring will be needed as the MAPS-EASI processes are scaled out to new contexts and populations. (PsycInfo Database Record (c) 2024 APA, all rights reserved).


Assuntos
Humor Irritável , Programas de Rastreamento , Atenção Primária à Saúde , Humanos , Feminino , Pré-Escolar , Masculino , Atenção Primária à Saúde/métodos , Atenção Primária à Saúde/estatística & dados numéricos , Atenção Primária à Saúde/normas , Programas de Rastreamento/métodos , Programas de Rastreamento/instrumentação , Programas de Rastreamento/normas , Psicometria/instrumentação , Psicometria/métodos , Pediatras/estatística & dados numéricos , Pediatras/psicologia , Pediatras/normas , Inquéritos e Questionários
17.
J Med Eng Technol ; 47(8): 371-375, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38717814

RESUMO

Access to medical technologies is a critical component of universal access to care; however, the advancement of technologies for children has historically lagged behind those for adults. The small market size, anatomic and physiologic variability, and legal and ethical implications pose unique barriers to developing and commercialising paediatric biomedical innovations. These challenges are magnified in low-resource settings (LRS), which often lack appropriate regulatory oversight, support for service contracts, and supply chain capacity. The COVID-19 pandemic exposed shortcomings in the traditional industry model for medical technologies, while also catalysing open-source approaches to technology development and dissemination. Open-source pathways - where products are freely licenced to be distributed and modified - addressed key shortages in critical equipment. Relatedly, we argue that open-source approaches can accelerate paediatric global health technology development. Open-source approaches can be tailored to clinical challenges independent of economic factors, embrace low-cost manufacturing techniques, and can be highly customisable. Furthermore, diverse stakeholders, including families and patients, are empowered to participate in collaborative communities of practice. How to regulate the development, manufacture, and distribution of open-source technologies remains an ongoing area of exploration. The need for democratised innovation must be carefully balanced against the imperatives of safety and quality for paediatric-specific solutions. This can be achieved, in part, through close coordination between national regulatory agencies and decentralised networks where products can be peer-reviewed and tested. Altogether, there is significant potential for open source to advance more equitable and sustainable medical innovations for all children.


Assuntos
Tecnologia Biomédica , COVID-19 , Saúde Global , Humanos , COVID-19/epidemiologia , Criança , Pediatria , SARS-CoV-2 , Pandemias
18.
Respir Care ; 68(3): 384-391, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36750259

RESUMO

BACKGROUND: Mechanical ventilation of the neonate requires ventilators than can deliver precise and accurate tidal volume (VT) and PEEP to avoid lung injury. Due to small neonatal VT and the disproportionate effect of endotracheal tube leak in these patients, accomplishing precise and accurate VT delivery is difficult. Whereas neonatal ICU ventilators are validated in this population, thorough studies testing the performance of anesthesia ventilators in delivering small VT in neonates are lacking. METHODS: Three anesthesia ventilators, Dräger Apollo, GE Avance, and Getinge Flow-i; and 2 ICU ventilators, Medtronic PB980 and Nihon Kohden NKV-550, were tested under volume control mode at VT of 5, 20, 40, and 60 mL. Three combinations of lung compliance and airway resistance were tested using a Servo ASL 5000 lung simulator. RESULTS: In a scenario without leak, the measured VT was greater than the set VT by > 10% in the Apollo (21.0% [18.8-26.0]); measured VT was less than the set VT by > 10% in the Flow-i (-19% [-20.8 to -18.7]). The Avance, PB980, and NKV-550 presented a volume error < 10% (-9.50% [-10.8 to -4.4], -5.8% [-11.8 to -3.5], and 5.4% [-4.5 to 18.9], respectively). Considering all combinations of set VT, leaks, and respiratory mechanics, none of the anesthesia ventilators were able to deliver a median measured VT within a 10% error. The bias between measured VT and set VT varied widely among ventilators (from 4.27 mL to -10.59 mL). Additionally, in the Apollo ventilator, PEEP was underdelivered with the largest leak value. CONCLUSIONS: Our results suggest that in comparison with the 2 neonatal ICU ventilators tested, the anesthesia ventilators did not greatly differ in terms of VT delivery in the presence of a gas leak.


Assuntos
Anestesia , Ventiladores Mecânicos , Recém-Nascido , Humanos , Volume de Ventilação Pulmonar , Pulmão , Unidades de Terapia Intensiva Neonatal
19.
Crit Care Explor ; 5(10): e0983, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37795456

RESUMO

OBJECTIVES: Experimental models suggest that prone position and positive end-expiratory pressure (PEEP) homogenize ventral-dorsal ventilation distribution and regional respiratory compliance. However, this response still needs confirmation on humans. Therefore, this study aimed to assess the changes in global and regional respiratory mechanics in supine and prone positions over a range of PEEP levels in acute respiratory distress syndrome (ARDS) patients. DESIGN: A prospective cohort study. PATIENTS: Twenty-two intubated patients with ARDS caused by COVID-19 pneumonia. INTERVENTIONS: Electrical impedance tomography and esophageal manometry were applied during PEEP titrations from 20 cm H2O to 6 cm H2O in supine and prone positions. MEASUREMENTS: Global respiratory system compliance (Crs), chest wall compliance, regional lung compliance, ventilation distribution in supine and prone positions. MAIN RESULTS: Compared with supine position, the maximum level of Crs changed after prone position in 59% of ARDS patients (n = 13), of which the Crs decreased in 32% (n = 7) and increased in 27% (n = 6). To reach maximum Crs after pronation, PEEP was changed in 45% of the patients by at least 4 cm H2O. After pronation, the ventilation and compliance of the dorsal region did not consistently change in the entire sample of patients, increasing specifically in a subgroup of patients who showed a positive change in Crs when transitioning from supine to prone position. These combined changes in ventilation and compliance suggest dorsal recruitment postpronation. In addition, the subgroup with increased Crs postpronation demonstrated the most pronounced difference between dorsal and ventral ventilation distribution from supine to prone position (p = 0.01), indicating heterogeneous ventilation distribution in prone position. CONCLUSIONS: Prone position modifies global respiratory compliance in most patients with ARDS. Only a subgroup of patients with a positive change in Crs postpronation presented a consistent improvement in dorsal ventilation and compliance. These data suggest that the response to pronation on global and regional mechanics can vary among ARDS patients, with some patients presenting more dorsal lung recruitment than others.

20.
J Clin Med ; 12(4)2023 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-36835785

RESUMO

(1) The use of high-flow nasal cannula (HFNC) combined with frequent respiratory monitoring in patients with acute hypoxic respiratory failure due to COVID-19 has been shown to reduce intubation and mechanical ventilation. (2) This prospective, single-center, observational study included consecutive adult patients with COVID-19 pneumonia treated with a high-flow nasal cannula. Hemodynamic parameters, respiratory rate, inspiratory fraction of oxygen (FiO2), saturation of oxygen (SpO2), and the ratio of oxygen saturation to respiratory rate (ROX) were recorded prior to treatment initiation and every 2 h for 24 h. A 6-month follow-up questionnaire was also conducted. (3) Over the study period, 153 of 187 patients were eligible for HFNC. Of these patients, 80% required intubation and 37% of the intubated patients died in hospital. Male sex (OR = 4.65; 95% CI [1.28; 20.6], p = 0.03) and higher BMI (OR = 2.63; 95% CI [1.14; 6.76], p = 0.03) were associated with an increased risk for new limitations at 6-months after hospital discharge. (4) 20% of patients who received HFNC did not require intubation and were discharged alive from the hospital. Male sex and higher BMI were associated with poor long-term functional outcomes.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa