Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 102(7): 1376-1385, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37727885

RESUMO

OBJECTIVES: The aim of the current study was to analyze the clinical and procedural predictors of thrombocytopenia and the relationship between the decrease in platelet count (DPC) and change in vWF function (ΔvWF) after transcatheter aortic valve replacement (TAVR). BACKGROUND: TAVR often causes temporary thrombocytopenia. At the same time, TAVR leads to a restoration of von Willebrand factor (vWF) function. METHODS: One hundred and forty-one patients with severe aortic stenosis undergoing TAVR were included in the study. Platelet count and vWF function (vWF:Ac/Ag ratio) were assessed at baseline and 6 h after TAVR. Thrombocytopenia was defined as platelet count <150/nL. RESULTS: Median platelet count at baseline was 214/nL (interquartile range [IQR]: 176-261) and decreased significantly to 184/nL (IQR: 145-222) 6 h after TAVR. The number of patients with thrombocytopenia increased from 12.8% at baseline to 29.1% after 6 h. DPC 6 h after TAVR showed a significant correlation with ΔvWF (r = - 0.254, p = 0.002). Patients with DPC > 20% had significantly higher ΔvWF (10.9% vs. 6.5%, p = 0.021). Obese patients showed a significantly lower DPC (11.8% vs. 19.9%, p = 0.001). In multivariate analysis, ΔvWF 6 h after TAVR was the only significant predictor for DPC > 20% (p = 0.017). CONCLUSIONS: The restoration of vWF after TAVR is a significant predictor for DPC after TAVR. An increased platelet consumption due to vWF restoration could play a key role in the development of thrombocytopenia after TAVR.


Assuntos
Estenose da Valva Aórtica , Trombocitopenia , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fator de von Willebrand , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Fatores de Risco , Trombocitopenia/diagnóstico , Trombocitopenia/etiologia
2.
Thorac Cardiovasc Surg ; 71(2): 84-93, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-34176110

RESUMO

BACKGROUND: The MANTA vascular closure device (VCD) is a novel collagen plug-based VCD for large bore arteriotomies. The current literature regarding complication rates of this device is quite variable and mostly limited to relatively small case series. METHODS: This study is retrospective analysis of the MANTA VCD-related main access site complications according to Valve Academic Research Consortium-2 (VARC-2) criteria during the hospital stay. Particular attention was paid to the detailed analysis of multislice computed tomography with regard to the anatomy of the access vessel and the puncture site itself. RESULTS: A total of 524 patients underwent transfemoral transcatheter aortic valve implantation (TF TAVI) including the use of the MANTA device (18F) for percutaneous vascular closure. A group of 22 patients was excluded from the study due to incomplete imaging data. During the study period, we observed 28 major (5.6%) and five minor (1.0%) MANTA device-related vascular complications. There was no patient death related to these adverse events. Female gender, vessel angulation at the puncture site, and at least moderate calcification of the dorsal vessel segment were identified as independent predictors for major complications. CONCLUSIONS: The MANTA device is a feasible option for vascular closure of large bore arteriotomies in patients undergoing TF TAVI or other percutaneous transfemoral interventions. Furthermore, we have identified novel predictors for device failure/complications that should be taken into account for selection of the appropriate closure device. To our knowledge, this report is one of the largest case series analyzing the use of the MANTA VCD.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Humanos , Feminino , Dispositivos de Oclusão Vascular/efeitos adversos , Técnicas Hemostáticas/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia
3.
Aging Clin Exp Res ; 35(9): 1865-1872, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37392348

RESUMO

BACKGROUND: Postoperative delirium (POD) is a serious complication following anaesthesia and surgery and significantly influences postoperative outcome especially in the elderly population. Intraoperative music and positive suggestions influence postoperative outcomes by attenuating analgesic demand and increasing patient satisfaction. AIMS: Here, we examined the effect of intraoperative music and positive suggestions on the development of POD in aged patients undergoing transcatheter aortic valve replacement (TAVR) procedure under general anaesthesia. METHODS: For this randomized placebo-controlled study, eligible patients without cognitive deficit, indicated by a MMSE < 10 points, were anesthetized using remifentanil and sevoflurane. Anaesthetic depth was guide with bispectral index. An audiotape with positive suggestions was applied from a MP3 player via headphones. POD, pain and PONV was assessed. CAM-ICU and Nu-DESC were done twice daily for the first 5 days. RESULTS: Of 140 patients 118 patients could be analysed (57 male, 80.6 ± 5.1 years). POD was diagnosed in 16 patients (12.7%). POD was significantly more often observed in male (12, 21.1%) than in female (4, 6.6%, p = 0.02) and in patients with a low MMSE (23.6 ± 4.5 vs. 26.8 ± 2.8, p = 0.001). Anaesthetic depth did not influence the incidence of POD. Intraoperative music and suggestions did not affect the rate of POD, pain, analgesic requirement or PONV. DISCUSSION: In patients undergoing TAVR male sex and low MMSE scoring are associated with an increase in POD. CONCLUSIONS: Intraoperative music and positive suggestions do not influence the incidence of POD in this patient group. STUDY REGISTRATION: DRKS: 00024444, start of registration: 4.02.202, final registration: 17.09.2021.


Assuntos
Anestésicos , Delírio , Delírio do Despertar , Humanos , Masculino , Idoso , Feminino , Delírio do Despertar/prevenção & controle , Delírio/etiologia , Delírio/prevenção & controle , Delírio/epidemiologia , Náusea e Vômito Pós-Operatórios/complicações , Dor , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia
4.
Catheter Cardiovasc Interv ; 99(4): 1259-1267, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35084083

RESUMO

BACKGROUND: Transcatheter mitral valve repair is an increasingly used therapy for mitral regurgitation which requires fluoroscopic guidance. Limiting radiation exposure during lengthy procedures is important for both patient and operator safety. This study aimed to investigate radiation dose during contemporary use of MitraClip implantation and the effects of a dose reduction program. METHODS: A total of 115 patients who underwent MitraClip implantation were prospectively enrolled in a single-center observational study. During the inclusion period, our institution adopted a radiation dose reduction program, comprising lowering of fluoroscopy pulse rate and image target dose. The first 58 patients were treated with conventional fluoroscopy settings, while the following 57 patients underwent the procedure with the newly implemented low dose protocol. RESULTS: Radiation dose area product significantly decreased after introduction of the low dose protocol (693 [366-1231] vs. 2265 [1517-3914] cGy·cm2 , p < 0.001). After correcting for fluoroscopy time, gender and body mass index, the low dose protocol emerged as a strong negative predictor of radiation dose (p < 0.001), reducing dose area product by 64% (95% confidence interval [57-70]). Device time, device success, and procedural safety did not differ between the normal dose and low dose group. Furthermore, the low dose protocol was not associated with an increased incidence of a combined endpoint consisting of death, repeat intervention, or heart surgery during 12 months follow-up. CONCLUSION: Reduction of radiation exposure during transcatheter mitral valve repair by 64% is feasible without affecting procedural success or safety.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Exposição à Radiação , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 92(1): 149-156, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29130616

RESUMO

BACKGROUND: Although the incidence of periprocedural complications has decreased in transcatheter aortic valve implantation (TAVI), life-threatening complications occur and emergency veno-arterial extracorporeal membrane oxygenation (vaECMO) can provide immediate circulatory stabilization. We report our two-center experience of vaECMO during life-threatening complications in TAVI. METHODS: From January 2010 to December 2015, 1,810 consecutive patients underwent TAVI at two centers. Clinical characteristics, type of complication, outcome and temporal trends in the requirement of emergency vaECMO were evaluated. RESULTS: Life-threatening complications requiring vaECMO occurred in 1.8% of cases (33 patients; 22 transfemoral, 11 transapical). Indications for vaECMO were ventricular rupture (30%, 10/33), low output (15%, 5/33), bleeding (12%, 4/33), coronary artery impairment (9%, 3/33), ventricular arrhythmias (6%, 2/33), severe aortic regurgitation (6%, 2/33), aortic annular rupture (6%, 2/33), and aortic dissection (3%, 1/33). In 4 cases, no definite cause for hemodynamic instability was identified. Conversion to open heart surgery was necessary in 42% of patients (14/33). Percutaneous coronary intervention was performed in all cases with coronary artery impairment (9%, 3/33). Patients with severe aortic regurgitation (6%, 2/33) underwent emergency valve-in-valve implantation. Other patients received, in addition to vaECMO support conservative treatment (42%, 14/33). In-hospital mortality and 30-day mortality were 46% (15/33). Of patients discharged, 67% (12/18) had no neurological impairment, whereas mild and severe neurological impairment was found in 11% (2/18) and 22% (4/18), respectively. From 2010 to 2015, with increasing procedures (from n = 43 to n = 553) requirement of vaECMO decreased from 9.3% to 0.9% (P for the trend <0.001). CONCLUSION: Over a 6-year period, need for emergency vaECMO during TAVI significantly decreased over time. Despite high in-hospital mortality, vaECMO represents a feasible strategy for hemodynamic support in case of life-threatening complications.


Assuntos
Valva Aórtica/cirurgia , Oxigenação por Membrana Extracorpórea , Doenças das Valvas Cardíacas/cirurgia , Complicações Pós-Operatórias/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Emergências , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/mortalidade , Feminino , Alemanha , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Mortalidade Hospitalar , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/mortalidade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
6.
Sleep Breath ; 22(3): 703-711, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29327119

RESUMO

BACKGROUND: Increased epicardial fat volume (EFV) is a common feature of patients with sleep-disordered breathing (SDB), is considered as an established marker of cardiovascular risk, and is associated with adverse cardiovascular events after myocardial infarction (MI). METHODS: To investigate the association between different measures of SDB severity and EFV after acute MI, we enrolled 105 patients with acute MI in this study. Unattended in-hospital polysomnography was performed to determine the number of apneas and hypopneas per hour during sleep (apnea-hypopnea index, AHI). To determine nocturnal hypoxemic burden, we used pulse oximetry and applied a novel parameter, the hypoxia load representing the integrated area of desaturation divided by total sleep time (HLTST). Of 105 patients, 56 underwent cardiovascular magnetic resonance to define EFV. RESULTS: HLTST was significantly associated with EFV (r2 = 0.316, p = 0.025). Multivariate linear regression analysis accounting for age, sex, body mass index, smoking, and left ventricular mass demonstrated that the HLTST was an independent modulator of EFV (B-coefficient 0.435 (95% CI 0.021-0.591); p = 0.015). In contrast, AHI or established measures of hypoxemia did not correlate with EFV. CONCLUSIONS: HLTST, a novel parameter to determine nocturnal hypoxemic burden, and not AHI as an event-based measure of SDB, was associated with EFV in patients with acute MI. Further studies are warranted to confirm the link between nocturnal hypoxemia and EFV and to determine the prognostic value of a more detailed characterization of nocturnal hypoxemic burden in patients with high cardiovascular risk.


Assuntos
Tecido Adiposo , Hipóxia/complicações , Infarto do Miocárdio/complicações , Pericárdio , Feminino , Humanos , Hipóxia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Polissonografia , Estudos Prospectivos
7.
J Interv Cardiol ; 29(5): 461-468, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27477024

RESUMO

BACKGROUND: The paclitaxel drug coated balloon (DCB) is an established treatment for bare metal stent (BMS) in-stent restenosis (ISR) in native coronary arteries. The evidence of DCB-application for drug eluting stent (DES) ISR both in native coronaries and saphenous vein grafts (SVG) is limited. Aim of our study was to compare the differential efficacy of DCB for treatment of BMS- and DES-ISR in native coronary vessels and SVGs. METHODS AND RESULTS: N = 135 DCB-treated patients with available follow up (FU) angiography were included in this retrospective study. Patients received treatment between April 2009 and March 2013 at 2 tertiary care hospitals in Germany. DCB was applied in BMS-ISR (n = 65; 48%) and DES-ISR (n = 70; 52%). DCB-treated lesions were located in native coronary arteries (n = 110; 81%; BMS-ISR: n = 58; 53%; DES-ISR: n = 52; 47%) and SVGs (n = 25; 19%; BMS-ISR: n = 7, 28%; DES-ISR: n = 18, 72%). Median FU was 12 months. Endpoints were binary restenosis and target lesion revascularization (TLR). Binary restenosis (29% vs. 57%; P < 0.01) and TLR (18% vs. 46%; P < 0.01) were significantly more frequent in DES-ISR versus BMS-ISR. In SVGs, TLR was required in 72% (DES-ISR) versus 14% (BMS-ISR); P = 0.02. In the Kaplan-Meier-analysis freedom from both endpoints was significantly decreased in the DES-lesions both in the total population (binary restenosis P < 0.01; TLR P < 0.01) and native coronaries (binary restenosis P = 0.02; TLR P = 0.04). CONCLUSIONS: DCB treatment is less effective in DES-ISR than in BMS-ISR. The diminished efficacy of DCB treatment is even more pronounced in DES-ISR located within degenerated SVGs.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Reestenose Coronária , Stents Farmacológicos/efeitos adversos , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/métodos , Antineoplásicos Fitogênicos/uso terapêutico , Angiografia Coronária/métodos , Reestenose Coronária/diagnóstico , Reestenose Coronária/etiologia , Reestenose Coronária/prevenção & controle , Reestenose Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Feminino , Alemanha , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Paclitaxel/uso terapêutico , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Veia Safena/patologia , Veia Safena/transplante , Fatores de Tempo
8.
Eur Respir J ; 45(3): 680-90, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25359347

RESUMO

Structural and functional integrity of the right heart is important in the prognosis after acute myocardial infarction (AMI). The objective of this study was to assess the impact of sleep disordered breathing (SDB) on structure and function of the right heart early after AMI. 54 patients underwent cardiovascular magnetic resonance 3-5 days and 12 weeks after AMI, and were stratified according to the presence of SDB, defined as an apnoea-hypopnoea index of ≥ 15 events · h(-1). 12 weeks after AMI, end-diastolic volume of the right ventricle had increased significantly in patients with SDB (n=27) versus those without (n=25) (mean ± sd 14 ± 23% versus 0 ± 17%, p=0.020). Multivariable linear regression analysis accounting for age, sex, body mass index, smoking, left ventricular mass and left ventricular end-systolic volume showed that the apnoea-hypopnoea index was significantly associated with right ventricular end-diastolic volume (B-coefficient 0.315 (95% CI 0.013-0.617); p=0.041). From baseline to 12 weeks, right atrial diastolic area increased more in patients with SDB (2.9 ± 3.7 cm(2) versus 1.0 ± 2.4 cm(2), p=0.038; when adjusted for left ventricular end systolic volume, p=0.166). SDB diagnosed shortly after AMI predicts an increase of right ventricular end-diastolic volume and possibly right atrial area within the following 12 weeks. Thus, SDB may contribute to enlargement of the right heart after AMI.


Assuntos
Hipertrofia Ventricular Direita , Infarto do Miocárdio/complicações , Síndromes da Apneia do Sono , Ecocardiografia/métodos , Feminino , Alemanha , Humanos , Hipertrofia Ventricular Direita/diagnóstico , Hipertrofia Ventricular Direita/etiologia , Hipertrofia Ventricular Direita/patologia , Hipertrofia Ventricular Direita/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Polissonografia/métodos , Prognóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/diagnóstico
9.
Europace ; 17(9): 1376-82, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25759410

RESUMO

AIMS: The isolation of the pulmonary veins (PVs) is the mainstay of atrial fibrillation (AF) ablation, which with current ablation techniques can be achieved in almost all cases. Reconnection of PVs constitutes the most frequent cause of AF recurrence. Visually guided laser balloon ablation (VGLA) is a novel system with very high rate of persistence of pulmonary vein isolation (PVI) three months after the first procedure shown in preclinical and clinical studies. We aimed to determine the acute efficiency of the laser energy during PVI with the help of adenosine provocation. METHODS AND RESULTS: Twenty-six patients (19 male; mean age 64 ± 9 years) with symptomatic paroxysmal AF were included in the study. Pulmonary vein isolation was performed using the VGLA system. After successful PVI, we studied the effects of intravenous adenosine (18 mg) on activation of each PV at least 20 min after PVI. A total of 104 PVs were targeted. The balloon catheter could not be placed in two PVs. Of the remaining 102 PVs 99 (97% of the ablated PVs) could be successfully isolated. Adenosine was administered for each isolated PV in 25 patients. Only six PVs (6.7%) in five patients (20%) showed a PV reconnection during adenosine provocation. CONCLUSION: Pulmonary vein isolation with VGLA is a feasible technique for PVI with a very effective acute lesion formation. The clinical significance of this low reconnection rate has to be determined.


Assuntos
Adenosina/administração & dosagem , Antiarrítmicos/administração & dosagem , Fibrilação Atrial/tratamento farmacológico , Terapia a Laser/efeitos adversos , Complicações Pós-Operatórias , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
10.
BMC Med Imaging ; 15: 34, 2015 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-26306577

RESUMO

BACKGROUND: Aortic valve area (AVA) estimation in patients with aortic stenosis may be obtained using several methods. This study was undertaken to verify the cardiovascular magnetic resonance (CMR) planimetry of aortic stenosis by comparing the findings with invasive catheterization, transthoracic (TTE) as well as tranesophageal echocardiography (TEE) and anatomic CMR examination of autopsy specimens. METHODS: Our study was performed in eight patients with aortic valve stenosis. Aortic stenosis was determined by TTE and TEE as well as catheterization and CMR. Especially, after aortic valve replacement, the explanted aortic valves were examined again with CMR ex vivo model. RESULTS: The mean AVA determined in vivo by CMR was 0.75 ± 0.09 cm(2) and ex vivo by CMR was 0.65 ± 0.09 cm(2) and was closely correlated (r = 0.91, p < 0.001). The mean absolute difference between AVA derived by CMR ex vivo and in vivo was -0.10 ± 0.04 cm(2). The mean AVA using TTE was 0.69 ± 0.07 with a significant correlation between CMR ex vivo (r = 0.85, p < 0.007) and CMR in vivo (r = 0.86, p < 0.008). CMR ex vivo and in vivo had no significant correlation with AVA using Gorlin formula by invasive catheterization or using planimetry by TEE. CONCLUSION: In this small study using an ex vivo aortic valve stenosis model, the aortic valve area can be reliably planimetered by CMR in vivo and ex vivo with a well correlation between geometric AVA by CMR and the effective AVA calculated by TTE.


Assuntos
Estenose da Valva Aórtica/patologia , Cateterismo Cardíaco/métodos , Ecocardiografia/métodos , Espectroscopia de Ressonância Magnética/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia Transesofagiana/métodos , Feminino , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos
11.
Eur Heart J ; 35(3): 192-9, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24164862

RESUMO

AIMS: Sleep-disordered breathing (SDB) may be a risk factor for expansion of infarct size early after acute myocardial infarction (MI) by exposing the heart to repetitive oxygen desaturations and increased cardiac afterload. The objective of this study was to assess the impact of SDB on myocardial salvage and infarct size within 3 months after acute MI. METHODS AND RESULTS: Patients with acute MI and percutaneous coronary intervention were enrolled in this prospective observational study. All patients underwent cardiovascular magnetic resonance (CMR) to define salvaged myocardium and infarct size within three to five days and at 3 months after acute MI. Patients were stratified according to apnoea-hypopnoea index (AHI) assessed by polysomnography at baseline into those with (AHI ≥ 15/h) and without (AHI < 15/h) SDB. Of the 56 patients included, 29 (52%) had SDB. The area at risk between both groups was similar (40 ± 12% vs. 40 ± 14%, P = 0.925). Patients with SDB had significantly less salvaged myocardium (myocardial salvage index 52% vs. 77%, P < 0.001), smaller reduction in infarct size (0.3% vs. 6.5%, P < 0.001) within 3 months after acute MI, a larger final infarct size (23% vs. 12%, P < 0.001), and a lower final left ventricular ejection fraction (48% vs. 54%, P = 0.023). In a multivariate analysis, including established risk factors for large MI, AHI was independently associated with less myocardial salvage and a larger infarct size 3 months after acute MI. CONCLUSIONS: Sleep-disordered breathing was associated with less myocardial salvage and a smaller reduction in infarct size. These findings suggest a contribution of SDB to impaired healing of MI.


Assuntos
Infarto do Miocárdio/patologia , Síndromes da Apneia do Sono/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea , Polissonografia , Estudos Prospectivos , Qualidade de Vida , Fatores de Risco , Terapia de Salvação , Síndromes da Apneia do Sono/complicações , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/patologia , Adulto Jovem
12.
Europace ; 16(2): 299-302, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23816515

RESUMO

AIMS: Extracorporeal membrane oxygenation (ECMO) is a very effective bridging therapy in patients with cardiogenic shock. To perform coronary angiography in these patients our group developed an unique system to get urgent vascular access with minimal additional vascular complication risk. The 6 Fr coronary catheters are introduced through a standard Y-connector, which is inserted into the arterial cannula of the ECMO-line close to the patient, the blind end of which is then equipped with a haemostatic valve (Check-Flo Performer accessory adapter, Cook Medical, USA). To the best of our knowledge, we here present the first patient, in whom this system had been used to insert an 8 Fr radiofrequency ablation catheter to treat incessant ventricular fibrillation. METHODS AND RESULTS: A 66-year-old patient had been transferred with electrical storm 5 days after an acute MI. After failed interventional and medical therapies an ECMO system had been inserted (right femoral artery cannula 15 Fr, left femoral vein cannula 21 Fr) and an electrophysiological study had been performed because of incessant ventricular fibrillation episodes, which always were induced by the same ventricular premature beat (VPB). During this first EP study over the left femoral artery the VPB could be targeted and successfully ablated. Unfortunately the VPB recovered again after some days so a second EP study had to be performed. This time the left femoral artery could not be used because of a postinterventional complication so we used the arterial cannula of the ECMO system as the access for the ablation catheter using a Y-connector. Using this way again a successful ablation procedure could be performed, after getting familiar with manipulation the ablation catheter over the ECMO cannula and with the help of different curved ablation catheters. The issue of compromising of the effective lumen of the arterial cannula by the ablation catheter`s cross sectional area could be overcome with increasing the rotational speed of the V-A ECMO. CONCLUSION: Ablation of ventricular arrhythmias using a Y-connector to insert the ablation catheter into the arterial cannula is feasible in patients with a V-A ECMO system avoiding additional arterial puncture with potentially major vascular complications in critically ill patients. Manipulation of the catheter is not as easy as using a standard sheath but can well be performed after a short habituation.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Oclusão Coronária/terapia , Oxigenação por Membrana Extracorpórea , Infarto do Miocárdio/terapia , Choque Cardiogênico/terapia , Fibrilação Ventricular/cirurgia , Idoso , Oclusão Coronária/complicações , Oclusão Coronária/diagnóstico , Oclusão Coronária/fisiopatologia , Desenho de Equipamento , Hemodinâmica , Humanos , Masculino , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/fisiopatologia , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/fisiopatologia , Resultado do Tratamento , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/fisiopatologia
13.
Clin Cardiol ; 46(11): 1337-1344, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37573576

RESUMO

BACKGROUND: Left atrial appendage closure (LAAC) is a mechanical alternative for stroke prevention in patients at risk who cannot tolerate oral anticoagulation (OAC). HYPOTHESIS: Our hypothesis was that the reduction of anticoagulation following LAAC results in a decrease of bleeding events and a rise in serum hemoglobin in a high-risk collective of patients with atrial fibrillation (AF). METHODS: Bleeding events, use of erythrocyte concentrates, anticoagulation, embolic events, and serum hemoglobin levels before and following LAAC were compared over more than 4 years. RESULTS: Seventy-five patients (CHA2DS2-VASc score 4.4 ± 1.7, HAS-BLED score 4.6 ± 1.1) were analyzed. Before LAAC (observation period 1.8 ± 1.8 years), 67 patients experienced 1.8 ± 1.4 bleeding events (0.9 ± 1.3 major) per year resulting in 0.7 ± 1.3 transfusions per year. After LAAC (2.6 ± 2.0 years), 26 patients (p < .0001 vs. before) had 0.6 ± 2.1 bleeding events (p < .0001), 0.2 ± 0.6 major bleedings (p < .0001) and received 0.6 ± 1.9 transfusions per year (p = .671). Fourteen patients had stroke before and 3 after LAAC (p = .008). Serum hemoglobin increased from initially 9.9 ± 3.0 to 11.9 ± 2.3 g/dL until the end of follow-up (p = .0005). Adverse embolic events did not differ before and after LAAC in our collective. CONCLUSION: In this clinical relevant cohort of AF patients with high risk for stroke and intolerance to OAC, we show that LAAC was able to reduce the rate of stroke and bleeding events, which translated into a rising serum hemoglobin concentration.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Embolia , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/cirurgia , Hemorragia/induzido quimicamente , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Anticoagulantes/efeitos adversos , Resultado do Tratamento
14.
Int J Cardiovasc Imaging ; 39(6): 1157-1165, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36961599

RESUMO

PURPOSE: Data derived by cardiac magnetic resonance (CMR) feature tracking suggest that not only left ventricular but also left atrial function is impaired in patients with acute myocarditis. Therefore, we investigated the diagnostic value of speckle tracking echocardiography of the left ventricle and left atrium in patients with acute myocarditis and normal left ventricular ejection fraction (LVEF). METHODS AND RESULTS: 30 patients with acute myocarditis confirmed by CMR according to the Lake Louise criteria and 20 healthy controls were analyzed including global longitudinal strain (GLS) and left atrial (LA) strain parameters. Although preserved LVEF was present in both groups, GLS was significantly lower in patients with acute myocarditis (GLS - 19.1 ± 1.8% vs. GLS - 22.1 ± 1.7%, p < 0.001). Further diastolic dysfunction measured by E/e' mean was significantly deteriorated in the myocarditis group compared to the control group (E/e' mean 6.4 ± 1.6 vs. 5.5 ± 1.0, p = 0.038). LA reservoir function (47.6 ± 10.4% vs. 55.5 ± 10.8%, p = 0.013) and LA conduit function (-33.0 ± 9.6% vs. -39.4 ± 9.5%, p = 0.024) were significantly reduced in patients with acute myocarditis compared to healthy controls. Also left atrial stiffness index (0.15 ± 0.05 vs. 0.10 ± 0.03, p = 0.003) as well as left atrial filling index (1.67 ± 0.47 vs. 1.29 ± 0.34, p = 0.004) were deteriorated in patients with myocarditis compared to the control group. CONCLUSION: In patients with acute myocarditis and preserved LVEF not only GLS but also LA reservoir function, LA conduit function and left atrial stiffness index as well as left atrial filling index were impaired compared to healthy controls indicating ventricular diastolic dysfunction and elevated LV filling pressures.


Assuntos
Fibrilação Atrial , Miocardite , Disfunção Ventricular Esquerda , Disfunção Ventricular , Humanos , Função Ventricular Esquerda , Volume Sistólico , Valor Preditivo dos Testes , Átrios do Coração/diagnóstico por imagem , Ecocardiografia/métodos , Disfunção Ventricular/patologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/patologia
15.
Clin Res Cardiol ; 112(5): 594-604, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36507943

RESUMO

AIMS: Sleep-disordered breathing (SDB) and its subtype central sleep apnoea (CSA) are highly prevalent in patients with heart failure and associated with worse prognosis. Whereas pharmacological therapy of heart failure has been shown to ameliorate CSA, results from previous studies on the effect of mitral regurgitation therapy on SDB are contradicting. The aim of this study was to assess the impact of transcatheter edge-to-edge mitral valve repair (TEER) on prevalence and severity of CSA. METHODS AND RESULTS: We enrolled 47 patients undergoing TEER for symptomatic mitral regurgitation in a prospective study. Secondary mitral regurgitation and left ventricular ejection fraction < 50% were present in 79% and 68% of patients, respectively. Respiratory polygraphy was performed before TEER in a compensated condition and four weeks after the procedure. 34 patients completed the follow-up. At baseline, 19 (56%) patients showed moderate-to-severe SDB, of whom 13 (68%) were classified as CSA. Both apnoea-hypopnoea index and percentage of recorded time spent in Cheyne-Stokes respiration strongly decreased from baseline to follow-up (median [IQR] 16 [7-30] vs. 7 [4-15] /h, p = 0.007; 6 [0-34] vs. 0 [0-8] %, p = 0.008). Median relative reduction of central apnoea index was 75% (p = 0.023), while obstructive apnoea index did not change significantly. Increase in stroke volume after TEER and high systolic pulmonary artery pressure at baseline predicted a > 50% reduction of both Apnoea-hypopnoea index and Cheyne-Stokes respiration. CONCLUSION: TEER is associated with a significant short-term reduction of CSA and Cheyne-Stokes respiration in high-risk patients, strengthening its value as an effective treatment option for advanced heart failure.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Síndromes da Apneia do Sono , Apneia do Sono Tipo Central , Humanos , Respiração de Cheyne-Stokes/terapia , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Volume Sistólico , Valva Mitral/cirurgia , Estudos Prospectivos , Função Ventricular Esquerda , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/diagnóstico , Resultado do Tratamento
16.
J Cardiovasc Dev Dis ; 10(3)2023 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-36975862

RESUMO

BACKGROUND: Pulmonary vein (PV) reconnection is the major cause of atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI). The probability of reconnection is higher if the primary lesion is not sufficiently effective, which can be unmasked with an adenosine provocation test (APT). High-power short-duration radiofrequency energy (HPSD) guided with ablation index (AI) and the third generation of the visually guided laser balloon (VGLB) are new methods for PVI. METHODS: A total of 70 participants (35 in each group) who underwent a PVI with either AI-guided HPSD (50 W; AI 500 for the anterior and 400 for the posterior wall, respectively) or VGLB ablation were included in this observational pilot trial. Twenty minutes after each PVI, an APT was performed. The primary endpoint was the event-free survival from AF after three years. RESULTS: A total of 137 (100%) PVs in the HPSD arm and 131 PVs (98.5%) in the VGLB arm were initially successfully isolated (p = 0.24). The overall procedure duration was similar in both arms (155 ± 39 in HPSD vs. 175 ± 58 min in VGLB, p = 0.191). Fluoroscopy time, left atrial dwelling time and duration from the first to the last ablation were longer in the VGLB arm (23 ± 8 vs. 12 ± 3 min, p < 0.001; 157 (111-185) vs. 134 (104-154) min, p = 0.049; 92(59-108) vs. 72 (43-85) min, p = 0.010). A total of 127 (93%) in the HPSD arm and 126 (95%) PVs in the VGLB arm remained isolated after APT (p = 0.34). The primary endpoint was met 1107 ± 68 days after ablation in 71% vs. 66% in the VGLB and HPSD arms, respectively (p = 0.65). CONCLUSIONS: HPSD and VGLB did not differ with respect to long-term outcome of PVI. A large, randomized study should be conducted to compare clinical outcomes with respect to these new ablation techniques.

17.
J Cardiovasc Dev Dis ; 10(12)2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38132641

RESUMO

BACKGROUND: Coronary collateral flow in angiography has been linked with lower mortality rates in patients with coronary artery disease. However, the relevance of the underlying mechanism is sparse. Therefore, we tested the hypothesis that in patients with acute myocardial infarction (AMI), relevant coronary collateral flow is associated with more salvaged myocardium and lower risk of developing heart failure. METHODS AND RESULTS: Patients with first AMI who received a percutaneous coronary intervention within 24 h after symptom onset were classified visually by assigning a Cohen-Rentrop Score (CRS) ranging between 0 (no collaterals) and 3 (complete retrograde filling of the occluded vessel). All 36 patients included in the analysis underwent cardiac magnetic resonance examination within 3 to 5 days after myocardial infarction and after 12 weeks. Patients with relevant collateral flow (CRS 2-3) to the infarct-related artery had significantly smaller final infarct size compared to those without (7 ± 4% vs. 20 ± 12%, p < 0.001). In addition, both groups showed improvement in left ventricular ejection fraction early after AMI, whereas the recovery was greater in CRS 2-3 (+8 ± 5% vs. +3 ± 5%, p = 0.015). CONCLUSION: In patients with first AMI, relevant collateral flow to the infarct-related artery was associated with more salvaged myocardium at 12 weeks, translating into greater improvement of systolic left ventricular function. The protective effect of coronary collaterals and the variance of infarct location should be further investigated in larger studies.

18.
Eur Respir J ; 40(5): 1173-9, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22441744

RESUMO

The aim of this study was to test whether an improvement of left ventricular ejection fraction (EF) in the early phase after acute myocardial infarction is associated with a reduction of the severity of central and obstructive sleep apnoea. 40 consecutive patients with acute myocardial infarction underwent polysomnography and cardiovascular magnetic resonance imaging within 5 days and 12 weeks after the event to assess sleep apnoea and cardiac function. We stratified the sample in patients who improved their left ventricular EF within 12 weeks by ≥ 5% (improved EF group, ΔEF 9 ± 1%, n=16) and in those who did not (unchanged EF group, ΔEF -1 ± 1%, n=24). Prevalence of sleep apnoea (≥ 15 apnoea and hypopnoea events·h(-1)) within ≤ 5 days after myocardial infarction was 55%. Apnoea and hypopnoea events·h(-1) were significantly more reduced in the improved EF group compared with the unchanged EF group (-10 ± 3 versus 1 ± 3 events·h(-1); p=0.036). This reduction was based on a significant alleviation of obstructive events (-7 ± 2 versus 4 ± 3 events·h(-1); p=0.009), while the reduction of central events was similar between groups (p=0.906). An improvement of cardiac function early after myocardial infarction is associated with an alleviation of sleep apnoea. This finding suggests that re-evaluation of treatment indication for sleep apnoea is needed when a change in cardiac function occurs.


Assuntos
Infarto do Miocárdio/fisiopatologia , Síndromes da Apneia do Sono/fisiopatologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Estudos Prospectivos , Síndromes da Apneia do Sono/complicações , Adulto Jovem
19.
J Cardiovasc Magn Reson ; 14: 61, 2012 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-22938651

RESUMO

BACKGROUND: Perfusion-cardiovascular magnetic resonance (CMR) is generally accepted as an alternative to SPECT to assess myocardial ischemia non-invasively. However its performance vs gated-SPECT and in sub-populations is not fully established. The goal was to compare in a multicenter setting the diagnostic performance of perfusion-CMR and gated-SPECT for the detection of CAD in various populations using conventional x-ray coronary angiography (CXA) as the standard of reference. METHODS: In 33 centers (in US and Europe) 533 patients, eligible for CXA or SPECT, were enrolled in this multivendor trial. SPECT and CXA were performed within 4 weeks before or after CMR in all patients. Prevalence of CAD in the sample was 49% and 515 patients received MR contrast medium. Drop-out rates for CMR and SPECT were 5.6% and 3.7%, respectively (ns). The study was powered for the primary endpoint of non-inferiority of CMR vs SPECT for both, sensitivity and specificity for the detection of CAD (using a single-threshold reading), the results for the primary endpoint were reported elsewhere. In this article secondary endpoints are presented, i.e. the diagnostic performance of CMR versus SPECT in subpopulations such as multi-vessel disease (MVD), in men, in women, and in patients without prior myocardial infarction (MI). For diagnostic performance assessment the area under the receiver-operator-characteristics-curve (AUC) was calculated. Readers were blinded versus clinical data, CXA, and imaging results. RESULTS: The diagnostic performance (= area under ROC = AUC) of CMR was superior to SPECT (p = 0.0004, n = 425) and to gated-SPECT (p = 0.018, n = 253). CMR performed better than SPECT in MVD (p = 0.003 vs all SPECT, p = 0.04 vs gated-SPECT), in men (p = 0.004, n = 313) and in women (p = 0.03, n = 112) as well as in the non-infarct patients (p = 0.005, n = 186 in 1-3 vessel disease and p = 0.015, n = 140 in MVD). CONCLUSION: In this large multicenter, multivendor study the diagnostic performance of perfusion-CMR to detect CAD was superior to perfusion SPECT in the entire population and in sub-groups. Perfusion-CMR can be recommended as an alternative for SPECT imaging. TRIAL REGISTRATION: ClinicalTrials.gov, Identifier: NCT00977093.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Circulação Coronária , Imagem Cinética por Ressonância Magnética/métodos , Isquemia Miocárdica/diagnóstico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Doença da Artéria Coronariana/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
20.
Sleep Med ; 94: 63-69, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35490662

RESUMO

BACKGROUND: Left ventricular diastolic dysfunction is a predictor of adverse outcome after acute myocardial infarction (AMI). We aimed to test if sleep-disordered breathing (SDB) contributes to the development of diastolic dysfunction in patients with preserved left ventricular ejection fraction after AMI. METHOD: Patients with AMI, percutaneous coronary intervention and an ejection fraction ≥50% were included in this sub-analysis of a prospective observational study. Patients with AMI (n = 41) underwent cardiovascular magnetic resonance imaging (volume-time curve analysis) to define diastolic function by means of the normalised peak filling rate [nPFR; (end diastolic volume/second)]. In patients with AMI, the nPFR was assessed within <5 days and three months after AMI. Patients with AMI were stratified in patients with (apnoea-hypopnoea index, AHI ≥15/h) and without (AHI <15/h) SDB as assessed by polysomnography. RESULTS: At the time of AMI, the nPFR was similar between patients with and without SDB (2.90 ± 0.54 vs. 3.03 ± 1.20, p = 0.662). Within three months after AMI, diastolic function was significantly lower in patients with SDB than in patients without SDB (ΔnPFR: -0.83 ± 0.14 vs. 0.03 ± 0.14; p < 0.001; ANCOVA, adjusted for baseline nPFR). In contrast to central AHI, obstructive AHI was associated with a lower nPFR three months after AMI, after accounting for established risk factors for diastolic dysfunction [multiple linear regression analysis, B (95%CI): -0.036 (-0.063 to -0.009), p = 0.011]. CONCLUSION: Our data indicate that obstructive sleep apnoea impairs diastolic function early after myocardial infarction.


Assuntos
Infarto do Miocárdio , Síndromes da Apneia do Sono , Apneia Obstrutiva do Sono , Humanos , Infarto do Miocárdio/complicações , Polissonografia/métodos , Síndromes da Apneia do Sono/complicações , Apneia Obstrutiva do Sono/complicações , Volume Sistólico , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa