Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 253
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Pediatr ; 264: 113765, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37778410

RESUMO

OBJECTIVE: To describe the blood pressure outcomes of infants admitted to the neonatal intensive care unit (NICU) with idiopathic (nonsecondary) hypertension (HTN) who were discharged on antihypertensive therapy. STUDY DESIGN: Retrospective, multicenter study of 14 centers within the Pediatric Nephrology Research Consortium. We included all infants with a diagnosis of idiopathic HTN discharged from the NICU on antihypertensive treatment. The primary outcome was time to discontinuation of antihypertensive therapy, grouped into (≤6 months, >6 months to 1 year, and >1 year). Comparisons between groups were made with χ2 tests, Fisher's exact tests, and ANOVA. RESULTS: Data from 118 infants (66% male) were included. Calcium channel blockers were the most prescribed class of antihypertensives (56%) in the cohort. The percentages remaining on antihypertensives after NICU discharge were 60% at 6 months, 26% at 1 year, and 7% at 2 years. Antenatal steroid treatment was associated with decreased likelihood of antihypertensive therapy >1 year after discharge. CONCLUSIONS: This multicenter study reports that most infants admitted to the NICU diagnosed with idiopathic HTN will discontinue antihypertensive treatment by 2 years after NICU discharge. These data provide important insights into the outcome of neonatal HTN, but should be confirmed prospectively.


Assuntos
Hipertensão , Doenças do Recém-Nascido , Nefrologia , Gravidez , Recém-Nascido , Lactente , Criança , Humanos , Masculino , Feminino , Unidades de Terapia Intensiva Neonatal , Anti-Hipertensivos/uso terapêutico , Estudos Retrospectivos , Pressão Sanguínea , Hipertensão/diagnóstico , Hipertensão/tratamento farmacológico
2.
J Vasc Surg ; 72(2): 423-434.e1, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32081482

RESUMO

OBJECTIVE: The objective of this study was to review the learning curve for fenestrated-branched endovascular aortic repair (F-BEVAR) of pararenal and thoracoabdominal aortic aneurysms (TAAAs). METHODS: We reviewed the clinical data of 334 consecutive patients (255 males, mean age 75 ± 7 years) who underwent F-BEVAR between 2007 and 2016 in a single institution. Outcomes were analyzed in four quartiles of experience (Q1-Q4). Study outcomes included trends in patient characteristics, device design, procedural variables, 30-day mortality, and major adverse events (MAEs). RESULTS: There were 178 patients (53%) treated for pararenal aneurysms and 156 (47%) for TAAAs. During the study period, there was a statistically significant increase in the proportion of TAAAs and in the number of vessels incorporated. Despite this, there was a steady decrease in 30-day mortality (6% in Q1 to 0% in Q4; P < .04) and in the rate of MAEs (60% in Q1 to 29% in Q4; P<.001). By linear regression analysis, there was significant decline in estimated blood loss (1358 ± 1517 mL in Q1 to 486 ± 520 mL in Q4; P < .001), total operating time (325 ± 116 minutes in Q1 to 248 ± 92 minutes in Q4; P < .001), total fluoroscopy time (121 ± 59 minutes in Q1 to 85 ± 39 minutes in Q4; P < .001), contrast volume (201 ± 92 mL in Q1 to 160 ± 61 mL in Q4; P = .002), and radiation dose (4141 ± 2570 mGy in Q2 to 2543 ± 1895 mGy in Q4; P < .001). Independent predictors of MAEs were total operating time (odds ratio [OR], 1.6; 95% confidence interval [CI], 1.3-1.8; P < .001), Society for Vascular Surgery total score (OR, 1.1; 95% CI, 1.02-1.2; P = .009), and quartile 1 (OR, 3.0; 95% CI, 1.7-5.2; P < .001). CONCLUSIONS: This study demonstrates significant improvement in perioperative mortality, MAEs, procedural variables, and secondary interventions in patients treated by F-BEVAR, despite the increase in complexity of aneurysm pathology during the study period. Also, better patient selection contributed to improve outcomes.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular , Competência Clínica , Procedimentos Endovasculares , Curva de Aprendizado , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
3.
BMC Cardiovasc Disord ; 20(1): 274, 2020 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-32503490

RESUMO

BACKGROUND: Ventricular strain measurements vary depending on cardiac chamber (left ventricle [LV] or right ventricle [RV]), type of strain (longitudinal, circumferential, or radial), ventricular level (basal, mid, or apical), myocardial layer (endocardial or epicardial), and software used for analysis, among other demographic factors such as age and gender. Here, we present an analysis of ventricular strain taking all of these variables into account in a cohort of patients with no structural heart disease using a vendor-independent speckle-tracking software. METHODS: LV and RV full-thickness strain parameters were retrospectively measured in 102 patients (mean age 39 ± 15 years; 62% female). Within this cohort, we performed further layer-specific strain analysis in 20 subjects. Data were analyzed for global and segmental systolic strain, systolic strain rate, early diastolic strain rate, and their respective time-to-peak values. RESULTS: Mean LV global longitudinal, circumferential, and radial strain values for the entire cohort were - 18.4 ± 2.0%, - 22.1 ± 4.1%, and 43.9 ± 12.1% respectively, while mean RV global and free wall longitudinal strain values were - 24.2 ± 3.9% and - 26.1 ± 5.2% respectively. Women on average demonstrated higher longitudinal and circumferential strain and strain rate than men, and longer corresponding time-to-peak values. Longitudinal strain measurements were highest at the apex compared with the mid ventricle and base, and in the endocardium compared with the epicardium. Longitudinal strain was the most reproducible measure, followed closely by circumferential strain, while radial strain showed suboptimal reproducibility. CONCLUSIONS: We present an analysis of ventricular strain in patients with no structural heart disease using a vendor-independent speckle-tracking software.


Assuntos
Ecocardiografia , Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Função Ventricular Esquerda , Função Ventricular Direita , Adulto , Bases de Dados Factuais , Diástole , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Software , Sístole , Adulto Jovem
4.
Clin Infect Dis ; 68(6): 1024-1030, 2019 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-30084971

RESUMO

BACKGROUND: Tumor necrosis factor α inhibitors (TNFi) are commonly used to treat immune-mediated disorders, but they are associated with an increased risk of mycobacterial and fungal infections. We compared the outcomes of TNFi recipients screened for asymptomatic coccidioidomycosis with those of unscreened patients to compare the development of symptomatic coccidioidomycosis and to describe its outcomes for patients with abnormal coccidioidal screenings. METHODS: We searched electronic health records from 4 September 2010 through 26 September 2016 for all patients receiving a TNFi for dermatologic, rheumatologic, or gastroenterologic diagnoses, then categorized patients by whether or not they had undergone coccidioidal serologic testing for screening or diagnostic purposes. RESULTS: A total of 2793 patients had a TNFi prescribed. Of those, 1951 met the inclusion criteria: 1025/1951 (52.5%) never had coccidioidal screening; 925/1951 (47.4%) had serologic screening either before beginning TNFi therapy or annually, or both after beginning a TNFi. Symptomatic coccidioidomycosis developed in 35/1025 (3.4%) unscreened patients. Of those screened, 861/925 (93.1%) had negative serologic tests, of which 11/861 (1.3%) subsequently developed symptomatic coccidioidomycosis; 36/925 (3.9%) had coccidioidomycosis at screening (7, probable infection; 11, possible infection; 18, asymptomatic seropositive result); and 17 had only positive findings for immunoglobulin M antibodies and did not meet the definition for coccidioidomycosis. The unscreened cohort was more likely to have symptomatic coccidioidomycosis than the screened cohort (35/1025 vs 11/861, P < .01). CONCLUSIONS: Screening for asymptomatic coccidioidomycosis within a Coccidioides-endemic area allowed for identifying and managing asymptomatic coccidioidomycosis before patients began TNFi therapy. Less symptomatic infection developed in the screened than the unscreened cohort.


Assuntos
Coccidioidomicose/diagnóstico , Testes Sorológicos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Coccidioides , Coccidioidomicose/epidemiologia , Coccidioidomicose/etiologia , Gerenciamento Clínico , Feminino , Humanos , Masculino , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Avaliação de Resultados da Assistência ao Paciente , Radiografia , Testes Sorológicos/métodos , Avaliação de Sintomas , Inibidores do Fator de Necrose Tumoral/efeitos adversos , Inibidores do Fator de Necrose Tumoral/uso terapêutico , Adulto Jovem
5.
J Vasc Surg ; 69(4): 1045-1058.e3, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30527938

RESUMO

OBJECTIVE: The objective of this study was to analyze the impact of advanced imaging applications and cone beam computed tomography (CBCT) on radiation exposure of the patient and operator and detection of technical problems during fenestrated-branched endovascular aortic repair (F-BEVAR) for treatment of pararenal aneurysms and thoracoabdominal aortic aneurysms (TAAAs). METHODS: We reviewed the clinical data of 386 consecutives patients (289 male; mean age, 75 ± 8 years) treated by F-BEVAR for 196 pararenal aneurysms and 190 TAAAs (mean, 3.4 ± 0.9 targeted vessels/patient) between 2007 and 2017. Radiation exposure (cumulative air kerma) was analyzed in three fixed imaging systems used between 2007 and 2011 (system 1), 2012 and 2016 (system 2), and 2016 and 2017 (system 3). Onlay fusion and CBCT were available with systems 2 and 3, whereas digital zoom with fusion overlay was used with system 3. Operator effective dose was measured per month using a radiation dosimeter badge. Computed tomography angiography and CBCT were analyzed for findings requiring immediate revision or secondary interventions. End points were patient radiation exposure; operator effective dose; procedure technical success; and 30-day rates of mortality, major adverse events, and secondary interventions. RESULTS: F-BEVAR was performed using system 1 in 98 patients, system 2 in 198 patients, and system 3 in 90 patients. Use of onlay fusion/CBCT was 0% with system 1, 42% with system 2, and 98% with system 3. Procedures performed with onlay fusion/CBCT had significantly (P < .05) higher technical success (99.4% vs 98.8%) and lower contrast material volume (155 ± 58 mL vs 172 ± 80 mL), fluoroscopy time (83 ± 34 minutes vs 94 ± 49 minutes), and cumulative air kerma (2561 ± 1920 mGy vs 3767 ± 2307 mGy). Despite higher case volume and increasing complexity during the experience, operator effective dose decreased to 9 ± 4 × 10-2 mSv/case with system 3 compared with 26 ± 3 × 10-2 mSv/case with system 1 and 20 ± 2 × 10-2 mSv/case with system 2 (P = .001). Among 219 patients who had no CBCT, 18 (8%) had computed tomography angiography findings that prompted secondary interventions before dismissal. Conversely, among 167 patients who had CBCT, 14 patients (8%) had intraoperative CBCT findings requiring immediate revision, with no additional secondary interventions. Patients treated with onlay fusion/CBCT had significantly (P < .05) lower mortality (4% vs 1%), major adverse events (43% vs 19%), and secondary interventions (10% vs 4%) at 30 days. CONCLUSIONS: Radiation exposure and operator effective dose significantly decreased with evolution of F-BEVAR experience and use of advanced imaging applications such as onlay fusion and CBCT. CBCT allowed immediate assessment and identified intraoperative technical problems, leading to immediate revision and avoiding early secondary interventions.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Aortografia/métodos , Implante de Prótese Vascular , Angiografia por Tomografia Computadorizada , Tomografia Computadorizada de Feixe Cônico , Procedimentos Endovasculares , Exposição Ocupacional/prevenção & controle , Exposição à Radiação/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aortografia/efeitos adversos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Exposição Ocupacional/efeitos adversos , Valor Preditivo dos Testes , Desenho de Prótese , Doses de Radiação , Exposição à Radiação/efeitos adversos , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Stents , Resultado do Tratamento
6.
J Vasc Surg ; 69(3): 651-660.e4, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30154012

RESUMO

OBJECTIVE: Renal function deterioration is an important determinant of mortality in patients treated for complex aortic aneurysms. We have previously determined that catheter and guidewire manipulation in diseased aortas during fenestrated-branched endovascular aneurysm repair (F-BEVAR) is associated with risk of renal function deterioration. The aim of this study was to describe the impact of atherothrombotic aortic wall thrombus (AWT) on renal function deterioration among patients treated by F-BEVAR for pararenal and extent IV thoracoabdominal aortic aneurysms. METHODS: Clinical data of 212 patients treated for complex aortic aneurysms with F-BEVAR were entered into a prospectively maintained database (2007-2015). AWT was evaluated by computed tomography angiography using volumetric measurements in nonaneurysmal aortic segments. AWT was classified as mild, moderate, or severe using objective assessment of the number of affected segments, thrombus type, thickness, area, and circumference. Acute kidney injury (AKI) was defined using Risk, Injury, Failure, Loss of kidney function, and End-stage renal disease (RIFLE) criteria, and renal function deterioration was defined by a decline in estimated glomerular filtration rate (eGFR) >30% from baseline. Patient survival and renal outcomes were assessed at dismissal, at 6 to 8 weeks, at 6 months, and annually, including AKI, serum creatinine concentration, eGFR, chronic kidney disease stage, need for renal replacement therapy, and presence of kidney infarction. RESULTS: There were 169 male (80%) and 43 female (20%) patients with a mean age of 75 ± 7 years. Aneurysm extent was pararenal in 157 patients and extent IV thoracoabdominal aortic aneurysm in 55 patients. A total of 700 renal-mesenteric arteries were incorporated (3.1 ± 1 vessels/patient). AWT was classified as mild in 98 patients (46%), moderate in 75 (35%), and severe in 39 (19%). At 30 days, 45 patients (21%) developed AKI. Decline in eGFR and kidney infarction were associated with higher AWT volume index and severe AWT classification (P < .05). There was no association of AWT with 30-day mortality, which was 0.5% for the entire cohort. Mean follow-up was 29 ± 23 months. Freedom from renal function deterioration was 73% ± 6% for mild, 81% ± 6% for moderate, and 66% ± 8% for severe AWT patients at 3 years (P = .012) and 46% ± 9% and 82% ± 4% for those with or without AKI after the initial procedure (P < .001). Overall, 41 patients (19%) had progression of chronic kidney disease stage, but none of the patients required renal replacement therapy. Survival was 73% ± 5% for mild, 72% ± 6% for moderate, and 69% ± 10% for severe AWT patients at 3 years (P = .67). CONCLUSIONS: AWT is a significant predictor of AKI and continued decline in renal function after the initial F-BEVAR procedure. Longer follow-up time is needed to determine the actual impact of AWT on survival.


Assuntos
Injúria Renal Aguda/etiologia , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Taxa de Filtração Glomerular , Rim/fisiopatologia , Trombose/complicações , Injúria Renal Aguda/mortalidade , Injúria Renal Aguda/fisiopatologia , Injúria Renal Aguda/terapia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/mortalidade , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Bases de Dados Factuais , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Trombose/mortalidade , Fatores de Tempo , Resultado do Tratamento
7.
J Vasc Surg ; 69(3): 635-643, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30714569

RESUMO

OBJECTIVE: Upper extremity (UE) access is frequently used during fenestrated-branched endovascular aortic repair (F-BEVAR) to facilitate catheterization of downgoing vessels. Limitations include risk of cerebral embolization and of UE arterial or peripheral nerve injury. The aim of this study was to assess outcomes of F-BEVAR using UE access. METHODS: We reviewed the clinical data of 334 consecutive patients (74% males; mean age 75 ± 8 years) treated by F-BEVAR for thoracoabdominal aortic aneurysms or pararenal aortic aneurysms between 2007 and 2016. Patients who underwent F-BEVAR with an UE approach for catheterization of the renal and/or mesenteric arteries were included in the study. End points were technical success, mortality, and a composite of access-related complications including cerebral embolization (stroke/transient ischemic attack), peripheral nerve injury, and axillary-brachial arterial complications requiring intervention. RESULTS: There were 243 patients (73%) treated by F-BEVAR with UE access, including 147 patients (60%) with thoracoabdominal aortic aneurysms and 96 patients (40%) with pararenal aortic aneurysms. A total of 878 renal-mesenteric arteries were incorporated by fenestrations or branches with a mean of 3.6 ± 0.8 vessels per patient. All patients had surgical exposure of the brachial artery. The left side was selected in 228 (94%) and the right side in 15 (6%). The technical success of target vessel incorporation was achieved in 99% of patients (870 of 878). Arterial closure was performed using primary repair in 213 patients (88%) or bovine patch angioplasty in 29 (12%). Patch closure was required in 13% of patients (21 of 159) treated by 10- to 12F sheaths and 8% (7 of 83) of those who had 7- to 8F sheaths (P = .19). There were six deaths (2.5%) at 30 days or within the hospital stay, none owing to access-related complications. Major access-related complication occurred in eight patients (3%), with no difference between the 10- to 12F (6 of 159 [4%]) or 7- to 8F sheaths (2 of 83 [2%]; P = .45). Two patients (1%) had transient median nerve neuropraxia, which resolved within 1 year. One patient (0.5%) required surgical evacuation of an access site hematoma. There were no UE arterial pseudoaneurysms, occlusions, or distal embolizations. Five patients (2%) had strokes (three minor, two major), occurring more frequently with right side (2 of 15 [13%]) as compared with left-sided access (3 of 228 [1%]; P = .03). After a mean follow-up of 38 ± 15 months, there were no other access-related complications or reinterventions. CONCLUSIONS: UE arterial access with surgical exposure was associated with a low rate of complications in patients treated with F-BEVAR. Closure with patch angioplasty is frequently needed, but there were no arterial occlusions, pseudoaneurysms, or distal embolizations requiring secondary procedures.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Cateterismo Periférico/métodos , Procedimentos Endovasculares/métodos , Extremidade Superior/irrigação sanguínea , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Cateterismo Periférico/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
8.
J Vasc Surg ; 69(5): 1356-1366.e6, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30714570

RESUMO

OBJECTIVE: The objective of this study was to investigate changes in health-related quality of life (QOL) in patients treated for pararenal aortic aneurysms (PAAs) and thoracoabdominal aortic aneurysms (TAAAs) with fenestrated-branched endovascular aneurysm repair (F-BEVAR). METHODS: A total of 159 consecutive patients (70% male; mean age, 75 ± 7 years) were enrolled in a prospective, nonrandomized single-center study using manufactured F-BEVAR (2013-2016). All patients were observed for at least 12 months (mean follow-up time, 27 ± 12 months). Patients' health-related QOL was assessed using the 36-Item Short Form Health Survey questionnaire at baseline (N = 159), 6 to 8 weeks (n = 136), 6 months (n = 129), and 12 months (n = 123). Physical component scores (PCSs) and mental component scores (MCSs) were compared with historical results of patients enrolled in the endovascular aneurysm repair (EVAR) 1 trial who were treated by standard EVAR for simple infrarenal abdominal aortic aneurysms. RESULTS: There were 57 patients with PAAs and 102 patients with TAAAs (50 extent IV and 52 extent I-III TAAAs). There were no 30-day deaths, in-hospital deaths, conversions to open surgery, or aorta-related deaths. Survival was 96% at 1 year and 87% at 2 years. Major adverse events occurred in 18% of patients, and 1-year reintervention rate was 14%. There were no statistically significant differences between the groups in 30-day outcomes. Patients treated for TAAAs had lower baseline scores compared with those treated for PAAs (P < .05). PCS declined significantly 6 to 8 weeks after F-BEVAR in both groups and returned to baseline values at 12 months in the PAA group but not in the TAAA group. Patients with TAAAs had significantly lower PCSs at 12 months compared with those with PAAs (P < .001). There was no decline in mean MCS. Major adverse events were associated with decline in PCS assessed at 6 to 8 weeks (P = .021) but not in the subsequent evaluations. Reinterventions had no effect on PCS or MCS. Overall, patients treated by F-BEVAR had similar changes in QOL measures as those who underwent standard EVAR in the EVAR 1 trial, except for lower PCS in TAAA patients at 12 months. CONCLUSIONS: Patients treated for TAAAs had lower scores at baseline in their physical aspect of health-related QOL. F-BEVAR was associated with significant decline in PCSs in both groups, which improved after 2 months and returned to baseline values at 12 months in patients with PAAs but not in those with TAAAs. Patients treated for PAAs had similar changes in QOL compared with those treated for infrarenal aortic aneurysms with standard EVAR.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Qualidade de Vida , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/mortalidade , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Nível de Saúde , Humanos , Masculino , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
9.
J Vasc Surg ; 70(1): 31-42.e7, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30583902

RESUMO

OBJECTIVE: The purpose of this study was to review treatment trends and outcomes of patients who underwent fenestrated-branched endovascular aneurysm repair (F-BEVAR) of pararenal aneurysms (PRAs) or thoracoabdominal aortic aneurysms (TAAAs) using physician-modified endografts (PMEGs) or company-manufactured devices (CMDs). METHODS: We reviewed the clinical data of 316 consecutive patients (242 male patients; mean age, 75 ± 8 years) who underwent F-BEVAR between 2007 and 2016. F-BEVAR was performed under two prospective investigational device exemption protocols since 2013. End points were mortality, major adverse events (MAEs), patient survival, reintervention, branch instability, aneurysm-related mortality, renal function deterioration, and target vessel patency. RESULTS: There were 145 patients (46%) treated by PMEGs (84 PRAs, 26 extent IV and 35 extent I-III TAAAs) and 171 patients (54%) who had CMDs (88 PRAs, 42 extent IV and 41 extent I-III TAAAs). Choice of endograft evolved from PMEGs in 131 patients (83%) treated in the first half of experience to CMDs in 144 patients (91%) treated in the second half of experience (P < .001). Patients treated by PMEGs had significantly (P < .05) larger aneurysms, more chronic pulmonary and kidney disease, and higher comorbidity severity scores. A total of 1081 renal-mesenteric arteries were targeted in both groups. Technical success was lower for PMEGs (98% vs 99.5%; P = .02). Thirty-day mortality was 5.5% for PMEGs (PRAs, 1.2%; extent IV 3.8% and extent I-III, 17.1%) and 0% for CMDs (P = .0018). Patients treated by PMEGs had significantly more (P < .001) MAEs (48% vs 23%) and longer hospital stay (9 ± 10 days vs 6 ± 6 days; P = .001). Mean follow-up was significantly longer for patients treated by PMEGs (38 ± 26 months vs 14 ± 12 months; P < .001). At 3 years, patient survival (68% ± 4% vs 67% ± 8%; P = .11), freedom from reintervention (68% ± 4% vs 68% ± 8%; P = .17), primary (94% ± 2% vs 92% ± 2%; P = .64) and secondary target vessel patency (98% ± 1% vs 98% ± 1%; P = .89), and freedom from renal function deterioration (75% ± 4% vs 65% ± 6%; P = .24) were similar for patients treated by PMEGs or CMDs, respectively. CONCLUSIONS: Choice of F-BEVAR evolved from PMEGs to almost exclusively CMDs under physician-sponsored investigational device exemption protocols. PMEG patients had more comorbidities and larger aneurysms. CMDs were performed with higher technical success, no mortality, and fewer MAEs.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/tendências , Prótese Vascular/tendências , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/tendências , Papel do Médico , Desenho de Prótese/tendências , Stents/tendências , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Comorbidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Intervalo Livre de Progressão , Retratamento/tendências , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
10.
Echocardiography ; 36(5): 877-887, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30985965

RESUMO

OBJECTIVE: To evaluate whether global peak systolic strain (PSS) and peak systolic strain rate (PSSR) derived from velocity vector imaging (VVI) allow early recognition of regional and global right ventricular (RV) dysfunction and the impact of this on left ventricular (LV) function in patients with pulmonary hypertension (PHT). BACKGROUND: RV function is an important determinant of prognosis in patients with heart failure, pulmonary hypertension, heart transplant, and congenital heart diseases. However, evaluation of the right ventricle is often limited by its complex geometry and inadequate visualization of RV free wall. Furthermore, the impact of RV dysfunction on the LV function is not well elucidated. METHODS: Ninety-nine participants, 35 control patients with normal RV systolic pressure (RVSP) (<30 mm Hg) and 64 patients with PHT (25 with mild-to-moderate increase in RVSP [≥36 and <60 mm Hg] and 39 with severe increase in RVSP [≥60 mm Hg]), underwent comprehensive echo-Doppler assessment and velocity vector imaging (VVI) for strain rate analysis. RV regional peak systolic and diastolic tangential velocity, strain, and strain rate were obtained from the basal, mid and apical segments of the RV free wall and interventricular septum (IVS) from apical 4-chamber view at end-expiration. Similar data were obtained from eighteen LV segments from apical 4-chamber, 2-chamber, and long-axis views. RESULTS: Peak systolic strain, strain rate, and tangential velocity at all segments in the RV free wall and IVS were decreased compared to controls in patients with PHT (P < 0.001). Significant correlation (r > 0.60; P < 0.001) was noted between RVSP and systolic and diastolic strain and strain rate at basal segment in IVS and global RV function. Peak early diastolic strain rate at all segments was also decreased in PHT patients compared with control patients (P < 0.01). Furthermore, RV systolic and diastolic strain and strain rate were lower in group 2 with mild-to-moderate hypertension while the conventional echo parameters were normal. Except for IVS segments, other LV segments had no statistical differences in systolic and diastolic velocity, strain, and strain rate compared to controls. However, they were lower than the published normal range. CONCLUSIONS: Strain and strain rate derived from VVI demonstrates early recognition of systolic and diastolic RV dysfunction in patients with PHT compared to controls. PHT is associated with global and regional RV systolic and diastolic dysfunction. Systolic and diastolic strain and strain rate from LV was lower compared to controls but were not statistically significant. This may indicate subclinical LV dysfunction in these patients, suggesting that conventional LV function parameters may not be sensitive to recognize subclinical LV dysfunction.


Assuntos
Ecocardiografia/métodos , Hipertensão Pulmonar/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/fisiopatologia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Hipertensão Pulmonar/complicações , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Direita/complicações
11.
Acta Cardiol ; 74(1): 53-58, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29513133

RESUMO

INTRODUCTION: Risk assessment for sudden cardiac death (SCD) in hypertrophic cardiomyopathy (HCM) remains complex. The goal of this study was to assess electrocardiogram (ECG)-derived risk factors on SCD in a large HCM population Methods: Retrospective review of adults with HCM evaluated at Mayo Clinic, Rochester, MN from 1 December 2002 to 31 December 2012 was performed. Data inclusive of ECG and 24-hour ambulatory Holter monitor were assessed. SCD events were documented by ventricular fibrillation (VF) noted on implantable cardioverter defibrillator (ICD), or appropriate VT or VF-terminating ICD shock. RESULTS: Overall, 1615 patients (mean age 53.7 ± 15.2 years; 943 males, 58.4%) were assessed, with mean follow-up 2.46 years and 110 SCD events. Via logistic regression (n = 820), the odds of SCD increased with increasing number of conventional risk factors. With one risk factor the OR was 4.88 (p < .0001; CI 2.22-10.74), two risk factors the OR was 6.922 (p < .0001; CI 2.94-16.28) and three or more risk factors, the OR was 13.997 (p < .0001; CI 5.649-34.68). Adding QTc > 450 to this logistic regression model had OR 1.722 (p = .04, CI 1.01-2.937) to predict SCD. QTc ≥ 450 was a significant predictor for death (HR 1.88, p = .021, CI 1.10-3.20). There was no correlation between sinus bradycardia, sinus tachycardia, first degree AV block, atrial fibrillation, left bundle branch block, right bundle branch block, premature atrial complexes, premature ventricular complexes, supraventricular tachycardia, PR interval, QRS interval and SCD. CONCLUSIONS: Prolonged QTc was a risk factor for SCD and death even when controlling for typical risk factors.


Assuntos
Cardiomiopatia Hipertrófica/complicações , Morte Súbita Cardíaca/etiologia , Previsões , Síndrome do QT Longo/etiologia , Medição de Risco/métodos , Idoso , Cardiomiopatia Hipertrófica/fisiopatologia , Morte Súbita Cardíaca/epidemiologia , Eletrocardiografia Ambulatorial , Feminino , Seguimentos , Humanos , Incidência , Síndrome do QT Longo/epidemiologia , Síndrome do QT Longo/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia
12.
Indian J Urol ; 35(3): 208-212, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31367072

RESUMO

INTRODUCTION: The objective was to analyze the diagnostic value of multiparametric magnetic resonance imaging (MRI) prostate lesion volume (PLV) and its correlation with the subsequent MRI-ultrasound (MRI-US) fusion biopsy results. MATERIALS AND METHODS: Between March 2014 and July 2016, 150 men underwent MRI-US fusion biopsies at our institution. All suspicious prostate lesions were graded according to the Prostate Imaging Reporting and Data System (PIRADS) and their volumes were measured. These lesions were subsequently biopsied. All data were prospectively collected and retrospectively analyzed. The PLV of all suspicious lesions was correlated with the presence of cancer on the final MRI-US fusion biopsy. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. RESULTS: There were 206 suspicious lesions identified in 150 men. The overall cancer detection rate was 102/206 (49.5%). The mean PLV for benign lesions was 0.63 ± 0.94 cm3 versus 1.44 ± 1.76 cm3 for cancerous lesions (P < 0.01). There was a statistically significant difference between the PLV of PIRADS 5 lesions when compared to PIRADS 4, 3, and 2 lesions (P < 0.0001, < 0.0001, and 0.006, respectively). The area under the curve for volume in predicting prostate cancer (PCa) was 0.66. The optimal volume for predicting PCa was 0.26 cm3 with a sensitivity, specificity, PPV, and NPV of 80.7%, 42.7%, 41.2%, and 74.6%, respectively. CONCLUSION: PLV may serve as a useful measure to triage patients prior to MRI-US fusion biopsy and help better understand the limits of this technology for individual patients.

13.
Circulation ; 135(4): 366-378, 2017 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-27903589

RESUMO

BACKGROUND: Prophylactic exclusion of the left atrial appendage (LAA) is often performed during cardiac surgery ostensibly to reduce the risk of stroke. However, the clinical impact of LAA closure in humans remains inconclusive. METHODS: Of 10 633 adults who underwent coronary artery bypass grafting and valve surgery between January 2000 and December 2005, 9792 patients with complete baseline characteristics, surgery procedure, and follow-up data were included in this analysis. A propensity score-matching analysis based on 28 pretreatment covariates was performed and 461 matching pairs were derived and analyzed to estimate the association of LAA closure with early postoperative atrial fibrillation (POAF) (atrial fibrillation ≤30 days of surgery), ischemic stroke, and mortality. RESULTS: In the propensity-matched cohort, the overall incidence of POAF was 53.9%. In this group, the rate of early POAF among the patients who underwent LAA closure was 68.6% versus 31.9% for those who did not undergo the procedure (P<0.001). LAA closure was independently associated with an increased risk of early POAF (adjusted odds ratio, 3.88; 95% confidence interval, 2.89-5.20), but did not significantly influence the risk of stroke (adjusted hazard ratio, 1.07; 95% confidence interval, 0.72-1.58) or mortality (adjusted hazard ratio, 0.92; 95% confidence interval, 0.75-1.13). CONCLUSIONS: After adjustment for treatment allocation bias, LAA closure during routine cardiac surgery was significantly associated with an increased risk of early POAF, but it did not influence the risk of stroke or mortality. It remains uncertain whether prophylactic exclusion of the LAA is warranted for stroke prevention during non-atrial fibrillation-related cardiac surgery.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Acidente Vascular Cerebral/etiologia , Idoso , Fibrilação Atrial/fisiopatologia , Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos Cirúrgicos Cardíacos/mortalidade , Estudos de Coortes , Feminino , Humanos , Masculino , Acidente Vascular Cerebral/fisiopatologia , Análise de Sobrevida
14.
J Vasc Surg ; 67(3): 713-721, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29122422

RESUMO

OBJECTIVE: The objective of this study was to compare outcomes after repair of type III and type IV thoracoabdominal aortic aneurysms (TAAAs) by three different open surgical techniques at a tertiary care institution. METHODS: Consecutive patients who underwent elective repair of type III and type IV TAAAs at our institution between 1999 and 2011 were retrospectively reviewed. Patients were divided into three groups according to surgical technique: clamp and sew (CS), left-sided heart bypass (LHB), and visceral branching (VB) followed by aortic reconstruction. Primary end points were early mortality and complications; secondary end points were need for blood transfusion, duration of operation, and long-term survival. RESULTS: Between 1999 and 2011, there were 121 consecutive patients (83 men, 38 women) with 52 type III and 69 type IV TAAAs who underwent elective repair (CS, 65 patients; LHB, 31 patients; VB, 25 patients). Perioperative spinal drainage was used in 84%. Procedure duration was longest in the VB group (mean, 9.1 hours vs 7.7 hours and 5.7 hours for CS and LHB; P < .001), but transfusion requirement was largest in the LHB group (mean, 3.5 L vs 1.7 L and 2.1 L for CS and VB; P = .015). Mean duration of mesenteric ischemia was significantly shorter in the VB group vs CS and LHB (18 minutes vs 35 minutes for CS and 30 minutes for LHB; P < .0001). Mean intensive care unit and hospital stays were the same (9, 10, and 8 days [P = .82]; 18, 20, and 18 days [P = .76]). Overall 30-day mortality was 6.6%, not different between groups (6%, 10%, and 4%; P = .68). Mean follow-up was 45 ± 42 months, and actuarial overall survival at 3 and 5 years was 70% and 64%, with no difference between groups (P = .36). CONCLUSIONS: For repair of type III and type IV TAAAs, the sequential VB technique has the longest duration, but it has the advantage of the shortest mesenteric and visceral ischemia times without improvement in early outcomes. Irrespective of the techniques used, complications, early mortality, risk of spinal cord injury, and survival were the same.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Minnesota , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento
15.
BMC Cancer ; 18(1): 1037, 2018 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-30359235

RESUMO

BACKGROUND: Combined anthracycline-trastuzumab chemotherapy has been associated with LV dysfunction. We aimed to assess early changes in left ventricular (LV) and right ventricular (RV) mechanics associated with combined anthracycline-trastuzumab treatment for breast cancer. As well as explore whether early changes in 2-dimensional (2D)-speckle tracking echocardiography (STE) could predict later chemotherapy-induced cardiotoxicity. METHODS: Sixty-six patients with breast cancer who received anthracycline-trastuzumab treatment were included (mean [±SD] age, 52 [9] years). Echocardiograms were available for analysis with 2D-STE at the following time points: pretreatment (T0), first cycle (T1), and second cycle (T2) of combined chemotherapy. All patients had a normal pretreatment LV ejection fraction (LVEF). Cardiotoxicity was defined as a decrease in LVEF of at least 10 percentage points from baseline on follow-up echocardiography. RESULTS: Cardiotoxicity developed in 13 of the 66 patients (20%). The mean (±SD) LVEF at T0 was 66% (±6); at T1 60% (±7); and at T2, 54% (±6). For the 53 patients without cardiotoxicity, the LVEF was 65% (±4%) at T0, 63% (±5%) at T1, and 62% (±4) at T2. Global longitudinal strain (GLS) at T1 was the strongest indicator of subsequent cardiotoxicity (area under the curve, 0.85; cutoff value, - 14.06; sensitivity, 91%; specificity, 83%; P = .003). Compared with baseline (T0), left ventricular longitudinal strain, LV circumferential strain, circumferential peak systolic strain rate (SR), circumferential peak early diastolic SR, right ventricular longitudinal strain, and longitudinal peak systolic SR at T1 and T2 were reduced significantly in patients with cardiotoxicity (P < .05). CONCLUSIONS: Anthracycline-trastuzumab treatment leads to early deterioration of LV GLS, circumferential strain, and systolic SR. Right ventricular GLS and SR were also affected. Early changes in GLS are good predictors of subsequent development of anthracycline-trastuzumab-induced cardiotoxicity.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Neoplasias da Mama/complicações , Cardiotoxicidade/diagnóstico , Cardiotoxicidade/etiologia , Ecocardiografia , Cardiopatias/diagnóstico , Cardiopatias/etiologia , Adulto , Idoso , Antraciclinas/administração & dosagem , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias da Mama/tratamento farmacológico , Ecocardiografia/métodos , Feminino , Testes de Função Cardíaca , Humanos , Pessoa de Meia-Idade , Prognóstico , Curva ROC , Reprodutibilidade dos Testes , Fatores de Risco , Índice de Gravidade de Doença , Trastuzumab/administração & dosagem , Disfunção Ventricular Esquerda
16.
Am J Nephrol ; 48(4): 242-250, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30235441

RESUMO

BACKGROUND: We evaluated the role of increased cardiac troponin T (cTnT), vascular, and cardiac diseases in predicting 5 and 10-year all-cause mortality after kidney transplantation. METHODS: We reviewed a cohort of 764 kidney transplant recipients and analyzed pertinent cardiovascular risk factors at the time of transplant evaluation. Proportional hazards regression analysis with bootstrapping method was utilized to provide a risk stratification score for mortality. RESULTS: Mean age was 58.8 years (SD 12.1) and median follow-up was 7.0 years (range 1 day to 18.0 years). Fifty-four percent of patients (n = 415) had cTnT measured (median 0.02 ng/mL, range 0.01-4.91). Fifty-three percent (n = 407) had vascular disease, 59% (n = 448) had diabetes, and 44% (n = 336) had cardiac disease pre-transplant. Sixty percent (n = 460) required dialysis. Older age, increased cTnT, pre-transplant vascular and cardiac diseases predicted mortality in multivariate analysis. We derived 2 scoring systems with and without cTnT - the ACV and ACTV scores (age, cardiac disease, elevated cTnT, and vascular disease) - as predictors of mortality after kidney transplant. Point assignments were: age 60-69 years (1), age ≥70 years (2), cardiac disease (1), cTnT ≥0.04 ng/mL (1), and vascular disease (1). Both scoring systems significantly predicted mortality. The ACTV score better delineated risk stratification across score levels (0-2, 3-4, and 5 points). CONCLUSIONS: We developed a risk schema predictive of all-cause mortality after kidney transplant in a derivation cohort. The ACTV score, including an elevated cTnT, provided superior prediction compared to a scoring system without cTnT. Further studies to validate these findings are needed.


Assuntos
Doenças Cardiovasculares/epidemiologia , Falência Renal Crônica/mortalidade , Transplante de Rim , Seleção de Pacientes , Troponina T/sangue , Idoso , Biomarcadores/sangue , Doenças Cardiovasculares/sangue , Comorbidade , Feminino , Seguimentos , Humanos , Falência Renal Crônica/sangue , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Período Pré-Operatório , Modelos de Riscos Proporcionais , Diálise Renal/estatística & dados numéricos , Estudos Retrospectivos , Medição de Risco/métodos , Fatores de Risco , Análise de Sobrevida , Transplantados/estatística & dados numéricos
17.
J Ultrasound Med ; 37(1): 217-224, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28741721

RESUMO

OBJECTIVES: Left ventricular (LV) septal hypertrophy in aortic stenosis raises diagnostic and therapeutic questions. However, the etiology and clinical consequences of this finding have not been well studied. The aim of this study was to perform a morphologic evaluation of the LV in aortic stenosis and to investigate the contributing factors and consequences of septal hypertrophy. METHODS: Patients with moderate or severe aortic stenosis were prospectively enrolled. Patients with previous myocardial infarction, wall motion abnormalities, at least moderate valvular regurgitation, known cardiomyopathy, an LV ejection fraction of less than 50%, and age younger than 65 years were excluded. RESULTS: Forty-one patients underwent a final analysis. Septal hypertrophy (LV septal wall thickness ≥15 mm) was confirmed in 21 of 41 patients. The septal hypertrophy group had higher peak aortic valve velocity, a higher diabetes mellitus rate, and a higher rate and longer duration of hypertension than those without septal hypertrophy. The peak aortic valve velocity (odds ratio, 7.1; 95% confidence interval, 1.4-37.1) and diabetes mellitus (odds ratio, 7.4; 95% confidence interval, 1.2-46.2) were the significant factors associated with septal hypertrophy by multivariate analysis. Intraventricular conduction disturbance on electrocardiography was more frequent in the septal hypertrophy group (P = .021). CONCLUSIONS: Left ventricular septal hypertrophy was commonly observed in elderly patients with aortic stenosis, and a higher aortic valve velocity, hypertension, and diabetes mellitus were associated factors. Intraventricular conduction disturbance occurred more often in patients with septal hypertrophy than those without, which implies the pathophysiologic consequence. Further studies are needed to determine the impact of septal hypertrophy and intraventricular conduction disturbance on the prognosis of patients after aortic valve interventions.


Assuntos
Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/fisiopatologia , Eletrocardiografia/métodos , Avaliação Geriátrica/métodos , Hipertrofia Ventricular Esquerda/complicações , Hipertrofia Ventricular Esquerda/fisiopatologia , Idoso , Estenose da Valva Aórtica/diagnóstico por imagem , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Masculino , Estudos Prospectivos
18.
J Emerg Med ; 54(5): 702-710.e1, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29454714

RESUMO

BACKGROUND: Emergency physicians differ in many ways with respect to practice. One area in which interphysician practice differences are not well characterized is emergency department (ED) length of stay (LOS). OBJECTIVE: To describe how ED LOS differs among physicians. METHODS: We performed a 3-year, five-ED retrospective study of non-fast-track visits evaluated primarily by physicians. We report each provider's observed LOS, as well as each provider's ratio of observed LOS/expected LOS (LOSO/E); we determined expected LOS based on site average adjusted for the patient characteristics of age, gender, acuity, and disposition status, as well as the time characteristics of shift, day of week, season, and calendar year. RESULTS: Three hundred twenty-seven thousand, seven hundred fifty-three visits seen by 92 physicians were eligible for analysis. For the five sites, the average shortest observed LOS was 151 min (range 106-184 min), and the average longest observed LOS was 232 min (range 196-270 min); the average difference was 81 min (range 69-90 min). For LOSO/E, the average lowest LOSO/E was 0.801 (range 0.702-0.887), and the average highest LOSO/E was 1.210 (range 1.186-1.275); the average difference between the lowest LOSO/E and the highest LOSO/E was 0.409 (range 0.305-0.493). CONCLUSION: There are significant differences in ED LOS at the level of the individual physician, even after accounting for multiple confounders. We found that the LOSO/E for physicians with the lowest LOSO/E at each site averaged approximately 20% less than predicted, and that the LOSO/E for physicians with the highest LOSO/E at each site averaged approximately 20% more than predicted.


Assuntos
Medicina de Emergência/métodos , Serviço Hospitalar de Emergência/estatística & dados numéricos , Tempo de Internação/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Fatores de Tempo , Serviço Hospitalar de Emergência/organização & administração , Humanos , Estudos Retrospectivos
19.
J Vasc Surg ; 66(5): 1321-1333, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28596039

RESUMO

OBJECTIVE: The goal of this study was to investigate the correlation between atherothrombotic aortic wall thrombus (AWT) and clinical outcomes in patients treated by fenestrated-branched endovascular aortic repair (F-BEVAR) and present a new classification system for assessment of AWT burden. METHODS: The clinical data of 301 patients treated for pararenal and thoracoabdominal aortic aneurysms (TAAAs) by F-BEVAR was reviewed. The study excluded 89 patients with extent I to III TAAA because of extensive laminated thrombus within the aneurysm sac. Computed tomography angiograms were analyzed in all patients to determine the location, extent, and severity of atherothrombotic AWT. The aorta was divided into three segments: ascending and arch (A), thoracic (B) and renal-mesenteric (C). Volumetric measurements (cm3) of AWT were performed using TeraRecon software (TeraRecon Inc, Foster City, Calif). These volumes were used to create an AWT index by dividing the AWT volume from the total aortic volume. A classification system was proposed using objective assessment of the number of affected segments, thrombus type, thickness, area, and circumference. Clinical outcomes included 30-day mortality, neurologic and gastrointestinal complications, renal events (Risk, Injury, Failure, Loss of kidney function, End-stage renal disease [RIFLE]), and solid organ infarction. RESULTS: The study included 212 patients, 169 men (80%) and 43 women (20%), with a mean age of 76 ± 7 years. A total of 700 renal-mesenteric arteries were incorporated (3.1 ± 1 vessels/patient). AWT was classified as mild in 98 patients (46%) and was considered moderate or severe in 114 (54%). There was one death (0.5%) at 30 days. Solid organ infarction was present in 50 patients (24%), and acute kidney injury occurred in 45 patients (21%) by RIFLE criteria. An association with higher AWT indices was found for time to resume enteral diet (P = .0004) and decline in renal function (P = .0003). Patients with acute kidney injury 2 by RIFLE criterion had significantly higher (P = .002) AWT index scores in segment B. Spinal cord injury occurred in three patients (1.4%) and stroke in four (1.9%), but were not associated with the AWT index. Severity of AWT using the new proposed classification system correlated with the AWT index in all three segments (P < .001). Any of the end points occurred in 35% of the patients with mild and in 53% of those with moderate or severe AWT (P = .016). CONCLUSIONS: AWT predicts solid organ infarction, renal function deterioration, and longer time to resume enteral diet after F-BEVAR of pararenal and type IV TAAAs. Evaluation of AWT should be part of preoperative planning and decision making for selection of the ideal method of treatment in these patients.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Aortografia/métodos , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Stents , Trombose/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Embolia/etiologia , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Rim/fisiopatologia , Nefropatias/etiologia , Nefropatias/fisiopatologia , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Fatores de Risco , Trombose/classificação , Trombose/complicações , Fatores de Tempo , Resultado do Tratamento
20.
J Vasc Surg ; 65(5): 1249-1259.e10, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27986479

RESUMO

PURPOSE: To investigate outcomes of manufactured fenestrated and branched endovascular aortic repair (F-BEVAR) endografts based on supraceliac sealing zones to treat pararenal aortic aneurysms and thoracoabdominal aortic aneurysms (TAAAs). METHODS: A total of 127 patients (91 male; mean age, 75 ± 10 years old) were enrolled in a prospective, nonrandomized single-center study using manufactured F-BEVAR (November 2013-March 2015). Stent design was based on supraceliac sealing zone in all patients with ≥ four vessels in 111 (89%). Follow-up included clinical examination, laboratory studies, duplex ultrasound, and computed tomography imaging at discharge, 1 month, 6 months, and yearly. End points adjudicated by independent clinical event committee included mortality, major adverse events (any mortality, myocardial infarction, stroke, paraplegia, acute kidney injury, respiratory failure, bowel ischemia, blood loss >1 L), freedom from reintervention, and branch-related instability (occlusion, stenosis, endoleak or disconnection requiring reintervention), target vessel patency, sac aneurysm enlargement, and aneurysm rupture. RESULTS: There were 47 pararenal, 42 type IV, and 38 type I-III TAAAs with mean diameter of 59 ± 17 mm. A total of 496 renal-mesenteric arteries were incorporated by 352 fenestrations, 125 directional branches, and 19 celiac scallops, with a mean of 3.9 ± 0.5 vessels per patient. Technical success of target vessel incorporation was 99.6% (n = 493/496). There were no 30-day or in-hospital deaths, dialysis, ruptures or conversions to open surgical repair. Major adverse events occurred in 27 patients (21%). Paraplegia occurred in two patients (one type IV, one type II TAAAs). Follow-up was >30 days in all patients, >6 months in 79, and >12 months in 34. No patients were lost to follow-up. After a mean follow-up of 9.2 ± 7 months, 23 patients (18%) had reinterventions (15 aortic, 8 nonaortic), 4 renal artery stents were occluded, five patients had type Ia or III endoleaks, and none had aneurysm sac enlargement. Primary and secondary target vessel patency was 96% ± 1% and 98% ± 0.7% at 1 year. Freedom from any branch instability and any reintervention was 93% ± 2% and 93% ± 2% at 1 year, respectively. Patient survival was 96% ± 2% at 1 year for the entire cohort. CONCLUSIONS: Endovascular repair of pararenal aortic aneurysms and TAAAs, using manufactured F-BEVAR with supraceliac sealing zones, is safe and efficacious. Long-term follow-up is needed to assess the impact of four-vessel designs on device-related complications and progression of aortic disease.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Minnesota , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Retratamento , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Dupla , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa