Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38841916

RESUMO

BACKGROUND: Residual transprosthetic gradient (TG) after transcatheter aortic valve replacement (TAVR) with balloon-expandable valves (BEV) may be due to suboptimal valve expansion. AIMS: To compare hemodynamics after TAVR with small BEV according to postdilation strategy. METHODS: This observational, retrospective cohort study included 184 consecutive patients from a single center treated with 23 mm Sapien 3 Ultra (Edwards Lifesciences) BEV implantation in the aortic position and enrolled between January 2020 and April 2023. Patients treated with routine postdilation (RP, n = 73) were compared to patients treated according to local standard practice (SP, n = 111). Primary endpoint was 30-day mean TG. Secondary endpoints were incidence of 30-day prosthesis-patient mismatch (PPM), technical success and device success. RESULTS: Thirty-day mean TG was lower in RP versus SP (12.3 ± 4.6 mmHg vs. 14.1 ± 5.7 mmHg, p = 0.031), and incidence of PPM was less common with RP versus SP (47.3% vs. 71.0%, p = 0.006). Technical success (98.6% vs. 99.1%, p = 0.637) and device success (93.1% vs. 90.1%, p = 0.330) did not differ between groups. Differences in 30-day mean TG were driven by patients at normal flow (12.1 ± 4.0 mmHg vs. 15.0 ± 5.5 mmHg, p = 0.014), while no differences were evident among patients at low flow (12.5 ± 5.5 mmHg vs. 11.7 ± 5.5 mmHg, p = 0.644). RP decreased height and increased width of BEV, and a linear regression established that final BEV width could predict 30-day mean TG (r = -0.6654, p < 0.0001). CONCLUSIONS: RP after TAVR with small BEV was associated with more favorable forward-flow hemodynamics than SP.

2.
Rev Cardiovasc Med ; 23(5): 163, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-39077595

RESUMO

Background and Objective: As one of the most prevalent valvular pathologies affecting millions globally, moderate-to-severe tricuspid regurgitation (TR) predisposes to increased mortality. Despite the well-established risk of adverse outcomes, an overwhelming majority of TR patients are managed conservatively due to challenges associated with timely diagnosis, clinical course of the disease, competing comorbities that carry prohibitive surgical risk, and poor surgical outcomes. These challenges highlight the importance of transcatheter tricuspid valve replacement (TTVR) which has restructured TR management in promising and innovative ways. Methods: We start with an overview of the pathophysiology of TR considering its implications in management. We then elaborate on the current state of TR management, including its limitations, thereby highlighting the unique role of TTVR. This is followed by a review of perioperative considerations such as careful patient selection, role of multimodality imaging, the various imaging techniques that are available and their contribution towards successful TTVR. We then review the valves that are currently available and under investigation, including the latest data available on device efficacy and safety, and highlight the ongoing clinical trials. Results and Conclusions: TTVR is evolving at an exponential pace and has made its mark in the treatment of severe symptomatic tricuspid regurgitation. The promising results sustained by currently available devices and ongoing investigation of valves under development continue to pave the path for further innovation in transcatheter interventions. However, it is important to acknowledge and appreciate the novelty of this approach, the lack of long-term data on safety, efficacy, morbidity, and mortality, and use the lessons learned from real-world experiences to provide a definitive and reproducible solution for patients with symptomatic TR.

3.
JACC Case Rep ; 29(2): 102157, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38264301

RESUMO

Dynamic left ventricular outflow obstruction is a rare but severe complication of transcatheter aortic valve replacement. It presents as a paradoxical hemodynamic collapse after relieving the left ventricular afterload. Considering its unique pathophysiology, this entity dictates counterintuitive treatments. We describe a case of left ventricular outflow obstruction treated with venoarterial extracorporeal membrane oxygenation and discuss its management principles.