Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38335765

RESUMO

The complex structure of biopharmaceutical products poses an inherent need for their thorough characterization to ensure product quality, safety, and efficacy. Analytical size exclusion chromatography (SEC) is a widely used technique throughout the development and manufacturing of monoclonal antibodies (mAbs) which quantifies product size variants such as aggregates and fragments. Aggregate and fragment content are critical quality attributes (CQAs) in mAb products, as higher contents of such size heterogeneities impact product quality. Historically, SEC methods have achieved sufficient separation between the high molecular weight (HMW) species and the main product. In contrast, some low molecular weight (LMW) species are often not sufficiently different in molecular mass from the main product, making it difficult to achieve appropriate resolutions between the two species. This lack of resolution makes it difficult to consistently quantify the LMW species in mAb-based therapeutics. The following work uses a design of experiments (DoE) approach to establish a robust analytical SEC procedure by evaluating SEC column types and mobile phase compositions using two mAb products with different physiochemical properties. The resulting optimized procedure using a Waters™ BioResolve column exhibits an improved ability to resolve and quantify mAb size variants, highlighting improvement in the resolution of the LMW species. Additionally, the addition of L-arginine as a mobile phase additive showed to reduce secondary interactions and was beneficial in increasing the recoveries of the HMW species.


Assuntos
Anticorpos Monoclonais , Produtos Biológicos , Anticorpos Monoclonais/química , Cromatografia Líquida de Alta Pressão , Cromatografia em Gel , Peso Molecular
2.
J Pharm Biomed Anal ; 249: 116386, 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-39083921

RESUMO

Capillary electrophoresis-sodium dodecyl sulfate (CE-SDS) is a common analytical procedure used to quantitate critical quality attributes relating to the purity and glycosylation of monoclonal antibodies (mAbs). In this study, the application of an Analytical Quality by Design framework incorporating Design of Experiments was used to develop and validate both non-reduced (CE-NR) and reduced (CE-R) versions of this analytical procedure. Formal risk assessments were used to identify critical method attributes for optimization based on their potential impacts to performance criteria outlined in an analytical target profile. The resulting response surfaces connecting these critical factors to method performance were then utilized to generate a harmonized procedure to reduce execution risk across CE-R and CE-NR applications. Validation of these procedures according to regulatory guidelines support that they meet their required performance criteria, and a multivariate assessment of procedure robustness indicates that method parameters are in a sufficient state of control to ensure appropriate quantitation of mAb quality. Overall, this study demonstrates the utility of adopting an Analytical Quality by Design framework to leverage multidimensional knowledge from multiple critical method parameters to ensure an analytical procedure is fit-for-purpose.


Assuntos
Anticorpos Monoclonais , Eletroforese Capilar , Controle de Qualidade , Dodecilsulfato de Sódio , Eletroforese Capilar/métodos , Eletroforese Capilar/normas , Anticorpos Monoclonais/análise , Anticorpos Monoclonais/química , Dodecilsulfato de Sódio/química , Glicosilação , Reprodutibilidade dos Testes , Projetos de Pesquisa
3.
Artigo em Inglês | MEDLINE | ID: mdl-38880058

RESUMO

Protein A (ProA) high-performance liquid chromatography (HPLC) is a common analytical procedure for measuring monoclonal antibody (mAb) titers due to its high specificity and efficiency. Accurate and reliable results of this procedure are imperative, as the quantitation of the total mAb present for in-process samples directly impacts downstream purification steps related to the removal of process-related impurities. This study aimed to improve a platform ProA HPLC analytical procedure which was previously developed using traditional approaches and was not always reliable. By retrospectively applying Analytical Quality by Design (AQbD) principles and statistical assessments of performance, a bias in the calibration standard due to protein-adsorption to common sample vial materials was identified. The inclusion of Tween® 20 into the mobile phase used as sample diluent was optimized to ensure procedure performance and improve analytical range. The resulting procedure robustness was evaluated using Design of Experiment (DoE) approaches and performance was verified against Analytical Target Profile (ATP) criteria as recommended by regulatory agencies. The resulting linearity displayed R2 values of 1.00 with intercept biases of 1.2 % (analyst 1) and 0.8 % (analyst 2), accuracy across all levels was reported at 99.2 % recovery, and intermediate precision was reported as 3.0 % RSD. Application of this new platform procedure has since reduced development timelines for new mAb products by 50 % and allowed for accurate titer determination to support >5 early phase product-specific process decisions without requiring extensive analytical procedure development. This work demonstrates the utility and relative ease of adopting AQbD concepts, even for established procedures, and supporting them with a lifecycle approach to managing procedure performance.


Assuntos
Anticorpos Monoclonais , Cromatografia de Afinidade , Anticorpos Monoclonais/química , Cromatografia de Afinidade/métodos , Cromatografia Líquida de Alta Pressão/métodos , Reprodutibilidade dos Testes , Modelos Lineares , Animais , Proteína Estafilocócica A/química , Cricetulus , Limite de Detecção , Células CHO
4.
J Pharm Biomed Anal ; 246: 116220, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38795426

RESUMO

This work presents the application of AQbD principles to the development of a size exclusion chromatography (SEC) HPLC procedure for the determination of monoclonal antibody (mAb) product purity using state-of-the-art column technology available via the Waters™ XBridge Premier Protein SEC column. Analytical Quality by Design (AQbD) emphasizes a systematic, risk-based lifecycle approach to analytical procedure development based on sound statistical methodologies. It has recently become increasingly recommended by regulatory agencies as a response to the need for greater efficiency, improved reliability, and increased robustness among modern analytical procedures in the pharmaceutical industry. Use of an Analytical Target Profile (ATP) and formal risk assessments informed the application of Design of Experiments (DoE) to optimize this analytical procedure, as well as assess its robustness and ruggedness. Importantly, our ruggedness results demonstrated the transferability of this procedure between two laboratories within the Catalent Biologics Global Network. Application of this analytical procedure as a platform approach for evaluating mAb purity is expected to support expedited, first-in-human timelines of mAb molecules by enabling great quantitative performance with simple mobile phase buffer compositions. Taken together, this case study demonstrates the utility of adopting AQbD principles in analytical procedure development.


Assuntos
Anticorpos Monoclonais , Cromatografia em Gel , Anticorpos Monoclonais/química , Anticorpos Monoclonais/análise , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia em Gel/métodos , Reprodutibilidade dos Testes , Controle de Qualidade , Humanos , Projetos de Pesquisa , Contaminação de Medicamentos/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa