Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Drug Investig ; 44(7): 541-548, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38886336

RESUMO

BACKGROUND: CAVE is a single arm, Phase 2 trial, that demonstrated anti-tumor activity of cetuximab rechallenge plus avelumab in patients with RAS wild type (wt) metastatic colorectal cancer (mCRC). OBJECTIVE: We conducted a post hoc analysis to identify potential radiomic biomarkers for patients with CRC liver metastasis (LM). PATIENTS AND METHODS: Patients with LM that could be measured by enhanced contrast phase computed tomography (CT) imaging at baseline and at first response evaluation were included. Multiple texture parameters were extracted with the LifeX Software. Delta-texture (D-TA) variations were calculated by comparing data at baseline and after treatment. RESULTS: Overall, 55/77 patients (71%) had LM; 39 met the inclusion criteria for the current analysis. The D-TA parameters that significantly correlated at univariate analysis with median progression-free survival (mPFS) were EntropyHistogram (p = 0.021), HomogeneityGLCM (p < 0.001) and Dissimilarity GLCM (p = 0.002). At multivariate analysis, only HomogeneityGLCM resulted significant for PFS (p = 0.001). Patients (19/39, 48.7%) with reduction of HomogeneityGLCM experienced better mPFS (4.6 vs 2.9 months; HR 0.45; 95% CI 0.23-0.88; p = 0.021) and median overall survival (mOS) (17.3 vs 6.8 months; HR 0.40, 95% CI 0.21-0.80; p = 0.010). A trend to better mPFS, was also observed in patients with RAS/BRAF wt circulating tumor DNA and reduction of HomogeneityGLCM. Overall survival was significantly better in this subgroup of patients with low HomogeneityGLCM: mOS was 17.8 (95% CI 15.5-20.2) versus 6.8 months (95% CI 3.6-10.0) (HR 0.34, 95% CI 0.14-0.81; p = 0.016). CONCLUSION: Reduction in the D-TA parameter HomogeneityGLCM by radiomic analysis correlates with improved outcomes in patients with LM receiving cetuximab rechallenge plus avelumab therapy. Larger prospective studies are needed to validate and confirm these findings.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/patologia , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/diagnóstico por imagem , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Tomografia Computadorizada por Raios X/métodos , Adulto , Cetuximab/administração & dosagem , Cetuximab/uso terapêutico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Protocolos de Quimioterapia Combinada Antineoplásica/administração & dosagem , Intervalo Livre de Progressão , Idoso de 80 Anos ou mais , Radiômica
2.
J Pers Med ; 13(12)2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38138910

RESUMO

Purpose: The purpose of this meta-analysis is to investigate the effectiveness of supplementing screening mammography with three-dimensional automated breast ultrasonography (3D ABUS) in improving breast cancer detection rates in asymptomatic women with dense breasts. Materials and Methods: We conducted a thorough review of scientific publications comparing 3D ABUS and mammography. Articles for inclusion were sourced from peer-reviewed journal databases, namely MEDLINE (PubMed) and Scopus, based on an initial screening of their titles and abstracts. To ensure a sufficient sample size for meaningful analysis, only studies evaluating a minimum of 20 patients were retained. Eligibility for evaluation was further limited to articles written in English. Additionally, selected studies were required to have participants aged 18 or above at the time of the study. We analyzed 25 studies published between 2000 and 2021, which included a total of 31,549 women with dense breasts. Among these women, 229 underwent mammography alone, while 347 underwent mammography in combination with 3D ABUS. The average age of the women was 50.86 years (±10 years standard deviation), with a range of 40-56 years. In our efforts to address and reduce bias, we applied a range of statistical analyses. These included assessing study variation through heterogeneity assessment, accounting for potential study variability using a random-effects model, exploring sources of bias via meta-regression analysis, and checking for publication bias through funnel plots and the Egger test. These methods ensured the reliability of our study findings. Results: According to the 25 studies included in this metanalysis, out of the total number of women, 27,495 were diagnosed with breast cancer. Of these, 211 were diagnosed through mammography alone, while an additional 329 women were diagnosed through the combination of full-field digital mammography (FFDSM) and 3D ABUS. This represents an increase of 51.5%. The rate of cancers detected per 1000 women screened was 23.25‱ (95% confidence interval [CI]: 21.20, 25.60; p < 0.001) with mammography alone. In contrast, the addition of 3D ABUS to mammography increased the number of tumors detected to 20.95‱ (95% confidence interval [CI]: 18.50, 23; p < 0.001) per 1000 women screened. Discussion: Even though variability in study results, lack of long-term outcomes, and selection bias may be present, this systematic review and meta-analysis confirms that supplementing mammography with 3D ABUS increases the accuracy of breast cancer detection in women with ACR3 to ACR4 breasts. Our findings suggest that the combination of mammography and 3D ABUS should be considered for screening women with dense breasts. Conclusions: Our research confirms that adding 3D automated breast ultrasound to mammography-only screening in patients with dense breasts (ACR3 and ACR4) significantly (p < 0.05) increases the cancer detection rate.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa