Systematic review of vacuum assisted drainage in cardiopulmonary bypass, demonstrating its advantages and disadvantages, by case reports and evidence about its effects on microcirculation. We conducted a systematic search on the period 1997-2012, in the databases PubMed, Medline, Lilacs and SciELO. Of the 70 selected articles, 26 were included in the review. Although the vacuum assisted drainage has significant potential for complications and requires appropriate technology and professionalism, prevailed in literature reviewed the concept that vacuum assisted drainage contributed in reducing the rate of transfusions, hemodilutions, better operative field, no significant increase in hemolysis, reduced complications surgical, use of lower prime and of smaller diameter cannulas.
Assuntos
Ponte Cardiopulmonar/métodos , Drenagem/métodos , Ponte Cardiopulmonar/efeitos adversos , Drenagem/efeitos adversos , Humanos , Complicações Pós-Operatórias , Reprodutibilidade dos Testes , Medição de Risco , VácuoRESUMO
INTRODUCTION: Roller pumps play an important role in extracorporeal circulation. However, occlusion of the rollers should be adequately performed and this can be adjusted mainly by two methods: static and dynamic. OBJECTIVE: To investigate how the Brazilian perfusionists adjust arterial roller pumps in their services and evaluate the application of a Device to Assist Calibration (DAC) that facilitates roller adjustment by the dynamic calibration method. METHODS: We installed a roller pump with accessories to perform adjustment by drop rate (static calibration) and dynamic calibration methods during the XXVIII Brazilian Congress of Extracorporeal Circulation. Perfusionists were asked to adjust the roller pump according to the procedure they usually do in their service. After each adjustment pressure was measured by dynamic calibration method with DAC. The research was approved by the Research Ethics Committee of UNICAMP, Nº 1144/2010. RESULTS: There were 56 perfusionists in this study. Pressure average of 56 measurements of dynamic calibration was 434 ± 214 mmHg; 76% of measurements were within the recommended range for the use of the dynamic calibration method (between 150 and 500 mmHg). CONCLUSION: Brazilian perfusionists tend to adjust roller pumps with less occlusive settings. The amplitudes of the dynamic calibration pressure tend to be smaller for more experienced perfusionists because their skills increase with time. The device can be used by the perfusionist to adjust roller pumps with greater accuracy and mainly repeatability in few minutes.
Assuntos
Circulação Extracorpórea/instrumentação , Bombas de Infusão/normas , Adulto , Ocupações Relacionadas com Saúde , Calibragem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto JovemRESUMO
Revisão sistemática sobre drenagem assistida a vácuo na circulação extracorpórea, demonstrando seus benefícios, desvantagens, por relatos de casos e evidências sobre seus efeitos na microcirculação. Realizou-se pesquisa sistemática, no período de 1997-2012, nas bases de dados do PubMed-Medline, Lilacs e SciELO. Termos: "circulação extracorpórea", "vácuo", "drenagem", "cirurgia cardíaca" e suas correspondentes traduções, em condições variadas. Dos 70 artigos selecionados, 26 foram incluídos na revisão. Embora a drenagem assistida a vácuo possua potencial significante de complicações e exija tecnologia e profissionalismo respectivo adequado, prevaleceu na literatura revisada o conceito de que a drenagem assistida a vácuo contribuiu na redução no índice de transfusões, hemodiluições, melhor campo operatório, não aumento de hemólise significativa, redução de complicações pós-cirúrgicas, uso de menor prime e uso de cânulas de menor calibre.
Systematic review of vacuum assisted drainage in cardiopulmonary bypass, demonstrating its advantages and disadvantages, by case reports and evidence about its effects on microcirculation. We conducted a systematic search on the period 1997-2012, in the databases PubMed, Medline, Lilacs and SciELO. Of the 70 selected articles, 26 were included in the review. Although the vacuum assisted drainage has significant potential for complications and requires appropriate technology and professionalism, prevailed in literature reviewed the concept that vacuum assisted drainage contributed in reducing the rate of transfusions, hemodilutions, better operative field, no significant increase in hemolysis, reduced complications surgical, use of lower prime and of smaller diameter cannulas.
Assuntos
Humanos , Ponte Cardiopulmonar/métodos , Drenagem/métodos , Ponte Cardiopulmonar/efeitos adversos , Drenagem/efeitos adversos , Complicações Pós-Operatórias , Reprodutibilidade dos Testes , Medição de Risco , VácuoRESUMO
INTRODUÇÃO: Bombas de roletes desempenham um papel importante na circulação extracorpórea. No entanto, a oclusão dos roletes das bombas deve ser realizada de forma adequada e estas podem ser ajustadas, principalmente por dois métodos: estático e dinâmico. OBJETIVO: Investigar como os perfusionistas brasileiros ajustam as bombas de rolete arterial em seus serviços e testar o uso de um Dispositivo Auxiliar de Calibração que facilita o ajuste pelo método de calibração dinâmica. MÉTODOS: Foi instalada uma bomba de roletes com os acessórios necessários para a realização de sua calibração pelos métodos de velocidade de queda (calibração estática) e calibração dinâmica durante o XXVIII Congresso Brasileiro de Circulação Extracorpórea. Foi solicitado aos perfusionistas que ajustassem uma bomba de roletes conforme procedimento normalmente utilizado em seu serviço. Após cada regulagem, foi medida a respectiva pressão pelo método de calibração dinâmica com o auxílio do dispositivo. O projeto foi aprovado pelo Comitê de Ética em Pesquisa da UNICAMP, sob Nº 1144/2010. RESULTADOS: Participaram da pesquisa 56 perfusionistas. A média das 56 medidas de pressão de calibração dinâmica foi 434 ± 214 mmHg; 76 por cento das medidas realizadas ficaram no intervalo preconizado para o uso da técnica de calibração dinâmica (entre 150 e 500 mmHg). CONCLUSÃO: Os perfusionistas brasileiros tendem a calibrar bombas de roletes com ajustes menos oclusivos. As amplitudes das medidas de pressão de calibração dinâmica tendem a ser menores para perfusionistas mais experientes. O dispositivo pode ser utilizado por perfusionistas para ajustar bombas de roletes com maior precisão e, principalmente, repetitividade e em alguns minutos.
INTRODUCTION: Roller pumps play an important role in extracorporeal circulation. However, occlusion of the rollers should be adequately performed and this can be adjusted mainly by two methods: static and dynamic. OBJECTIVE: To investigate how the Brazilian perfusionists adjust arterial roller pumps in their services and evaluate the application of a Device to Assist Calibration (DAC) that facilitates roller adjustment by the dynamic calibration method. METHODS: We installed a roller pump with accessories to perform adjustment by drop rate (static calibration) and dynamic calibration methods during the XXVIII Brazilian Congress of Extracorporeal Circulation. Perfusionists were asked to adjust the roller pump according to the procedure they usually do in their service. After each adjustment pressure was measured by dynamic calibration method with DAC. The research was approved by the Research Ethics Committee of UNICAMP, Nº 1144/2010. RESULTS: There were 56 perfusionists in this study. Pressure average of 56 measurements of dynamic calibration was 434 ± 214 mmHg; 76 percent of measurements were within the recommended range for the use of the dynamic calibration method (between 150 and 500 mmHg). CONCLUSION: Brazilian perfusionists tend to adjust roller pumps with less occlusive settings. The amplitudes of the dynamic calibration pressure tend to be smaller for more experienced perfusionists because their skills increase with time. The device can be used by the perfusionist to adjust roller pumps with greater accuracy and mainly repeatability in few minutes.