Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Muscle Nerve ; 55(5): 715-726, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27571286

RESUMO

INTRODUCTION: Rotator-cuff injury (RCI) represents 50% of shoulder injuries, and prevalence increases with age. Even with successful tendon repair, muscle and joint function may not return. METHODS: To explore the dysfunction, supraspinatus and ipsilateral deltoid (control) muscles were biopsied during arthroscopic RCI repair for pair-wise histological and protein-expression studies. RESULTS: Supraspinatus showed fiber atrophy (P < 0.0001), fibrosis (by Sirius Red, P = 0.05), reduced vascular density (P < 0.001), and a lower proportion of slow fibers (P < 0.0001) compared with the ipsilateral control muscle. There were also higher levels of atrogin-1 (P = 0.05), vascular endothelial growth factor (VEGF, P < 0.01), and dystrophin (P < 0.008, relative to fiber diameter) versus control. CONCLUSIONS: Adaptive changes in vascular endothelial growth factor and dystrophin were likely associated with reduced vascular supply, fatigue resistance, and fibrosis, accompanied by disuse atrophy from mechanical unloading of supraspinatus after tendon tear. Treatment to promote growth and vascularity in atrophic supraspinatus muscle may help improve functional outcome after surgical repair. Muscle Nerve 55: 715-726, 2017.


Assuntos
Fibras Musculares de Contração Rápida/patologia , Atrofia Muscular/patologia , Lesões do Manguito Rotador/patologia , Idoso , Miosinas Cardíacas/metabolismo , Distrofina/metabolismo , Feminino , Fibrose/diagnóstico por imagem , Fibrose/metabolismo , Fibrose/patologia , Fibrose/fisiopatologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Metaloproteinase 9 da Matriz/metabolismo , Pessoa de Meia-Idade , Fibras Musculares de Contração Rápida/metabolismo , Proteínas Musculares/metabolismo , Atrofia Muscular/diagnóstico por imagem , Atrofia Muscular/metabolismo , Atrofia Muscular/fisiopatologia , Cadeias Pesadas de Miosina/metabolismo , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/metabolismo , Lesões do Manguito Rotador/fisiopatologia , Proteínas Ligases SKP Culina F-Box/metabolismo , Fator A de Crescimento do Endotélio Vascular/metabolismo
2.
Lancet ; 385(9986): 2485-91, 2015 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-25788231

RESUMO

BACKGROUND: Based on the early results of the Placement of Aortic Transcatheter Valves (PARTNER) trial, transcatheter aortic valve replacement (TAVR) is an accepted treatment for patients with severe aortic stenosis who are not suitable for surgery. However, little information is available about the late clinical outcomes in such patients. METHODS: We did this randomised controlled trial at 21 experienced valve centres in Canada, Germany, and the USA. We enrolled patients with severe symptomatic inoperable aortic stenosis and randomly assigned (1:1) them to transfemoral TAVR or to standard treatment, which often included balloon aortic valvuloplasty. Patients and their treating physicians were not masked to treatment allocation. The randomisation was done centrally, and sites learned of the assignment only after a patient had been screened, consented, and entered into the database. The primary outcome of the trial was all-cause mortality at 1 year in the intention-to-treat population, here we present the prespecified findings after 5 years. This study is registered with ClinicalTrials.gov, number NCT00530894. FINDINGS: We screened 3015 patients, of whom 358 were enrolled (mean age 83 years, Society of Thoracic Surgeons Predicted Risk of Mortality 11·7%, 54% female). 179 were assigned to TAVR treatment and 179 were assigned to standard treatment. 20 patients crossed over from the standard treatment group and ten withdrew from study, leaving only six patients at 5 years, of whom five had aortic valve replacement treatment outside of the study. The risk of all-cause mortality at 5 years was 71·8% in the TAVR group versus 93·6% in the standard treatment group (hazard ratio 0·50, 95% CI 0·39-0·65; p<0·0001). At 5 years, 42 (86%) of 49 survivors in the TAVR group had New York Heart Association class 1 or 2 symptoms compared with three (60%) of five in the standard treatment group. Echocardiography after TAVR showed durable haemodynamic benefit (aortic valve area 1·52 cm(2) at 5 years, mean gradient 10·6 mm Hg at 5 years), with no evidence of structural valve deterioration. INTERPRETATION: TAVR is more beneficial than standard treatment for treatment of inoperable aortic stenosis. TAVR should be strongly considered for patients who are not surgical candidates for aortic valve replacement to improve their survival and functional status. Appropriate selection of patients will help to maximise the benefit of TAVR and reduce mortality from severe comorbidities. FUNDING: Edwards Lifesciences.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/fisiopatologia , Canadá , Causas de Morte , Comorbidade , Ecocardiografia , Feminino , Seguimentos , Alemanha , Hemodinâmica , Humanos , Estimativa de Kaplan-Meier , Masculino , Medição de Risco , Acidente Vascular Cerebral/epidemiologia , Taxa de Sobrevida , Resultado do Tratamento , Estados Unidos
3.
Lancet ; 385(9986): 2477-84, 2015 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-25788234

RESUMO

BACKGROUND: The Placement of Aortic Transcatheter Valves (PARTNER) trial showed that mortality at 1 year, 2 years, and 3 years is much the same with transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) for high-risk patients with aortic stenosis. We report here the 5-year outcomes. METHODS: We did this randomised controlled trial at 25 hospitals, in Canada (two), Germany (one), and the USA (23). We used a computer-generated randomisation sequence to randomly assign high-risk patients with severe aortic stenosis to either SAVR or TAVR with a balloon-expandable bovine pericardial tissue valve by either a transfemoral or transapical approach. Patients and their treating physicians were not masked to treatment allocation. The primary outcome of the trial was all-cause mortality in the intention-to-treat population at 1 year, we present here predefined outcomes at 5 years. The study is registered with ClinicalTrials.gov, number NCT00530894. FINDINGS: We screened 3105 patients, of whom 699 were enrolled (348 assigned to TAVR, 351 assigned to SAVR). Overall mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 11·7%. At 5 years, risk of death was 67·8% in the TAVR group compared with 62·4% in the SAVR group (hazard ratio 1·04, 95% CI 0·86-1·24; p=0·76). We recorded no structural valve deterioration requiring surgical valve replacement in either group. Moderate or severe aortic regurgitation occurred in 40 (14%) of 280 patients in the TAVR group and two (1%) of 228 in the SAVR group (p<0·0001), and was associated with increased 5-year risk of mortality in the TAVR group (72·4% for moderate or severe aortic regurgitation vs 56·6% for those with mild aortic regurgitation or less; p=0·003). INTERPRETATION: Our findings show that TAVR as an alternative to surgery for patients with high surgical risk results in similar clinical outcomes. FUNDING: Edwards Lifesciences.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/epidemiologia , Canadá , Causas de Morte , Comorbidade , Feminino , Seguimentos , Alemanha , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Análise de Sobrevida , Taxa de Sobrevida , Resultado do Tratamento , Estados Unidos
4.
Am J Physiol Cell Physiol ; 309(6): C383-91, 2015 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-26135801

RESUMO

The high frequency of poor outcome and chronic pain after surgical repair of shoulder rotator-cuff injury (RCI) prompted this study to explore the potential to amplify muscle regeneration using nitric oxide (NO)-based treatment. After preoperative magnetic resonance imaging (MRI), biopsies of supraspinatus and ipsilateral deltoid (as a control) were collected during reparative surgery for RCI. Muscle fiber diameter, the pattern of neuromuscular junctions observed with alpha-bungarotoxin staining, and the γ:ε subunit ratio of acetylcholine receptors in Western blots were examined in tandem with experiments to determine the in vitro responsiveness of muscle satellite cells to activation (indicated by uptake of bromodeoxyuridine, BrdU) by the NO-donor drug, isosorbide dinitrate (ISDN). Consistent with MRI findings of supraspinatus atrophy (reduced occupation ratio and tangent sign), fiber diameter was lower in supraspinatus than in deltoid. ISDN induced a significant increase over baseline (up to 1.8-fold), in the proportion of BrdU+ (activated) Pax7+ satellite cells in supraspinatus, but not in deltoid, after 40 h in culture. The novel application of denervation indices revealed a trend for supraspinatus muscle to have a higher γ:ε subunit ratio than deltoid (P = 0.13); this ratio inversely with both occupancy ratio (P < 0.05) and the proportion of clusters at neuromuscular junctions (P = 0.05). Results implicate possible supraspinatus denervation in RCI and suggest NO-donor treatment has potential to promote growth in atrophic supraspinatus muscle after RCI and improve functional outcome.


Assuntos
Músculo Deltoide/inervação , Músculo Deltoide/patologia , Fibras Musculares Esqueléticas/patologia , Atrofia Muscular/patologia , Manguito Rotador/inervação , Manguito Rotador/patologia , Células Satélites de Músculo Esquelético/patologia , Idoso , Animais , Músculo Deltoide/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Denervação Muscular , Fibras Musculares Esqueléticas/metabolismo , Junção Neuromuscular/metabolismo , Junção Neuromuscular/patologia , Óxido Nítrico/metabolismo , Regeneração/fisiologia , Células Satélites de Músculo Esquelético/metabolismo , Ombro/inervação , Ombro/patologia
5.
J Card Surg ; 30(6): 510-2, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25873004

RESUMO

A variety of access routes have been employed for transcatheter aortic valve replacement (TAVR). We report a TAVR case using the abdominal aorta as the direct access route when other approaches are not feasible.


Assuntos
Aorta Abdominal , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Humanos , Masculino , Risco , Índice de Gravidade de Doença , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 83(4): 633-41, 2014 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-24123706

RESUMO

OBJECTIVES: To determine the incidence and etiology of thrombocytopenia following transcatheter Aortic valve replacement (TAVR). BACKGROUND: the use of TAVR in the United States has grown rapidly. Anecdotally, thrombocytopenia following TAVR with the Sapien valves has been observed, though little is known about this phenomenon. METHODS: All patients treated with TAVR using a Sapien valve or who underwent isolated balloon aortic valvuloplasty (BAV) at Brigham and Women's Hospital from October 2009 through November 2012 were analyzed. Post-procedure thrombocytopenia severity was stratified as none (>150,000 cells/µL), mild (100-150,000), and moderate to severe (<100,000). Summary statistics and simple comparisons were evaluated. Linear regression models were used to identify patient or procedural factors associated with platelet count nadir. RESULTS: 112 TAVR and 105 BAV patients were analyzed. Following TAVR the prevalence of thrombocytopenia was 69% and the incidence of new thrombocytopenia was 45% compared to 37% and 17% respectively following BAV (P < 0.01). Similar results were found across all strata of thrombocytopenia severity. Post-TAVR platelet nadirs were greater by 1,840 cells/µL for each 1% increase in STS score (P = 0.03) and 670 cells/µL greater for each 1 mmHg increase in pre-TAVR mean aortic stenosis gradient. Among TAVR patients, thrombocytopenia appears to spontaneously resolve an average of 8 days post-procedure. No differences in clinical outcomes based on thrombocytopenia severity were observed except for an increased use of blood products (P = 0.05). CONCLUSIONS: Thrombocytopenia following TAVR with the Edwards' Sapien valves is a frequent but generally self-limited process. The etiology of this phenomenon is unknown.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Trombocitopenia/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Valvuloplastia com Balão , Boston/epidemiologia , Feminino , Humanos , Incidência , Masculino , Contagem de Plaquetas , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Trombocitopenia/sangue , Trombocitopenia/diagnóstico , Fatores de Tempo , Resultado do Tratamento
7.
J Bone Miner Res ; 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38699950

RESUMO

Whether simultaneous automated ascertainments of prevalent vertebral fracture (auto-PVFx) and abdominal aortic calcification (auto-AAC) on vertebral fracture assessment (VFA) lateral spine bone density (BMD) images jointly predict incident fractures in routine clinical practice is unclear. We estimated the independent associations of auto-PVFx and auto-AAC primarily with incident major osteoporotic and secondarily with incident hip and any clinical fractures in 11 013 individuals (mean [SD] age 75.8 [6.8] years, 93.3% female) who had a BMD test combined with VFA between March 2010 and December 2017. Auto-PVFx and auto-AAC were ascertained using convolutional neural networks (CNNs). Proportional hazards models were used to estimate the associations of auto-PVFx and auto-AAC with incident fractures over a mean (SD) follow-up of 3.7 (2.2) years, adjusted for each other and other risk factors. At baseline, 17% (n = 1881) had auto-PVFx and 27% (n = 2974) had a high level of auto-AAC (≥ 6 on scale of 0 to 24). Multivariable-adjusted hazard ratios (HR) for incident major osteoporotic fracture (95% C.I.) were 1.85 (1.59, 2.15) for those with compared to those without auto-PVFx, and 1.36 (1.14, 1.62) for those with high compared to low auto-AAC. The multivariable-adjusted HRs for incident hip fracture were 1.62 (95% C.I. 1.26 to 2.07) for those with compared to those without auto-PVFx, and 1.55 (95% C.I. 1.15 to 2.09) for those high auto-AAC compared to low auto-AAC. The 5-year cumulative incidence of major osteoporotic fracture was 7.1% in those with no auto-PVFx and low auto-AAC, 10.1% in those with no auto-PVFx and high auto-AAC, 13.4% in those with auto-PVFx and low auto-AAC, and 18.0% in those with auto-PVFx and high auto-AAC. While physician manual review of images in clinical practice will still be needed to confirm image quality and provide clinical context for interpretation, simultaneous automated ascertainment of auto-PVFx and auto-AAC can aid fracture risk assessment.


Individuals with calcification of their abdominal aorta (AAC) and vertebral fractures seen on lateral spine bone density images (easily obtained as part of a bone density test) are much more likely to have subsequent fractures. Prior studies have not shown if both AAC and prior vertebral fracture both contribute to fracture prediction in routine clinical practice. Additionally, a barrier to using these images to aid fracture risk assessment at the time of bone density testing has been the need for expert readers to be able to accurately detect both AAC and vertebral fractures. We have developed automated computer methods (using artificial intelligence) to accurately detect vertebral fracture (auto-PVFx) and auto-AAC on lateral spine bone density images for 11 013 older individuals having a bone density test in routine clinical practice. Over a 5-year follow-up period, 7.1% of those with no auto-PVFx and low auto-AAC, 10.1% of those with no auto-PVFx and high auto-AAC, 13.4% of those with auto-PVFx and low auto-AAC, and 18.0% of those with auto-PVFx and high auto-AAC had a major osteoporotic fracture. Auto-PVFx and auto-AAC, ascertained simultaneously on lateral spine bone density images, both contribute to the risk of subsequent major osteoporotic fractures in routine clinical practice settings.

8.
Bone ; 161: 116427, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35489707

RESUMO

BACKGROUND: Convolutional neural networks (CNNs) can identify vertebral compression fractures in GE vertebral fracture assessment (VFA) images with high balanced accuracy, but performance against Hologic VFAs is unknown. To obtain good classification performance, supervised machine learning requires balanced and labeled training data. Active learning is an iterative data annotation process with the ability to reduce the cost of labeling medical image data and reduce class imbalance. PURPOSE: To train CNNs to identify vertebral fractures in Hologic VFAs using an active learning approach, and evaluate the ability of CNNs to generalize to both Hologic and GE VFA images. METHODS: VFAs were obtained from the OsteoLaus Study (labeled Hologic Discovery A, n = 2726), the Manitoba Bone Mineral Density Program (labeled GE Prodigy and iDXA, n = 12,742), and the Canadian Longitudinal Study on Aging (CLSA, unlabeled Hologic Discovery A, n = 17,190). Unlabeled CLSA VFAs were split into five equal-sized partitions (n = 3438) and reviewed sequentially using active learning. Based on predicted fracture probability, 17.6% (n = 3032) of the unlabeled VFAs were selected for expert review using the modified algorithm-based qualitative (mABQ) method. CNNs were simultaneously trained on Hologic, GE dual-energy and GE single-energy VFAs. Two ensemble CNNs were constructed using the maximum and mean predicted probability from six separately trained CNNs that differed due to stochastic variation. CNNs were evaluated against the OsteoLaus validation set (n = 408) during the active learning process; ensemble performance was measured against the OsteoLaus test set (n = 819). RESULTS: The baseline CNN, prior to active learning, achieved 55.0% sensitivity, 97.9% specificity, 57.9% positive predictive value (PPV), F1-score 56.4%. Through active learning, 2942 CLSA Hologic VFAs (492 fractures) were added to the training data-increasing the proportion of Hologic VFAs with fractures from 4.2% to 12.5%. With active learning, CNN performance improved to 80.0% sensitivity, 99.7% specificity, 94.1% PPV, F1-score 86.5%. The CNN maximum ensemble achieved 91.9% sensitivity (100% for grade 3 and 95.5% for grade 2 fractures), 99.0% specificity, 81.0% PPV, F1-score 86.1%. CONCLUSION: Simultaneously training on a composite dataset consisting of both Hologic and GE VFAs allowed for the development of a single manufacturer-independent CNN that generalized to both scanner types with good classification performance. Active learning can reduce class imbalance and produce an effective medical image classifier while only labeling a subset of available unlabeled image data-thereby reducing the time and cost required to train a machine learning model.


Assuntos
Fraturas por Compressão , Fraturas da Coluna Vertebral , Canadá , Fraturas por Compressão/diagnóstico por imagem , Humanos , Estudos Longitudinais , Redes Neurais de Computação , Fraturas da Coluna Vertebral/diagnóstico por imagem
10.
Lancet ; 374(9689): 565-76, 2009 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-19683642

RESUMO

Over 4 million people worldwide have received a prosthetic heart valve, and an estimated 300,000 valves are being implanted every year. Prosthetic heart valves improve quality of life and survival of patients with severe valvular heart disease, but the need for antithrombotic therapy to prevent thrombotic complications in valve recipients poses challenges for clinicians and patients. Here, we review antithrombotic therapies for patients with prosthetic heart valves and management of thromboembolic complications. Advances in antithrombotic therapy and valve technologies are likely to improve the management of patients with prosthetic heart valves in developed countries, but the most important unmet need and potential for benefit from these new therapies is in developing countries where a massive and rapidly increasing burden of valvular heart disease exists.


Assuntos
Medicina Baseada em Evidências/organização & administração , Fibrinolíticos/uso terapêutico , Próteses Valvulares Cardíacas/efeitos adversos , Tromboembolia , Algoritmos , Bioprótese/efeitos adversos , Efeitos Psicossociais da Doença , Países Desenvolvidos , Países em Desenvolvimento , Fibrinolíticos/efeitos adversos , Previsões , Saúde Global , Necessidades e Demandas de Serviços de Saúde , Doenças das Valvas Cardíacas/epidemiologia , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas/classificação , Próteses Valvulares Cardíacas/tendências , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Humanos , Procedimentos Cirúrgicos Bucais , Guias de Prática Clínica como Assunto , Pré-Medicação , Desenho de Prótese , Falha de Prótese , Fatores de Risco , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Resultado do Tratamento
12.
Emerg Med J ; 27(12): 958-9, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21036798

RESUMO

Hypothermic cardiac arrest is a relatively uncommon presentation to United States Emergency Departments. During 1979-2002, the Centers for Disease Control reported that an average of 689 deaths per year in the US were attributed to exposure to excessive natural cold. Severe hypothermia (<30°C) confers marked depression of critical metabolic and biochemical functions, but may also provide protection to the brain and other organs while resuscitation is undertaken. For all hypothermic patients, measures designed to prevent further heat loss and begin rewarming should be instituted, but should not delay routine Advanced Cardiac and Trauma Life Support procedures. Rewarming methods include passive rewarming (insulation, removal from environment), active external rewarming (heating blankets, radiant heat, warm water immersion), and active core rewarming (warm inhalation, warmed intravenous fluids, gastrointestinal irrigation, bladder irrigation, dialysis, thoracostomy lavage, and cardiopulmonary bypass).


Assuntos
Ponte Cardiopulmonar , Descompressão Cirúrgica , Parada Cardíaca/etiologia , Parada Cardíaca/terapia , Hipotermia/complicações , Laparotomia , Adulto , Humanos , Hipotermia/terapia , Masculino
15.
Cardiovasc Pathol ; 15(3): 123-9, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16697924

RESUMO

Balloon valvuloplasty has been in clinical use for over 20 years, but the prospect of repairing and replacing cardiac valves via catheter-based techniques represents a truly recent development. This review introduces evolving technologies and their relevance to cardiovascular pathologists.


Assuntos
Bioprótese , Cateterismo , Doenças das Valvas Cardíacas/terapia , Próteses Valvulares Cardíacas , Valva Aórtica , Estenose da Valva Aórtica/terapia , Cateterismo/instrumentação , Cateterismo/métodos , Doenças das Valvas Cardíacas/cirurgia , Humanos , Valva Mitral , Insuficiência da Valva Mitral/terapia , Estenose da Valva Mitral/terapia , Valva Pulmonar , Stents , Valva Tricúspide
17.
Ann Thorac Surg ; 101(4): 1587-9, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27000584
18.
Ann Thorac Surg ; 101(1): 344-6, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26694273

RESUMO

With the development of the transcatheter aortic valve replacement, innovative approaches can be geared to atypical and challenging cases. We describe a case of transcatheter aortic valve replacement via a left anterior thoracotomy in a patient with pectus excavatum and unusual intrathoracic anatomy where surgical and traditional transcatheter aortic valve replacement approaches were deemed inapplicable.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese , Tórax em Funil/cirurgia , Toracoplastia/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Angiografia , Estenose da Valva Aórtica/complicações , Tórax em Funil/complicações , Tórax em Funil/diagnóstico , Humanos , Masculino , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X
19.
Am J Cardiol ; 117(10): 1643-1650, 2016 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-27036077

RESUMO

It is unclear if surgical exposure confers a risk advantage compared with a percutaneous approach for patients undergoing endovascular procedures requiring large-bore femoral artery access. From the randomized controlled Placement of Aortic Transcatheter Valve trials A and B and the continued access registries, a total of 1,416 patients received transfemoral transcatheter aortic valve replacement, of which 857 underwent surgical, and 559 underwent percutaneous access. Thirty-day rates of major vascular complications and quality of life scores were assessed. Propensity matching was used to adjust for unmeasured confounders. Overall, there were 116 major vascular complications (8.2%). Complication rates decreased dramatically during the study period. In unadjusted analysis, major vascular complications were significantly less common in the percutaneous access group (35 [6.3%] vs 81 [9.5%] p = 0.032). However, among 292 propensity-matched pairs, there was no difference in major vascular complications (22 [7.5%] vs 28 [9.6%], p = 0.37). Percutaneous access was associated with fewer total in-hospital vascular complications (46 [16%] vs 66 [23%], p = 0.036), shorter median procedural duration (97 interquartile range [IQR 68 to 166] vs 121 [IQR 78 to 194] minutes, p <0.0001), and median length of stay (4 [IQR 2 to 8] vs 6 [IQR 3 to 10] days, p <0.0001). There were no significant differences in quality of life scores at 30 days. Surgical access for large-bore femoral access does not appear to confer any advantages over percutaneous access and may be associated with more minor vascular complications.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/mortalidade , Artéria Femoral , Seguimentos , Humanos , Incidência , Qualidade de Vida , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
20.
J Biomed Mater Res B Appl Biomater ; 103(8): 1709-15, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25545639

RESUMO

We sought to evaluate the principles of disruptive innovation, defined as technology innovation that fundamentally shifts performance and utility metrics, as applied to transcatheter aortic valve implantation (TAVI). In particular, we considered implantation procedure, device design, cost, and patient population. Generally cheaper and lower performing, classical disruptive innovations are first commercialized in insignificant markets, promise lower margins, and often parasitize existing usage, representing unattractive investments for established market participants. However, despite presently high unit cost, TAVI is less invasive, treats a "new," generally high risk, patient population, and is generally done by a multidisciplinary integrated heart team. Moreover, at least in the short-term TAVI has not been lower-performing than open surgical aortic valve replacement in high-risk patients. We conclude that TAVI extends the paradigm of disruptive innovation and represents an attractive commercial opportunity space. Moreover, should the long-term performance and durability of TAVI approach that of conventional prostheses, TAVI will be an increasingly attractive commercial opportunity.


Assuntos
Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Animais , Humanos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa