Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Eur Radiol ; 19(7): 1822-5, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19499263

RESUMO

Bronchial artery origins are subject to a wide range of anatomic variations, of which interventional radiologists should be aware. The authors report a patient with angina in whom an anomalous bronchial artery originated from the sinus node branch of the right coronary artery, causing a coronary steal phenomenon. The patient's symptom was successfully treated by transcatheter embolisation of the anomalous bronchial artery, which seems to be an effective alternative to surgery.


Assuntos
Angina Instável/complicações , Angina Instável/diagnóstico por imagem , Artérias Brônquicas/anormalidades , Artérias Brônquicas/diagnóstico por imagem , Angiografia Coronária , Anomalias dos Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade
3.
Cardiovasc Intervent Radiol ; 31(3): 663-8, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18259810

RESUMO

A case of esophageal perforation caused by a retrievable covered stent is presented. The distal end of the stent was protruding into the mediastinum, which made it impossible to negotiate a guidewire through the stent into the distal esophagus. The stent was successfully removed with use of a stent retrieval set, and esophageal perforation was treated with a second, covered stent with a good result. Fatality associated with this complication might be prevented by virtue of the retrievability of the stent we used. This result points to the effectiveness of a retrievable stent for the palliative treatment of malignant esophageal stricture.


Assuntos
Cateterismo/instrumentação , Remoção de Dispositivo/métodos , Perfuração Esofágica/etiologia , Estenose Esofágica/etiologia , Estenose Esofágica/terapia , Stents/efeitos adversos , Cateterismo/métodos , Neoplasias Esofágicas/complicações , Neoplasias Esofágicas/diagnóstico , Perfuração Esofágica/terapia , Estenose Esofágica/diagnóstico , Esofagoscopia/métodos , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Cuidados Paliativos/métodos , Desenho de Prótese , Falha de Prótese , Retratamento , Medição de Risco , Resultado do Tratamento
4.
Radiology ; 224(3): 725-30, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12202706

RESUMO

PURPOSE: To evaluate percutaneous transluminal forceps biopsy in patients suspected of having a malignant biliary obstruction. MATERIALS AND METHODS: One hundred thirty consecutive patients (82 men and 48 women; mean age, 59 years) with obstructive jaundice underwent transluminal forceps biopsy during or after percutaneous transhepatic biliary drainage. The lesions involved the common bile duct (n = 58), common hepatic duct (n = 39), hilum (n = 14), ampullary segment of the common bile duct (n = 11), right or left intrahepatic bile duct (n = 5), or the entire extrahepatic bile duct (n = 3). In each patient, three to five specimens (mean, 4.1 specimens) were taken from the lesion with 5.4-F biopsy forceps. The final diagnosis for each patient was confirmed with pathologic findings at surgery, additional histocytologic data, or clinical and radiologic follow-up. Statistical analysis was performed with the chi(2) test; a P value < or =.05 was considered to indicate a significant difference. RESULTS: Ninety-eight of 130 biopsies resulted in correct diagnoses of malignancy. Five biopsy diagnoses proved to be true-negative. There were 27 false-negative diagnoses and no false-positive diagnoses. The diagnostic performance of transluminal forceps biopsy in malignant biliary obstructions was as follows: sensitivity, 78.4%; specificity, 100%; and accuracy, 79.2%. Sensitivity of biopsy in the 82 patients with cholangiocarcinoma was higher than in the 43 patients with malignant tumors other than cholangiocarcinoma (86.6% vs 62.8%, P <.005). Sensitivity was significantly lower in the ampullary segment of the common bile duct than in other sites (P <.01). No major complications related to the biopsy procedures occurred. CONCLUSION: Percutaneous transluminal forceps biopsy is a safe procedure that is easy to perform through a transhepatic biliary drainage tract. It provides relatively high accuracy in the diagnosis of malignant biliary obstructions.


Assuntos
Ductos Biliares/patologia , Neoplasias do Sistema Biliar/patologia , Biópsia/métodos , Colestase/patologia , Adulto , Idoso , Ductos Biliares Extra-Hepáticos/patologia , Ductos Biliares Intra-Hepáticos/patologia , Ducto Colédoco/patologia , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Instrumentos Cirúrgicos
5.
J Vasc Interv Radiol ; 13(3): 275-83, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11875087

RESUMO

PURPOSE: To assess whether coaxial placement of uncovered and covered expandable nitinol stents overcomes the disadvantages of the increased migration rate seen with covered stents and the tumor ingrowth seen in uncovered stents in the treatment of malignant gastric outlet obstructions. MATERIALS AND METHODS: Two types of expandable nitinol stent were designed: an uncovered stent and a covered stent. Under fluoroscopic guidance, the uncovered and covered stents were placed coaxially with complete overlap in 39 consecutive patients with malignant gastric outlet obstruction caused by stomach cancer. Food intake capacity was graded on a scale of 0-4. Stent patency rate was estimated by the Kaplan-Meier method. RESULTS: Technical success rate was 97% (38 of 39 patients). After stent placement, food intake capacity improved at least one grade in 36 patients. Stent migration occurred in three patients (8%), that is, partial (n = 2) or complete (n = 1) upward migration of the inner covered stent into the stomach. Two of these patients were treated by placement of an additional covered stent. During the mean follow-up period of 134 days (range, 15-569 d), 10 patients developed recurrent symptoms of obstruction with tumor overgrowth being the most common cause. Nine underwent placement of an additional covered stent with good results. The median period of primary stent patency was 157 days (mean, 278 d). The 30-, 60-, and 180-day patency rates were 97%, 91%, and 39%, respectively. Four patients (10%) died within 1 month after the procedure. CONCLUSION: Coaxial stent placement technique seems to contribute to decreasing the migration rate of the stent and decrease the rate of recurrent obstruction by preventing or delaying tumor ingrowth.


Assuntos
Obstrução da Saída Gástrica/terapia , Stents , Neoplasias Gástricas/complicações , Adulto , Idoso , Idoso de 80 Anos ou mais , Ligas , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Migração de Corpo Estranho/prevenção & controle , Obstrução da Saída Gástrica/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Stents/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa