Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 136
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Int J Legal Med ; 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38862820

RESUMO

In the field of forensic anthropology, researchers aim to identify anonymous human remains and determine the cause and circumstances of death from skeletonized human remains. Sex determination is a fundamental step of this procedure because it influences the estimation of other traits, such as age and stature. Pelvic bones are especially dimorphic, and are thus the most useful bones for sex identification. Sex estimation methods are usually based on morphologic traits, measurements, or landmarks on the bones. However, these methods are time-consuming and can be subject to inter- or intra-observer bias. Sex determination can be done using dry bones or CT scans. Recently, artificial neural networks (ANN) have attracted attention in forensic anthropology. Here we tested a fully automated and data-driven machine learning method for sex estimation using CT-scan reconstructions of coxal bones. We studied 580 CT scans of living individuals. Sex was predicted by two networks trained on an independent sample: a disentangled variational auto-encoder (DVAE) alone, and the same DVAE associated with another classifier (Crecon). The DVAE alone exhibited an accuracy of 97.9%, and the DVAE + Crecon showed an accuracy of 99.8%. Sensibility and precision were also high for both sexes. These results are better than those reported from previous studies. These data-driven algorithms are easy to implement, since the pre-processing step is also entirely automatic. Fully automated methods save time, as it only takes a few minutes to pre-process the images and predict sex, and does not require strong experience in forensic anthropology.

2.
NMR Biomed ; 36(12): e5031, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37797947

RESUMO

In this second part of a two-part paper, we intend to demonstrate the impact of the previously proposed advanced quality control pipeline. To understand its benefit and challenge the proposed methodology in a real scenario, we chose to compare the outcome when applying it to the analysis of two patient populations with significant but highly different types of fatigue: COVID-19 and multiple sclerosis (MS). 31 P-MRS was performed on a 3 T clinical MRI, in 19 COVID-19 patients, 38 MS patients, and 40 matched healthy controls. Dynamic acquisitions using an MR-compatible ergometer ran over a rest (40 s), exercise (2 min), and a recovery phase (6 min). Long and short TR acquisitions were also made at rest for T1 correction. The advanced data quality control pipeline presented in Part 1 is applied to the selected patient cohorts to investigate its impact on clinical outcomes. We first used power and sample size analysis to estimate objectively the impact of adding the quality control score (QCS). Then, comparisons between patients and healthy control groups using the validated QCS were performed using unpaired t tests or Mann-Whitney tests (p < 0.05). The application of the QCS resulted in increased statistical power, changed the values of several outcome measures, and reduced variability (standard deviation). A significant difference was found between the T1PCr and T1Pi values of MS patients and healthy controls. Furthermore, the use of a fixed correction factor led to systematically higher estimated concentrations of PCr and Pi than when using individually corrected factors. We observed significant differences between the two patient populations and healthy controls for resting [PCr]-MS only, [Pi ], [ADP], [H2 PO4 - ], and pH-COVID-19 only, and post-exercise [PCr], [Pi ], and [H2 PO4 - ]-MS only. The dynamic indicators τPCr , τPi , ViPCr , and Vmax were reduced for COVID-19 and MS patients compared with controls. Our results show that QCS in dynamic 31 P-MRS studies results in smaller data variability and therefore impacts study sample size and power. Although QCS resulted in discarded data and therefore reduced the acceptable data and subject numbers, this rigorous and unbiased approach allowed for proper assessment of muscle metabolites and metabolism in patient populations. The outcomes include an increased metabolite T1 , which directly affects the T1 correction factor applied to the amplitudes of the metabolite, and a prolonged τPCr , indicating reduced muscle oxidative capacity for patients with MS and COVID-19.


Assuntos
COVID-19 , Metabolismo Energético , Humanos , Espectroscopia de Ressonância Magnética/métodos , Fosfocreatina/metabolismo , Metabolismo Energético/fisiologia , Músculo Esquelético/metabolismo , COVID-19/metabolismo
3.
NMR Biomed ; 36(12): e5025, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37797948

RESUMO

Implementing a standardized phosphorus-31 magnetic resonance spectroscopy (31 P-MRS) dynamic acquisition protocol to evaluate skeletal muscle energy metabolism and monitor muscle fatigability, while being compatible with various longitudinal clinical studies on diversified patient cohorts, requires a high level of technicality and expertise. Furthermore, processing data to obtain reliable results also demands a great degree of expertise from the operator. In this two-part article, we present an advanced quality control approach for data acquired using a dynamic 31 P-MRS protocol. The aim is to provide decision support to the operator to assist in data processing and obtain reliable results based on objective criteria. We present here, in part 1, an advanced data quality control (QC) approach of a dynamic 31 P-MRS protocol. Part 2 is an impact study that will demonstrate the added value of the QC approach to explore data derived from two clinical populations that experience significant fatigue, patients with coronavirus disease 2019 and multiple sclerosis. In part 1, 31 P-MRS was performed using 3-T clinical MRI in 175 subjects from clinical and healthy control populations conducted in a University Hospital. An advanced data QC score (QCS) was developed using multiple objective criteria. The criteria were based on current recommendations from the literature enriched by new proposals based on clinical experience. The QCS was designed to indicate valid and corrupt data and guide necessary objective data editing to extract as much valid physiological data as possible. Dynamic acquisitions using an MR-compatible ergometer ran over a rest (40 s), exercise (2 min), and a recovery phase (6 min). Using QCS enabled rapid identification of subjects with data anomalies, allowing the user to correct the data series or reject them partially or entirely, as well as identify fully valid datasets. Overall, the use of the QCS resulted in the automatic classification of 45% of the subjects, including 58 participants who had data with no criterion violation and 21 participants with violations that resulted in the rejection of all dynamic data. The remaining datasets were inspected manually with guidance, allowing acceptance of full datasets from an additional 80 participants and recovery phase data from an additional 16 subjects. Overall, more anomalies occurred with patient data (35% of datasets) compared with healthy controls (15% of datasets). In conclusion, the QCS ensures a standardized data rejection procedure and rigorous objective analysis of dynamic 31 P-MRS data obtained from patients. This methodology contributes to efforts made to standardize 31 P-MRS practices that have been underway for a decade, with the goal of making it an empowered tool for clinical research.


Assuntos
Músculo Esquelético , Fósforo , Humanos , Fósforo/química , Músculo Esquelético/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Metabolismo Energético , Imageamento por Ressonância Magnética , Fosfocreatina/metabolismo
4.
J Cardiovasc Magn Reson ; 25(1): 7, 2023 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-36747201

RESUMO

BACKGROUND: Heart failure- (HF) and arrhythmia-related complications are the main causes of morbidity and mortality in patients with nonischemic dilated cardiomyopathy (NIDCM). Cardiovascular magnetic resonance (CMR) imaging is a noninvasive tool for risk stratification based on fibrosis assessment. Diffuse interstitial fibrosis in NIDCM may be a limitation for fibrosis assessment through late gadolinium enhancement (LGE), which might be overcome through quantitative T1 and extracellular volume (ECV) assessment. T1 and ECV prognostic value for arrhythmia-related events remain poorly investigated. We asked whether T1 and ECV have a prognostic value in NIDCM patients. METHODS: This prospective multicenter study analyzed 225 patients with NIDCM confirmed by CMR who were followed up for 2 years. CMR evaluation included LGE, native T1 mapping and ECV values. The primary endpoint was the occurrence of a major adverse cardiovascular event (MACE) which was divided in two groups: HF-related events and arrhythmia-related events. Optimal cutoffs for prediction of MACE occurrence were calculated for all CMR quantitative values. RESULTS: Fifty-eight patients (26%) developed a MACE during follow-up, 42 patients (19%) with HF-related events and 16 patients (7%) arrhythmia-related events. T1 Z-score (p = 0.008) and global ECV (p = 0.001) were associated with HF-related events occurrence, in addition to left ventricular ejection fraction (p < 0.001). ECV > 32.1% (optimal cutoff) remained the only CMR independent predictor of HF-related events occurrence (HR 2.15 [1.14-4.07], p = 0.018). In the arrhythmia-related events group, patients had increased native T1 Z-score and ECV values, with both T1 Z-score > 4.2 and ECV > 30.5% (optimal cutoffs) being independent predictors of arrhythmia-related events occurrence (respectively, HR 2.86 [1.06-7.68], p = 0.037 and HR 2.72 [1.01-7.36], p = 0.049). CONCLUSIONS: ECV was the sole independent predictive factor for both HF- and arrhythmia-related events in NIDCM patients. Native T1 was also an independent predictor in arrhythmia-related events occurrence. The addition of ECV and more importantly native T1 in the decision-making algorithm may improve arrhythmia risk stratification in NIDCM patients. Trial registration NCT02352129. Registered 2nd February 2015-Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT02352129.


Assuntos
Cardiomiopatia Dilatada , Insuficiência Cardíaca , Humanos , Cardiomiopatia Dilatada/patologia , Prognóstico , Volume Sistólico , Miocárdio/patologia , Meios de Contraste , Estudos Prospectivos , Função Ventricular Esquerda , Imagem Cinética por Ressonância Magnética/métodos , Valor Preditivo dos Testes , Gadolínio , Espectroscopia de Ressonância Magnética , Fibrose
5.
Circulation ; 144(11): 859-869, 2021 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-34420373

RESUMO

BACKGROUND: Inflammation is a key factor of myocardial damage in reperfused ST-segment-elevation myocardial infarction. We hypothesized that colchicine, a potent anti-inflammatory agent, may reduce infarct size (IS) and left ventricular (LV) remodeling at the acute phase of ST-segment-elevation myocardial infarction. METHODS: In this double-blind multicenter trial, we randomly assigned patients admitted for a first episode of ST-segment-elevation myocardial infarction referred for primary percutaneous coronary intervention to receive oral colchicine (2-mg loading dose followed by 0.5 mg twice a day) or matching placebo from admission to day 5. The primary efficacy outcome was IS determined by cardiac magnetic resonance imaging at 5 days. The relative LV end-diastolic volume change at 3 months and IS at 3 months assessed by cardiac magnetic resonance imaging were among the secondary outcomes. RESULTS: We enrolled 192 patients, 101 in the colchicine group and 91 in the control group. At 5 days, the gadolinium enhancement-defined IS did not differ between the colchicine and placebo groups with a mean of 26 interquartile range (IQR) [16-44] versus 28.4 IQR [14-40] g of LV mass, respectively (P=0.87). At 3 months follow-up, there was no significant difference in LV remodeling between the colchicine and placebo groups with a +2.4% (IQR, -8.3% to 11.1%) versus -1.1% (IQR, -8.0% to 9.9%) change in LV end-diastolic volume (P=0.49). Infarct size at 3 months was also not significantly different between the colchicine and placebo groups (17 IQR [10-28] versus 18 IQR [10-27] g of LV mass, respectively; P=0.92). The incidence of gastrointestinal adverse events during the treatment period was greater with colchicine than with placebo (34% versus 11%, respectively; P=0.0002). CONCLUSIONS: In this randomized, placebo-controlled trial, oral administration of high-dose colchicine at the time of reperfusion and for 5 days did not reduce IS assessed by cardiac magnetic resonance imaging. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03156816.


Assuntos
Colchicina/uso terapêutico , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio com Supradesnível do Segmento ST/tratamento farmacológico , Remodelação Ventricular/efeitos dos fármacos , Doença Aguda , Adulto , Idoso , Meios de Contraste/farmacologia , Feminino , Coração/efeitos dos fármacos , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Encaminhamento e Consulta
6.
NMR Biomed ; 35(6): e4685, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34967060

RESUMO

Cardiac diffusion tensor imaging (DTI) is an emerging technique for the in vivo characterisation of myocardial microstructure, and there is a growing need for its validation and standardisation. We sought to establish the accuracy, precision, repeatability and reproducibility of state-of-the-art pulse sequences for cardiac DTI among 10 centres internationally. Phantoms comprising 0%-20% polyvinylpyrrolidone (PVP) were scanned with DTI using a product pulsed gradient spin echo (PGSE; N = 10 sites) sequence, and a custom motion-compensated spin echo (SE; N = 5) or stimulated echo acquisition mode (STEAM; N = 5) sequence suitable for cardiac DTI in vivo. A second identical scan was performed 1-9 days later, and the data were analysed centrally. The average mean diffusivities (MDs) in 0% PVP were (1.124, 1.130, 1.113) x 10-3  mm2 /s for PGSE, SE and STEAM, respectively, and accurate to within 1.5% of reference data from the literature. The coefficients of variation in MDs across sites were 2.6%, 3.1% and 2.1% for PGSE, SE and STEAM, respectively, and were similar to previous studies using only PGSE. Reproducibility in MD was excellent, with mean differences in PGSE, SE and STEAM of (0.3 ± 2.3, 0.24 ± 0.95, 0.52 ± 0.58) x 10-5  mm2 /s (mean ± 1.96 SD). We show that custom sequences for cardiac DTI provide accurate, precise, repeatable and reproducible measurements. Further work in anisotropic and/or deforming phantoms is warranted.


Assuntos
Imagem de Tensor de Difusão , Coração , Anisotropia , Imagem de Tensor de Difusão/métodos , Coração/diagnóstico por imagem , Imagens de Fantasmas , Reprodutibilidade dos Testes
7.
Eur Radiol ; 32(7): 4340-4351, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35184220

RESUMO

OBJECTIVES: To investigate the efficacy of an in-line non-rigid motion-compensated reconstruction (NRC) in an image-navigated high-resolution three-dimensional late gadolinium enhancement (LGE) sequence with Dixon water-fat separation, in a clinical setting. METHODS: Forty-seven consecutive patients were enrolled prospectively and examined with 1.5 T MRI. NRC reconstructions were compared to translational motion-compensated reconstructions (TC) of the same datasets in overall and different sub-category image quality scores, diagnostic confidence, contrast ratios, LGE pattern, and semiautomatic LGE quantification. RESULTS: NRC outperformed TC in all image quality scores (p < 0.001 to 0.016; e.g., overall image quality 5/5 points vs. 4/5). Overall image quality was downgraded in only 23% of NRC datasets vs. 53% of TC datasets due to residual respiratory motion. In both reconstructions, LGE was rated as ischemic in 11 patients and non-ischemic in 10 patients, while it was absent in 26 patients. NRC delivered significantly higher LGE-to-myocardium and blood-to-myocardium contrast ratios (median 6.33 vs. 5.96, p < 0.001 and 4.88 vs. 4.66, p < 0.001, respectively). Automatically detected LGE mass was significantly lower in the NRC reconstruction (p < 0.001). Diagnostic confidence was identical in all cases, with high confidence in 89% and probable in 11% datasets for both reconstructions. No case was rated as inconclusive. CONCLUSIONS: The in-line implementation of a non-rigid motion-compensated reconstruction framework improved image quality in image-navigated free-breathing, isotropic high-resolution 3D LGE imaging with undersampled spiral-like Cartesian sampling and Dixon water-fat separation compared to translational motion correction of the same datasets. The sharper depictions of LGE may lead to more accurate measures of LGE mass. KEY POINTS: • 3D LGE imaging provides high-resolution detection of myocardial scarring. • Non-rigid motion correction provides better image quality in cardiac MRI. • Non-rigid motion correction may lead to more accurate measures of LGE mass.


Assuntos
Meios de Contraste , Gadolínio , Meios de Contraste/farmacologia , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Água
8.
J Cardiovasc Magn Reson ; 24(1): 23, 2022 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-35369885

RESUMO

BACKGROUND: While multiple cardiovascular magnetic resonance (CMR) methods provide excellent reproducibility of global circumferential and global longitudinal strain, achieving highly reproducible segmental strain is more challenging. Previous single-center studies have demonstrated excellent reproducibility of displacement encoding with stimulated echoes (DENSE) segmental circumferential strain. The present study evaluated the reproducibility of DENSE for measurement of whole-slice or global circumferential (Ecc), longitudinal (Ell) and radial (Err) strain, torsion, and segmental Ecc at multiple centers. METHODS: Six centers participated and a total of 81 subjects were studied, including 60 healthy subjects and 21 patients with various types of heart disease. CMR utilized 3 T scanners, and cine DENSE images were acquired in three short-axis planes and in the four-chamber long-axis view. During one imaging session, each subject underwent two separate DENSE scans to assess inter-scan reproducibility. Each subject was taken out of the scanner and repositioned between the scans. Intra-user, inter-user-same-site, inter-user-different-site, and inter-user-Human-Deep-Learning (DL) comparisons assessed the reproducibility of different users analyzing the same data. Inter-scan comparisons assessed the reproducibility of DENSE from scan to scan. The reproducibility of whole-slice or global Ecc, Ell and Err, torsion, and segmental Ecc were quantified using Bland-Altman analysis, the coefficient of variation (CV), and the intraclass correlation coefficient (ICC). CV was considered excellent for CV ≤ 10%, good for 10% < CV ≤ 20%, fair for 20% < CV ≤ 40%, and poor for CV > 40. ICC values were considered excellent for ICC > 0.74, good for ICC 0.6 < ICC ≤ 0.74, fair for ICC 0.4 < ICC ≤ 0.59, poor for ICC < 0.4. RESULTS: Based on CV and ICC, segmental Ecc provided excellent intra-user, inter-user-same-site, inter-user-different-site, inter-user-Human-DL reproducibility and good-excellent inter-scan reproducibility. Whole-slice Ecc and global Ell provided excellent intra-user, inter-user-same-site, inter-user-different-site, inter-user-Human-DL and inter-scan reproducibility. The reproducibility of torsion was good-excellent for all comparisons. For whole-slice Err, CV was in the fair-good range, and ICC was in the good-excellent range. CONCLUSIONS: Multicenter data show that 3 T CMR DENSE provides highly reproducible whole-slice and segmental Ecc, global Ell, and torsion measurements in healthy subjects and heart disease patients.


Assuntos
Cardiopatias , Imagem Cinética por Ressonância Magnética , Voluntários Saudáveis , Cardiopatias/diagnóstico por imagem , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
9.
Magn Reson Med ; 86(1): 277-292, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33619807

RESUMO

PURPOSE: Myofiber strain, Eff , is a mechanistically relevant metric of cardiac cell shortening and is expected to be spatially uniform in healthy populations, making it a prime candidate for the evaluation of local cardiomyocyte contractility. In this study, a new, efficient pipeline was proposed to combine microstructural cDTI and functional DENSE data in order to estimate Eff in vivo. METHODS: Thirty healthy volunteers were scanned with three long-axis (LA) and three short-axis (SA) DENSE slices using 2D displacement encoding and one SA slice of cDTI. The total acquisition time was 11 minutes ± 3 minutes across volunteers. The pipeline first generates 3D SA displacements from all DENSE slices which are then combined with cDTI data to generate a cine of myofiber orientations and compute Eff . The precision of the post-processing pipeline was assessed using a computational phantom study. Transmural myofiber strain was compared to circumferential strain, Ecc , in healthy volunteers using a Wilcoxon sign rank test. RESULTS: In vivo, computed Eff was found uniform transmurally compared to Ecc (-0.14[-0.15, -0.12] vs -0.18 [-0.20, -0.16], P < .001, -0.14 [-0.16, -0.12] vs -0.16 [-0.17, -0.13], P < .001 and -0.14 [-0.16, -0.12] vs Ecc_C = -0.14 [-0.15, -0.11], P = .002, Eff_C vs Ecc_C in the endo, mid, and epi layers, respectively). CONCLUSION: We demonstrate that it is possible to measure in vivo myofiber strain in a healthy human population in 10 minutes per subject. Myofiber strain was observed to be spatially uniform in healthy volunteers making it a potential biomarker for the evaluation of local cardiomyocyte contractility in assessing cardiovascular dysfunction.


Assuntos
Imagem Cinética por Ressonância Magnética , Miócitos Cardíacos , Voluntários Saudáveis , Humanos , Imagens de Fantasmas
10.
Cardiology ; 146(6): 728-736, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34348264

RESUMO

AIMS: Periprocedural myocardial infarctions have been reported in the setting of planned percutaneous coronary intervention (PCI). We assessed the prevalence of nonculprit artery acute myocardial infarction (NCAMI) and its relationship with coronary artery characteristics, final infarct size, and 1-year adverse clinical outcomes in a population of anterior ST-elevated myocardial infarction (STEMI) patients. METHODS AND RESULTS: Late gadolinium-enhanced cardiac magnetic resonance (LGE-CMR) studies were performed within 7 days of admission in 129 anterior STEMI patients from the CIRCUS trial treated by primary PCI. Infarct in the noninfarct artery territory (circumflex, right coronary) was assessed on LGE-CMR and T2-weighted images. Eleven (8.5%) patients exhibited NCAMI. The only independent characteristic significantly associated with NCAMI was the presence of multiple complex coronary lesions (odds ratio = 12.9, 95% confidence interval [3.1-53.4]; p < 0.001). There was a significantly increased infarct size in NCAMI patients compared to patients without NCAMI (45.8 ± 20.4% of the left ventricle [LV] vs. 31.0 ± 15.1% of LV, respectively; p = 0.02), with lower LV ejection fraction (46 ± 10% vs. 34 ± 8%, respectively; p < 0.001). CONCLUSION: NCAMIs are present in 8.5% of anterior STEMI patients and are significantly associated with multiple complex coronary lesions without significant relationship to any revascularization procedural technique. NCAMI was associated with a greater infarct size and reduced LVEF but not worse clinical outcomes at 1 year.


Assuntos
Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Artérias , Humanos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia
11.
Cardiology ; 146(2): 151-160, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33582664

RESUMO

Inflammatory processes have been identified as key mediators of ischemia-reperfusion injury in ST-segment elevation myocardial infarction (STEMI). They add damage to the myocardium and are associated with clinical adverse events (heart failure and cardiovascular death) and poor myocardial recovery. Colchicine is a well-known alkaloid with potent anti-inflammatory properties. In a proof-of-concept phase II trial, colchicine has been associated with a significant 50% reduction of infarct size (assessed by creatine kinase levels) in comparison to placebo in acute STEMI patients referred for primary percutaneous coronary intervention (PPCI). The Colchicine in STEMI Patients Study (COVERT-MI) is an ongoing confirmative prospective, multicenter, randomized, double-blind trial testing whether a short course oral treatment with colchicine versus placebo decreases myocardial injury in patients presenting with STEMI referred for PPCI. Adult patients, with a first STEMI episode and an initial TIMI flow ≤1, referred for PPCI, will be randomized (n = 194) in a 1:1 ratio to receive an oral bolus of colchicine of 2 mg followed by 0.5 mg b.i.d. treatment during 5 days or matching placebo. The primary endpoint will be the reduction in infarct size as assessed by cardiac magnetic resonance at 5 ± 2 days between both groups. The main secondary endpoints will be tested between groups in hierarchical order with left ventricular ejection fraction at 5 days, microvascular obstruction presence at 5 days, and absolute adverse left ventricular remodeling between 5 days and 3 months. This academic study is being financed by a grant from the French Ministry of Health (PHRCN-16-0357). Results from this study will contribute to a better understanding of the complex pathophysiology underlying myocardial injury after STEMI. The present study describes the rationale, design, and methods of the trial.


Assuntos
Infarto do Miocárdio , Intervenção Coronária Percutânea , Adulto , Ensaios Clínicos Fase II como Assunto , Colchicina , Humanos , Imageamento por Ressonância Magnética , Estudos Multicêntricos como Assunto , Infarto do Miocárdio/tratamento farmacológico , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
12.
MAGMA ; 34(3): 437-450, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33048262

RESUMO

OBJECTIVE: In this perfusion magnetic resonance imaging study, the performances of different pseudo-continuous arterial spin labeling (PCASL) sequences were compared: two-dimensional (2D) single-shot readout with simultaneous multislice (SMS), 2D single-shot echo-planar imaging (EPI) and multishot three-dimensional (3D) gradient and spin echo (GRASE) sequences combined with a background-suppression (BS) module. MATERIALS AND METHODS: Whole-brain PCASL images were acquired from seven healthy volunteers. The performance of each protocol was evaluated by extracting regional cerebral blood flow (rCBF) measures using an inline morphometric segmentation prototype. Image data postprocessing and subsequent statistical analyses enabled comparisons at the regional and sub-regional levels. RESULTS: The main findings were as follows: (i) Mean global CBF obtained across methods was were highly correlated, and these correlations were significantly higher among the same readout sequences. (ii) Temporal signal-to-noise ratio and gray-matter-to-white-matter CBF ratio were found to be equivalent for all 2D variants but lower than those of 3D-GRASE. DISCUSSION: Our study demonstrates that the accelerated SMS readout can provide increased acquisition efficiency and/or a higher temporal resolution than conventional 2D and 3D readout sequences. Among all of the methods, 3D-GRASE showed the lowest variability in CBF measurements and thus highest robustness against noise.


Assuntos
Imageamento Tridimensional , Encéfalo , Circulação Cerebrovascular , Imagem Ecoplanar , Humanos , Angiografia por Ressonância Magnética , Marcadores de Spin
13.
Radiology ; 295(3): 542-549, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32208095

RESUMO

Background After acute myocardial infarction (AMI), reperfusion injury is associated with microvascular lesions and myocardial edema. Purpose To evaluate the performance of apparent diffusion coefficient (ADC) quantification compared with T1 and T2 values in the detection of acute myocardial injury. Materials and Methods In this prospective study conducted from June 2016 to November 2018, participants without a history of heart failure or cardiomyopathy were enrolled after undergoing reperfusion for their first AMI. Quantitative T1 and T2 mapping were performed with a 1.5-T MRI scanner and compared with a fast free-breathing acquisition technique for ADC mapping (approximate duration, 3 minutes; five slices; spin-echo cardiac diffusion acquisition; b values, 0 and 200 sec/mm2; six diffusion-encoding directions; five repetitions). Quantitative ADC and unenhanced T1 and T2 values were compared in infarct, border, and remote regions by using Welch analysis of variance with Games-Howell post hoc test for pairwise comparisons. Results Thirty-four participants with AMI underwent MRI an average of 5 days ± 1.9 (standard deviation) after reperfusion. Mean ADC was markedly high in the infarcted regions (2.32 × 10-3 mm2/sec; 95% confidence interval [CI]: 2.28, 2.36) and moderately high in the border regions (1.91 ×10-3 mm2/sec; 95% CI: 1.89, 1.94; P < .001). In remote regions, mean ADC (1.62 ×10-3 mm2/sec; 95% CI: 1.59, 1.64) was comparable to that measured in vivo in healthy volunteers. Within the same regions of interest, although the measures showed similar trends in infarct and remote regions for T1 (mean, 1332 mec [95% CI: 1296, 1368] vs 1045 msec [95% CI: 1034, 1056]; P < .001) and T2 (72 msec [95% CI: 69, 75] vs 50 msec [95% CI: 49, 51]; P < .001), the magnitude of the differences among regions was greater when using ADC. Normalized signal differences between infarct and remote regions showed that diffusion-weighted MRI depicted edema 5.1 (P < .001) and 3.5 (P < .001) times greater than did T1 and T2 maps, respectively. Conclusion Multislice cardiac diffusion-weighted images could be acquired in those with acute myocardial injury. Quantitative apparent diffusion coefficient mapping showed greater differences among remote regions and lesions than did T1 or T2 mapping. © RSNA, 2020 See also the editorial by Lloyd and Farris in this issue.


Assuntos
Edema/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Traumatismo por Reperfusão Miocárdica/diagnóstico por imagem , Idoso , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
15.
J Cardiovasc Magn Reson ; 22(1): 31, 2020 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-32375896

RESUMO

BACKGROUND: The T1 Mapping and Extracellular volume (ECV) Standardization (T1MES) program explored T1 mapping quality assurance using a purpose-developed phantom with Food and Drug Administration (FDA) and Conformité Européenne (CE) regulatory clearance. We report T1 measurement repeatability across centers describing sequence, magnet, and vendor performance. METHODS: Phantoms batch-manufactured in August 2015 underwent 2 years of structural imaging, B0 and B1, and "reference" slow T1 testing. Temperature dependency was evaluated by the United States National Institute of Standards and Technology and by the German Physikalisch-Technische Bundesanstalt. Center-specific T1 mapping repeatability (maximum one scan per week to minimum one per quarter year) was assessed over mean 358 (maximum 1161) days on 34 1.5 T and 22 3 T magnets using multiple T1 mapping sequences. Image and temperature data were analyzed semi-automatically. Repeatability of serial T1 was evaluated in terms of coefficient of variation (CoV), and linear mixed models were constructed to study the interplay of some of the known sources of T1 variation. RESULTS: Over 2 years, phantom gel integrity remained intact (no rips/tears), B0 and B1 homogenous, and "reference" T1 stable compared to baseline (% change at 1.5 T, 1.95 ± 1.39%; 3 T, 2.22 ± 1.44%). Per degrees Celsius, 1.5 T, T1 (MOLLI 5s(3s)3s) increased by 11.4 ms in long native blood tubes and decreased by 1.2 ms in short post-contrast myocardium tubes. Agreement of estimated T1 times with "reference" T1 was similar across Siemens and Philips CMR systems at both field strengths (adjusted R2 ranges for both field strengths, 0.99-1.00). Over 1 year, many 1.5 T and 3 T sequences/magnets were repeatable with mean CoVs < 1 and 2% respectively. Repeatability was narrower for 1.5 T over 3 T. Within T1MES repeatability for native T1 was narrow for several sequences, for example, at 1.5 T, Siemens MOLLI 5s(3s)3s prototype number 448B (mean CoV = 0.27%) and Philips modified Look-Locker inversion recovery (MOLLI) 3s(3s)5s (CoV 0.54%), and at 3 T, Philips MOLLI 3b(3s)5b (CoV 0.33%) and Siemens shortened MOLLI (ShMOLLI) prototype 780C (CoV 0.69%). After adjusting for temperature and field strength, it was found that the T1 mapping sequence and scanner software version (both P < 0.001 at 1.5 T and 3 T), and to a lesser extent the scanner model (P = 0.011, 1.5 T only), had the greatest influence on T1 across multiple centers. CONCLUSION: The T1MES CE/FDA approved phantom is a robust quality assurance device. In a multi-center setting, T1 mapping had performance differences between field strengths, sequences, scanner software versions, and manufacturers. However, several specific combinations of field strength, sequence, and scanner are highly repeatable, and thus, have potential to provide standardized assessment of T1 times for clinical use, although temperature correction is required for native T1 tubes at least.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/normas , Imagens de Fantasmas/normas , Consenso , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
17.
Eur Radiol ; 28(12): 5171-5181, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29948065

RESUMO

OBJECTIVES: The aim of the present study was to evaluate the diagnostic performances of strain and wall thickening analysis in discriminating among three types of myocardium after acute myocardial infarction: non-infarcted myocardium, infarcted myocardium without microvascular obstruction (MVO) and infarcted myocardium with MVO. METHODS: Seventy-one patients with a successfully treated ST-segment elevation myocardial infarction underwent cardiovascular magnetic resonance imaging at 2-6 days after reperfusion. The imaging protocol included conventional cine imaging, myocardial tissue tagging and late gadolinium enhancement. Regional circumferential and radial strain and associated strain rates were analyzed in a 16-segment model as were the absolute and relative wall thickening. RESULTS: Hyperenhancement was detected in 418 (38%) of 1096 segments and was accompanied by MVO in 145 (35%) of hyperenhanced segments. Wall thickening, circumferential and radial strain were all significantly diminished in segments with hyperenhancement and decreased even further if MVO was also present (all p < 0.001). Peak circumferential strain (CS) surpassed all other strain and wall thickening parameters in its ability to discriminate between hyperenhanced and non-enhanced myocardium (all p < 0.05). Furthermore, CS was superior to both absolute and relative wall thickening in differentiating infarcted segments with MVO from infarcted segments without MVO (p = 0.02 and p = 0.001, respectively). CONCLUSIONS: Strain analysis is superior to wall thickening in differentiating between non-infarcted myocardium, infarcted myocardium without MVO and infarcted myocardium with MVO. Peak circumferential strain is the most accurate marker of regional function. KEY POINTS: • CMR can quantify regional myocardial function by analysis of wall thickening on cine images and strain analysis of tissue tagged images. • Strain analysis is superior to wall thickening in differentiating between different degrees of myocardial injury after acute myocardial infarction. • Peak circumferential strain is the most accurate marker of regional function.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Contração Miocárdica/fisiologia , Miocárdio/patologia , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Função Ventricular Esquerda/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Revascularização Miocárdica/métodos , Prognóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia
19.
Eur Radiol ; 27(12): 5158-5168, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28656465

RESUMO

OBJECTIVES: Although myocardial strain analysis is a potential tool to improve patient selection for cardiac resynchronization therapy (CRT), there is currently no validated clinical approach to derive segmental strains. We evaluated the novel segment length in cine (SLICE) technique to derive segmental strains from standard cardiovascular MR (CMR) cine images in CRT candidates. METHODS: Twenty-seven patients with left bundle branch block underwent CMR examination including cine imaging and myocardial tagging (CMR-TAG). SLICE was performed by measuring segment length between anatomical landmarks throughout all phases on short-axis cines. This measure of frame-to-frame segment length change was compared to CMR-TAG circumferential strain measurements. Subsequently, conventional markers of CRT response were calculated. RESULTS: Segmental strains showed good to excellent agreement between SLICE and CMR-TAG (septum strain, intraclass correlation coefficient (ICC) 0.76; lateral wall strain, ICC 0.66). Conventional markers of CRT response also showed close agreement between both methods (ICC 0.61-0.78). Reproducibility of SLICE was excellent for intra-observer testing (all ICC ≥0.76) and good for interobserver testing (all ICC ≥0.61). CONCLUSIONS: The novel SLICE post-processing technique on standard CMR cine images offers both accurate and robust segmental strain measures compared to the 'gold standard' CMR-TAG technique, and has the advantage of being widely available. KEY POINTS: • Myocardial strain analysis could potentially improve patient selection for CRT. • Currently a well validated clinical approach to derive segmental strains is lacking. • The novel SLICE technique derives segmental strains from standard CMR cine images. • SLICE-derived strain markers of CRT response showed close agreement with CMR-TAG. • Future studies will focus on the prognostic value of SLICE in CRT candidates.


Assuntos
Bloqueio de Ramo/diagnóstico por imagem , Terapia de Ressincronização Cardíaca , Imagem Cinética por Ressonância Magnética/métodos , Contração Miocárdica , Função Ventricular Esquerda/fisiologia , Idoso , Biomarcadores , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Prognóstico , Reprodutibilidade dos Testes
20.
Magn Reson Med ; 76(1): 70-82, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26301785

RESUMO

PURPOSE: In this study, we proposed an efficient free-breathing strategy for rapid and improved cardiac diffusion-weighted imaging (DWI) acquisition using a single-shot spin-echo echo planar imaging (SE-EPI) sequence. METHODS: A real-time slice-following technique during free-breathing was combined with a sliding acquisition-window strategy prior Principal Component Analysis temporal Maximum Intensity Projection (PCAtMIP) postprocessing of in-plane co-registered diffusion-weighted images. This methodology was applied to 10 volunteers to quantify the performance of the motion correction technique and the reproducibility of diffusion parameters. RESULTS: The slice-following technique offers a powerful head-foot respiratory motion management solution for SE-EPI cDWI with the advantage of a 100% duty cycle scanning efficiency. The level of co-registration was further improved using nonrigid motion corrections and was evaluated with a co-registration index. Vascular fraction f and the diffusion coefficients D and D* were determined to be 0.122 ± 0.013, 1.41 ± 0.09 × 10(-3) mm(2) /s and 43.6 ± 9.2 × 10(-3) mm(2) /s, respectively. From the multidirectional dataset, the measured mean diffusivity was 1.72 ± 0.09 × 10(-3) mm(2) /s and the fractional anisotropy was 0.36 ± 0.02. CONCLUSION: The slice-following DWI SE-EPI sequence is a promising solution for clinical implementation, offering a robust improved workflow for further evaluation of DWI in cardiology. Magn Reson Med 76:70-82, 2016. © 2015 Wiley Periodicals, Inc.


Assuntos
Algoritmos , Artefatos , Imagem Ecoplanar/métodos , Coração/anatomia & histologia , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Adulto , Sistemas Computacionais , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa