1.
AJR Am J Roentgenol ; 196(4): W476-81, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21427314

RESUMO

OBJECTIVE: The currently used model breast for mammographic dosimetry assessment lacks the flexibility to change dimensions. The aim of this study was to develop an adjustable model breast for mammographic dosimetry assessment of Taiwanese women. MATERIALS AND METHODS: A retrospective review of 4226 craniocaudal (CC) views was conducted. The geometry of the model breast was defined as a semielliptical cylinder. Breast parameters, including compressed breast thickness, chest wall-to-nipple distance, compressed breast width, and percentage glandular content, were measured and analyzed. To validate the adjustable model breast, 44 mammograms were obtained. The expected values from the adjustable model breast were compared with the measured values. RESULTS: The average values of compressed breast thickness, chest wall-to-nipple distance, compressed breast width, and percentage glandular content of the women studied were 4.1 cm, 6.9 cm, 16.9 cm, and 54%, respectively. Variations of chest wall-to-nipple distance, compressed breast width, and percentage glandular content can be expressed as functions of compressed breast thickness, and the adjustable model breast developed was based on compressed breast thickness. The average area of the CC view obtained is a factor of 0.81 lower than that defined by the American College of Radiology protocol. For validation, the difference in average values between the expected and measured did not exceed 0.5 cm in breast dimensions and 6% in percentage glandular content. CONCLUSION: Compressed breast thickness is useful for quantifying dimensions and percentage glandular content of a model breast. The adjustable model breast developed in this study can offer greater flexibility in the determination of breast dimensions for mammographic dosimetry assessment of Taiwanese women.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/anatomia & histologia , Mamografia , Modelos Anatômicos , Adulto , Idoso , Calibragem , Feminino , Humanos , Análise dos Mínimos Quadrados , Pessoa de Meia-Idade , Imagens de Fantasmas , Radiometria , Estudos Retrospectivos , Taiwan
2.
J Digit Imaging ; 24(4): 586-97, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20574767

RESUMO

Most deformation algorithms use a single-value smoother during optimization. We investigate multi-scale regularizations (smoothers) during the multi-resolution iteration of two non-parametric deformable registrations (demons and diffeomorphic algorithms) and compare them to a conventional single-value smoother. Our results show that as smoothers increase, their convergence rate decreases; however, smaller smoothers also have a large negative value of the Jacobian determinant suggesting that the one-to-one mapping has been lost; i.e., image morphology is not preserved. A better one-to-one mapping of the multi-scale scheme has also been established by the residual vector field measures. In the demons method, the multi-scale smoother calculates faster than the large single-value smoother (Gaussian kernel width larger than 0.5) and is equivalent to the smallest single-value smoother (Gaussian kernel width equals to 0.5 in this study). For the diffeomorphic algorithm, since our multi-scale smoothers were implemented at the deformation field and the update field, calculation times are longer. For the deformed images in this study, the similarity measured by mean square error, normal correlation, and visual comparisons show that the multi-scale implementation has better results than large single-value smoothers, and better or equivalent for smallest single-value smoother. Between the two deformable registrations, diffeormophic method constructs better coherence space of the deformation field while the deformation is large between images.


Assuntos
Algoritmos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Artefatos , Simulação por Computador , Humanos , Modelos Teóricos
3.
Diagnostics (Basel) ; 11(11)2021 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-34829438

RESUMO

The correct differential diagnosis of dementia has an important impact on patient treatment and follow-up care strategies. Tc-99m-ECD SPECT imaging, which is low cost and accessible in general clinics, is used to identify the two common types of dementia, Alzheimer's disease (AD) and Lewy body dementia (LBD). Two-stage transfer learning technology and reducing model complexity based on the ResNet-50 model were performed using the ImageNet data set and ADNI database. To improve training accuracy, the three-dimensional image was reorganized into three sets of two-dimensional images for data augmentation and ensemble learning, then the performance of various deep learning models for Tc-99m-ECD SPECT images to distinguish AD/normal cognition (NC), LBD/NC, and AD/LBD were investigated. In the AD/NC, LBD/NC, and AD/LBD tasks, the AUC values were around 0.94, 0.95, and 0.74, regardless of training models, with an accuracy of 90%, 87%, and 71%, and F1 scores of 89%, 86%, and 76% in the best cases. The use of transfer learning and a modified model resulted in better prediction results, increasing the accuracy by 32% for AD/NC. The proposed method is practical and could rapidly utilize a deep learning model to automatically extract image features based on a small number of SPECT brain perfusion images in general clinics to objectively distinguish AD and LBD.

4.
Ann Nucl Med ; 35(8): 889-899, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34076857

RESUMO

OBJECTIVE: To develop a practical method to rapidly utilize a deep learning model to automatically extract image features based on a small number of SPECT brain perfusion images in general clinics to objectively evaluate Alzheimer's disease (AD). METHODS: For the properties of low cost and convenient access in general clinics, Tc-99-ECD SPECT imaging data in brain perfusion detection was used in this study for AD detection. Two-stage transfer learning based on the Inception v3 network model was performed using the ImageNet dataset and ADNI database. To improve training accuracy, the three-dimensional image was reorganized into three sets of two-dimensional images for data augmentation and ensemble learning. The effect of pre-training parameters for Tc-99m-ECD SPECT image to distinguish AD from normal cognition (NC) was investigated, as well as the effect of the sample size of F-18-FDG PET images used in pre-training. The same model was also fine-tuned for the prediction of the MMSE score from the Tc-99m-ECD SPECT image. RESULTS: The AUC values of w/wo pre-training parameters for Tc-99m-ECD SPECT image to distinguish AD from NC were 0.86 and 0.90. The sensitivity, specificity, precision, accuracy, and F1 score were 100%, 75%, 76%, 86%, and 86%, respectively for the training model with 1000 cases of F-18-FDG PET image for pre-training. The AUC values for various sample sizes of the training dataset (100, 200, 400, 800, 1000 cases) for pre-training were 0.86, 0.91, 0.95, 0.97, and 0.97. Regardless of the pre-training condition ECD dataset used, the AUC value was greater than 0.85. Finally, predicting cognitive scores and MMSE scores correlated (R2 = 0.7072). CONCLUSIONS: With the ADNI pre-trained model, the sensitivity and accuracy of the proposed deep learning model using SPECT ECD perfusion images to differentiate AD from NC were increased by approximately 30% and 10%, respectively. Our study indicated that the model trained on PET FDG metabolic imaging for the same disease could be transferred to a small sample of SPECT cerebral perfusion images. This model will contribute to the practicality of SPECT cerebral perfusion images using deep learning technology to objectively recognize AD.


Assuntos
Doença de Alzheimer , Fluordesoxiglucose F18 , Encéfalo , Cisteína/análogos & derivados , Humanos , Masculino , Compostos de Organotecnécio , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada de Emissão de Fóton Único
5.
Sci Rep ; 10(1): 19514, 2020 11 11.
Artigo em Inglês | MEDLINE | ID: mdl-33177616

RESUMO

Time-of-flight dual photon emission computed tomography (TOF-DuPECT) is an imaging system that can obtain radionuclide distributions using time information recorded from two cascade-decay photons. The potential decay locations in the image space, a hyperbolic response curve, can be determined via time-difference-of-arrival (TDOA) estimations from two instantaneous coincidence photons. In this feasibility study, Monte Carlo simulations were performed to generate list-mode coincidence data. A full-ring positron emission tomography-like detection system geometry was built in the simulation environment. A contrast phantom and a Jaszczak-like phantom filled with Selenium-75 (Se-75) were used to evaluate the image quality. A TOF-DuPECT system with varying coincidence time resolution (CTR) was then evaluated. We used the stochastic origin ensemble (SOE) algorithm to reconstruct images from the recorded list-mode data. The results indicate that the SOE method can be successfully employed for the TOF-DuPECT system and can achieve acceptable image quality when the CTR is less than 100 ps. Therefore, the TOF-DuPECT imaging system is feasible. With the improvement of the detector with time, future implementations and applications of TOF-DuPECT are promising. Further quantitative imaging techniques such as attenuation and scatter corrections for the TOF-DuPECT system will be developed in future.

6.
Acad Radiol ; 27(8): e183-e192, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31761665

RESUMO

RATIONALE AND OBJECTIVES: Radiomic analysis of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) images enables the extraction of quantitative information of intratumour heterogeneity. This study investigated whether the baseline 18F-FDG PET/CT radiomics can predict treatment response and survival outcomes in patients with Hodgkin lymphoma (HL). MATERIALS AND METHODS: Thirty-five patients diagnosed with HL who underwent 18F-FDG PET/CT scans before and during chemotherapy were retrospectively enrolled in this investigation. For each patient, we extracted 709 radiomic features from pretreatment PET/CT images. Clinical variables (age, gender, B symptoms, bulky tumor, and disease stage) and radiomic signatures (intensity, texture, and wavelet) were analyzed according to response to therapy, progression-free survival (PFS), and overall survival (OS). Receiver operating characteristic curve, logistic regression, and Cox proportional hazards model were used to examine potential predictive and prognostic factors. RESULTS: High-intensity run emphasis (HIR) of PET and run-length nonuniformity (RLNU) of CT extracted from gray-level run-length matrix (GLRM) in high-frequency wavelets were independent predictive factors for the treatment response (odds ratio [OR] = 36.4, p = 0.014; OR = 30.4, p = 0.020). Intensity nonuniformity (INU) of PET and wavelet short run emphasis (SRE) of CT from GLRM and Ann Arbor stage were independently related to PFS (hazard ratio [HR] = 9.29, p = 0.023; HR = 18.40, p = 0.012; HR = 7.46, p = 0.049). Zone-size nonuniformity (ZSNU) of PET from gray-level size zone matrix (GLSZM) was independently associated with OS (HR = 41.02, p = 0.001). Based on these factors, a prognostic stratification model was devised for the risk stratification of patients. The proposed model allowed the identification of four risk groups for PFS and OS (p < 0.001 and p < 0.001). CONCLUSION: HIR_GLRMPET and RLNU_GLRMCT in high-frequency wavelets serve as independent predictive factors for treatment response. ZSNU_GLSZMPET, INU_GLRMPET, and wavelet SRE_GLRMCT serve as independent prognostic factors for survival outcomes. The present study proposes a prognostic stratification model that may be clinically beneficial in guiding risk-adapted treatment strategies for patients with HL.


Assuntos
Fluordesoxiglucose F18 , Doença de Hodgkin , Doença de Hodgkin/diagnóstico por imagem , Doença de Hodgkin/tratamento farmacológico , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Prognóstico , Estudos Retrospectivos
7.
PLoS One ; 14(4): e0210626, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30947267

RESUMO

Nine patients with recurrent head and neck (H&N) cancer received boron neutron capture therapy (BNCT) in one fraction at the Tsing-Hua Open pool reactor (THOR) utilizing the THORplan treatment planning system (TPS). The aims of the present study were to evaluate the use of intensity modulated radiation therapy (IMRT) of 45 Gy in 20 fractions to compensate for the dose heterogeneity in gross tumor volume observed with single-fraction BNCT with mean prescription dose 19 Gy (w), and to evaluate planning quality indices of simulated BNCT+IMRT versus single-fraction BNCT alone. All IMRT plans were generated using the Eclipse TPS which employs the analytical anisotropic algorithm. The conformity index for the gross tumor volume (GTV) was better for the BNCT+IMRT plan than for the BNCT-alone plan (p = 0.003). In addition, the BNCT+IMRT plan provided significantly better homogeneity in the GTV (p = 0.03). The cold spots in inhomogeneous dose distribution in the BNCT plan may be a key factor for H&N cancer recurrence. Our results suggest that single-fraction BNCT combined with compensated multi-fraction IMRT improves treatment homogeneity and conformity than single-fraction BNCT alone, especially for tumor volumes >100 cm3, and possibly increases local tumor control.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias de Cabeça e Pescoço/radioterapia , Recidiva Local de Neoplasia/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada , Terapia Combinada/métodos , Fracionamento da Dose de Radiação , Estudos de Viabilidade , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Carga Tumoral/efeitos da radiação
8.
Phys Med Biol ; 64(15): 155020, 2019 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-31181555

RESUMO

An origin ensemble (OE) image reconstruction algorithm can be used for the fast reconstruction of unconventional geometrical images, e.g. in a Compton camera (CC) system. Due to the low-count rate in the emission data, the reconstructed image is often noisy and inhomogeneous in density. In this study, we propose a way to smooth out the noise in the OE algorithm. During the OE reconstruction, the algorithm stochastically modifies the current location to a random new voxel along the probable corresponding curve of each event depending on the relative event density of the new and old locations. In the original OE technique, the event density is simply the number of events in the voxel. In the proposed method, the event density is estimated from the filtering of a kernel window centered on the voxel. Incorporating the regional filtering is similar to performing an OE algorithm on a smoothed image at each iteration and enables the reconstruction of a smoother image. A Flangeless Esser PET phantom and a multi-activity phantom are used to study the property of the new reconstruction algorithm. The results indicate that the proposed method performs better than a conventional OE algorithm in terms of normalized mean square error (NMSE) and structural similarity (SSIM). Both contrast noise ratio (CNR) and reconstruction accuracy of the new method are better than the conventional OE algorithm and their performances improve with the increase of object size. The median-OE possesses the highest overall image quality and recovery rate among the three filter-OE algorithms and is the method of choice for image reconstruction. Comparing to conventional post-smoothing OEs, the NMSE of median-OE improves 57.6% (46.9%) and the SSIM increased by 73.2% (51.1%) for the Esser (multi-activity) phantom. The proposed OE algorithm is simple and efficient for noise smoothing without complex calculations and highly suited for low-count cases.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Humanos , Imagens de Fantasmas , Probabilidade , Razão Sinal-Ruído
9.
Clin Nucl Med ; 44(10): e559-e565, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31306204

RESUMO

PURPOSE: This study investigated whether a radiomic analysis of pretreatment F-FDG PET can predict prognosis in patients with Hodgkin lymphoma (HL). METHODS: Forty-two patients who were diagnosed as having HL and underwent pretreatment F-FDG PET scans were retrospectively enrolled. For each patient, we extracted 450 radiomic features from PET images. The prognostic significance of the clinical and radiomic features was assessed in relation to progression-free survival (PFS) and overall survival (OS). Receiver operating characteristic curve, Cox proportional hazards regression, and Kaplan-Meier analyses were performed to examine the potential independent predictors and to evaluate the predictive value. RESULTS: Intensity nonuniformity extracted from a gray-level run-length matrix and the Ann Arbor stage were independently associated with PFS (hazard ratio [HR] = 22.8, P < 0.001; HR = 7.6, P = 0.024) and OS (HR = 14.5, P = 0.012; HR = 8.5, P = 0.048), respectively. In addition, SUV kurtosis was an independent prognosticator for PFS (HR = 6.6, P = 0.026). We devised a prognostic scoring system based on these 3 risk predictors. The proposed scoring system further improved the risk stratification of the current staging classification (P < 0.001). CONCLUSIONS: The radiomic feature intensity nonuniformity is an independent prognostic predictor of PFS and OS in patients with HL. We devised a prognostic scoring system, which may be more beneficial for patient risk stratification in guiding therapy compared with the current Ann Arbor staging system.


Assuntos
Fluordesoxiglucose F18 , Doença de Hodgkin/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Doença de Hodgkin/terapia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Modelos de Riscos Proporcionais , Curva ROC , Estudos Retrospectivos , Adulto Jovem
10.
Biomed Res Int ; 2018: 5826174, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30364042

RESUMO

Unlike conventional photon radiotherapy, sophisticated patient positioning tools are not available for boron neutron capture therapy (BNCT). Thus, BNCT remains vulnerable to setup errors and intra-fractional patient motion. The aim of this study was to estimate the impact of deviations in positioning on the dose administered by BNCT for brain tumors at the Tsing Hua open-pool reactor (THOR). For these studies, a simulated head model was generated based on computed tomography (CT) images of a patient with a brain tumor. A cylindrical brain tumor 3 cm in diameter and 5 cm in length was modeled at distances of 6.5 cm and 2.5 cm from the posterior scalp of this head model (T6.5 cm and T2.5 cm, respectively). Radiation doses associated with positioning errors were evaluated for each distance, including left and right shifts, superior and inferior shifts, shifts from the central axis of the beam aperture, and outward shifts from the surface of the beam aperture. Rotational and tilting effects were also evaluated. The dose prescription was 20 Gray-equivalent (Gy-Eq) to 80 % of the tumor. The treatment planning system, NCTPlan, was used to perform dose calculations. The average decreases in mean tumor dose for T6.5 cm for the 1 cm, 2 cm, and 3 cm lateral shifts composed by left, right, superior, and inferior sides, were approximately 1 %, 6 %, and 11 %, respectively, compared to the dose administered to the initial tumor position. The decreases in mean tumor dose for T6.5 cm were approximately 5 %, 11 %, and 15 % for the 1 cm, 2 cm, and 3 cm outward shifts, respectively. For a superficial tumor at T2.5cm, no significant decrease in average mean tumor dose was observed following lateral shifts of 1 cm. Rotational and tilting up to 15° did not result in significant difference to the tumor dose. Dose differences to the normal tissues as a result of the shifts in positioning were also minimal. Taken together, these data demonstrate that the mean dose administered to tumors at greater depths is potentially more vulnerable to deviations in positioning, and greater shift distances resulted in reduced mean tumor doses at the THOR. Moreover, these data provide an estimation of dose differences that are caused by setup error or intra-fractional motion during BNCT, and these may facilitate more accurate predictions of actual patient dose in future treatments.


Assuntos
Terapia por Captura de Nêutron de Boro/métodos , Neoplasias Encefálicas/radioterapia , Cabeça/efeitos da radiação , Humanos , Método de Monte Carlo , Posicionamento do Paciente/métodos , Imagens de Fantasmas , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
11.
J Neural Eng ; 15(6): 065004, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30190446

RESUMO

The use of optogenetics or photobiomodulation in non-human primate (NHP) requires the ability to noninvasively stimulate large and deep cortical brain tissues volumes. In this context, the optical and geometrical parameters of optodes are critical. Methods and general guidelines to optimize these parameters have to be defined. OBJECTIVE: We propose the design of an optode for safe and efficient optical stimulation of a large volume of NHP cortex, down to 3-5 mm depths without inserting fibers into the cortex. APPROACH: Monte Carlo simulations of optical and thermal transport have been carried out using the Geant4 application for tomographic emission (GATE) platform. Parameters such as the fiber diameter, numerical aperture, number of fibers and their geometrical arrangement have been studied. Optimal hardware parameters are proposed to obtain homogeneous fluence above the fluence threshold for opsin activation without detrimental thermal effects. MAIN RESULTS: The simulations show that a large fiber diameter and a large numerical aperture are preferable since they allow limiting power concentration and hence the resulting thermal increases at the brain surface. To obtain a volume of 200-500 mm3 of brain tissues receiving a fluence above the opsin activation threshold for optogenetics or below a phototocixity threshold for photobiomodulation, a 4 fibers configuration is proposed. The optimal distance between the fibers was found to be 4 mm. A practical implementation of the optode has been performed and the corresponding fluence and thermal maps have been simulated. SIGNIFICANCE: The present study defines a method to optimize the design of optode and the choice of stimulation parameters for optogenetics and more generally light delivery to deep and large volumes of tissues in NHP brain with a controlled irradiance dosimetry. The general guidelines are the use of silica fibers with a large numerical aperture and a large diameter. The combination of several fibers is required if large volumes need to be stimulated while avoiding thermal effects.


Assuntos
Córtex Cerebral/fisiologia , Optogenética/instrumentação , Estimulação Luminosa/instrumentação , Primatas/fisiologia , Animais , Simulação por Computador , Temperatura Alta , Fibras Minerais , Método de Monte Carlo , Córtex Motor/fisiologia , Opsinas/metabolismo , Optogenética/métodos , Estimulação Luminosa/métodos , Estimulação Física
12.
Phys Med Biol ; 52(14): 4227-44, 2007 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-17664605

RESUMO

An effective fluence concept was employed to make forward dose calculations to investigate the effects of a distorted fluence map on dose plans. Fluence changes caused by organ motion were calculated using Chui's algorithm (2003 Med. Phys. 30 1736). In two test cases with various fluence maps, the effects of motion were simulated using a maximal displacement from 5 mm to 25 mm; 108 fluence maps that were calculated from 16 IMRT plans for eight liver cancer patients were analyzed and compared with and without gating. Fluoroscopic measurements were made of a moving diaphragm in this study. Fluence changes associated with superior-inferior organ motion, perpendicular to the moving MLC, were also examined. The effects of motion on the fluence maps were evaluated from both the fluence differences between static and motion and the chi function. The maximum displacements of the organs in all of these cases were analyzed and correlated with the change in fluence generated from the liver IMRT plans. The dosimetric effects on the target coverage were evaluated for each plan. The results indicate that, for the same fluence map, the mean fluence intensity error or the percentage of the fluence points that have an unacceptable error is linearly related to the extent of motion. For different fluence maps, the degree to which the fluence is distorted by motion is strongly related to the product of the motion extent and the fluence gradient in the direction of diaphragm motion. For eight liver patients and 16 IMRT plans in this work (with gated technique, motion extent from 0.5 cm to 1.0 cm; without gated technique, motion extent from 0.9 cm to 1.8 cm), the fluence modulations are mild, such that the respiratory motion of each patient did not strongly affect the CTV coverage. The mean dose error is 1.5% for free motion (0.9-1.8 cm) and is around 1% for gated motion (0.5-1 cm).


Assuntos
Artefatos , Neoplasias Hepáticas/fisiopatologia , Neoplasias Hepáticas/radioterapia , Modelos Biológicos , Movimento , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Mecânica Respiratória , Simulação por Computador , Humanos , Dosagem Radioterapêutica , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Phys Med Biol ; 52(6): 1747-56, 2007 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-17327660

RESUMO

Rheumatoid arthritis is one of the most common epidemic diseases in the world. For some patients, the treatment with steroids or nonsteroidal anti-inflammatory drugs is not effective, thus necessitating physical removal of the inflamed synovium. Alternative approaches other than surgery will provide appropriate disease control and improve the patient's quality of life. In this research, we evaluated the feasibility of conducting boron neutron capture synovectomy (BNCS) with the Tsing Hua open-pool reactor (THOR) as a neutron source. Monte Carlo simulations were performed with arthritic joint models and uncertainties were within 5%. The collimator, reflector and boron concentration were optimized to reduce the treatment time and normal tissue doses. For the knee joint, polyethylene with 40%-enriched Li(2)CO(3) was used as the collimator material, and a rear reflector of 15 cm thick graphite and side reflector of 10 cm thick graphite were chosen. The optimized treatment time was 5.4 min for the parallel-opposed irradiation. For the finger joint, polymethyl methacrylate was used as the reflector material. The treatment time can be reduced to 3.1 min, while skin and bone doses can be effectively reduced by approximately 9% compared with treatment using the graphite reflector. We conclude that using THOR as a treatment modality for BNCS could be a feasible alternative in clinical practice.


Assuntos
Artrite Reumatoide/radioterapia , Terapia por Captura de Nêutron de Boro/instrumentação , Terapia por Captura de Nêutron de Boro/métodos , Nêutrons , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Artrite/patologia , Relação Dose-Resposta à Radiação , Estudos de Viabilidade , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Fótons , Polietileno/química , Qualidade de Vida
14.
Comput Biol Med ; 37(9): 1241-51, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17188677

RESUMO

In this paper, a new technique for contour interpolation between slices is presented. We assumed that contour interpolation is equivalent to the interpolation of a polygon that approximates the object shape. The location of each polygon vertex is characterized by a set of parameters. Polygon interpolation can be performed on these parameters. These interpolated parameters are then used to reconstruct the vertices of the new polygon. Finally, the contour is approximated from this polygon using a cubic spline interpolation. This new technique takes into account the shape, the translation, the size, and the orientation of the object's contours. A comparison with regular shape-based interpolation is made on several object contours. The preliminary results show that this new method yields a better contour and is computationally more efficient than shape-based interpolation. This technique can be applied to gray-level images too. The interpolation result of an MR image does not show artifact of intermediate substance commonly seen in a typical linear gray-level interpolation.


Assuntos
Anatomia Transversal/métodos , Imageamento Tridimensional/métodos , Algoritmos , Encéfalo/anatomia & histologia , Humanos
15.
IEEE Trans Med Imaging ; 36(5): 1094-1105, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28055861

RESUMO

Osteoporosis is a disease characterized by a degradation of bone structures. Various methods have been developed to diagnose osteoporosis by measuring bone mineral density (BMD) of patients. However, BMDs from these methods were not equivalent and were incomparable. In addition, partial volume effect introduces errors in estimating bone volume from computed tomography (CT) images using image segmentation. In this study, a two-compartment model (TCM) was proposed to calculate bone volume fraction (BV/TV) and BMD from CT images. The TCM considers bones to be composed of two sub-materials. Various equivalent BV/TV and BMD can be calculated by applying corresponding sub-material pairs in the TCM. In contrast to image segmentation, the TCM prevented the influence of the partial volume effect by calculating the volume percentage of sub-material in each image voxel. Validations of the TCM were performed using bone-equivalent uniform phantoms, a 3D-printed trabecular-structural phantom, a temporal bone flap, and abdominal CT images. By using the TCM, the calculated BV/TVs of the uniform phantoms were within percent errors of ±2%; the percent errors of the structural volumes with various CT slice thickness were below 9%; the volume of the temporal bone flap was close to that from micro-CT images with a percent error of 4.1%. No significant difference (p >0.01) was found between the areal BMD of lumbar vertebrae calculated using the TCM and measured using dual-energy X-ray absorptiometry. In conclusion, the proposed TCM could be applied to diagnose osteoporosis, while providing a basis for comparing various measurement methods.


Assuntos
Densidade Óssea , Absorciometria de Fóton , Osso e Ossos , Humanos , Tomografia Computadorizada por Raios X
16.
Phys Med Biol ; 62(4): N58-N72, 2017 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-27992385

RESUMO

In this study, we present a new method for estimating the time-activity data using serial timely measurements of thermoluminescent dosimeters (TLDs). The approach is based on the combination of the measurement of surface dose using TLD and Monte Carlo (MC) simulation to estimate the radiopharmaceutical time-activity data. It involves four steps: (1) identify the source organs and outline their contours in computed tomography images; (2) compute the S values on the body surface for each source organ using a MC code; (3) obtain a serial measurement of the dose with numerous TLDs placed on the body surface; (4) solve the dose-activity equation to generate organ cumulative activity for each period of measurement. The activity of each organ at the time of measurement is simply the cumulative activity divided by the timespan between measurements. The usefulness of this method was studied using a MC simulation based on an Oak Ridge National Laboratory mathematical phantom with 18F-FDG filled in six source organs. Numerous TLDs were placed on different locations of the surface and were repeatedly read and replaced. The time-activity curves (TACs) of all organs were successfully reconstructed. Experiments on a physical phantom were also performed. Preliminary results indicate that it is an effective, robust, and simple method for assessing the TAC. The proposed method holds great potential for a range of applications in areas such as targeted radionuclide therapy, pharmaceutical research, and patient-specific dose estimation.


Assuntos
Fluordesoxiglucose F18/farmacocinética , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Compostos Radiofarmacêuticos/farmacocinética , Dosimetria Termoluminescente/métodos , Humanos , Método de Monte Carlo , Tomografia por Emissão de Pósitrons , Fatores de Tempo , Distribuição Tecidual
17.
PLoS One ; 12(6): e0180461, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28662135

RESUMO

Diffuse intrinsic pontine glioma is a very frustrating disease. Since the tumor infiltrates the brain stem, surgical removal is often impossible. For conventional radiotherapy, the dose constraint of the brain stem impedes attempts at further dose escalation. Boron neutron capture therapy (BNCT), a targeted radiotherapy, carries the potential to selectively irradiate tumors with an adequate dose while sparing adjacent normal tissue. In this study, 12 consecutive patients treated with conventional radiotherapy in our institute were reviewed to evaluate the feasibility of BNCT. NCTPlan Ver. 1.1.44 was used for dose calculations. Compared with two and three fields, the average maximal dose to the normal brain may be lowered to 7.35 ± 0.72 Gy-Eq by four-field irradiation. The mean ratio of minimal dose to clinical target volume and maximal dose to normal tissue was 2.41 ± 0.26 by four-field irradiation. A therapeutic benefit may be expected with multi-field boron neutron capture therapy to treat diffuse intrinsic pontine glioma without craniotomy, while the maximal dose to the normal brain would be minimized by using the four-field setting.


Assuntos
Terapia por Captura de Nêutron de Boro/métodos , Neoplasias Encefálicas/radioterapia , Glioma/radioterapia , Adolescente , Adulto , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
18.
Phys Med ; 43: 6-14, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29195564

RESUMO

In this study, we detected brain activity by comparing the overall temporal response of the blood oxygen level referring to hemodynamic response with a modeled hemodynamic response (MHR). However, in a conventional analysis by statistical parametric mapping (SPM) method, the MHR is assumed to be a fixed-response function, which may bias the conclusions about brain activation, such as the shapes of the response curve or the different response delays to stimuli. Therefore, to improve detection efficacy, we applied a spatio-temporal clustering analysis (sTCA) to determine the MHR, which is calculated from the prospective voxels with no a priori information about the experiment design. With the sTCA method, these prospective voxels are detected by the feature with the largest temporal clustering within which these voxels react simultaneously, irrespective of where the variant hemodynamic response occurs. This estimated MHR (eMHR) is then applied to search for brain activation. Preliminary results show that the eMHR signal response closely resembles the real signal response of the target area. Moreover, the activation detection using eMHR method is more sensitive for the human visual and motor tasks than that with the canonical hemodynamic response embedded in the SPM analysis as the default MHR (dMHR). The more precise location of brain activation made possible by the improved sensitivity should provide helpful information about the stimulation of neuron activity.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Oxigênio/sangue , Análise Espaço-Temporal , Adolescente , Adulto , Mapeamento Encefálico , Análise por Conglomerados , Cognição , Feminino , Hemodinâmica , Humanos , Masculino , Adulto Jovem
19.
Comput Med Imaging Graph ; 30(1): 9-15, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16361080

RESUMO

A conventional FCM algorithm does not fully utilize the spatial information in the image. In this paper, we present a fuzzy c-means (FCM) algorithm that incorporates spatial information into the membership function for clustering. The spatial function is the summation of the membership function in the neighborhood of each pixel under consideration. The advantages of the new method are the following: (1) it yields regions more homogeneous than those of other methods, (2) it reduces the spurious blobs, (3) it removes noisy spots, and (4) it is less sensitive to noise than other techniques. This technique is a powerful method for noisy image segmentation and works for both single and multiple-feature data with spatial information.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Encéfalo/patologia , Humanos , Imageamento por Ressonância Magnética , Taiwan
20.
Appl Radiat Isot ; 64(4): 448-54, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16376091

RESUMO

According to government regulations, the emergency planning zone (EPZ) of a nuclear power plant (NPP) must be designated before operation and reevaluated every 5 years. Corresponding emergency response planning (ERP) has to be made in advance to guarantee that all necessary resources are available under accidental releases of radioisotope. In this study, the EPZ for each of the three operating NPPs, Chinshan, Kuosheng, and Maanshan, in Taiwan was reevaluated using the MELCOR Accident Consequence Code System 2 (MACCS2) developed by Sandia National Laboratory. Meteorological data around the nuclear power plant were collected during 2003. The source term data including inventory, sensible heat content, and timing duration, were based on previous PRA information of each plant. The effective dose equivalent and thyroid dose together with the related individual risk and societal risk were calculated. By comparing the results to the protective action guide and related safety criteria, 1.5, 1.5, and 4.5km were estimated for Chinshan, Kuosheng, and Maanshan NPPs, respectively. We suggest that a radius of 5.0km is a reasonably conservative value of EPZ for each of the three operating NPPs in Taiwan.