Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Acta Clin Croat ; 62(Suppl2): 46-52, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38966016

RESUMO

Chronic kidney disease (CKD) is among the most significant health problems, with the associated cardiovascular disease and bone metabolism disorders being the leading cause of morbidity and mortality in these patients. The aim of the study was to determine markers of bone turnover in patient sera (phosphates, calcium, alkaline phosphatase, parathyroid hormone and osteoprotegerin (OPG)) in all stages of kidney failure including kidney transplant recipients. We also wanted to determine whether dialysis vintage affects recovery of bone markers one year after transplantation. There were 164 study patients, whereas 30 healthy individuals served as a control group. Serum OPG progressively increased with decline of the glomerular filtration rate. The highest OPG concentration was recorded in dialysis group. We observed a statistically significant OPG increase in stage 2 CKD. In kidney transplant group, there was positive correlation between OPG and dialysis vintage. We also found that serum OPG was lower in patients treated with dialysis for less than 4 years prior to transplantation. We confirmed that CKD-mineral and bone disorder began in stage 3 CKD with parathyroid hormone and OPG elevation, and a statistically significant OPG increase in stage 2 CKD might be an early sign of CKD-mineral and bone disorder. Dialysis vintage longer than 4 years is associated with more significant disturbances in mineral and bone metabolism.


Assuntos
Biomarcadores , Osteoprotegerina , Diálise Renal , Humanos , Osteoprotegerina/sangue , Masculino , Feminino , Pessoa de Meia-Idade , Biomarcadores/sangue , Distúrbio Mineral e Ósseo na Doença Renal Crônica/sangue , Distúrbio Mineral e Ósseo na Doença Renal Crônica/diagnóstico , Distúrbio Mineral e Ósseo na Doença Renal Crônica/etiologia , Adulto , Transplante de Rim , Insuficiência Renal Crônica/sangue , Insuficiência Renal Crônica/terapia , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/complicações , Hormônio Paratireóideo/sangue , Idoso , Taxa de Filtração Glomerular
2.
Clin Nephrol ; 91(6): 334-343, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30848241

RESUMO

INTRODUCTION: Clinical assessment (CA) is frequently used for the evaluation of volume status in peritoneal dialysis (PD) patients despite its subjectivity. Multiple-frequency bioelectrical impedance analysis (MF-BIA) is objective, accurate, and quick, proving to be a promising technique for measuring volume status. The aim of this study was to assess volume status in PD patients using CA and MF-BIA and to compare results. MATERIALS AND METHODS: Incident PD patients were prospectively analyzed between January 1, 2014, and January 1, 2016, at the Clinical Hospital Center of -Rijeka, Croatia. Volume status measurements were performed once a month for 6 consecutive months. The presence of symptoms and signs associated with hyper- or hypovolemia were detected by CA. Euvolemia was defined as a symptom-free state or up to 2 symptoms maximum. Patients lacking up to 1.2 L of volume or with up to 1.2 L in excess were considered euvolemic, as measured by MF-BIA. RESULTS: A total of 45 PD patients were analyzed; 51% were men, 27% were diabetic, the mean age was 52 ± 26 years, and PD duration was 11.5 ± 6.5 months. In comparison to MF-BIA, CA showed a significant difference in detected hypervolemia between baseline and follow-up (p = 0.708 vs. p = 0.01, respectively) and among all measurements (p < 0.01). Contrary to CA, volume status measured by MF-BIA correlated significantly with systolic and diastolic blood pressure (R = 0.29; p ≤ 0.01 and R = 0.26; p ≤ 0.01, respectively). CA showed low sensitivity (0.24) and high specificity (0.92) in detecting hypervolemia. CONCLUSION: MF-BIA is an effective, objective, and safe method for assessing volume status in PD patients. Longitudinal monitoring of body composition changes - including hydration state - leading to adequate therapeutic intervention is a promising and potential application of MF-BIA along with CA.


Assuntos
Volume Sanguíneo , Impedância Elétrica , Nefropatias/fisiopatologia , Nefropatias/terapia , Diálise Peritoneal/efeitos adversos , Avaliação de Sintomas , Adulto , Idoso , Pressão Sanguínea , Composição Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Adulto Jovem
3.
Acta Med Croatica ; 68(1): 43-8, 2014 Mar.
Artigo em Servo-Croata (Latino) | MEDLINE | ID: mdl-24979896

RESUMO

Providing health care and good hospital organization are always based on a well-educated and competent nurse. Nurses can significantly affect the result of overall treatment, which has a professional and financial effect. Nursing Informatics is a specialty that integrates nursing, computer and information science applied to nursing management as well as transfer of data, information and knowledge in nursing practice. This facilitates nurses' integration in supporting decision-making and implementation of health care. Informatics emphasizes overall nursing practice and nurses should have basic computer skills. In this article, we show how the use of simple tables, designed by using Microsoft Office programs (Word and Excel), has been employed for over a decade in facilitating the organization of daily work, monitoring of patients and their prescribed therapy. A trained nurse-manager will be able to evaluate patient care and to organize health care administration using all human and technical resources. The vision of the national health care system is still not achievable due to the lack of infrastructure. Nurses and computer documentation of patients with chronic kidney disease can significantly improve the quality of patient care and treatment.


Assuntos
Sistemas de Informação em Saúde , Cuidados de Enfermagem/métodos , Diálise Renal/enfermagem , Registros Eletrônicos de Saúde , Humanos , Nefropatias/enfermagem , Qualidade da Assistência à Saúde , Software
4.
Wien Klin Wochenschr ; 127(11-12): 451-8, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25854911

RESUMO

BACKGROUND: In recent years, nonalcoholic fatty liver disease (NAFLD) was recognized as an important factor in chronic kidney disease (CKD) pathogenesis. The concentrations of serum aminotransferases in both chronic dialysis and chronic renal failure (CRF) patients most commonly fall within the lower end of the range of normal values. The aim of the present study was to investigate the usefulness of four liver tests and four biological scores in detection of NAFLD in comparison with transient elastography (TE) findings in different groups of patients. METHODS: The study was cross-sectional analysis collected data from a single tertiary care center. Of 202 patents there were 52 patients with CKD, 50 patients with end-stage renal disease (ESRD) treated with haemodialysis (HD), 50 renal transplant recipients (RTRs) and 50 patients with proven coronary heart disease (CHD). Fifty sex- and age-matched individuals without NAFLD and with normal liver and kidney function tests served as controls. With the help of TE (FibroScan®, Echosense SA, Paris, France), liver stiffness was selected as the parameter to quantify liver fibrosis and Controlled Attenuation Parameter (CAP) was used to detect and quantify liver steatosis. RESULTS: According to the CAP findings 76.9 %CKD patients, 82 %HD patients, 74 %RTRs and 69.1 % CHD patients had CAP > 238 dB.m(-1) and thus by definition NAFLD. We have found that ALT, AST and GGT levels were positively correlated with CAP values while ALT and AST showed positive correlation with liver stiffness acquired with TE only in CHD patients. According to TE findings APRI (AUC 0.796) and FIB-4 (AUC 0.790) scores were correlated with the presence of fibrosis, while HIS score was correlated with the presence of steatosis (AUC 0.867) only in CHD patients. CONCLUSION: Liver tests and biological scores are not useful for NAFLD detection in CRF patients. TE with CAP provides the opportunity of noninvasive screening for NAFLD as well as liver fibrosis in patients with CRF.


Assuntos
Doença da Artéria Coronariana/complicações , Técnicas de Imagem por Elasticidade/métodos , Falência Renal Crônica/complicações , Testes de Função Hepática/métodos , Hepatopatia Gordurosa não Alcoólica/complicações , Hepatopatia Gordurosa não Alcoólica/diagnóstico , Idoso , Biomarcadores/sangue , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/diagnóstico , Estudos Transversais , Feminino , Humanos , Falência Renal Crônica/sangue , Falência Renal Crônica/diagnóstico , Masculino , Hepatopatia Gordurosa não Alcoólica/sangue , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Hemodial Int ; 19(3): 472-81, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25688578

RESUMO

Non-alcoholic fatty liver disease (NAFLD) is an important factor in the pathogenesis of cardiovascular diseases in the general population. Recently, it has been shown that NAFLD is highly prevalent in chronic kidney disease (CKD) patients. Ninety-four hemodialysis (HD) patients were followed for a time period of 18 months or until death. Patient's survival rate was determined in relation to their nutritional and inflammatory state, and the presence of NAFLD. We also investigated the association between the presence of NAFLD and the patients' nutritional and inflammatory state. We did not find any significant association between the clinical parameters of nutritional status and the mortality rate. However, the mortality rate was statistically significantly higher in patients with low serum albumin and high high-sensitive C-reactive protein (hs-CRP) levels and in those who had NAFLD. Surprisingly, patients who had received enteral nutrition did not have a better survival rate. The severity of liver steatosis was negatively correlated with the serum albumin levels, while it was positively correlated with hs-CRP values. Furthermore, serum albumin levels showed a negative correlation with hs-CRP levels. We did not find any significant association between the presence of NAFLD and clinical parameters of nutrition. We have shown that NAFLD could be one more possible example of reverse epidemiology in patients undergoing HD. NAFLD may be the missing link that causally ties malnutrition, inflammation, and atherosclerosis syndrome to the morbidity and mortality in patients undergoing HD.


Assuntos
Aterosclerose/sangue , Proteína C-Reativa/análise , Inflamação/sangue , Desnutrição/sangue , Hepatopatia Gordurosa não Alcoólica/complicações , Diálise Renal/métodos , Insuficiência Renal Crônica/complicações , Adulto , Idoso , Idoso de 80 Anos ou mais , Aterosclerose/etiologia , Aterosclerose/fisiopatologia , Proteína C-Reativa/metabolismo , Feminino , Humanos , Masculino , Desnutrição/etiologia , Desnutrição/fisiopatologia , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/mortalidade , Estado Nutricional , Prevalência , Estudos Prospectivos , Insuficiência Renal Crônica/mortalidade , Taxa de Sobrevida
6.
Ren Fail ; 27(5): 601-4, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16153000

RESUMO

BACKGROUND: The hemodialysis adequacy is one of the most important issues influencing the survival of patients on maintenance hemodialysis (HD). Assessment of measuring the delivered dialysis dose using clearance x time/volume (Kt/V) index requires multiple blood sampling. New methods for assessment of dialysis dose based on ionic dialysance (ID) have been suggested. Online conductivity monitoring (using sodium flux as a surrogate for urea) allows the repeated noninvasive measurement of Kt/V on each HD treatment. In this study we have compared this method with the standard method of estimating Kt/V. METHODS: We studied 24 established HD patients over a 4 week time period. Patients were dialyzed using Fresenius 4008S dialysis monitors, equipped with modules to measure ID. Data were manually collected and analyzed using the appropriate statistical software. Urea removal (UR) was measured once a week by a two-pool calculation, estimating an eKt/V. RESULTS: The Kt/V measured by ID highly correlated with the one derived from the measurement of the UR (r=0.8959, p< 0.0001). The ID underestimated UR by the mean of 6%. The ID varied greatly within individual patients with a median of 1.29 +/- 0.22. If the eKt/V > or = 1.2 is considered adequate, 33% of the patients would have been inadequately dialyzed. The mean HD duration to achieve an adequate dialysis was 4 hours and 47 minutes with high interpatient variability. CONCLUSION: The ID seems to be an easily obtained measure of the delivered dialysis dose, correlating well with standard UR method. Substantial individual variations imply that repeated measures (ideally for all treatments) are necessary to obtain a real answer to the mean treatment dose being delivered to the patients.


Assuntos
Soluções para Diálise/uso terapêutico , Falência Renal Crônica/terapia , Diálise Renal/instrumentação , Ureia/urina , Estudos de Coortes , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Seguimentos , Humanos , Falência Renal Crônica/diagnóstico , Testes de Função Renal , Masculino , Monitorização Fisiológica/métodos , Probabilidade , Diálise Renal/métodos , Medição de Risco , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa