Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 127
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 103(6): 863-872, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38563074

RESUMO

BACKGROUND: There is limited data on retrograde chronic total occlusion (CTO) percutaneous coronary intervention (PCI) via ipsilateral epicardial collaterals (IEC). AIMS: To compare the clinical and angiographic characteristics, and outcomes of retrograde CTO PCI via IEC versus other collaterals in a large multicenter registry. METHODS: Observational cohort study from the Prospective Global registry for the study of Chronic Total Occlusion Intervention (PROGRESS-CTO). RESULTS: Of 4466 retrograde cases performed between 2012 and 2023, crossing through IEC was attempted in 191 (4.3%) cases with 50% wiring success. The most common target vessel in the IEC group was the left circumflex (50%), in comparison to other retrograde cases, where the right coronary artery was most common (70%). The Japanese CTO score was similar between the two groups (3.13 ± 1.23 vs. 3.06 ± 1.06, p = 0.456); however, the IEC group had a higher Prospective Global Registry for the Study of Chronic Total Occlusion Intervention (PROGRESS-CTO) score (1.95 ± 1.02 vs. 1.27 ± 0.92, p < 0.0001). The most used IEC guidewire was the SUOH 03 (39%), and the most frequently used microcatheter was the Caravel (43%). Dual injection was less common in IEC cases (66% vs. 89%, p < 0.0001). Technical (76% vs. 79%, p = 0.317) and procedural success rates (74% vs. 79%, p = 0.281) were not different between the two groups. However, IEC cases had a higher procedural complications rate (25.8% vs. 16.4%, p = 0.0008), including perforations (17.3% vs. 9.0%, p = 0.0001), pericardiocentesis (3.1% vs. 1.2%, p = 0.018), and dissection/thrombus of the donor vessel (3.7% vs. 1.2%, p = 0.002). CONCLUSION: The use of IEC for retrograde CTO PCI was associated with similar technical and procedural success rates when compared with other retrograde cases, but higher incidence of periprocedural complications.


Assuntos
Circulação Colateral , Angiografia Coronária , Circulação Coronária , Oclusão Coronária , Intervenção Coronária Percutânea , Sistema de Registros , Humanos , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Oclusão Coronária/fisiopatologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Masculino , Resultado do Tratamento , Doença Crônica , Feminino , Idoso , Pessoa de Meia-Idade , Fatores de Tempo , Fatores de Risco
2.
Catheter Cardiovasc Interv ; 103(6): 856-862, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38629740

RESUMO

BACKGROUND: The complex high-risk indicated percutaneous coronary intervention (CHIP) score is a tool developed using the British Cardiovascular Intervention Society (BCIS) database to define CHIP cases and predict in-hospital major adverse cardiac or cerebrovascular events (MACCE). AIM: To assess the validity of the CHIP score in chronic total occlusion (CTO) percutaneous coronary intervention (PCI). METHODS: We evaluated the performance of the CHIP score on 8341 CTO PCIs from the Prospective Global Registry for the Study of Chronic Total Occlusion Intervention (PROGRESS-CTO) performed at 44 centers between 2012 and 2023. RESULTS: In our cohort, 7.8% (n = 647) of patients had a CHIP score of 0, 50.2% (n = 4192) had a CHIP score of 1-2, 26.2% (n = 2187) had a CHIP score of 3-4, 11.7% (n = 972) had a CHIP score of 5-6, 3.3% (n = 276) had a CHIP score of 7-8, and 0.8% (n = 67) had a CHIP score of 9+. The incidence of MACCE for a CHIP score of 0 was 0.6%, reaching as high as 8.7% for a CHIP score of 9+, confirming that a higher CHIP score is associated with a higher risk of MACCE. The estimated increase in the risk of MACCE per one score unit increase was 100% (95% confidence interval [CI]: 65%-141%). The AUC of the CHIP score model for predicting MACCE in our cohort was 0.63 (95% CI: 0.58-0.67). There was a positive correlation between the CHIP score and the PROGRESS-CTO MACE score (Spearman's correlation: 0.37; 95% CI: 0.35-0.39; p < 0.001). CONCLUSIONS: The CHIP score has modest predictive capacity for MACCE in CTO PCI.


Assuntos
Oclusão Coronária , Técnicas de Apoio para a Decisão , Intervenção Coronária Percutânea , Valor Preditivo dos Testes , Sistema de Registros , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Crônica , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Intervenção Coronária Percutânea/efeitos adversos , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
3.
Lancet ; 399(10333): 1401-1410, 2022 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-35390320

RESUMO

BACKGROUND: Renal denervation has been shown to lower blood pressure in the presence of antihypertensive medications; however, long-term safety and efficacy data from randomised trials of renal denervation are lacking. In this pre-specified analysis of the SPYRAL HTN-ON MED study, we compared changes in blood pressure, antihypertensive drug use, and safety up to 36 months in renal denervation versus a sham control group. METHODS: This randomised, single-blind, sham-controlled trial enrolled patients from 25 clinical centres in the USA, Germany, Japan, the UK, Australia, Austria, and Greece, with uncontrolled hypertension and office systolic blood pressure between 150 mm Hg and 180 mm Hg and diastolic blood pressure of 90 mm Hg or higher. Eligible patients had to have 24-h ambulatory systolic blood pressure between 140 mm Hg and less than 170 mm Hg, while taking one to three antihypertensive drugs with stable doses for at least 6 weeks. Patients underwent renal angiography and were randomly assigned (1:1) to radiofrequency renal denervation or a sham control procedure. Patients and physicians were unmasked after 12-month follow-up and sham control patients could cross over after 12-month follow-up completion. The primary endpoint was the treatment difference in mean 24-h systolic blood pressure at 6 months between the renal denervation group and the sham control group. Statistical analyses were done on the intention-to-treat population. Long-term efficacy was assessed using ambulatory and office blood pressure measurements up to 36 months. Drug surveillance was used to assess medication use. Safety events were assessed up to 36 months. This trial is registered with ClinicalTrials.gov, NCT02439775; prospectively, an additional 260 patients are currently being randomly assigned as part of the SPYRAL HTN-ON MED Expansion trial. FINDINGS: Between July 22, 2015, and June 14, 2017, among 467 enrolled patients, 80 patients fulfilled the qualifying criteria and were randomly assigned to undergo renal denervation (n=38) or a sham control procedure (n=42). Mean ambulatory systolic and diastolic blood pressure were significantly reduced from baseline in the renal denervation group, and were significantly lower than the sham control group at 24 and 36 months, despite a similar treatment intensity of antihypertensive drugs. The medication burden at 36 months was 2·13 medications (SD 1·15) in the renal denervation group and 2·55 medications (2·19) in the sham control group (p=0·26). 24 (77%) of 31 patients in the renal denervation group and 25 (93%) of 27 patients in the sham control group adhered to medication at 36 months. At 36 months, the ambulatory systolic blood pressure reduction was -18·7 mm Hg (SD 12·4) for the renal denervation group (n=30) and -8·6 mm Hg (14·6) for the sham control group (n=32; adjusted treatment difference -10·0 mm Hg, 95% CI -16·6 to -3·3; p=0·0039). Treatment differences between the renal denervation group and sham control group at 36 months were -5·9 mm Hg (95% CI -10·1 to -1·8; p=0·0055) for mean ambulatory diastolic blood pressure, -11·0 mm Hg (-19·8 to -2·1; p=0·016) for morning systolic blood pressure, and -11·8 mm Hg (-19·0 to -4·7; p=0·0017) for night-time systolic blood pressure. There were no short-term or long-term safety issues associated with renal denervation. INTERPRETATION: Radiofrequency renal denervation compared with sham control produced a clinically meaningful and lasting blood pressure reduction up to 36 months of follow-up, independent of concomitant antihypertensive medications and without major safety events. Renal denervation could provide an adjunctive treatment modality in the management of patients with hypertension. FUNDING: Medtronic.


Assuntos
Anti-Hipertensivos , Hipertensão , Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea , Monitorização Ambulatorial da Pressão Arterial , Denervação/métodos , Humanos , Hipertensão/cirurgia , Rim , Método Simples-Cego , Simpatectomia/métodos , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 101(4): 747-755, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36740236

RESUMO

BACKGROUND: The impact of occlusion length on the procedural techniques and outcomes of chronic total occlusion (CTO) percutaneous coronary intervention (PCI) has received limited study. METHODS: We examined the clinical and angiographic characteristics and procedural outcomes of 10,335 CTO PCIs at 42 US and non-US centers between 2012 and 2022. The cohort was divided into two groups based on lesion length (≥20 mm vs. <20 mm). RESULTS: Long lesions were present in 7208 (70%) patients. Comorbidities were more common in patients with long CTOs. Compared with short lesions, long lesions had higher J-CTO score (2.8 ± 1.1 vs. 1.3 ± 1; p < 0.001) and retrograde wiring was more often the initial (15.5% vs. 4.0%; p < 0.001) and successful (22.8% vs. 8.2%; p < 0.001) crossing strategy. Long lesions were more likely to require longer procedure (123 vs. 91 min; p < 0.001) and fluoroscopy (47.1 vs. 32.2 min; p < 0.001) time, larger contrast volume (218 vs. 200 mL; p < 0.001) and higher air kerma radiation dose (2.4 vs. 1.7 Gy; p < 0.001). After adjusting for potential confounders, long lesions were associated with lower technical success (odds ratio [OR]: 0.91 per 10 mm increase; 95% confidence interval [CI]: 0.88, 0.94) and higher major adverse cardiovascular events (MACE) (OR: 1.08 per 10 mm increase; 95% CI: 1.02, 1.15). CONCLUSIONS: CTO PCI of long occlusions is independently associated with lower rates of technical success and higher rates of in-hospital MACE.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Oclusão Coronária/etiologia , Angiografia Coronária/métodos , Sistema de Registros , Doença Crônica
5.
Catheter Cardiovasc Interv ; 102(5): 834-843, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37676010

RESUMO

BACKGROUND: There is limited data on the use of the balloon-assisted subintimal entry (BASE) technique in chronic total occlusion (CTO) percutaneous coronary intervention (PCI). METHODS: We analyzed the baseline clinical and angiographic characteristics and outcomes of 155 CTO PCIs that utilized the BASE technique at 31 US and non-US centers between 2016 and 2023. RESULTS: The BASE technique was used in 155 (7.9%) of 1968 antegrade dissection and re-entry (ADR) cases performed during the study period. The mean age was 66 ± 10 years, 88.9% of the patients were men, and the prevalence of diabetes (44.6%), hypertension (90.5%), and dyslipidemia (88.7%) was high. Compared with 1813 ADR cases that did not use BASE, the target vessel of the BASE cases was more commonly the RCA and less commonly the LAD. Lesions requiring BASE had longer occlusion length (42 ± 23 vs. 37 ± 23 mm, p = 0.011), higher Japanese CTO (J-CTO) (3.4 ± 1.0 vs. 3.0 ± 1.1, p < 0.001) and PROGRESS-CTO (Prospective Global Registry for the Study of Chronic Total Occlusion Intervention chronic total occlusion) (1.8 ± 1.0 vs. 1.5 ± 1.0, p = 0.008) scores, and were more likely to have proximal cap ambiguity, side branch at the proximal cap, blunt/no stump, moderate to severe calcification, and proximal tortuosity. Technical (71.6% vs. 75.5%, p = 0.334) and procedural success (71.6% vs. 72.8%, p = 0.821), as well as major adverse cardiac events (MACE) (1.3% vs. 4.1%, p = 0.124), were similar in ADR cases that used BASE and those that did not. CONCLUSIONS: The BASE technique is used in CTOs with longer occlusion length, higher J-CTO score, and more complex angiographic characteristics, and is associated with moderate success but also low MACE.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento , Estudos Prospectivos , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Oclusão Coronária/etiologia , Doença Crônica , Sistema de Registros , Fatores de Risco
6.
Catheter Cardiovasc Interv ; 102(5): 857-863, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37681964

RESUMO

BACKGROUND: The impact of preprocedural anemia on the outcomes of chronic total occlusion (CTO) percutaneous coronary intervention (PCI) has received limited study. METHODS: We examined the clinical and angiographic characteristics and procedural outcomes of 8633 CTO PCIs performed at 39 US and non-US centers between 2012 and 2023. Anemia was defined as a hemoglobin level of <13 g/dL in men and <12 g/dL in women. RESULTS: Anemia was present in 1652 (19%) patients undergoing CTO PCI. Anemic patients had a higher incidence of comorbidities, such as diabetes mellitus, hypertension, dyslipidemia, heart failure, cerebrovascular disease, and peripheral arterial disease. CTOs in anemic patients were more likely to have complex angiographic characteristics, including smaller diameter, longer length, moderate to severe calcification, and moderate to severe proximal tortuosity. Anemic patients required longer procedure (119 vs. 107 min; p < 0.001) and fluoroscopy (45 vs. 40 min; p < 0.001) times but received similar contrast volumes. Technical success was similar between the two groups. In-hospital major adverse cardiac events (MACE) rates were higher in patients with anemia; however, this association was no longer significant after adjusting for confounding factors. Baseline anemia was independently associated with follow-up MACE (adjusted hazard ratio [HR]: 1.63; 95% confidence interval [CI]: 1.07-2.49; p = 0.023) and all-cause mortality (adjusted HR: 3.03; 95% CI: 1.41-6.49; p = 0.004). CONCLUSIONS: Preprocedural anemia is associated with more comorbidities, higher lesion complexity, longer procedure times, and higher follow-up MACE and mortality after CTO PCI.


Assuntos
Anemia , Oclusão Coronária , Intervenção Coronária Percutânea , Masculino , Humanos , Feminino , Resultado do Tratamento , Seguimentos , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Oclusão Coronária/complicações , Fatores de Risco , Doença Crônica , Fatores de Tempo , Angiografia Coronária/efeitos adversos , Anemia/complicações , Anemia/diagnóstico , Hospitais , Sistema de Registros
7.
Catheter Cardiovasc Interv ; 102(1): 56-63, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37172209

RESUMO

BACKGROUND: Aortocoronary dissection is a potentially serious complication of chronic total occlusion (CTO) percutaneous coronary intervention (PCI). METHODS: We examined the incidence, mechanisms, treatment, and outcomes of aortocoronary dissection among 12,117 CTO PCIs performed between 2012 and 2022 in a large multicenter CTO PCI registry. RESULTS: The incidence of aortocoronary dissection was 0.2% (n = 27). Most aortocoronary dissections occurred in the right coronary artery (96.3%, n = 26). The baseline clinical characteristics of patients with and without aortocoronary dissection were similar, except for dyslipidemia, which was less common in patients with aortocoronary dissection (70.4% vs. 86.0%; p = 0.019). The retrograde approach was used more commonly among cases complicated by aortocoronary dissection (59.3% vs. 31.0%; p = 0.002). Technical (74.1% vs. 86.6%; p = 0.049) and procedural (70.4% vs. 85.2%; p = 0.031) success rates were lower among aortocoronary dissection cases, with a similar incidence of in-hospital major adverse cardiovascular events (3.7% vs. 2.0%; p = 0.541). Of the 27 patients with aortocoronary dissection, 19 (70.4%) were treated with ostial stenting and 8 (29.6%) were treated conservatively without subsequent adverse clinical outcomes. No patients required emergency surgery. Follow-up was available for 22 patients (81.5%): during a mean follow up of 767 (±562) days, the incidence of in-stent restenosis was 11.1% (n = 3). CONCLUSIONS: Aortocoronary dissection occurred in 0.2% of CTO PCIs performed by experienced operators, was associated with lower technical and procedural success, and was treated most commonly with ostial stenting. None of the patients required emergency cardiac surgery.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Oclusão Coronária/terapia , Angiografia Coronária , Resultado do Tratamento , Sistema de Registros , Doença Crônica
8.
Catheter Cardiovasc Interv ; 101(6): 1028-1035, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36960766

RESUMO

BACKGROUND: Same day discharge (SDD) following chronic total occlusion (CTO) percutaneous coronary intervention (PCI) has received limited study. METHODS: We evaluated the clinical, angiographic, and procedural characteristics of patients discharged the same day versus those kept for overnight observation in the Prospective Global Registry for the Study of Chronic Total Occlusion Intervention (PROGRESS-CTO, NCT02061436). RESULTS: Of the 7181 patients who underwent CTO PCI, 943 (13%) had SDD. The SDD rate increased from 3% in 2015 to 21% in 2022. Patients with SDD were less likely to have a history of heart failure (21% vs. 26%, p = 0.005), chronic lung disease (10% vs. 15%, p = 0.001), or anemia (12% vs. 19%, p < 0.001). Technical success (87% vs. 88%, p = 0.289) was similar, but in-hospital major adverse cardiovascular events (0.0% vs. 0.4%, p = 0.041) were lower in SDD. In multivariable logistic regression analysis, prior myocardial infarction odds ratio (OR): 0.71 (95% confidence interval [CI]: 0.59-0.87, p = 0.001), chronic lung disease OR: 0.64 (95% CI: 0.47-0.88, p = 0.006), and increasing procedure time OR: 0.93 (95% CI: 0.91-0.95, p < 0.001, per 10-min increase) were associated with overnight observation, while radial-only access OR: 2.45 (95% CI: 2.03-2.96, p < 0.001) had the strongest association with SDD. In the SDD, 2 (0.4%) of 514 patients were readmitted, due to retroperitoneal bleeding (n = 1) and ischemic stroke (n = 1). CONCLUSION: The overall frequency of SDD after CTO PCI was 13% and has been increasing over time. SDD is feasible in select patients following CTO PCI, and radial-only access had the strongest association with SDD.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Alta do Paciente , Fatores de Risco , Resultado do Tratamento , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Oclusão Coronária/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Fatores de Tempo , Doença Crônica , Angiografia Coronária , Sistema de Registros
9.
Catheter Cardiovasc Interv ; 102(4): 585-593, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37560823

RESUMO

BACKGROUND: Donor vessel injury is a potentially life-threatening complication of chronic total occlusion (CTO) percutaneous coronary intervention (PCI). AIMS: Our goal was to examine the incidence, mechanisms, treatment, and outcomes of patients with donor vessel injury in a large multicenter CTO PCI registry. METHODS: We analyzed the baseline clinical and angiographic characteristics, and procedural outcomes of 12,349 CTO PCIs performed between 2012 and 2022 at 44 centers. RESULTS: The incidence of donor vessel injury was 0.35% (n = 43). The baseline clinical characteristics of patients with and without donor vessel injury were similar. Cases complicated by donor vessel injury were more complex with higher Japanese CTO score (2.9 ± 1.1 vs. 2.4 ± 1.3; p = 0.004) and lower procedural success rate (69.8% vs. 85.2%; p = 0.004). The retrograde approach was used more commonly in donor vessel injury cases (68.9% vs. 30.9%; p < 0.001). Most (53.5%) donor vessel injuries were guide catheter-induced, whereas 20.9% were due to donor vessel thrombosis. Of the 43 patients with donor vessel injury, 36 (83.7%) were treated with stenting and seven (16.3%) received a left ventricular assist device. The incidence of major adverse cardiovascular events (MACEs) was significantly higher in cases with donor vessel injury (23.3% vs. 2.0%; p < 0.001). Of the 43 patients with donor vessel injury, five patients (11.6%) experienced acute myocardial infarction and four patients (9.3%) died. CONCLUSIONS: Donor vessel injury, occurred in 0.35% of CTO PCIs performed by experienced operators, was mainly due to guide catheter-induced dissection or thrombosis and was associated with lower procedural success and higher MACE.

10.
Artigo em Inglês | MEDLINE | ID: mdl-36617391

RESUMO

BACKGROUND: Coronary artery perforation is one of the most feared and common complications of chronic total occlusion (CTO) percutaneous coronary intervention (PCI). METHODS: To assess the usefulness of the recently developed PROGRESS-CTO (NCT02061436) perforation risk score in independent cohorts. Individual patient-level data pooled analysis of three registries was performed. RESULTS: Of the 4566 patients who underwent CTO PCI at 25 centers, 196 (4.2%) had coronary artery perforation. Patients with perforations were older (69 ± 10 vs. 65 ± 10, p < 0.001), more likely to be women (19% vs. 13%, p = 0.009), more likely to have a history of prior coronary artery bypass graft (34% vs. 20%, p < 0.001), and unfavorable angiographic characteristics such as blunt stump (62% vs. 48%, p < 0.001), proximal cap ambiguity (52% vs. 34%, p < 0.001), and moderate-severe calcification (60% vs. 49%, p = 0.002). Technical success was lower in patients with perforations (73% vs. 88%, p < 0.001). The area under the receiver operating characteristic curve of the PROGRESS-CTO perforation risk model was 0.76 (95% confidence interval [CI], 0.72-0.79), with good calibration (Hosmer-Lemeshow p = 0.97). We found that the CTO PCI perforation risk increased with higher PROGRESS-CTO perforation scores: 0.3% (score 0), 2.3% (score 1), 3.1% (score 2), 5.5% (score 3), 7.5% (score 4), 14.6% (score 5). CONCLUSION: Given the good discriminative performance, calibration, and the ease of calculation, the PROGRESS-CTO perforation score may facilitate assessment of the risk of perforation in patients undergoing CTO PCI.

11.
Catheter Cardiovasc Interv ; 99(3): 583-592, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34478233

RESUMO

OBJECTIVES: To compare clinical outcomes in high bleeding risk (HBR) patients with and without complex percutaneous coronary intervention (PCI) treated with Resolute Onyx zotarolimus-eluting stents (ZES) after 1-month dual antiplatelet therapy (DAPT). BACKGROUND: PCI with 1-month DAPT has been demonstrated to be safe in HBR patients treated with Resolute Onyx ZES. Whether these outcomes are consistent in patients with complex lesions is uncertain. METHODS: Among HBR patients who were event-free 1 month after PCI with ZES and treated thereafter with single antiplatelet therapy (SAPT), the clinical outcomes between 1 month and 1 year were compared after complex PCI (3 vessels treated, ≥ 3 lesions treated, total stent length > 60 mm, bifurcation with ≥ 2 stents implanted, atherectomy, or left main, surgical bypass graft or chronic total occlusion PCI) versus noncomplex PCI. Propensity score adjustment was performed to adjust for baseline differences among complex and noncomplex patients. RESULTS: Complex patients (N = 401, 26.6% of total) had a higher prevalence of hyperlipidemia, diabetes mellitus and previous myocardial infarction (MI). Between 1 month and 1 year, rates of MI (7.1% vs. 4.0%, p = 0.02) and cardiac death/MI (9.3% vs. 6.1%, p = 0.04) were higher among complex versus noncomplex patients, although stent thrombosis rates were similar. After adjustment for baseline characteristics, differences in outcomes were no longer significant between groups. CONCLUSIONS: Higher rates of ischemic outcomes in complex PCI patients were largely explained by baseline clinical differences, rather than lesion complexity, among HBR patients treated with 1-month DAPT following PCI with Resolute Onyx ZES.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/terapia , Stents Farmacológicos/efeitos adversos , Terapia Antiplaquetária Dupla/efeitos adversos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária , Resultado do Tratamento
12.
Lancet ; 395(10234): 1444-1451, 2020 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-32234534

RESUMO

BACKGROUND: Catheter-based renal denervation has significantly reduced blood pressure in previous studies. Following a positive pilot trial, the SPYRAL HTN-OFF MED (SPYRAL Pivotal) trial was designed to assess the efficacy of renal denervation in the absence of antihypertensive medications. METHODS: In this international, prospective, single-blinded, sham-controlled trial, done at 44 study sites in Australia, Austria, Canada, Germany, Greece, Ireland, Japan, the UK, and the USA, hypertensive patients with office systolic blood pressure of 150 mm Hg to less than 180 mm Hg were randomly assigned 1:1 to either a renal denervation or sham procedure. The primary efficacy endpoint was baseline-adjusted change in 24-h systolic blood pressure and the secondary efficacy endpoint was baseline-adjusted change in office systolic blood pressure from baseline to 3 months after the procedure. We used a Bayesian design with an informative prior, so the primary analysis combines evidence from the pilot and Pivotal trials. The primary efficacy and safety analyses were done in the intention-to-treat population. This trial is registered at ClinicalTrials.gov, NCT02439749. FINDINGS: From June 25, 2015, to Oct 15, 2019, 331 patients were randomly assigned to either renal denervation (n=166) or a sham procedure (n=165). The primary and secondary efficacy endpoints were met, with posterior probability of superiority more than 0·999 for both. The treatment difference between the two groups for 24-h systolic blood pressure was -3·9 mm Hg (Bayesian 95% credible interval -6·2 to -1·6) and for office systolic blood pressure the difference was -6·5 mm Hg (-9·6 to -3·5). No major device-related or procedural-related safety events occurred up to 3 months. INTERPRETATION: SPYRAL Pivotal showed the superiority of catheter-based renal denervation compared with a sham procedure to safely lower blood pressure in the absence of antihypertensive medications. FUNDING: Medtronic.


Assuntos
Hipertensão/cirurgia , Rim/inervação , Rim/cirurgia , Adulto , Anti-Hipertensivos/normas , Austrália/epidemiologia , Áustria/epidemiologia , Teorema de Bayes , Pressão Sanguínea/fisiologia , Canadá/epidemiologia , Feminino , Alemanha/epidemiologia , Grécia/epidemiologia , Humanos , Hipertensão/diagnóstico , Hipertensão/etnologia , Irlanda/epidemiologia , Japão/epidemiologia , Rim/fisiopatologia , Masculino , Pessoa de Meia-Idade , Placebos/efeitos adversos , Estudos Prospectivos , Simpatectomia/métodos , Resultado do Tratamento , Reino Unido/epidemiologia , Estados Unidos/epidemiologia
13.
Catheter Cardiovasc Interv ; 97(4): 658-667, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32597031

RESUMO

BACKGROUND: We examined guidewire and microcatheter utilization during chronic total occlusion (CTO) percutaneous coronary intervention (PCI). METHODS: We examined device utilization in 2,968 CTO PCIs performed in 2,936 patients at 19 US and two international center between January 2016 and January 2019. RESULTS: The median number of antegrade guidewires used per case declined (5 in 2016 vs 3 in 2019) and was higher in higher complexity lesions (2 in J-CTO 0 vs. 8 in J-CTO 4 or 5 score). In antegrade-only procedures, the most frequently used guidewires were the Pilot 200 (Abbott Vascular, 37%), Fielder XT (Asahi Intecc, 25%) and Gaia third (Asahi Intecc, 18%), while the most commonly used microcatheters were the Turnpike Spiral (Vascular Solutions, 18%) and Turnpike (Vascular Solutions, 16%). Compared with 2012-2015, during 2016-2019 use of novel equipment such as the Gaia guidewires and the Turnpike microcatheters led to decreased use of Confianza Pro 12 (Asahi Intecc) wire and Corsair (Asahi Intecc) family of microcatheters. In retrograde cases, the guidewires most commonly used were the Sion (44%), Pilot 200 (27%) and Fielder FC (26%), while the Corsair/Corsair Pro, Turnpike LP (Vascular Solutions) and Caravel (Asahi Intecc) were the most frequently used microcatheters for collateral crossing (29%, 26% and 22%, respectively). CONCLUSIONS: The most commonly used guidewires during CTO PCI are polymer-jacketed guidewires and the most commonly used microcatheters are torquable microcatheters.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/cirurgia , Utilização de Equipamentos e Suprimentos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Resultado do Tratamento
14.
Catheter Cardiovasc Interv ; 96(1): 145-155, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32061033

RESUMO

Evidence-based recommendations for clinical practice are intended to help health care providers and patients make decisions, minimize inappropriate practice variation, promote effective resource use, improve clinical outcomes, and direct future research. The Society for Cardiovascular Angiography and Interventions (SCAI) has been engaged in the creation and dissemination of clinical guidance documents since the 1990s. These documents are a cornerstone of the society's education, advocacy, and quality improvement initiatives. The publications committee is charged with oversight of SCAI's clinical documents program and has created this manual of standard operating procedures to ensure consistency, methodological rigor, and transparency in the development and endorsement of the society's documents. The manual is intended for use by the publications committee, document writing groups, external collaborators, SCAI representatives, peer reviewers, and anyone seeking information about the SCAI documents program.


Assuntos
Comitês Consultivos/normas , Angiografia/normas , Cateterismo Cardíaco/normas , Procedimentos Endovasculares/normas , Manuais como Assunto/normas , Intervenção Coronária Percutânea/normas , Guias de Prática Clínica como Assunto/normas , Sociedades Médicas/normas , Medicina Baseada em Evidências/normas , Humanos , Redação/normas
15.
Catheter Cardiovasc Interv ; 96(5): 1029-1035, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-31797507

RESUMO

BACKGROUND: When crossing into the distal true lumen fails during chronic total occlusion (CTO) percutaneous coronary intervention (PCI), subintimal plaque modification (SPM) is often performed to restore antegrade flow and facilitate subsequent lesion recanalization. METHODS: Between January 2012 and May 4, 2019, 4,659 CTO PCIs were included in the PROGRESS-CTO registry, of which 935 (20%) had a prior unsuccessful attempt. Of those 935 patients, 119 (13%) had prior SPM. We analyzed the outcomes of the 58 SPM procedures for which data were available, as well as the outcomes of the 60 subsequent CTO PCI attempts. RESULTS: Mean patient age was 67 ± 9 years and 86% were men. Patients had high prevalence of cardiovascular risk factors such as dyslipidemia (91%), hypertension (93%) diabetes (48%), prior PCI (61%), and prior coronary artery bypass graft surgery (47%). The target CTO lesions often had proximal cap ambiguity (54%), moderate/severe calcification (73%), moderate/severe tortuosity (63%), and high J-CTO score (mean 3.2 ± 1.1). The technical and procedural success of subsequent CTO PCI were high (83% for both) with an acceptable rate of in-hospital major adverse cardiovascular events (3.3%). Technical and procedural success were higher for repeat attempts that were performed ≥60 days after the index CTO PCI (94% vs. 69%, p = .015). Median (interquartile range) subsequent procedure time was 147 (100, 215) min, contrast volume was 185 (150, 260) ml, and air kerma radiation dose was 2.5 (1.4, 4.2) Gray. CONCLUSION: Repeat CTO PCI attempts after SPM are associated with high likelihood for successful revascularization with acceptable risks.


Assuntos
Doença da Artéria Coronariana/terapia , Oclusão Coronária/terapia , Intervenção Coronária Percutânea , Placa Aterosclerótica , Idoso , Doença Crônica , Doença da Artéria Coronariana/diagnóstico por imagem , Oclusão Coronária/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
16.
Lancet ; 392(10157): 1530-1540, 2018 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-30266412

RESUMO

BACKGROUND: Previous studies showed more adverse events with coronary bioresorbable vascular scaffolds (BVS) than with metallic drug-eluting stents (DES), although in one randomised trial angina was reduced with BVS. However, these early studies were unmasked, lesions smaller than intended for the scaffold were frequently enrolled, implantation technique was suboptimal, and patients with myocardial infarction, in whom BVS might be well suited, were excluded. METHODS: In the active-controlled, blinded, multicentre, randomised ABSORB IV trial, patients with stable coronary artery disease or acute coronary syndromes aged 18 years or older were recruited from 147 hospitals in five countries (the USA, Germany, Australia, Singapore, and Canada). Enrolled patients were randomly assigned (1:1) to receive polymeric everolimus-eluting BVS (Absorb; Abbott Vascular, Santa Clara, CA, USA) with optimised implantation technique or cobalt-chromium everolimus-eluting stents (EES; Xience; Abbott Vascular, Santa Clara, CA, USA). Randomisation was stratified by diabetic status, whether patients would have been eligible for enrolment in the previous ABSORB III trial, and site. Patients and clinical assessors were masked to randomisation. The primary endpoint was target lesion failure (cardiac death, target vessel myocardial infarction, or ischaemia-driven target lesion revascularisation) at 30 days, tested for non-inferiority with a 2·9% margin for the risk difference. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT02173379, and is closed to accrual. FINDINGS: Between Aug 15, 2014, and March 31, 2017, we screened 18 722 patients for eligibility, 2604 of whom were enrolled. 1296 patients were assigned to BVS, and 1308 patients were assigned to EES. Follow-up data at 30 days and 1 year, respectively, were available for 1288 and 1254 patients with BVS and for 1303 and 1272 patients with EES. Biomarker-positive acute coronary syndromes were present in 622 (24%) of 2602 patients, and, by angiographic core laboratory analysis, 78 (3%) of 2893 of lesions were in very small vessels. Target lesion failure at 30 days occurred in 64 (5·0%) patients assigned to BVS and 48 (3·7%) patients assigned to EES (difference 1·3%, upper 97·5% confidence limit 2·89; one-sided pnon-inferiority=0·0244). Target lesion failure at 1 year occurred in 98 (7·8%) patients assigned to BVS and 82 (6·4%) patients assigned to EES (difference 1·4%, upper 97·5% confidence limit 3·4; one-sided pnon-inferiority=0·0006). Angina, adjudicated by a central events committee at 1 year, occurred in 270 (20·3%) patients assigned to BVS and 274 (20·5%) patients assigned to EES (difference -0·3%, 95% CI -3·4% to 2·9%; one-sided pnon-inferiority=0·0008; two-sided psuperiority=0·8603). Device thrombosis within 1 year occurred in nine (0·7%) patients assigned to BVS and four (0·3%) patients assigned to EES (p=0·1586). INTERPRETATION: Polymeric BVS implanted with optimised technique in an expanded patient population resulted in non-inferior 30-day and 1-year rates of target lesion failure and angina compared with metallic DES. FUNDING: Abbott Vascular.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/terapia , Alicerces Teciduais , Síndrome Coronariana Aguda/terapia , Idoso , Materiais Biocompatíveis , Doença da Artéria Coronariana/patologia , Método Duplo-Cego , Stents Farmacológicos , Everolimo/administração & dosagem , Feminino , Seguimentos , Humanos , Imunossupressores/administração & dosagem , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
17.
Lancet ; 391(10137): 2346-2355, 2018 06 09.
Artigo em Inglês | MEDLINE | ID: mdl-29803589

RESUMO

BACKGROUND: Previous catheter-based renal denervation studies have reported variable efficacy results. We aimed to evaluate safety and blood pressure response after renal denervation or sham control in patients with uncontrolled hypertension on antihypertensive medications with drug adherence testing. METHODS: In this international, randomised, single-blind, sham-control, proof-of-concept trial, patients with uncontrolled hypertension (aged 20-80 years) were enrolled at 25 centres in the USA, Germany, Japan, UK, Australia, Austria, and Greece. Eligible patients had an office systolic blood pressure of between 150 mm Hg and 180 mm Hg and a diastolic blood pressure of 90 mm Hg or higher; a 24 h ambulatory systolic blood pressure of between 140 mm Hg and 170 mm Hg at second screening; and were on one to three antihypertensive drugs with stable doses for at least 6 weeks. Patients underwent renal angiography and were randomly assigned to undergo renal denervation or sham control. Patients, caregivers, and those assessing blood pressure were masked to randomisation assignments. The primary efficacy endpoint was blood pressure change from baseline (measured at screening visit two), based on ambulatory blood pressure measurements assessed at 6 months, as compared between treatment groups. Drug surveillance was used to assess medication adherence. The primary analysis was done in the intention-to-treat population. Safety events were assessed through 6 months as per major adverse events. This trial is registered with ClinicalTrials.gov, number NCT02439775, and follow-up is ongoing. FINDINGS: Between July 22, 2015, and June 14, 2017, 467 patients were screened and enrolled. This analysis presents results for the first 80 patients randomly assigned to renal denervation (n=38) and sham control (n=42). Office and 24 h ambulatory blood pressure decreased significantly from baseline to 6 months in the renal denervation group (mean baseline-adjusted treatment differences in 24 h systolic blood pressure -7·0 mm Hg, 95% CI -12·0 to -2·1; p=0·0059, 24 h diastolic blood pressure -4·3 mm Hg, -7·8 to -0·8; p=0.0174, office systolic blood pressure -6·6 mm Hg, -12·4 to -0·9; p=0·0250, and office diastolic blood pressure -4·2 mm Hg, -7·7 to -0·7; p=0·0190). The change in blood pressure was significantly greater at 6 months in the renal denervation group than the sham-control group for office systolic blood pressure (difference -6·8 mm Hg, 95% CI -12·5 to -1·1; p=0·0205), 24 h systolic blood pressure (difference -7·4 mm Hg, -12·5 to -2·3; p=0·0051), office diastolic blood pressure (difference -3·5 mm Hg, -7·0 to -0·0; p=0·0478), and 24 h diastolic blood pressure (difference -4·1 mm Hg, -7·8 to -0·4; p=0·0292). Evaluation of hourly changes in 24 h systolic blood pressure and diastolic blood pressure showed blood pressure reduction throughout 24 h for the renal denervation group. 3 month blood pressure reductions were not significantly different between groups. Medication adherence was about 60% and varied for individual patients throughout the study. No major adverse events were recorded in either group. INTERPRETATION: Renal denervation in the main renal arteries and branches significantly reduced blood pressure compared with sham control with no major safety events. Incomplete medication adherence was common. FUNDING: Medtronic.


Assuntos
Denervação/métodos , Hipertensão/tratamento farmacológico , Rim/irrigação sanguínea , Artéria Renal/inervação , Angiografia/métodos , Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea/efeitos dos fármacos , Monitorização Ambulatorial da Pressão Arterial/métodos , Monitorização Ambulatorial da Pressão Arterial/tendências , Feminino , Humanos , Hipertensão/cirurgia , Rim/diagnóstico por imagem , Masculino , Adesão à Medicação , Pessoa de Meia-Idade , Artéria Renal/cirurgia , Método Simples-Cego , Resultado do Tratamento
18.
Catheter Cardiovasc Interv ; 94(1): 123-135, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31104353

RESUMO

This article is intended for any physician, administrator, or cardiovascular catheterization laboratory (CCL) staff member who desires a fundamental understanding of finances and economics of CCLs in the United States. The authors' goal is to illuminate general economic principles of CCL operations and provide details that can be used immediately by CCL leaders. Any article on economics in medicine should start by acknowledging the primacy of the principles of medical ethics. While physicians have been trained to act in the best interests of their patients and avoid actions that would harm patients it is vitally important that all professionals in the CCL focus on patients' needs. Caregivers both at the bedside and in the office must consider how their actions will affect not only the patient they are treating at the time, but others as well. If the best interests of a patient were to conflict with any recommendation in this article, the former should prevail. KEY POINTS: To be successful and financially viable under current payment systems, CCL physicians, and managers must optimize the outcomes and efficiency of care by aligning CCL leadership, strategy, organization, processes, personnel, and culture. Optimizing a CCL's operating margin (profitability) requires maximizing revenues and minimizing expenses. CCL managers often focus on expense reduction; they should also pay attention to revenue generation. Expense reduction depends on efficiency (on-time starts, short turn-over time, smooth day-to-day schedules), identifying cost-effective materials, and negotiating their price downward. Revenue optimization requires accurate documentation and coding of procedures, comorbidities, and complications. In fee-for-service and bundled payment reimbursement systems, higher volumes of procedures yield higher revenues. New procedures that improve patient care but are expensive can usually be justified by negotiating with vendors for lower prices and including the "halo effect" of collateral services that accompany the new procedure. Fiscal considerations should never eclipse quality concerns. High quality CCL care that prevents complications, increases efficiency, reduces waste, and eliminates unnecessary procedures represents a win for patients, physicians, and CCL administrators.


Assuntos
Cateterismo Cardíaco/economia , Cardiologia/economia , Comércio/economia , Custos de Cuidados de Saúde , Administração da Prática Médica/economia , Assistência Ambulatorial/economia , Orçamentos , Cateterismo Cardíaco/ética , Cateterismo Cardíaco/normas , Cardiologia/ética , Cardiologia/normas , Comércio/ética , Comércio/normas , Consenso , Análise Custo-Benefício , Custos de Cuidados de Saúde/ética , Custos de Cuidados de Saúde/normas , Reforma dos Serviços de Saúde/economia , Humanos , Renda , Reembolso de Seguro de Saúde/economia , Administração da Prática Médica/ética , Administração da Prática Médica/normas , Estados Unidos
19.
Scand Cardiovasc J ; 53(6): 299-304, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31315473

RESUMO

Objectives. Using composite endpoints and/or only first events in clinical research result in information loss and alternative statistical methods which incorporate recurrent event data exist. We compared information-loss under traditional analyses to alternative models. Design. We conducted a retrospective analysis of patients who underwent percutaneous coronary intervention (Jan2010-Dec2014) and constructed Cox models for a composite endpoint (readmission/death), a shared frailty model for recurrent events, and a joint frailty (JF) model to simultaneously account for recurrent and terminal events and evaluated the impact of heart failure (HF) on the outcome. Results. Among 4901 patients, 2047(41.8%) experienced a readmission or death within 1 year. Of those with recurrent events, 60% had ≥1 readmission and 6% had >4; a total of 121(2.5%) patients died during follow-up. The presence of HF conferred an adjusted Hazard ratio (HR) of 1.32 (95% CI: 1.18-1.47, p < .001) for the risk of composite endpoint (Cox model), 1.44 (95% CI: 1.36-1.52, p < .001) in the frailty model, and 1.34 (95% CI:1.22-1.46, p < .001) in the JF model. However, HF was not associated with death (HR 0.87, 95% CI: 0.52-1.48, p = .61) in the JF model. Conclusions. Using a composite endpoint and/or only the first event yields substantial loss of information, as many individuals endure >1 event. JF models reduce bias by simultaneously providing event-specific HRs for recurrent and terminal events.


Assuntos
Readmissão do Paciente , Intervenção Coronária Percutânea/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/mortalidade , Recidiva , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
Lancet ; 390(10108): 2160-2170, 2017 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-28859944

RESUMO

BACKGROUND: Previous randomised renal denervation studies did not show consistent efficacy in reducing blood pressure. The objective of our study was to evaluate the effect of renal denervation on blood pressure in the absence of antihypertensive medications. METHODS: SPYRAL HTN-OFF MED was a multicentre, international, single-blind, randomised, sham-controlled, proof-of-concept trial. Patients were enrolled at 21 centres in the USA, Europe, Japan, and Australia. Eligible patients were drug-naive or discontinued their antihypertensive medications. Patients with an office systolic blood pressure (SBP) of 150 mm Hg or greater and less than 180 mm Hg, office diastolic blood pressure (DBP) of 90 mm Hg or greater, and a mean 24-h ambulatory SBP of 140 mm Hg or greater and less than 170 mm Hg at second screening underwent renal angiography and were randomly assigned to renal denervation or sham control. Patients, caregivers, and those assessing blood pressure were blinded to randomisation assignments. The primary endpoint, change in 24-h blood pressure at 3 months, was compared between groups. Drug surveillance was done to ensure patient compliance with absence of antihypertensive medication. The primary analysis was done in the intention-to-treat population. Safety events were assessed at 3 months. This study is registered with ClinicalTrials.gov, number NCT02439749. FINDINGS: Between June 25, 2015, and Jan 30, 2017, 353 patients were screened. 80 patients were randomly assigned to renal denervation (n=38) or sham control (n=42) and followed up for 3 months. Office and 24-h ambulatory blood pressure decreased significantly from baseline to 3 months in the renal denervation group: 24-h SBP -5·5 mm Hg (95% CI -9·1 to -2·0; p=0·0031), 24-h DBP -4·8 mm Hg (-7·0 to -2·6; p<0·0001), office SBP -10·0 mm Hg (-15·1 to -4·9; p=0·0004), and office DBP -5·3 mm Hg (-7·8 to -2·7; p=0·0002). No significant changes were seen in the sham-control group: 24-h SBP -0·5 mm Hg (95% CI -3·9 to 2·9; p=0·7644), 24-h DBP -0·4 mm Hg (-2·2 to 1·4; p=0·6448), office SBP -2·3 mm Hg (-6·1 to 1·6; p=0·2381), and office DBP -0·3 mm Hg (-2·9 to 2·2; p=0·8052). The mean difference between the groups favoured renal denervation for 3-month change in both office and 24-h blood pressure from baseline: 24-h SBP -5·0 mm Hg (95% CI -9·9 to -0·2; p=0·0414), 24-h DBP -4·4 mm Hg (-7·2 to -1·6; p=0·0024), office SBP -7·7 mm Hg (-14·0 to -1·5; p=0·0155), and office DBP -4·9 mm Hg (-8·5 to -1·4; p=0·0077). Baseline-adjusted analyses showed similar findings. There were no major adverse events in either group. INTERPRETATION: Results from SPYRAL HTN-OFF MED provide biological proof of principle for the blood-pressure-lowering efficacy of renal denervation. FUNDING: Medtronic.


Assuntos
Ablação por Cateter/métodos , Resistência a Medicamentos , Hipertensão/cirurgia , Simpatectomia/métodos , Adulto , Fatores Etários , Idoso , Anti-Hipertensivos/uso terapêutico , Austrália , Determinação da Pressão Arterial , Europa (Continente) , Feminino , Humanos , Hipertensão/diagnóstico , Hipertensão/tratamento farmacológico , Internacionalidade , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Prognóstico , Valores de Referência , Medição de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Método Simples-Cego , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa