Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 331
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Dairy Sci ; 105(6): 5506-5518, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35465991

RESUMO

Objectives were to evaluate the effect of 2 analogs of PGF2α (cloprostenol vs. dinoprost) and 2 doses (1 injection vs. 2 injections) on luteolysis, follicle diameter, hormonal concentrations, and time to ovulation in dairy heifers. Holstein heifers were fitted with automated estrus detection devices and had their estrous cycle synchronized using PGF2α and an intravaginal insert containing progesterone. Heifers detected in estrus were blocked by weight and randomly assigned to 1 of 4 treatments in a 2 × 2 factorial arrangement: cloprostenol on d 7 after estrus (CLOx1; n = 45), cloprostenol on d 7 and 8 after estrus (CLOx2; n = 41), dinoprost on d 7 after estrus (DINx1; n = 43), or dinoprost on d 7 and 8 after estrus (DINx2; n = 44). Treatment with the first injection of PGF2α was defined as experiment d 0. Area and blood flow of corpus luteum (CL) and diameter of follicles >5 mm were recorded every 12 h from d 0 to estrus and every 6 h thereafter until ovulation. Blood was sampled every 6 h from d 0 until ovulation. Heifers treated with cloprostenol had shorter interval to luteolysis (± SEM; CLOx1 = 23.5 ± 2.2, CLOx2 = 22.9 ± 2.2, DINx1 = 32.6 ± 2.7, DINx2 = 26.4 ± 2.1 h); however, time to ovulation was not affected by treatment. A smaller proportion of heifers treated with a single injection of PGF2α underwent luteolysis compared with heifers treated with 2 injections (CLOx1 = 84.6 ± 6.2, CLOx2 = 100.0 ± 0.0, DINx1 = 59.7 ± 9.8, DINx2 = 96.3 ± 2.7%). Proportion of heifers that ovulated was smaller for DINx1 compared with other treatments (CLOx1 = 88.8 ± 5.1, CLOx2 = 100.0 ± 0.0, DINx1 = 55.2 ± 9.7, DINx2 = 94.4 ± 3.4%). Ovulatory follicle diameter was larger for DINx1 (18.2 ± 2.7 mm) compared with DINx2 (17.4 ± 2.7 mm), whereas dose did not affect the diameter of the ovulatory follicle in heifers treated with cloprostenol (CLOx1 = 17.6 ± 2.7 vs. CLOx2 = 17.8 ± 2.8 mm). Among heifers that underwent luteolysis, progesterone concentrations from 18 to 36 h after treatment were lesser in heifers treated with cloprostenol compared with those treated with dinoprost. Type of PGF2α did not affect progesterone concentrations past 36 h from treatment; however, heifers treated with 2 PGF2α injections had lesser progesterone concentrations and CL blood flow from 36 to 72 h after treatment compared with heifers that received a single PGF2α injection.


Assuntos
Dinoprosta , Luteólise , Animais , Bovinos , Cloprostenol/farmacologia , Sincronização do Estro , Feminino , Inseminação Artificial/veterinária , Ovulação , Progesterona
2.
Eur Phys J A Hadron Nucl ; 57(4): 152, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34776778

RESUMO

Psychological bias towards, or away from, prior measurements or theory predictions is an intrinsic threat to any data analysis. While various methods can be used to try to avoid such a bias, e.g. actively avoiding looking at the result, only data blinding is a traceable and trustworthy method that can circumvent the bias and convince a public audience that there is not even an accidental psychological bias. Data blinding is nowadays a standard practice in particle physics, but it is particularly difficult for experiments searching for the neutron electric dipole moment (nEDM), as several cross measurements, in particular of the magnetic field, create a self-consistent network into which it is hard to inject a false signal. We present an algorithm that modifies the data without influencing the experiment. Results of an automated analysis of the data are used to change the recorded spin state of a few neutrons within each measurement cycle. The flexible algorithm may be applied twice (or more) to the data, thus providing the option of sequentially applying various blinding offsets for separate analysis steps with independent teams. The subtle manner in which the data are modified allows one subsequently to adjust the algorithm and to produce a re-blinded data set without revealing the initial blinding offset. The method was designed for the 2015/2016 measurement campaign of the nEDM experiment at the Paul Scherrer Institute. However, it can be re-used with minor modification for the follow-up experiment n2EDM, and may be suitable for comparable projects elsewhere.

3.
Phys Rev Lett ; 125(13): 131803, 2020 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-33034491

RESUMO

We report the first precision measurement of the parity-violating asymmetry in the direction of proton momentum with respect to the neutron spin, in the reaction ^{3}He(n,p)^{3}H, using the capture of polarized cold neutrons in an unpolarized active ^{3}He target. The asymmetry is a result of the weak interaction between nucleons, which remains one of the least well-understood aspects of electroweak theory. The measurement provides an important benchmark for modern effective field theory and potential model calculations. Measurements like this are necessary to determine the spin-isospin structure of the hadronic weak interaction. Our asymmetry result is A_{PV}=[1.55±0.97(stat)±0.24(sys)]×10^{-8}, which has the smallest uncertainty of any hadronic parity-violating asymmetry measurement so far.

4.
Phys Rev Lett ; 124(8): 081803, 2020 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-32167372

RESUMO

We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons. Our measurement stands in the long history of EDM experiments probing physics violating time-reversal invariance. The salient features of this experiment were the use of a ^{199}Hg comagnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic-field changes. The statistical analysis was performed on blinded datasets by two separate groups, while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is d_{n}=(0.0±1.1_{stat}±0.2_{sys})×10^{-26} e.cm.

5.
Dis Esophagus ; 33(1)2020 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-31313807

RESUMO

The positive impact on patient comprehension and improved procedural outcomes when multimedia is utilized to convey instructions preprocedurally has been previously shown for gastrointestinal procedures such as colonoscopy. However, in gastroesophageal reflux testing (GERD), we continue to utilize verbal and written instructions to establish this diagnosis when we use BRAVO pH testing. This is arguably a more complex procedure involving stopping medications, placement of a device, and maintaining an accurate diary for the duration of the testing. We hypothesize that by utilizing multimedia to relay complex textual information, patients will have improved comprehension of periprocedural instructions thereby improving data entry and satisfaction of expectations during the procedure. Prospective randomized study of 120 patients undergoing endoscopic placement of the BRAVO pH monitoring capsule for evaluation of GERD receive either written preoperative instructions (control) or written plus video instructions (video group). A composite comprehension score was calculated using procedure-specific parameters of data entry over the 48-hour monitoring period. Patient satisfaction was evaluated on the basis of a five-point Likert scale. Extent of patient satisfaction was defined by the fulfillment of patient expectations. Exclusion criteria included patients who did not have access to the video or did not complete follow-up. Seventy-eight patients completed all follow-up evaluations. The video group (n = 44) had a significantly higher mean comprehension score when compared to the control group (n = 34) (9.6 ± 1.4 vs. 7.4 ± 2.0, P = 0.01). Overall satisfaction with instructions was significantly higher in the intervention group (91% vs. 47%, p 0.01). We detected no significant difference in comprehension or satisfaction scores in subgroup analyses of the video group comparing patients <65 and ≥65 years of age and by education level. Compared to standard written instructions, video instructions improved patient comprehension based on data evaluation, and satisfaction. Therefore, clinicians should consider incorporation of multimedia instructions to enhance patient periprocedural expectations and understanding of reflux pH testing using the BRAVO procedure.


Assuntos
Monitoramento do pH Esofágico/psicologia , Refluxo Gastroesofágico/diagnóstico , Aceitação pelo Paciente de Cuidados de Saúde/psicologia , Educação de Pacientes como Assunto/métodos , Satisfação do Paciente/estatística & dados numéricos , Idoso , Compreensão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Multimídia , Estudos Prospectivos
6.
Phys Rev Lett ; 121(24): 242002, 2018 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-30608729

RESUMO

We report the first observation of the parity-violating gamma-ray asymmetry A_{γ}^{np} in neutron-proton capture using polarized cold neutrons incident on a liquid parahydrogen target at the Spallation Neutron Source at Oak Ridge National Laboratory. A_{γ}^{np} isolates the ΔI=1, ^{3}S_{1}→^{3}P_{1} component of the weak nucleon-nucleon interaction, which is dominated by pion exchange and can be directly related to a single coupling constant in either the DDH meson exchange model or pionless effective field theory. We measured A_{γ}^{np}=[-3.0±1.4(stat)±0.2(syst)]×10^{-8}, which implies a DDH weak πNN coupling of h_{π}^{1}=[2.6±1.2(stat)±0.2(syst)]×10^{-7} and a pionless EFT constant of C^{^{3}S_{1}→^{3}P_{1}}/C_{0}=[-7.4±3.5(stat)±0.5(syst)]×10^{-11} MeV^{-1}. We describe the experiment, data analysis, systematic uncertainties, and implications of the result.

7.
Phys Rev Lett ; 119(18): 182501, 2017 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-29219591

RESUMO

We report the measurement of the beam-vector and tensor asymmetries A_{ed}^{V} and A_{d}^{T} in quasielastic (e[over →],e^{'}p) electrodisintegration of the deuteron at the MIT-Bates Linear Accelerator Center up to missing momentum of 500 MeV/c. Data were collected simultaneously over a momentum transfer range 0.1

8.
J Dairy Sci ; 98(7): 4685-97, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25935245

RESUMO

There is a daily pattern of feed intake in the dairy cow, and feeding a single total mixed ration results in variation in the amount of fermentable substrate entering the rumen over the day. The object of this study was to determine if feeding multiple rations over the day that complement the pattern of feed intake would stabilize rumen pool sizes and fermentation. Nine ruminally cannulated cows were used in a 3×3 Latin square design with 23-d periods. Diets were a control diet [33.3% neutral detergent fiber (NDF)], a low-fiber diet (LF; 29.6% NDF), and a high-fiber diet (HF; 34.8% NDF). The LF and HF diets were balanced to provide the same nutrient composition as the control diet when cows were fed 3 parts of LF and 7 parts of HF. Cows on the control treatment (CON) were fed at 0900h, cows on the high/low treatment (H/L) were fed HF at 70% of daily offering at 0900h and LF at 30% of daily offering at 2200h, and cows on the low/high (L/H) treatment were fed LF at 30% of daily offering at 0900h and HF at 70% of daily offering at 1300h. All treatments were fed at 110% of daily intake. Preplanned contrasts compared CON with H/L and H/L with L/H. Feeding the LF diet in the evening resulted in a large increase in the amount of feed consumed immediately after feed delivery at that feeding. Rumen digesta starch concentration increased and NDF concentration decreased following feeding of the LF diet in both the L/H and H/L treatments. Starch pool size also increased following feeding of the LF diet in the evening and tended to increase after feeding the LF diet in the morning. Rumen ammonia concentration was increased following feeding of the HF diet in the morning and the LF diet in the evening in the H/L treatment. Additionally, cis-9 C18:1 and cis-9,cis-12 18:2 are higher in concentrate feeds and were increased after feeding the LF diet in both treatments. Trans fatty acid isomers of the normal and alternate biohydrogenation pathways followed a daily pattern, and the H/L treatment increased isomers of the alternate pathway during the overnight period following the evening feeding of the LF diet. Additionally, C17:0 decreased during the overnight period in the H/L treatment. Feeding multiple rations over the day changed feeding behavior, and the combined effect of diet composition and feeding pattern resulted in a change in rumen nutrient pool sizes and fermentation products. Feeding the low-fiber diet in the evening resulted in a large increase in feed intake after feed delivery and did not increase starch intake during the overnight period. The H/L treatment failed to stabilize rumen fermentation because of the shift in the feeding pattern. Feeding strategies that feed multiple diets over the day must integrate diet composition and feeding behavior to achieve the desired effect on rumen nutrient pools and fermentation.


Assuntos
Ração Animal/análise , Bovinos/fisiologia , Fibras na Dieta/metabolismo , Ácidos Graxos Voláteis/metabolismo , Comportamento Alimentar/efeitos dos fármacos , Conteúdo Gastrointestinal/química , Rúmen/fisiologia , Fenômenos Fisiológicos da Nutrição Animal/efeitos dos fármacos , Animais , Dieta/veterinária , Digestão/efeitos dos fármacos , Feminino , Fermentação/efeitos dos fármacos , Concentração de Íons de Hidrogênio , Distribuição Aleatória , Fatores de Tempo
9.
Nature ; 454(7207): 968-70, 2008 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-18719583

RESUMO

The giant elliptical galaxy NGC 1275, at the centre of the Perseus cluster, is surrounded by a well-known giant nebulosity of emission-line filaments, which are plausibly in excess of 10(8) years old. The filaments are dragged out from the centre of the galaxy by radio-emitting 'bubbles' rising buoyantly in the hot intracluster gas, before later falling back. They act as markers of the feedback process by which energy is transferred from the central massive black hole to the surrounding gas. The mechanism by which the filaments are stabilized against tidal shear and dissipation into the surrounding extremely hot (4 x 10(7) K) gas has been unclear. Here we report observations that resolve thread-like structures in the filaments. Some threads extend over 6 kpc, yet are only 70 pc wide. We conclude that magnetic fields in the threads, in pressure balance with the surrounding gas, stabilize the filaments, so allowing a large mass of cold gas to accumulate and delay star formation.

10.
Artigo em Inglês | MEDLINE | ID: mdl-38702202

RESUMO

Disc displacement without reduction (DDwoR) can cause pain and limitations in mouth opening, with a significant impact on function. The optimal management strategy for DDwoR is unclear. Treatments include conservative management such as mandibular manipulation, occlusal splints, and patient education/self-management, as well as arthrocentesis, which is a minimally invasive procedure. The aim of this systematic review and meta-analysis was to ascertain whether there is a role for arthrocentesis in the management of DDwoR. Studies analysing the outcomes pain and maximum mouth opening (MMO) in patients with DDwoR treated by arthrocentesis or occlusal coverage devices were eligible for inclusion. Following a database search, six studies with a total of 343 participants were found to be eligible for analysis (three prospective observational studies, one retrospective observational study, one non-randomized single-blind clinical trial, and one unblinded randomized clinical trial). When compared to occlusal coverage splints, arthrocentesis demonstrated a slight improvement in pain, although this was statistically non-significant (standardized mean difference (SMD) -0.50, 95% confidence interval (CI) -1.04 to 0.05, P = 0.07; I2 = 81%), and a significant improvement in MMO (SMD 0.79 mm, 95% CI 0.24-1.35 mm, P = 0.005; I2 = 79%). However, due to the significant heterogeneity between studies and the high risk of bias, along with the paucity of double-blind randomized controlled clinical trials, definitive conclusions cannot be drawn for this clinical question.

11.
J Hosp Infect ; 144: 75-84, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38040038

RESUMO

BACKGROUND: The contagiousness of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) is known to be linked to the emission of bioaerosols. Thus, aerosol-generating procedures (AGPs) could increase the risk of infection among healthcare workers (HCWs). AIM: To investigate the impact of an aerosol protection box, the SplashGuard Caregiver (SGGC) with suction system, by direct analysis of the presence of viral particles after an AGP, and by using the computational fluid dynamics (CFD) simulation method. METHODS: This prospective observational study investigated HCWs caring for patients with SARS-CoV-2 admitted to an intensive care unit (ICU). Rooms were categorized as: SGCG present and SGCG absent. Virus detection was performed through direct analysis, and using a CFD model to simulate the movement dynamics of airborne particles produced by a patient's respiratory activities. FINDINGS: Of the 67 analyses performed, three samples tested positive on quantitative polymerase chain reaction: one of 33 analyses in the SCCG group (3%) and two of 34 analyses in the non-SGCG group (5.9%). CFD simulations showed that: (1) reduction of the gaps of an SGCG could decrease the number of emitted particles remaining airborne within the room by up to 70%; and (2) positioning HCWs facing the opposite direction to the main air flow would reduce their exposure. CONCLUSIONS: This study documented the presence of SARS-CoV-2 among HCWs in a negative pressure ICU room of an infected patient with or without the use of an SGCG. The simulation will help to improve the design of the SGCG and the positioning of HCWs in the room.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/prevenção & controle , Cuidadores , Estudos Prospectivos , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Aerossóis e Gotículas Respiratórios , Unidades de Terapia Intensiva
12.
Eur Phys J C Part Fields ; 84(1): 18, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38205101

RESUMO

High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optimized procedure results in a residual magnetic field that has been reduced by a factor of two. The ultra-low field is achieved with the full magnetic-field-coil system, and a large vacuum vessel installed, both in the MSR. In the inner volume of ∼1.4m3, the field is now more uniform and below 300 pT. In addition, the procedure is faster and dissipates less heat into the magnetic environment, which in turn, reduces its thermal relaxation time from 12h down to 1.5h.

13.
Eur Phys J C Part Fields ; 83(11): 1061, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38021215

RESUMO

We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron. Magnetic-field stability and control is of key importance for n2EDM. A large, cubic, 5 m side length, magnetically shielded room (MSR) provides a passive, quasi-static shielding-factor of about 105 for its inner sensitive volume. The AMS consists of a system of eight complex, feedback-controlled compensation coils constructed on an irregular grid spanned on a volume of less than 1000 m3 around the MSR. The AMS is designed to provide a stable and uniform magnetic-field environment around the MSR, while being reasonably compact. The system can compensate static and variable magnetic fields up to ±50µT (homogeneous components) and ±5µT/m (first-order gradients), suppressing them to a few µT in the sub-Hertz frequency range. The presented design concept and implementation of the AMS fulfills the requirements of the n2EDM experiment and can be useful for other applications, where magnetically silent environments are important and spatial constraints inhibit simpler geometrical solutions.

14.
Haemophilia ; 18(6): 888-91, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22630567

RESUMO

Patients with bleeding disorders may be exposed to ionizing radiation during medical care. We hypothesized that children with severe haemophilia may have higher radiation exposure than those with mild bleeding disorders (MBDs). To compare medical radiation exposure rates between children with severe haemophilia and MBDs. Charts of 35 pediatric patients with severe haemophilia were randomly selected from a database of active male patients followed in our bleeding disorders clinic from 2000 to 2010. Case patients were age and sex matched with two control patients with MBDs [Type 1 von Willebrand disease (VWD) or mild platelet function defect (PFD)]. By retrospective review, data on radiation exposure in millisieverts (mSv) was collected from radiological studies performed within Emory/CHOA. The rates of exposure between cohorts were compared using the Mann-Whitney Test. Case patients had a mean of 11.3 (median 8, IQR = 29) radiographic studies compared with 1.8 (median 1, IQR = 11) for controls (P < 0.001). The mean effective dose of radiation per patient per year of study was two mSv for case patients (median 0.4, IQR = 3) and 0.4 mSv for control patients (median 0.01, IQR = 0.3) (P < 0.001). Overall, 1.4% of controls and 31.4% of cases accumulated high to very high levels of exposure ( > 20 mSv). Case patients with severe hemophilia accumulated significantly more medical radiation exposure than controls. While the use of ionizing radiation is often necessary for management of these patients, avoidance of unnecessary exposure along with exploration of alternative imaging techniques and low dose protocols should be considered whenever possible.


Assuntos
Hemofilia A/diagnóstico por imagem , Hemofilia B/diagnóstico por imagem , Radiação Ionizante , Doença de von Willebrand Tipo 1/diagnóstico por imagem , Criança , Pré-Escolar , Estudos de Coortes , Humanos , Masculino , Doses de Radiação , Estudos Retrospectivos , Medição de Risco , Tomografia Computadorizada por Raios X
15.
Nephron Exp Nephrol ; 121(1-2): e49-58, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23147410

RESUMO

BACKGROUND: Intracellular calcium (Ca(2+)) plays an important role in normal renal physiology and in the pathogenesis of various kidney diseases; however, the study of Ca(2+) signals in intact tissue has been limited by technical difficulties, including achieving adequate loading of Ca(2+)-sensitive fluorescent dyes. The kidney slice preparation represents a model whereby three-dimensional tissue architecture is preserved and structures in both the cortex and medulla can be imaged using confocal or multiphoton microscopy. METHODS: Ca(2+)-sensitive dyes Rhod-2, Fura-red and Fluo-4 were loaded into tubular and vascular cells in rat kidney slices using a re-circulating perfusion system and real-time imaging of Ca(2+) signals was recorded by confocal microscopy. Kidney slices were also obtained from transgenic mice expressing the GCaMP2 Ca(2+)-sensor in their endothelial cells and real time Ca(2+) transients stimulated by physiological stimuli. RESULTS: Wide spread loading of Ca(2+) indicators was achieved in the tubular and vascular structures of both the medulla and cortex. Real time Ca(2+) signals were successfully recorded in different intracellular compartments of both rat and mouse cortical and medullary tubules in response to physiological stimuli (ATP and angiotensin II). Glomerular Ca(2+) transients were similarly recorded in kidney slices taken from the transgenic mouse expressing the GCaMP2 Ca(2+)-sensor. CONCLUSION: We present new approaches that can be adopted to image cytosolic and mitochondrial Ca(2+) signals within various cell types in intact kidney tissue. Moreover, techniques described in this study can be used to facilitate future detailed investigations of intracellular Ca(2+) homeostasis in renal health and disease.


Assuntos
Sinalização do Cálcio/fisiologia , Cálcio/metabolismo , Rim/fisiologia , Microscopia Confocal/métodos , Microscopia de Fluorescência/métodos , Imagem Molecular/métodos , Animais , Linhagem Celular , Masculino , Camundongos , Camundongos Transgênicos , Ratos , Ratos Sprague-Dawley
16.
Nephron Physiol ; 120(3): p17-31, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22833057

RESUMO

BACKGROUND: Medullary blood flow is via vasa recta capillaries, which possess contractile pericytes. In vitro studies using isolated descending vasa recta show that pericytes can constrict/dilate descending vasa recta when vasoactive substances are present. We describe a live kidney slice model in which pericyte-mediated vasa recta constriction/dilation can be visualized in situ. METHODS: Confocal microscopy was used to image calcein, propidium iodide and Hoechst labelling in 'live' kidney slices, to determine tubular and vascular cell viability and morphology. DIC video-imaging of live kidney slices was employed to investigate pericyte-mediated real-time changes in vasa recta diameter. RESULTS: Pericytes were identified on vasa recta and their morphology and density were characterized in the medulla. Pericyte-mediated changes in vasa recta diameter (10-30%) were evoked in response to bath application of vasoactive agents (norepinephrine, endothelin-1, angiotensin-II and prostaglandin E(2)) or by manipulating endogenous vasoactive signalling pathways (using tyramine, L-NAME, a cyclo-oxygenase (COX-1) inhibitor indomethacin, and ATP release). CONCLUSIONS: The live kidney slice model is a valid complementary technique for investigating vasa recta function in situ and the role of pericytes as regulators of vasa recta diameter. This technique may also be useful in exploring the role of tubulovascular crosstalk in regulation of medullary blood flow.


Assuntos
Capilares/fisiologia , Medula Renal/irrigação sanguínea , Pericitos/fisiologia , Vasoconstrição/fisiologia , Trifosfato de Adenosina/metabolismo , Angiotensina II/metabolismo , Angiotensina II/farmacologia , Animais , Antígenos/metabolismo , Capilares/citologia , Sobrevivência Celular/fisiologia , Endotelina-1/metabolismo , Endotelina-1/farmacologia , Inibidores Enzimáticos/farmacologia , Imuno-Histoquímica , Técnicas In Vitro , Indometacina/farmacologia , Medula Renal/inervação , Medula Renal/metabolismo , Masculino , Microscopia Confocal , NG-Nitroarginina Metil Éster/farmacologia , Norepinefrina/metabolismo , Norepinefrina/farmacologia , Pericitos/citologia , Proteoglicanas/metabolismo , Ratos , Ratos Sprague-Dawley , Transdução de Sinais/efeitos dos fármacos , Sistema Nervoso Simpático/fisiologia , Vasoconstrição/efeitos dos fármacos , Vasoconstritores/metabolismo , Vasoconstritores/farmacologia
17.
J Occup Environ Hyg ; 9(5): 308-18, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22545869

RESUMO

The National Institute for Occupational Safety and Health conducted an initial, task-based comparative assessment to determine the potential for release of carbon nanofibers (CNFs) during dry material handling, wet cutting, grinding, and sanding (by machine and hand) of plastic composite material containing CNFs. Using a combination of direct-reading instruments and filter-based air sampling methods for airborne mass and transmission electron microscopy (TEM), concentrations were measured and characterized near sources of particle generation, in the breathing zone of the workers, and in the general work area. Tasks such as surface grinding of composite material and manually transferring dry CNFs produced substantial increases in particle number concentration (range = 20,000-490,000 1-cm(-3)). Concomitant increases in mass concentration were also associated with most tasks. Nearly 90% of all samples examined via TEM indicated that releases of CNFs do occur and that the potential for exposure exists. These findings also indicate that improperly designed, maintained, or installed engineering controls may not be completely effective in controlling releases. Unprotected skin exposure to CNFs was noted in two instances and indicated the need for educating workers on the need for personal protective equipment. [Supplementary materials are available for this article. Go to the publisher's online edition of Journal of Occupational and Environmental Hygiene for the following free supplemental resource: a PDF file containing information on materials, evaluated processes, personal protective equipment, and existing ventilation/engineering controls.].


Assuntos
Poluentes Ocupacionais do Ar/análise , Exposição por Inalação/análise , Nanofibras/análise , Exposição Ocupacional/análise , Carbono , Monitoramento Ambiental , Humanos , Exposição por Inalação/prevenção & controle , Microscopia Eletrônica de Transmissão , Exposição Ocupacional/prevenção & controle , Roupa de Proteção , Dispositivos de Proteção Respiratória , Ventilação
18.
J Occup Environ Hyg ; 9(9): 543-55, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22816668

RESUMO

In early 2006, the National Institute for Occupational Safety and Health created a field research team whose mission is to visit a variety of facilities engaged in the production, handling, or use of engineered nanomaterials (ENMs) and to conduct initial emission and exposure assessments to identify candidate sites for further study. To conduct the assessments, the team developed the Nanoparticle Emission Assessment Technique (NEAT), which has been used at numerous facilities to sample multiple engineered nanomaterials. Data collected at four facilities, which volunteered to serve as test sites, indicate that specific tasks can release ENMs to the workplace atmosphere and that traditional controls such as ventilation can be used to limit exposure. Metrics such as particle number concentration (adjusted for background), airborne mass concentration, and qualitative transmission electron microscopy were used to determine the presence, nature, and magnitude of emissions and whether engineered nanomaterials migrated to the workers' breathing zone. [Supplementary materials are available for this article. Go to the publisher's online edition of Journal of Occupational and Environmental Hygiene for the following free supplemental resource: a PDF file containing information on facilities, a description of processes/tasks, existing controls, and sampling strategy, and a PDF file containing TEM images according to facility and task.].


Assuntos
Poluentes Ocupacionais do Ar/análise , Monitoramento Ambiental/métodos , Exposição por Inalação/análise , Nanopartículas/análise , Exposição Ocupacional/análise , Monitoramento Ambiental/instrumentação , Humanos , Exposição por Inalação/prevenção & controle , Microscopia Eletrônica de Transmissão , Nanotecnologia , Exposição Ocupacional/prevenção & controle , Ventilação
19.
Rev Sci Instrum ; 93(9): 095105, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36182526

RESUMO

We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute, which features an interior cubic volume with each side of length 2.92 m, thus providing an accessible space of 25 m3. The MSR has 87 openings of diameter up to 220 mm for operating the experimental apparatus inside and an intermediate space between the layers for housing sensitive signal processing electronics. The characterization measurements show a remanent magnetic field in the central 1 m3 below 100 pT and a field below 600 pT in the entire inner volume, up to 4 cm to the walls. The quasi-static shielding factor at 0.01 Hz measured with a sinusoidal 2 µT peak-to-peak signal is about 100 000 in all three spatial directions and increases rapidly with frequency to reach 108 above 1 Hz.

20.
Magn Reson Med ; 66(2): 605-8, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21433067

RESUMO

Laser atomic magnetometry is a portable and low-cost yet highly sensitive method for low magnetic field detection. In this work, the atomic magnetometer was used in a remote-detection geometry to measure the relaxivity of aqueous gadolinium-diethylenetriamine pentaacetic acid Gd(DTPA) at the Earth's magnetic field (40 µT). The measured relaxivity of 9.7±2.0 s(-1) mM(-1) is consistent with field-cycling experiments measured at slightly higher magnetic fields, but no cryogens or strong and homogeneous magnetic field were required for this experiment. The field-independent sensitivity of 80 fT Hz(-1/2) allowed an in vitro detection limit of ∼10 µM Gd(DTPA) to be measured in aqueous buffer solution. The low detection limit and enhanced relaxivity of Gd-containing complexes at Earth's field motivate continued development of atomic magnetometry toward medical applications.


Assuntos
Avaliação Pré-Clínica de Medicamentos/instrumentação , Gadolínio/análise , Gadolínio/química , Espectroscopia de Ressonância Magnética/instrumentação , Magnetometria/instrumentação , Meios de Contraste/análise , Meios de Contraste/química , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa