1.
J Prosthet Dent ; 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39242275

RESUMO

STATEMENT OF PROBLEM: Though computer-aided design and computer-aided manufactured (CAD-CAM) denture bases have become popular, evidence on the ability of C. albicans cells to adhere to these denture bases is lacking. PURPOSE: The purpose of this in vitro study was to evaluate the adherence of Candida albicans to differently manufactured acrylic resin denture bases. MATERIAL AND METHODS: Acrylic resin disks were fabricated using a total of 6 different fabrication methods (compression molding, injection molding, CAD-CAM milling, and rapid prototyping on 3 different printers with 3 different resins). Each material was evaluated for adherence of C. albicans using 2 different experimental methods - suspension in inoculated tryptic soy broth (TSB) or placed onto a uniform lawn of C. albicans on tryptone soya agar (TSA) with 5% sheep's blood. Attached cells were quantified by spiral plating and then used to re-inoculate sterile plates. Logarithmic transformation was completed to normalize data. For the broth suspension, the Kruskal-Wallis test was used to identify any differences between the 6 specimen types in terms of recovery, and the Dunn test was used for post hoc analysis. For the microbial lawn experiment, 1-way analysis of variance (ANOVA) and then the Tukey Honestly Significant Difference (HSD) post hoc test were used. RESULTS: Statistically significant differences were found between the numbers of adherent cells based on manufacturing method and between experimental designs (P<.05). All resins demonstrated growth with re-inoculation. CONCLUSIONS: Though statistical significance was noted, neither experimental technique demonstrated what is likely a clinically significant preferential binding to any particular resin surface. Attached Candida cells are effective carriers of pathogens to uninfected surfaces. Further studies are indicated for potential virulence factors and differences in printed resins.

2.
J Prosthet Dent ; 2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37105823

RESUMO

STATEMENT OF PROBLEM: Research on implementation factors for digitally fabricated complete dentures is sparse. PURPOSE: The purpose of this survey of prosthodontists was to explore the current usage of conventionally and digitally fabricated complete dentures and to identify factors that may impact their use. MATERIAL AND METHODS: A confidential cross-sectional survey consisting of 20 questions was conducted in 2019 using the Qualtrics Research Suite. The survey was distributed via electronic mail to all 1820 members of the American College of Prosthodontics. Frequency distributions, chi-squared tests, and Fisher exact tests were used to analyze the data and compare subgroups (α=.05). RESULTS: The response rate was 16.8% (N=305). A total of 31.5% of respondents were implementing digitally fabricated complete dentures, 36.6% were interested in learning and/or incorporating them, 37.7% reported that they had not tried them, and 12.7% had tried them but were not interested in using them again. When asked which factors were important when considering the implementation of digitally fabricated complete dentures, 55.8% indicated laboratory costs, 72.1% total chair time spent, and 81.9% patient satisfaction. Prosthodontists who graduated from dental school after about 1991 were more interested in learning about and incorporating digitally fabricated complete dentures than earlier graduates (P=.02). CONCLUSIONS: The survey results indicate that prosthodontists are implementing digitally fabricated complete dentures in clinical practice but not at the rate that might be expected of a technology that has been available for nearly a decade. Factors reported to matter in the decision to implement this technology were decreased time, overall cost, and improved patient satisfaction.

3.
J Esthet Restor Dent ; 34(3): 519-526, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35019205

RESUMO

OBJECTIVE: The purpose of this study was to compare the linear and volumetric wear of conventional and milled double-cross-linked polymethyl methacrylate, nano-composite, and nano-ceramic infused resin posterior denture teeth. METHODS: Double-cross-linked polymethyl methacrylate (PMMA) premolar teeth were scanned and used to mill denture teeth from a double-cross-linked PMMA resin disc and a nano-composite with nano-ceramic infused resin disc. The specimens (n = 8: conventional double-cross-linked PMMA resin teeth-DCL, milled double-cross-linked PMMA resin teeth-DCL-CAM, conventional nano-composite infused resin teeth with four layers composed of composite and PMMA resin teeth-NC, and milled nano-composite and nano-ceramic infused resin teeth-NC-CAM) underwent chewing simulation in the biaxial fatigue testing machine at 1.53 Hz frequency, thermocycling between 5 and 55°C, and 49 N force against a Ø6mm steatite. After 250,000 cycles, the linear changes on the occlusal surfaces of the specimens were analyzed with pairwise comparison with Bonferroni post hoc test, and the volumetric changes of the specimens were analyzed with a one-way ANOVA with Bonferroni post hoc test (p < 0.05). RESULTS: The linear wear of the conventional and milled denture teeth was linearly correlated with the number of cycles between 50,000 and 250,000 cycles. After 250,000 cycles, NC had significantly more linear and volumetric wear (0.52 ± 0.10 mm and 4.29 ± 0.94 mm3 ) than DCL (0.18 ± 0.03 mm and 0.74 ± 0.14 mm3 ; p < 0.001) and NC-CAM (0.15 ± 0.03 mm and 0.35 ± 0.21 mm3 ; p < 0.001). DCL-CAM and NC-CAM had linearly and volumetrically equivalent wear to DCL (p > 0.05). NC-CAM had significantly less linear and volumetric wear (0.15 ± 0.03 mm and 0.35 ± 0.21 mm3 ) than DCL-CAM (0.24 ± 0.07 mm and 1.22 ± 0.61 mm3 ; p < 0.05). CONCLUSIONS: The conventional NC wore more than DCL, DCL-CAM, and NC-CAM. Both milled denture teeth wore an equivalent amount to conventional DCL. The wear between the conventional and milled DCL was equivalent. CLINICAL SIGNIFICANCE: Denture teeth selection can prolong the retreading process and decrease the occurrences of prosthetic complications. Milled denture teeth are good alternatives to conventional denture teeth with regards to their wear resistance.


Assuntos
Desgaste de Restauração Dentária , Polimetil Metacrilato , Resinas Compostas , Desenho Assistido por Computador , Dentaduras , Teste de Materiais , Propriedades de Superfície
4.
J Prosthodont ; 30(1): 47-50, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33058337

RESUMO

PURPOSE: The purpose of this retrospective, cross-sectional study is to evaluate if there is a difference in number of visits (including fabrication and postoperative) and remake rate when comparing conventionally fabricated and digitally fabricated complete dentures by dental students in a predoctoral student dental clinic. MATERIALS AND METHODS: This two-year retrospective cross-sectional study consisted of a chart review for patients receiving maxillary and/or mandibular complete dentures between 2017 and 2019 (n = 314) at the UNC Adams School of Dentistry predoctoral student clinic. No control group was determined for this study. Data were extracted for 242 conventional dentures and 39 digital dentures. Objective treatment outcomes were obtained for each included denture: the number of patient appointments from preliminary impressions to denture placement, the number of postoperative visits, any complications noted, and any need for remakes. Fisher's Exact Test and Cochran-Mantel-Haenszel analysis were completed with statistical significance set at p < 0.05. RESULTS: For the number of visits from preliminary impression to placement, 50% of conventionally fabricated dentures had 6 or more visits, while only 5% of digitally fabricated dentures had 6 or more visits. This difference for the number of patient visits was statistically significant (p < 0.05). Additionally, conventionally fabricated dentures required an average of 2-3 postoperative visits, whereas digitally fabricated dentures required 1-2 postoperative visits. This difference was also statistically significant (p < 0.05). For the number of dentures requiring remake, there was no statistical difference (p = 0.1904). CONCLUSIONS: When comparing conventionally fabricated and digitally fabricated dentures in the predoctoral clinic, the digitally fabricated dentures required fewer patient appointments from start to finish, and fewer postoperative appointments than conventionally fabricated dentures. Fewer visits may be an important consideration for patients, especially those with limited access to care.


Assuntos
Clínicas Odontológicas , Universidades , Desenho Assistido por Computador , Estudos Transversais , Prótese Total , Humanos , Estudos Retrospectivos
5.
J Prosthodont ; 30(3): 264-270, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33179810

RESUMO

PURPOSE:  The purpose of this survey was to assess dental laboratory technicians' perceptions of the quality of communication and techniques used when receiving removable prosthodontic cases. Additionally, responses were compared to a 2009 survey and changes in trends were evaluated. MATERIALS AND METHODS:    An eleven-question anonymous response survey was developed based on a 2009 survey that assessed dental laboratory technicians' perceptions.  The survey was distributed via Qualtrics to members of the National Association of Dental Laboratories (NADL) The survey included questions related to detail of instruction, quality of work received, design of the prosthesis, and type of articulator used.  Responses were compared to those received in 2009. RESULTS:  Fifty-two survey responses were received from dental laboratory technicians. Of these, 12 did not provide removable prosthodontics services and were excluded. The remaining 40 responses were analyzed. Of these, only 3.7% of the responding laboratory technicians reported receiving work authorizations from dentists that were complete enough to do their best work. While roughly half of the respondents (48.49%) expected a dentist to send a design for a cast partial denture framework, most respondents (72.5%) answered that they designed the majority of the partial denture frameworks they fabricated. The majority of respondents reported that complete denture impressions were not border molded in custom trays, and that most dentists did not rearrange or modify a wax setup for complete or partial dentures. These findings were consistent with the trends reported in the 2009 survey. CONCLUSIONS:  Most dental laboratory technicians answered that based on their selected techniques, dentists tend to complete clinical procedures that minimize patient chair time. While the surveyed technicians appeared satisfied with the quality of work they received, there was a consistent message that communication was frequently inadequate, limiting the technicians ability to fabricate their best work.


Assuntos
Prótese Parcial Removível , Prostodontia , Técnicos em Prótese Dentária , Humanos , Laboratórios , Laboratórios Odontológicos , Inquéritos e Questionários
6.
J Prosthet Dent ; 122(3): 301-308.e1, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30948296

RESUMO

STATEMENT OF PROBLEM: Implant therapy involving an unsplinted 2-implant-retained overdenture is well defined as a successful treatment for a patient with an edentulous mandible. However, a similar unsplinted implant therapy supporting a maxillary overdenture is not well characterized. PURPOSE: The purpose of this retrospective study was to evaluate maxillary overdentures retained by 4 unsplinted implants measuring implant survival, overdenture survival, and patient-reported outcomes. MATERIAL AND METHODS: Participants who had received an unsplinted implant-retained maxillary overdenture were included in the study. Participants presented for one denture recall appointment, during which comprehensive examination, including radiographs, was performed and clinical findings were recorded. Participants also completed the Oral Health Impact Profile-49 (OHIP-49) and a 20-item visual analog scale (VAS) satisfaction questionnaire. Nonparametric statistical tests were used to compare OHIP-49 and VAS scores across age, sex, time since overdenture insertion, mandibular dental status, smoking status, maxillary mucosal health, and overdenture hygiene. RESULTS: For the 44 participants, 3 of 4 implants failed in 1 individual. The cumulative implant survival rate was 98% (97.7% patient level). No prosthetic failures (that is, overdenture replacement) occurred, indicating a 100% prosthesis survival rate. The mean ±standard deviation OHIP-49 severity score was 23.6 ±26.0, and the mean ±standard deviation total VAS score was 179.2 ±29.4. Increased age was associated with lower OHIP-49 severity score (P=.036), and participants with unhealthy oral mucosa or denture stomatitis demonstrated significantly higher OHIP-49 severity scores (P=.003). CONCLUSIONS: In this retrospective evaluation, unsplinted implant-retained maxillary overdenture therapy was associated with high implant and prosthetic survival, as well as high patient satisfaction and quality of life. Age, sex, maxillary mucosal health, and mandibular dental status resulted in significant differences with respect to oral health-related quality of life and patient satisfaction, indicating that this treatment option may be ideal for certain patients.


Assuntos
Implantes Dentários , Revestimento de Dentadura , Estudos de Coortes , Prótese Dentária Fixada por Implante , Retenção de Dentadura , Humanos , Satisfação do Paciente , Qualidade de Vida , Estudos Retrospectivos , Resultado do Tratamento
7.
J Prosthodont ; 26(1): 5-18, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27598416

RESUMO

PURPOSE: A systematic search of the literature was performed to identify and characterize articles reporting the influence of removable partial denture (RPD) therapy on satisfaction and quality of life (QoL). MATERIALS AND METHODS: The literature search for relevant articles published between January 1983 and March 30, 2013 was conducted using keyword searches of electronic databases and complimentary hand searches. The search strategy included the following keyword combinations (MeSH and free-text terms): fail, complication, surviv*, longevity, outcome, patient satisfaction or QoL, and denture or prosthes*, and partial and removable. Based on inclusion and exclusion criteria, articles focused on the effect of RPD therapy were reviewed and classified according to Strength-of-Recommendation Taxonomy (SORT) criteria. RESULTS: The combined search identified 997 publications; 198 duplicates were identified and removed, leaving 799 references for further evaluation. After abstract review, 209 articles were selected and read; 18 reports representing findings from 4002 patients were included. While two studies were prospective comparative investigations, the majority of studies represented cross-sectional and retrospective studies. Different instruments were used to measure oral health-quality of life (OHQoL) and satisfaction. Several investigations reported a significant association of satisfaction and QoL with either (a) age of the patient, (b) number of occluding dental units replaced, (c) replacement of anterior teeth, and (d) nature of the opposing arch. CONCLUSIONS: A paucity of detailed investigations concerning outcomes of RPD therapy was noted. Improvement in OHQoL or satisfaction following provision of RPDs was not consistently reported. There is little evidence supporting any association between patient-reported QoL or satisfaction with technical or biological parameters of therapy. Therapeutic success of tooth replacement using RPDs should be carefully considered and compared with alternatives.


Assuntos
Prótese Parcial Removível , Satisfação do Paciente , Qualidade de Vida , Humanos
8.
Clin Oral Implants Res ; 25(2): 207-13, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23278481

RESUMO

PURPOSE: Removable partial dentures (RPDs) represent standard treatment for partial edentulism despite major shortcomings. To alleviate these shortcomings, endosseous implants provide support and stability as well as contribute to maintenance of alveolar bone. This prospective, within subject, time series study evaluated patient-based outcomes of RPDs compared to implant-supported removable partial dentures (ISRPDs). The study hypothesis was that the ISRPD would substantially improve oral health quality of life for patients. MATERIALS AND METHODS: Seventeen patients requesting new mandibular Kennedy I or II RPDs received one 6-mm dental implant in one or both of the posterior edentulous areas. After healing, conventional RPDs were fabricated and delivered. Twelve weeks later, second-stage surgery was performed, and ball abutments with Clix attachments were inserted, thereby converting the prostheses to ISRPDs. Oral health quality of life was evaluated using the 49-item Oral Health Impact Profile (OHIP-49) questionnaire. The OHIP-49 was administered prior to treatment (baseline), at 6 and 12 weeks following RPD delivery and at 6 and 12 weeks following ISRPD conversion. Radiographic evaluation was performed at 6 and 12 weeks following ISRPD conversion. In statistical analysis, a fixed-slope random intercept variance components model took account of the multiple observations per person over time. RESULTS: In 17 subjects, 29 of 30 implants survived. The failed implant was replaced without complications. Abutment complications were limited to one abutment loosening and one attachment replacement. Minor prosthodontic complications were recorded. The OHIP-49 score reduced by 11.8 points, on average, at 12 weeks following ISRPD conversion (P = 0.011). CONCLUSIONS: Patients reported improved oral health following conversion to an ISRPD from RPD. The ISRPD involving short implants is one treatment option that should be considered when treatment planning Kennedy Class I and II patients.


Assuntos
Prótese Dentária Fixada por Implante , Prótese Parcial Removível , Saúde Bucal , Qualidade de Vida , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Falha de Restauração Dentária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
9.
J Oral Sci ; 64(2): 178-180, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35321965

RESUMO

The purpose of this study is to assess students' perception of digital waxing software for dental anatomy education. Dental students were introduced to digital waxing during a dental anatomy course, and were requested to finish a voluntary survey. Students strongly agreed (18.2%) or agreed (48.0%) with the statement "digital waxing contributed to my learning of dental anatomy", and strongly agreed (29.9%) and agreed (55.8%) with the statement "The digital waxing software helped develop my wax-up skills". The digital waxing software may be effective for dental anatomy education, but students do not believe digital waxing can be a replacement for conventional wax-up practice.


Assuntos
Educação em Odontologia , Software , Humanos , Aprendizagem , Percepção , Estudantes
10.
Int J Oral Maxillofac Implants ; 36(5): 966-976, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34698723

RESUMO

PURPOSE: To evaluate the clinical, radiographic, and prosthetic outcomes of a single custom CAD/CAM abutment system on implants from four manufacturers, with a mean clinical service of 4 years in a retrospective, multicenter case series study. MATERIALS AND METHODS: Adult subjects (n = 142) previously restored with titanium or gold-shaded titanium nitride custom CAD/CAM abutments (Atlantis, Dentsply Sirona; n = 259) connected to implants from four different manufacturers (Dentsply Sirona Implants [AT], Biomet 3i [BM], Nobel Biocare [NB], Straumann [ST]), irrespective of implant-abutment interface, and replacing one or more teeth in any position were recalled for a single-visit examination by calibrated investigators at six university clinics. The primary outcomes evaluated included abutment success and survival; secondary outcomes included assessment of papillae fill, probing pocket depth (PD), bleeding on probing (BOP), marginal bone levels (MBLs), and patient-reported outcome measures (PROMs). RESULTS: Two-hundred fifty-five (98.5%) abutments supported cement-retained restorations, and four (1.5%) abutments supported screw-retained restorations. Forty-two patients had 64 AT implants (25%), 31 patients had 61 BM implants (24%), 26 patients had 50 NB implants (19%), and 43 patients had 84 ST implants (32%). The overall implant-CAD/CAM abutment success rate was 92.66% (95% CI: 88.78%, 95.53%) for all implants examined, and the survival rate was 98.84% (95% CI: 96.65%, 99.76%) for all implants evaluated. The Jemt papillae index demonstrated a minimum of at least 50% to complete fill of the interproximal papillae in 65.0% of sites. PDs had a median value of 3.0 mm, and BOP was present on 19% of abutment surfaces. Mean MBL changes from the time of placement to exam were -0.24 ± 0.99 mm (-4.9 to 2.3; P = .058) for mesial sites and -0.32 ± 0.96 mm (-4.9 to 2.1; P = .000) for distal sites. PROMs expressed 93% of patients reporting good to very good masticatory function, 97% of patients reporting being satisfied or very satisfied with their esthetic outcomes, and 94% of patients indicating that they were satisfied or very satisfied with their overall implant-restorative outcomes. CONCLUSION: This retrospective, multicenter clinical study of FDA 510k-approved titanium CAD/CAM abutments of a single manufacturer on multiple implant systems demonstrated high levels of success and survival as well as stable peri-implant tissue outcomes, reflected by overwhelmingly positive PROMs.


Assuntos
Projeto do Implante Dentário-Pivô , Implantes Dentários , Adulto , Estudos Transversais , Dente Suporte , Estética Dentária , Seguimentos , Humanos , Estudos Retrospectivos , Titânio , Zircônio
11.
Int J Periodontics Restorative Dent ; 40(3): 383­392, 2020 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-32130284

RESUMO

Immediate implant placement in extraction sockets requires management of postextraction alveolar resorption. This randomized controlled trial evaluated the facial alveolar bone dimension 10 months following immediate implant placement with or without the addition of anorganic xenograft at the time of flapless, one-stage placement of a sloped-platform implant. The primary outcome of facial crestal alveolar bone thickness revealed no difference in the mean dimension (no graft: 1.47 ± 0.85 mm; graft: 1.63 ± 0.71 mm; P = .950). Secondary outcomes, including pink esthetic score, were not different between the two groups. This study suggests that bone formation does occur along the facial surface of implants placed into extraction sockets.

12.
Dent Clin North Am ; 63(2): 199-216, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30825986

RESUMO

The essential promise of implant dentistry is the ability to imperceptibly replace missing teeth. To achieve this, careful planning, execution, and maintenance is required by the dentist and patient to maintain a long-term esthetic and functional result. Unfortunately, as a result of biological, prosthetic, and iatrogenic factors, unesthetic results can occur. This article explores the potential causes for the unesthetic dental implant and the possible solutions that may improve the clinical situation. Whereas relatively simple errors may be corrected through prosthetic means, greater complications may require surgical intervention to achieve the desired result.


Assuntos
Implantes Dentários , Perda de Dente , Implantação Dentária Endóssea , Estética Dentária , Humanos , Planejamento de Assistência ao Paciente , Prostodontia
13.
Dent Clin North Am ; 63(2): 217-231, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30825987

RESUMO

Dental implants continue to grow in popularity because they are a predictable treatment to replace missing teeth. They have a high success rate; however, they are still associated with some clinical complications. This article discusses a diverse range of complications related to the restorative and mechanical aspects of dental implants and the management of such complications, as well as potential factors contributing to them.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Humanos
14.
Int J Oral Maxillofac Implants ; 34(2): 499­505, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30703184

RESUMO

PURPOSE: The peri-implant bone and mucosa architecture contribute to the health and esthetics of single-tooth dental implants. The implant-tooth distance (ITD) has been regarded as a key determinant of their outcomes. This study was conducted to determine the relationship between ITD and peri-implant bone, mucosa, and pink esthetic scores (PES) for anterior single-tooth implants. MATERIALS AND METHODS: For 44 dental implants with a microthread conical abutment interface design placed in 38 participants, periapical radiographs and photographs were evaluated at 1 and 4 years to assess interproximal bone levels and PES. RESULTS: Mean mesial and distal marginal bone level change over 4 years was 0.20 ± 1.00 mm and 0.20 ± 0.74 mm, respectively. In this cohort there was no relationship between ITD and interproximal bone changes or papilla fill at 4 years; however, marginal bone changes influenced PES score-the smaller the ITD, the lower the PES (P < .001). Alone, ITD did not influence marginal bone levels or papilla in this cohort. CONCLUSION: These results imply a complex relationship between ITD, marginal bone levels, and PES scores for single-tooth implants.


Assuntos
Perda do Osso Alveolar/patologia , Implantação Dentária Endóssea/métodos , Implantes Dentários para Um Único Dente , Adulto , Estudos de Coortes , Estética Dentária , Feminino , Gengiva/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Mucosa Bucal/patologia , Análise de Regressão
15.
Int J Oral Maxillofac Implants ; 33(4): 895-904, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30025007

RESUMO

PURPOSE: To compare, by gene profiling analysis, the molecular events underscoring peri-implant mucosa formation at machined vs laser-microgrooved implant healing abutments. MATERIALS AND METHODS: Forty endosseous implants were placed by a one-stage approach in 20 healthy subjects in nonadjacent sites for single-tooth restorations. In a split-mouth design, machined smooth and laser-microgrooved healing abutments were randomly assigned in each subject. Peri-implant mucosa adjacent to healing abutments was harvested by tissue punch biopsy at either 1, 2, 4, or 8 weeks following abutment placement. Total RNA was isolated from the peri-implant transmucosal soft tissues. A whole genome microarray using the Affymetrix Human Gene 2.1 ST Array was performed to describe gene expression profiles in relation to abutment topography and healing time duration. Data analysis was completed using GeneSpring software v.12.6. RESULTS: Differential gene expression was revealed at all time points and among surfaces. Five hundred one genes were differentially expressed (fold change ≥ 2.0) at machined versus laser-modified abutments, and 459 of these were statistically significant (P ≤ .05). At 1 week, unique expression of IL-24 and MMP1 was observed in tissues from laser-treated surfaces. At 2, 4, and 8 weeks, mRNAs encoding keratins and protective proteins of cornified epithelium were upregulated in tissues from laser-modified abutments. At 4 weeks, upregulation (> 2-fold) of mRNAs encoding proteins associated with collagen fibril formation and function was observed in tissue from laser-modified abutments. In both tissues of machined and laser-modified abutments, mRNAs encoding junctional epithelium-specific proteins, ostogenic ameloblast associated protein (ODAM) and follicular dendritic cell secreted protein (FDCSP) were highly upregulated throughout weeks 2 to 8. CONCLUSION: Peri-implant abutment mucosal wound healing involves selective differentiation of epithelium and induction of the junctional epithelium. Laser-mediated alterations in abutment topography enhance collagen fibril-associated gene expression and alter epithelium/junctional epithelial gene expression. Clinically, shallower probing depths are measured at laser-mediated versus machined implant abutments.


Assuntos
Dente Suporte , Implantação Dentária Endóssea , Implantes Dentários , Expressão Gênica/fisiologia , Mucosa Bucal/fisiologia , Cicatrização/genética , Adulto , Idoso , Inserção Epitelial/metabolismo , Feminino , Perfilação da Expressão Gênica , Humanos , Interleucinas/genética , Queratinas/genética , Masculino , Metaloproteinase 1 da Matriz/genética , Pessoa de Meia-Idade , Absorção pela Mucosa Oral , Osseointegração/fisiologia , RNA Mensageiro/genética , Propriedades de Superfície , Titânio , Adulto Jovem
16.
Biomaterials ; 28(36): 5418-25, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17868850

RESUMO

It is widely accepted that implant surface factors affect the quality of the bone-to-implant interface. Recent additional treatments superimposed on moderately rough cpTitanium surface provide further enhancement of bone-to-implant contact. The aim of this study was to compare osteoinductive and bone-specific gene expression in cells adherent to titanium dioxide-grit blasted (TiO2) versus TiO2 grit blasted and HF treated (TiO2/HF) cpTitanium implant surfaces. MC3T3-E1 cells were grown in osteogenic supplements on the titanium disk surfaces for 1-14 days. Real-time PCR was used to measure RUNX-2, Osterix, and bone sialoprotein (BSP) mRNA levels. Implants were placed in rat tibia and, following harvesting at 1-7 days after placement, real-time PCR was used to measure RUNX-2, alkaline phosphatase (ALP), and BSP mRNA levels in implant adherent cells. In cell culture, RUNX-2 and Osterix levels were significantly increased (p<0.05) on the TiO2/HF surfaces as compared to the TiO2 and smooth surfaces through the cultural period, while BSP expression was elevated on both TiO2 and TiO2/HF surfaces when compared to a machined surface control. In cells adherent to implants retrieved from rat tibia, RUNX-2 mRNA levels were 2-fold and 8-fold greater on the TiO2/HF surfaces at 1-3 and 7 days following implantation. This was paralleled by significantly greater levels of ALP at 3 and 7 days and BSP mRNA at 7 days following implantation. As a marker of osteoinduction, the increased levels of RUNX-2 in cells adherent to the TiO2/HF surfaces suggest that the additional HF treatment of the TiO2 grit blasted surface results in surface properties that support adherent cell osteoinduction. In vivo assessments of implant adherent cell phenotypes provide further insight into the mechanisms affecting alloplast-tissue interactions.


Assuntos
Regulação da Expressão Gênica/efeitos dos fármacos , Ácido Fluorídrico/química , Osteoblastos/efeitos dos fármacos , Osteoblastos/metabolismo , Titânio/química , Titânio/farmacologia , Animais , Adesão Celular/efeitos dos fármacos , Linhagem Celular , Camundongos , Microscopia Eletrônica de Varredura , RNA Mensageiro/genética , Ratos , Propriedades de Superfície
17.
Compend Contin Educ Dent ; 28(4): 216-25; quiz 226, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17487047

RESUMO

The aim of this article is to identify current opportunities for the immediate loading of endosseous dental implants. A biologic basis for the clinical parameters associated with success and failure of immediately loaded implants is presented, and select clinical situations where immediate loading is presently advocated will be illustrated. The wide-ranging applications of the immediate-loading concept for endosseous dental implants will be introduced; however, further experimental validation is necessary before incorporating all of these various expedited therapeutic approaches into practice.


Assuntos
Dente Suporte , Implantação Dentária Endóssea/métodos , Implantes Dentários , Reabsorção Óssea/fisiopatologia , Humanos , Osseointegração/fisiologia , Osteogênese/fisiologia , Fatores de Tempo , Resultado do Tratamento
18.
J Dent Educ ; 81(4): 387-394, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28365602

RESUMO

This study compared the acceptability and relative effectiveness of case-based learning (CBL) versus traditional lecture-based (LB) instruction in a preclinical removable prosthodontics course in the University of North Carolina at Chapel Hill School of Dentistry DDS curriculum. The entire second-year class (N=82) comprised this crossover study's sample. Assessments of baseline comprehension and confidence in removable partial denture (RPD) treatment planning were conducted at the beginning of the course. Near the end of the course, half of the class received CBL and LB instruction in an RPD module in alternating sequence, with students serving as their own control group. Assessments of perceived RPD treatment planning efficacy, comprehension, and instruction method preference were administered directly after students completed the RPD module and six months later. Analyses of variance accounting for period, carryover, and sequence effects were used to determine the relative effects of each approach using a p<0.05 statistical significance threshold. The results showed that the students preferred CBL (81%) over LB instruction (9%), a pattern that remained unchanged after a six-month period. Despite notable period and carryover effects, CBL was also associated with higher gains in RPD treatment planning comprehension (p=0.04) and perceived efficacy (p=0.01) compared to LB instruction. These gains diminished six months after the course-a finding based on a 49% follow-up response rate. Overall, the students overwhelmingly preferred CBL to LB instruction, and the findings suggest small albeit measurable educational benefits associated with CBL. This study's findings support the introduction and further testing of CBL in the preclinical dental curriculum, in anticipation of possible future benefits evident during clinical training.


Assuntos
Prostodontia/educação , Ensino , Prótese Parcial Removível , Avaliação Educacional , Humanos , Aprendizagem Baseada em Problemas
19.
Int J Oral Maxillofac Implants ; 21(3): 405-12, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16796283

RESUMO

PURPOSE: The aim of this retrospective study was to examine the peri-implant tissue status at immediately provisionalized anterior maxillary implants 12 to 30 months following tooth replacement. MATERIALS AND METHODS: This is a retrospective study of 43 microthreaded, TiO2 grit-blasted implants placed in healed ridges and immediate extraction sockets to restore maxillary anterior and premolar teeth in 28 patients. The cortical bone position relative to the implant reference point was evaluated at implant placement and 6 to 30 months following restoration. Radiographs were assessed using 7x magnification. The distance from the reference point to the cortical bone was measured to +/- 0.1 mm. The relationship of the peri-implant mucosa to the incisal edge of the definitive prosthesis was recorded. RESULTS: Four implants in 3 individuals failed during the first 6 weeks following placement and provisional loading. Cortical bone adaptation from the time of implant placement up to 30 months following restoration ranged from 0.0 mm to 1.5 mm (average, 0.33 +/- 0.40 mm mesially and 0.28 +/- 0.37 mm distally). The mean radiographic measurements from the interproximal crestal bone to the contact point were 4.53 +/- -0.91 mm (mesial) and 4.06 +/- 0.98. Maintenance and growth of papilla was observed in this group of immediate provisionalized single-tooth implants. Definitive abutment or abutment screw loosening was not observed. DISCUSSION: The linear clinical and radiographic measures of peri-implant tissue responses suggest that proper implant placement is followed by supracrestal biological width formation along the abutment and preservation of toothlike tissue contours. This may influence buccal peri-implant tissue dimensions. CONCLUSIONS: Generalized maintenance of crestal bone and the increased soft tissue dimension with maintenance of peri-implant papilla were identified as expected outcomes for immediate loading/provisionalization of microthreaded, TiO2 grit-blasted implants. Control of peri-implant tissues can be achieved to provide predictable and esthetic treatment for anterior tooth replacement using dental implants.


Assuntos
Processo Alveolar/anatomia & histologia , Implantação Dentária Endóssea/métodos , Implantes Dentários para Um Único Dente , Mucosa Bucal/anatomia & histologia , Adolescente , Adulto , Processo Alveolar/diagnóstico por imagem , Humanos , Radiografia , Estudos Retrospectivos , Propriedades de Superfície , Fatores de Tempo , Resultado do Tratamento
20.
Artigo em Inglês | MEDLINE | ID: mdl-27560668

RESUMO

A central dental implant success criterion is the marginal bone response as measured longitudinally. Factors that influence marginal bone changes include osseous and soft tissue architecture, occlusal loading factors, implant position, implant design, and inflammatory processes. The evolution of implant design is multifactorial and includes the implant-abutment interface geometries. The primary objective of this study was to compare the proximal marginal bone changes following placement and loading of internal conus design implants (ICI) and external hex design implants (EXI) used in the treatment of posterior partial edentulism. Among 45 enrolled participants, 39 were treated with 47 ICI or 46 EXI implants using a one-stage implant protocol. Prosthetic restoration was completed after 12 weeks using stock titanium abutments and all-ceramic crowns. Follow-up visits including clinical and radiographic examinations were performed 6 months after permanent restoration and then annually for 3 years. Marginal bone level changes, papilla index scores, condition of the peri-implant mucosa, presence of complications, and participant satisfaction were evaluated. The mean marginal bone level change from implant placement to 3 years was -0.25 ± 0.60 mm and -0.5 ± 0.93 mm for ICI and EXI implants, respectively. The change recorded from permanent restoration to 3 years was a gain of 0.31 ± 0.41 mm versus 0.04 ± 0.51 mm for ICI and EXI implants, respectively (P < .05). In the evaluation of interproximal soft tissue 3 years after permanent restoration, 80% of mandibular and 66% of maxillary interproximal ICI sites received papilla scores of 2 and 3, compared with 50% of mandibular and 60% of maxillary interproximal EXI sites. No significant differences in plaque or bleeding scores were recorded. Abutment/healing abutment complications were recorded for 11 EXI versus 1 ICI participant. The vast majority (> 90%) of participants stated they were satisfied or very satisfied with their implant prosthesis and rated function and esthetics highly for both implant types after 3 years in function. Modestly greater marginal bone loss occurred at EXI implants. Further, more positive papilla scores were found between adjacent ICI implants than between adjacent EXI implants. EXI implants displayed more abutment complications than the ICI implants. The implant-abutment interface design may contribute to therapeutic outcome differences. Replacement of missing posterior teeth with unsplinted implants was successful at the implant level and as reported by the participant.


Assuntos
Implantes Dentários , Planejamento de Prótese Dentária , Adolescente , Adulto , Idoso , Perda do Osso Alveolar/etiologia , Cerâmica , Coroas , Adaptação Marginal Dentária , Prótese Dentária Fixada por Implante , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Prospectivos , Titânio , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS