Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Cardiovasc Magn Reson ; : 101070, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39096969

RESUMO

BACKGROUND: Aortic wall shear stress (WSS) is a known predictor of ascending aortic growth in patients with a bicuspid aortic valve (BAV). The aim of this study was to study regional WSS and changes over time in BAV patients. METHODS: BAV patients and age-matched healthy controls underwent 4D flow CMR. Regional, peak systolic ascending aortic WSS, aortic valve function, aortic stiffness measures and aortic dimensions were assessed. In BAV patients, 4D flow CMR was repeated after three years follow-up and both at baseline and follow-up computed tomography angiography (CTA) was acquired. Aortic growth (volume increase of ≥5%) was measured on CTA. Regional WSS differences within patients' aorta and WSS changes over time were analysed using linear mixed-effect models and were associated with clinical parameters. RESULTS: Thirty BAV patients (aged 34 years [IQR 25-41]) were included in the follow-up analysis. Additionally, another 16 BAV patients and 32 healthy controls (aged 33 years [IQR 28-48]) were included for other regional analyses. Magnitude, axial, and circumferential WSS increased over time (all p<0.001) irrespective of aortic growth. The percentage of regions exposed to a magnitude WSS >95th percentile of healthy controls increased from 21% (baseline 506/2400 regions) to 31% (follow-up 734/2400 regions) (p<0.001). WSS angle, a measure of helicity near the aortic wall, decreased during follow-up. Magnitude WSS changes over time were associated with systolic blood pressure, peak aortic valve velocity, aortic valve regurgitation fraction, aortic stiffness indexes, and normalized flow displacement (all p<0.05). CONCLUSIONS: An increase of regional WSS over time was observed in BAV patients, irrespective of aortic growth. The increasing WSSs comprising a larger area of the aorta warrants further research to investigate the possible predictive value for aortic dissection.

2.
MAGMA ; 32(2): 269-279, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30171383

RESUMO

PURPOSE: With the hypothesis that 4D flow can be used in evaluation of cardiac shunts, we seek to evaluate the multilevel and interreader reproducibility of measurements of the blood flow, shunt fraction and shunt volume in patients with atrial septum defect (ASD) in practice at multiple clinical sites. MATERIALS AND METHODS: Four-dimensional flow MRI examinations were performed at four institutions across Europe and the US. Twenty-nine patients (mean age, 43 years; 11 male) were included in the study. Flow measurements were performed at three levels (valve, main artery and periphery) in both the pulmonary and systemic circulation by two independent readers and compared against stroke volumes from 4D flow anatomic data. Further, the shunt ratio (Qp/Qs) was calculated. Additionally, shunt volume was quantified at the atrial level by tracking the atrial septum. RESULTS: Measurements of the pulmonary blood flow at multiple levels correlate well whether measuring at the valve, main pulmonary artery or branch pulmonary arteries (r = 0.885-0.886). Measurements of the systemic blood flow show excellent correlation, whether measuring at the valve, ascending aorta or sum of flow from the superior vena cava (SVC) and descending aorta (r = 0.974-0.991). Intraclass agreement between the two observers for the flow measurements varies between 0.96 and 0.99. Compared with stroke volume, pulmonic flow is underestimated with 0.26 l/min at the main pulmonary artery level, and systemic flow is overestimated with 0.16 l/min at the ascending aorta level. Direct measurements of ASD flow are feasible in 20 of 29 (69%) patients. CONCLUSION: Blood flow and shunt quantification measured at multiple levels and performed by different readers are reproducible and consistent with 4D flow MRI.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Adulto , Velocidade do Fluxo Sanguíneo , Técnicas de Imagem Cardíaca/estatística & dados numéricos , Feminino , Comunicação Interatrial/classificação , Humanos , Imageamento Tridimensional/métodos , Imageamento Tridimensional/estatística & dados numéricos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Circulação Pulmonar , Reprodutibilidade dos Testes , Estudos Retrospectivos , Volume Sistólico
3.
Eur Radiol ; 27(6): 2309-2316, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27704198

RESUMO

OBJECTIVES: To investigate the additional value of transmural perfusion ratio (TPR) in dynamic CT myocardial perfusion imaging for detection of haemodynamically significant coronary artery disease compared with fractional flow reserve (FFR). METHODS: Subjects with suspected or known coronary artery disease were prospectively included and underwent a CT-MPI examination. From the CT-MPI time-point data absolute myocardial blood flow (MBF) values were temporally resolved using a hybrid deconvolution model. An absolute MBF value was measured in the suspected perfusion defect. TPR was defined as the ratio between the subendocardial and subepicardial MBF. TPR and MBF results were compared with invasive FFR using a threshold of 0.80. RESULTS: Forty-three patients and 94 territories were analysed. The area under the receiver operator curve was larger for MBF (0.78) compared with TPR (0.65, P = 0.026). No significant differences were found in diagnostic classification between MBF and TPR with a territory-based accuracy of 77 % (67-86 %) for MBF compared with 70 % (60-81 %) for TPR. Combined MBF and TPR classification did not improve the diagnostic classification. CONCLUSIONS: Dynamic CT-MPI-based transmural perfusion ratio predicts haemodynamically significant coronary artery disease. However, diagnostic performance of dynamic CT-MPI-derived TPR is inferior to quantified MBF and has limited incremental value. KEY POINTS: • The transmural perfusion ratio from dynamic CT-MPI predicts functional obstructive coronary artery disease • Performance of the transmural perfusion ratio is inferior to quantified myocardial blood flow • The incremental value of the transmural perfusion ratio is limited.


Assuntos
Estenose Coronária/diagnóstico por imagem , Hemodinâmica/fisiologia , Imagem de Perfusão do Miocárdio/métodos , Idoso , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X/métodos
4.
Radiology ; 274(3): 674-83, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25322342

RESUMO

PURPOSE: To validate an on-site algorithm for computation of fractional flow reserve (FFR) from coronary computed tomographic (CT) angiography data against invasively measured FFR and to test its diagnostic performance as compared with that of coronary CT angiography. MATERIALS AND METHODS: The institutional review board provided a waiver for this retrospective study. From coronary CT angiography data in 106 patients, FFR was computed at a local workstation by using a computational fluid dynamics algorithm. Invasive FFR measurement was performed in 189 vessels (80 of which had an FFR ≤ 0.80); these measurements were regarded as the reference standard. The diagnostic characteristics of coronary CT angiography-derived computational FFR, coronary CT angiography, and quantitative coronary angiography were evaluated against those of invasively measured FFR by using C statistics. Sensitivity and specificity were compared by using a two-sided McNemar test. RESULTS: For computational FFR, sensitivity was 87.5% (95% confidence interval [CI]: 78.2%, 93.8%), specificity was 65.1% (95% CI: 55.4%, 74.0%), and accuracy was 74.6% (95% CI: 68.4%, 80.8%), as compared with the finding of lumen stenosis of 50% or greater at coronary CT angiography, for which sensitivity was 81.3% (95% CI: 71.0%, 89.1%), specificity was 37.6% (95% CI: 28.5%, 47.4%), and accuracy was 56.1% (95% CI: 49.0%, 63.2%). C statistics revealed a larger area under the receiver operating characteristic curve (AUC) for computational FFR (AUC, 0.83) than for coronary CT angiography (AUC, 0.64). For vessels with intermediate (25%-69%) stenosis, the sensitivity of computational FFR was 87.3% (95% CI: 76.5%, 94.3%) and the specificity was 59.3% (95% CI: 47.8%, 70.1%). CONCLUSION: With use of a reduced-order algorithm, computation of the FFR from coronary CT angiography data can be performed locally, at a regular workstation. The diagnostic accuracy of coronary CT angiography-derived computational FFR for the detection of functionally important coronary artery disease (CAD) was good and was incremental to that of coronary CT angiography within a population with a high prevalence of CAD.


Assuntos
Algoritmos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Tomografia Computadorizada por Raios X , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
5.
Eur Radiol ; 25(1): 49-57, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25173626

RESUMO

OBJECTIVES: The purpose of this study was to estimate the myocardial area at risk (MAAR) using coronary computed tomography angiography (CTA) and Voronoi algorithm-based myocardial segmentation in comparison with single-photon emission computed tomography (SPECT). METHODS: Thirty-four patients with coronary artery disease underwent 128-slice coronary CTA, stress/rest thallium-201 SPECT, and coronary angiography (CAG). CTA-based MAAR was defined as the sum of all CAG stenosis (>50%) related territories (the ratio of the left ventricular volume). Using automated quantification software (17-segment model, 5-point scale), SPECT-based MAAR was defined as the number of segments with a score above zero as compared to the total 17 segments by summed stress score (SSS), difference (SDS) score map, and comprehensive SPECT interpretation with either SSS or SDS best correlating CAG findings (SSS/SDS). Results were compared using Pearson's correlation coefficient. RESULTS: Forty-nine stenoses were observed in 102 major coronary territories. Mean value of CTA-based MAAR was 28.3 ± 14.0%. SSS-based, SDS-based, and SSS/SDS-based MAAR was 30.1 ± 6.1%, 20.1 ± 15.8%, and 26.8 ± 15.7%, respectively. CTA-based MAAR was significantly related to SPECT-based MAAR (r = 0.531 for SSS; r = 0.494 for SDS; r = 0.814 for SSS/SDS; P < 0.05 in each). CONCLUSIONS: CTA-based Voronoi algorithm myocardial segmentation reliably quantifies SPECT-based MAAR. KEY POINTS: • Voronoi algorithm allows for three-dimensional myocardial segmentation of coronary CT angiography • Stenosis-related CT myocardial territories correlate to SPECT based area at risk • CT angiography myocardial segmentation may assist in clinical decision-making.


Assuntos
Algoritmos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Software , Idoso , Feminino , Humanos , Masculino , Estudos Retrospectivos , Tomografia Computadorizada de Emissão de Fóton Único/métodos
6.
Eur Heart J Cardiovasc Imaging ; 23(12): 1680-1689, 2022 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-34977931

RESUMO

AIMS: Aortic wall shear stress (WSS) distributions in bicuspid aortic valve (BAV) patients have been associated with aortic dilatation, but prospective, longitudinal data are missing. This study assessed differences in aortic WSS distributions between BAV patients and healthy controls and determined the association of WSS with aortic growth in patients. METHODS AND RESULTS: Sixty subjects underwent four-dimensional (4D) flow cardiovascular magnetic resonance of the thoracic aorta (32 BAV patients and 28 healthy controls). Peak velocity, pulse wave velocity, aortic distensibility, peak systolic WSS (magnitude, axial, and circumferential), and WSS angle were assessed. WSS angle is defined as the angle between the WSSmagnitude and WSSaxial component. In BAV patients, three-year computed tomography angiography-based aortic volumetric growth was determined in the proximal and entire ascending aorta. WSSaxial was significantly lower in BAV patients compared with controls (0.93 vs. 0.72 Pa, P = 0.047) and WSScircumferential and WSS angle were significantly higher (0.29 vs. 0.64 Pa and 18° vs. 40°, both P < 0.001). Significant volumetric growth of the proximal ascending aorta occurred in BAV patients (from 49.1 to 52.5 cm3, P = 0.003). In multivariable analysis corrected for baseline aortic volume and diastolic blood pressure, WSS angle was the only parameter independently associated with proximal aortic growth (P = 0.031). In the entire ascending aorta, besides the WSS angle, the WSSmagnitude was also independently associated with growth. CONCLUSION: Increased WSScircumferential and especially WSS angle are typical in BAV patients. WSS angle was found to predict aortic growth. These findings highlight the potential role of WSS measurements in BAV patients to stratify patients at risk for aortic dilation.


Assuntos
Doenças da Aorta , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Humanos , Valva Aórtica/diagnóstico por imagem , Doenças das Valvas Cardíacas/complicações , Estudos Prospectivos , Análise de Onda de Pulso , Velocidade do Fluxo Sanguíneo/fisiologia , Aorta/patologia , Estresse Mecânico , Doenças da Aorta/patologia , Hemodinâmica
7.
Can J Cardiol ; 37(3): 433-442, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32445794

RESUMO

BACKGROUND: Noncompaction cardiomyopathy (NCCM) is characterized by a thickened myocardial wall with excessive trabeculations of the left ventricle, and ∼30% is explained by a (likely) pathogenic variant [(L)PV] in a cardiomyopathy gene. Diagnosing an (L)PV is important because it allows accurate identification of which relatives are at risk and helps predicting prognosis. The goal of this study was to assess which specific clinical and morphologic characteristics of the myocardium may predict an (L)PV and which of the cardiovascular magnetic resonance (CMR) diagnostic criteria for NCCM can best be used for that purpose. METHODS: Sixty-two patients with NCCM, diagnosed by means of echocardiographic Jenni criteria, underwent CMR imaging that was evaluated according the Petersen, Stacey, Jacquier, Captur, and Choi diagnostic CMR criteria for NCCM. Patients also underwent DNA testing and were stratified according to having an (L)PV. RESULTS: Thirty-three patients (53%) with NCCM had an (L)PV. The apical and mid-lateral segments were the dominant locations for meeting Petersen and/or Stacey criteria. Correlation between different CMR criteria varied from moderate to very strong. In multivariate binary logistic regression analysis with CMR and non-CMR parameters, independent positive predictors for an (L)PV were familial cardiomyopathy, trabecular mass, and meeting Petersen criteria in ≥ 2 out of 3 long-axis views, whereas left bundle branch block and hypertension were negative predictors. The receiver operating characteristic curve of this multivariate model had an area under the curve of 0.89 (95% confidence interval 0.82-0.97). CONCLUSIONS: CMR criteria together with family history help to distinguish those patients in whom an (L)PV can be identified, consequently leading to referral for genetic diagnostics and cascade screening.


Assuntos
Cardiomiopatias , Testes Genéticos/métodos , Cardiopatias Congênitas , Ventrículos do Coração , Imagem Cinética por Ressonância Magnética/métodos , Anamnese/métodos , Adulto , Cardiomiopatias/congênito , Cardiomiopatias/diagnóstico , Ecocardiografia/métodos , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/genética , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Países Baixos , Tamanho do Órgão , Seleção de Pacientes , Valor Preditivo dos Testes , Prognóstico , Encaminhamento e Consulta
8.
Int J Cardiovasc Imaging ; 36(9): 1771-1780, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32451876

RESUMO

Left ventricular global longitudinal strain (LVGLS) analysis is a sensitive measurement of myocardial deformation most often done using speckle-tracking transthoracic echocardiography (TTE). We propose a novel approach to measure LVGLS using feature-tracking software on the magnitude dataset of 4D flow cardiovascular magnetic resonance (CMR) and compare it to dynamic computed tomography (CT) and speckle tracking TTE derived measurements. In this prospective cohort study 59 consecutive adult patients with a bicuspid aortic valve (BAV) were included. The study protocol consisted of TTE, CT, and CMR on the same day. Image analysis was done using dedicated feature-tracking (4D flow CMR and CT) and speckle-tracking (TTE) software, on apical 2-, 3-, and 4-chamber long-axis multiplanar reconstructions (4D flow CMR and CT) or standard apical 2-, 3-, and 4-chamber acquisitions (TTE). CMR and CT GLS analysis was feasible in all patients. Good correlations were observed for GLS measured by CMR (- 21 ± 3%) and CT (- 20 ± 3%) versus TTE (- 20 ± 3%, Pearson's r: 0.67 and 0.65, p < 0.001). CMR also correlated well with CT (Pearson's r 0.62, p < 0.001). The inter-observer analysis showed moderate to good reproducibility of GLS measurement by CMR, CT and TTE (Pearsons's r: 0.51, 0.77, 0.70 respectively; p < 0.05). Additionally, ejection fraction (EF), end-diastolic and end-systolic volume measurements (EDV and ESV) correlated well between all modalities (Pearson's r > 0.61, p < 0.001). Feature-tracking GLS analysis is feasible using the magnitude images acquired with 4D flow CMR. GLS measurement by CMR correlates well with CT and speckle-tracking 2D TTE. GLS analysis on 4D flow CMR allows for an integrative approach, integrating flow and functional data in a single sequence. Not applicable, observational study.


Assuntos
Valva Aórtica/anormalidades , Ecocardiografia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Contração Miocárdica , Tomografia Computadorizada por Raios X , Função Ventricular Esquerda , Adolescente , Adulto , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Estudos de Viabilidade , Feminino , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Volume Sistólico , Adulto Jovem
9.
Int J Cardiovasc Imaging ; 35(6): 1111-1118, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30963352

RESUMO

The purpose of this study was to compare invasively measured aorta flow with 2D phase contrast flow and 4D flow measurements by cardiovascular magnetic resonance (CMR) imaging in a large animal model. Nine swine (mean weight 63 ± 4 kg) were included in the study. 4D flow CMR exams were performed on a 1.5T MRI scanner. Flow measurements were performed on 4D flow images at the aortic valve level, in the ascending aorta, and main pulmonary artery. Simultaneously, flow was measured using an invasive flow probe, placed around the ascending aorta. Additionally, standard 2D phase contrast flow and 2D left ventricular (LV) volumetric data were used for comparison. The correlations of cardiac output (CO) between the invasive flow probe, and CMR modalities were strong to very strong. CO measured by 4D flow CMR correlated better with the CO measured by the invasive flow probe than 2D flow CMR flow and volumetric LV data (4D flow CMR: Spearman's rho = 0.86 at the aortic valve level and 0.90 at the ascending aorta level; 2D flow CMR: 0.67 at aortic valve level; LV measurements: 0.77). In addition, there tended to be a correlation between mean pulmonary artery flow and aorta flow with 4D flow (Spearman's rho = 0.65, P = 0.07), which was absent in measurements obtained with 2D flow CMR (Spearman's rho = 0.40, P = 0.33). This study shows that aorta flow can be accurately measured by 4D flow CMR compared to simultaneously measured invasive flow. This helps to further validate the quantitative reliability of this technique.


Assuntos
Aorta/diagnóstico por imagem , Cateterismo Cardíaco , Hemodinâmica , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Artéria Pulmonar/diagnóstico por imagem , Circulação Pulmonar , Animais , Aorta/fisiologia , Velocidade do Fluxo Sanguíneo , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Humanos , Interpretação de Imagem Assistida por Computador , Modelos Animais , Valor Preditivo dos Testes , Artéria Pulmonar/fisiologia , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Sus scrofa , Fatores de Tempo , Transdutores de Pressão
10.
Int J Cardiol ; 276: 230-235, 2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30213599

RESUMO

BACKGROUND: No established reference-standard technique is available for ascending aortic diameter measurements. The aim of this study was to determine agreement between modalities and techniques. METHODS: In patients with aortic pathology transthoracic echocardiography, computed tomography angiography (CTA) and magnetic resonance angiography (MRA) were performed. Aortic diameters were measured at the sinus of Valsalva (SoV), sinotubular junction (STJ) and tubular ascending aorta (TAA) during mid-systole and end-diastole. In echocardiography both the inner edge-to-inner edge (I-I edge) and leading edge-to­leading edge (L-L edge) methods were applied, and the length of the aortic annulus to the most cranial visible part of the ascending aorta was measured. In CTA and MRA the I-I method was used. RESULTS: Fifty patients with bicuspid aortic valve (36 ±â€¯13 years, 26% female) and 50 Turner patients (35 ±â€¯13 years) were included. Comparison of all aortic measurements showed a mean difference of 5.4 ±â€¯2.7 mm for the SoV, 5.1 ±â€¯2.0 mm for the STJ and 4.8 ±â€¯2.1 mm for the TAA. The maximum difference was 18 mm. The best agreement was found between echocardiography L-L edge and CTA during mid-systole. CTA and MRA showed good agreement. A mean difference of 1.5 ±â€¯1.3 mm and 1.8 ±â€¯1.5 mm was demonstrated at the level of the STJ and TAA comparing mid-systolic with end-diastolic diameters. The visible length of the aorta increased on average 5.3 ±â€¯5.1 mmW during mid-systole. CONCLUSIONS: MRA and CTA showed best agreement with L-L edge method by echocardiography. In individual patients large differences in ascending aortic diameter were demonstrated, warranting measurement standardization. The use of CTA or MRA is advised at least once.


Assuntos
Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Ecocardiografia/métodos , Angiografia por Ressonância Magnética/métodos , Adulto , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide , Estudos de Coortes , Angiografia por Tomografia Computadorizada/normas , Ecocardiografia/normas , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/epidemiologia , Humanos , Angiografia por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Síndrome de Turner/diagnóstico por imagem , Síndrome de Turner/epidemiologia , Adulto Jovem
11.
Int J Cardiovasc Imaging ; 33(12): 1895-1903, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28631106

RESUMO

Integration of volumetric heart chamber quantification by 3D echocardiography into clinical practice has been hampered by several factors which a new fully automated algorithm (Left Heart Model, (LHM)) may help overcome. This study therefore aims to evaluate the feasibility and accuracy of the LHM software in quantifying left atrial and left ventricular volumes and left ventricular ejection fraction in a cohort of patients with a bicuspid aortic valve. Patients with a bicuspid aortic valve were prospectively included. All patients underwent 2D and 3D transthoracic echocardiography and computed tomography. Left atrial and ventricular volumes were obtained using the automated program, which did not require manual contour detection. For comparison manual and semi-automated measurements were performed using conventional 2D and 3D datasets. 53 patients were included, in four of those patients no 3D dataset could be acquired. Additionally, 12 patients were excluded based on poor imaging quality. Left ventricular end-diastolic and end-systolic volumes and ejection fraction calculated by the LHM correlated well with manual 2D and 3D measurements (Pearson's r between 0.43 and 0.97, p < 0.05). Left atrial volume (LAV) also correlated significantly although LHM did estimate larger LAV compared to both 2DE and 3DE (Pearson's r between 0.61 and 0.81, p < 0.01). The fully automated software works well in a real-world setting and helps to overcome some of the major hurdles in integrating 3D analysis into daily practice, as it is user-independent and highly reproducible in a group of patients with a clearly defined and well-studied valvular abnormality.


Assuntos
Valva Aórtica/anormalidades , Ecocardiografia Tridimensional , Átrios do Coração/diagnóstico por imagem , Doenças das Valvas Cardíacas/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Validação de Programas de Computador , Adulto , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Função do Átrio Esquerdo , Automação , Doença da Válvula Aórtica Bicúspide , Estudos de Viabilidade , Feminino , Átrios do Coração/fisiopatologia , Doenças das Valvas Cardíacas/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Volume Sistólico , Tomografia Computadorizada por Raios X , Função Ventricular Esquerda , Adulto Jovem
12.
Eur J Radiol ; 95: 141-146, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28987660

RESUMO

PURPOSE: The aim of this study is to describe the prevalence, anatomy, associations and clinical impact of partial anomalous pulmonary venous return in patients with Turner syndrome. METHODS AND RESULTS: All Turner patients who presented at our Turner clinic, between January 2007 and October 2015 were included in this study and underwent ECG, echocardiography and advanced imaging such as cardiac magnetic resonance or computed tomography as part of their regular clinical workup. All imaging was re-evaluated and detailed anatomy was described. Partial anomalous pulmonary venous return was diagnosed in 24 (25%) out of 96 Turner patients included and 14 (58%) of these 24 partial anomalous pulmonary venous return had not been reported previously. Right atrial or ventricular dilatation was present in 11 (46%) of 24 partial anomalous pulmonary venous return patients. CONCLUSION: When studied with advanced imaging modalities and looked for with specific attention, PAPVR is found in 1 out of 4 Turner patients. Half of these patients had right atrial and/or ventricular dilatation. Evaluation of pulmonary venous return should be included in the standard protocol in all Turner patients.


Assuntos
Veias Pulmonares/anormalidades , Veias Pulmonares/fisiopatologia , Síndrome de Turner/fisiopatologia , Adulto , Ecocardiografia/métodos , Eletrocardiografia/métodos , Feminino , Humanos , Masculino , Veias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
13.
JACC Cardiovasc Imaging ; 10(7): 760-770, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28109933

RESUMO

OBJECTIVES: The aim of this study was to investigate the individual and combined accuracy of dynamic computed tomography (CT) myocardial perfusion imaging (MPI) and computed tomography angiography (CTA) fractional flow reserve (FFR) for the identification of functionally relevant coronary artery disease (CAD). BACKGROUND: Coronary CTA has become an established diagnostic test for ruling out CAD, but it does not allow interpretation of the hemodynamic severity of stenotic lesions. Two recently introduced functional CT techniques are dynamic MPI and CTA FFR using computational fluid dynamics. METHODS: From 2 institutions, 74 patients (n = 62 men, mean age 61 years) planned for invasive angiography with invasive FFR measurement in 142 vessels underwent CTA imaging and dynamic CT MPI during adenosine vasodilation. A patient-specific myocardial blood flow index was calculated, normalized to remote myocardial global left ventricular blood flow. CTA FFR was computed using an on-site, clinician-operated application. Using binary regression, a single functional CT variable was created combining both CT MPI and CTA FFR. Finally, stepwise diagnostic work-up of CTA FFR with selective use of CT MPI was simulated. The diagnostic performance of CT MPI, CTA FFR, and CT MPI integrated with CTA FFR was evaluated using C statistics with invasive FFR, with a threshold of 0.80 as a reference. RESULTS: Sensitivity, specificity, and accuracy were 73% (95% confidence interval [CI]: 61% to 86%), 68% (95% CI: 56% to 80%), and 70% (95% CI: 62% to 79%) for CT MPI and 82% (95% CI: 72% to 92%), 60% (95% CI: 48% to 72%), and 70% (63% to 80%) for CTA FFR. For CT MPI integrated with CTA FFR, diagnostic accuracy was 79% (95% CI: 71% to 87%), with improvement of the area under the curve from 0.78 to 0.85 (p < 0.05). Accuracy of the stepwise approach was 77%. CONCLUSIONS: CT MPI and CTA FFR both identify functionally significant CAD, with comparable accuracy. Diagnostic performance can be improved by combining the techniques. A stepwise approach, reserving CT MPI for intermediate CTA FFR results, also improves diagnostic performance while omitting nearly one-half of the population from CT MPI examinations.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio/métodos , Adenosina/administração & dosagem , Idoso , Área Sob a Curva , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Londres , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Países Baixos , Valor Preditivo dos Testes , Curva ROC , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Vasodilatadores/administração & dosagem
14.
J Cardiovasc Comput Tomogr ; 10(2): 105-13, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26747231

RESUMO

BACKGROUND: Recently several publications described the diagnostic value of coronary CT angiography (coronary CTA) derived fractional flow reserve (CTA-FFR). For a recently introduced on-site CTA-FFR application, detailed methodology and factors potentially affecting performance have not yet been described. OBJECTIVE: To provide a methodological background for an on-site CTA-FFR application and evaluate the effect of patient and acquisition characteristics. METHODS: The on-site CTA-FFR application utilized a reduced-order hybrid model applying pressure drop models within stenotic regions. In 116 patients and 203 vessels the diagnostic performance of CTA-FFR was investigated using invasive FFR measurements as a reference. The effect of several potentially relevant factors on CTA-FFR was investigated. RESULTS: 90 vessels (44%) had a hemodynamically relevant stenosis according to invasive FFR (threshold ≤0.80). The overall vessel-based sensitivity, specificity and accuracy of CTA-FFR were 88% (CI 95%:79-94%), 65% (55-73%) and 75% (69-81%). The specificity was significantly lower in the presence of misalignment artifacts (25%, CI: 6-57%). A non-significant reduction in specificity from 74% (60-85%) to 48% (26-70%) was found for higher coronary artery calcium scores. Left ventricular mass, diabetes mellitus and large vessel size increased the discrepancy between invasive FFR and CTA-FFR values. CONCLUSIONS: On-site calculation of CTA-FFR can identify hemodynamically significant CAD with an overall per-vessel accuracy of 75% in comparison to invasive FFR. The diagnostic performance of CTA-FFR is negatively affected by misalignment artifacts. CTA-FFR is potentially affected by left ventricular mass, diabetes mellitus and vessel size.


Assuntos
Algoritmos , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Tomografia Computadorizada Multidetectores , Testes Imediatos , Calcificação Vascular/diagnóstico por imagem , Idoso , Artefatos , Cateterismo Cardíaco , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Hidrodinâmica , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Prognóstico , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Calcificação Vascular/fisiopatologia
15.
Int J Cardiovasc Imaging ; 32(2): 301-307, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26498478

RESUMO

Over the past 10 years there has been intense research in the development of volumetric visualization of intracardiac flow by cardiac magnetic resonance (CMR).This volumetric time resolved technique called CMR 4D flow imaging has several advantages over standard CMR. It offers anatomical, functional and flow information in a single free-breathing, ten-minute acquisition. However, the data obtained is large and its processing requires dedicated software. We evaluated a cloud-based application package that combines volumetric data correction and visualization of CMR 4D flow data, and assessed its accuracy for the detection and grading of aortic valve regurgitation using transthoracic echocardiography as reference. Between June 2014 and January 2015, patients planned for clinical CMR were consecutively approached to undergo the supplementary CMR 4D flow acquisition. Fifty four patients(median age 39 years, 32 males) were included. Detection and grading of the aortic valve regurgitation using CMR4D flow imaging were evaluated against transthoracic echocardiography. The agreement between 4D flow CMR and transthoracic echocardiography for grading of aortic valve regurgitation was good (j = 0.73). To identify relevant,more than mild aortic valve regurgitation, CMR 4D flow imaging had a sensitivity of 100 % and specificity of 98 %. Aortic regurgitation can be well visualized, in a similar manner as transthoracic echocardiography, when using CMR 4D flow imaging.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/patologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Feminino , Humanos , Masculino , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença
16.
Eur J Radiol ; 85(10): 1849-1856, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27666627

RESUMO

OBJECTIVES: In this study, we evaluated a cloud-based platform for cardiac magnetic resonance (CMR) four-dimensional (4D) flow imaging, with fully integrated correction for eddy currents, Maxwell phase effects, and gradient field non-linearity, to quantify forward flow, regurgitation, and peak systolic velocity over the pulmonary artery. METHODS: We prospectively recruited 52 adult patients during one-year period from July 2014. The 4D flow and planar (2D) phase-contrast (PC) were acquired during same scanning session, but 4D flow was scanned after injection of a gadolinium-based contrast agent. Eddy-currents were semi-automatically corrected using the web-based software. Flow over pulmonary valve was measured and the 4D flow values were compared against the 2D PC ones. RESULTS: The mean forward flow was 92 (±30) ml/cycle measured with 4D flow and 86 (±29) ml/cycle measured with 2D PC, with a correlation of 0.82 and a mean difference of -6ml/cycle (-41-29). For the regurgitant fraction the correlation was 0.85 with a mean difference of -0.95% (-17-15). Mean peak systolic velocity measured with 4D flow was 92 (±49) cm/s and 108 (±56) cm/s with 2D PC, having a correlation of 0.93 and a mean difference of 16cm/s (-24-55). CONCLUSION: 4D flow imaging post-processed with an integrated cloud-based application accurately quantifies pulmonary flow. However, it may underestimate the peak systolic velocity.


Assuntos
Computação em Nuvem , Cardiopatias Congênitas/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Valva Pulmonar/diagnóstico por imagem , Adulto , Velocidade do Fluxo Sanguíneo , Meios de Contraste , Feminino , Gadolínio , Cardiopatias Congênitas/fisiopatologia , Humanos , Aumento da Imagem , Masculino , Estudos Prospectivos , Valva Pulmonar/fisiopatologia , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa