Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Lancet Glob Health ; 12(6): e983-e994, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38762298

RESUMO

BACKGROUND: Early detection and diagnosis of acute rheumatic fever and rheumatic heart disease are key to preventing progression, and echocardiography has an important diagnostic role. Standard echocardiography might not be feasible in high-prevalence regions due to its high cost, complexity, and time requirement. Handheld echocardiography might be an easy-to-use, low-cost alternative, but its performance in screening for and diagnosing acute rheumatic fever and rheumatic heart disease needs further investigation. METHODS: In this systematic review and meta-analysis, we searched Embase, MEDLINE, LILACS, and Conference Proceedings Citation Index-Science up to Feb 9, 2024, for studies on the screening and diagnosis of acute rheumatic fever and rheumatic heart disease using handheld echocardiography (index test) or standard echocardiography or auscultation (reference tests) in high-prevalence areas. We included all studies with useable data in which the diagnostic performance of the index test was assessed against a reference test. Data on test accuracy in diagnosing rheumatic heart disease, acute rheumatic fever, or carditis with acute rheumatic fever (primary outcomes) were extracted from published articles or calculated, with authors contacted as necessary. Quality of evidence was appraised using GRADE and QUADAS-2 criteria. We summarised diagnostic accuracy statistics (including sensitivity and specificity) and estimated 95% CIs using a bivariate random-effects model (or univariate random-effects models for analyses including three or fewer studies). Area under the curve (AUC) was calculated from summary receiver operating characteristic curves. Heterogeneity was assessed by visual inspection of plots. This study was registered with PROSPERO (CRD42022344081). FINDINGS: Out of 4868 records we identified 11 studies, and two additional reports, comprising 15 578 unique participants. Pooled data showed that handheld echocardiography had high sensitivity (0·87 [95% CI 0·76-0·93]), specificity (0·98 [0·71-1·00]), and overall high accuracy (AUC 0·94 [0·84-1·00]) for diagnosing rheumatic heart disease when compared with standard echocardiography (two studies; moderate certainty of evidence), with better performance for diagnosing definite compared with borderline rheumatic heart disease. High sensitivity (0·79 [0·73-0·84]), specificity (0·85 [0·80-0·89]), and overall accuracy (AUC 0·90 [0·85-0·94]) for screening rheumatic heart disease was observed when pooling data of handheld echocardiography versus standard echocardiography (seven studies; high certainty of evidence). Most studies had a low risk of bias overall. Some heterogeneity was observed for sensitivity and specificity across studies, possibly driven by differences in the prevalence and severity of rheumatic heart disease, and level of training or expertise of non-expert operators. INTERPRETATION: Handheld echocardiography has a high accuracy and diagnostic performance when compared with standard echocardiography for diagnosing and screening of rheumatic heart disease in high-prevalence areas. FUNDING: World Health Organization. TRANSLATIONS: For the Chinese, French, Italian, Persian, Portuguese, Spanish and Urdu translations of the abstract see Supplementary Materials section.


Assuntos
Ecocardiografia , Cardiopatia Reumática , Humanos , Cardiopatia Reumática/diagnóstico por imagem , Ecocardiografia/estatística & dados numéricos , Ecocardiografia/métodos , Programas de Rastreamento/métodos , Organização Mundial da Saúde , Guias de Prática Clínica como Assunto , Sensibilidade e Especificidade
2.
Clin Rev Allergy Immunol ; 66(2): 223-240, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38696031

RESUMO

Secondary prevention with penicillin aims to prevent further episodes of acute rheumatic fever and subsequent development of rheumatic heart disease (RHD). Penicillin allergy, self-reported by 10% of the population, can affect secondary prevention programs. We aimed to assess the role for (i) routine penicillin allergy testing and the (ii) safety of penicillin allergy delabeling approaches in this context. We searched MEDLINE, Embase, CENTRAL, ClinicalTrials.gov, WHO ICTRP, ISRCTN, and CPCI-S to identify the relevant reports. We found 2419 records, but no studies addressed our initial question. Following advice from the WHO-Guideline committee and experts, we identified 6 manuscripts on allergy testing focusing on other populations showing that the prevalence of allergy confirmed by testing was low and the incidence of life-threatening reactions to BPG was very low (< 1-3/1000 individuals treated). A subsequent search addressed penicillin allergy delabeling. This found 516 records, and 5 studies addressing the safety of direct oral drug challenge vs. skin testing followed by drug administration in patients with suspected penicillin allergy. Immediate allergic reactions of minor severity were observed for a minority of patients and occurred less frequently in the direct drug challenge group: 2.3% vs. 11.5%; RR = 0.25, 95%CI 0.15-0.45, P < 0.00001, I2 = 0%. No anaphylaxis or deaths were observed. Severe allergic reactions to penicillin are extremely rare and can be recognized and dealt by trained healthcare workers. Confirmation of penicillin allergy diagnosis or delabeling using direct oral drug challenge or penicillin skin testing seems to be safe and is associated with a low rate of adverse reactions.


Assuntos
Hipersensibilidade a Drogas , Penicilinas , Guias de Prática Clínica como Assunto , Testes Cutâneos , Organização Mundial da Saúde , Humanos , Hipersensibilidade a Drogas/diagnóstico , Hipersensibilidade a Drogas/epidemiologia , Penicilinas/efeitos adversos , Antibacterianos/efeitos adversos
3.
Glob Heart ; 19(1): 39, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38681969

RESUMO

Background: Rheumatic Heart Disease (RHD) is the most common cause of valvular heart disease worldwide. Undiagnosed or untreated RHD can complicate pregnancy and lead to poor maternal and fetal outcomes and is a significant factor in non-obstetric morbidity. Echocardiography has an emerging role in screening for RHD. We aimed to critically analyse the evidence on the use of echocardiography for screening pregnant women for RHD in high-prevalence areas. Methods: We searched MEDLINE and Embase to identify the relevant reports. Two independent reviewers assessed the reports against the eligibility criteria in a double-blind process. Results: The searches (date: 4 April 2023) identified 432 records for screening. Ten non-controlled observational studies were identified, five using portable or handheld echocardiography, comprising data from 23,166 women. Prevalence of RHD varied across the studies, ranging from 0.4 to 6.6% (I2, heterogeneity >90%). Other cardiac abnormalities (e.g., congenital heart disease and left ventricular systolic dysfunction) were also detected <1% to 2% of cases. Certainty of evidence was very low. Conclusion: Echocardiography as part of antenatal care in high-prevalence areas may detect RHD or other cardiac abnormalities in asymptomatic pregnant women, potentially reducing the rates of disease progression and adverse labor-associated outcomes. However, this evidence is affected by the low certainty of evidence, and lack of studies comparing echocardiography versus standard antenatal care. Prospective Registration: PROSPERO 2022 July 4; CRD42022344081 Available from: https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=344081. Research question: 'In areas with a high prevalence of rheumatic heart disease, should handheld echocardiography be added to routine antenatal care?'


Assuntos
Ecocardiografia , Complicações Cardiovasculares na Gravidez , Cardiopatia Reumática , Humanos , Cardiopatia Reumática/epidemiologia , Cardiopatia Reumática/diagnóstico por imagem , Feminino , Gravidez , Ecocardiografia/métodos , Prevalência , Complicações Cardiovasculares na Gravidez/epidemiologia , Complicações Cardiovasculares na Gravidez/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Cuidado Pré-Natal/métodos
4.
Rev Port Cardiol ; 35(6): 351-8, 2016 Jun.
Artigo em Inglês, Português | MEDLINE | ID: mdl-27255172

RESUMO

INTRODUCTION: The incidence of cardiac implantable electronic device infections has increased significantly over the years and they are associated with significant morbidity and mortality. The epidemiology in the Central region of Portugal is not known. OBJECTIVE AND METHODS: To characterize cardiac implantable electronic device infections through a retrospective study of 3158 patients admitted to our center between January 2008 and September 2014 and to review the subject in the light of the current state of the art. RESULTS: The infection rate was 1.48% (pacemakers 1.21%, cardiac defibrillator/resynchronization devices 5.40%). The study population consisted of 47 patients with a mean age of 65±19 years, predominantly male (72.3%). Infections were mainly of pacemakers, the main device implanted in our population (n=2954), and most occurred late after first implantation. Clinically, most patients presented with fever and local inflammation. Blood cultures identified mainly Gram-positive microorganisms. Empiric antibiotic therapy with vancomycin was instituted in all patients, associated with gentamicin in 57%. The device was extracted in the majority of cases (72%). During follow-up (32±22 months) eight patients died (17%), seven of cardiovascular cause (15%), and seven were readmitted with device infection (15%). CONCLUSIONS: Our rate of infection was low, similar to other published series, with a higher rate in cardiac defibrillator/resynchronization devices. After standard treatment with antibiotic therapy and device extraction, the prognosis was good.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Portugal , Estudos Retrospectivos
5.
Rev Port Cardiol ; 34(9): 561.e1-3, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26300161

RESUMO

The authors describe a case of a rare complication occurring after cardiac surgery. Three weeks after aortic valve replacement a young male became hemodynamically unstable. The echocardiogram showed a large loculated hematoma compressing the right atrium. The patient was reoperated and the mass was removed. Recovery was complete.


Assuntos
Valva Aórtica/cirurgia , Cardiopatias/fisiopatologia , Implante de Prótese de Valva Cardíaca , Hematoma/fisiopatologia , Hemodinâmica , Complicações Pós-Operatórias/fisiopatologia , Adulto , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa