1.
Clin Chem Lab Med ; 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39016272

RESUMO

The first part of this Inter-Society Document describes the mechanisms involved in the development of cardiovascular diseases, particularly arterial hypertension, in adults and the elderly. It will also examine how consistent physical exercise during adolescence and adulthood can help maintain blood pressure levels and prevent progression to symptomatic heart failure. The discussion will include experimental and clinical evidence on the use of specific exercise programs for preventing and controlling cardiovascular diseases in adults and the elderly. In the second part, the clinical relevance of cardiac-specific biomarkers in assessing cardiovascular risk in the general adult population will be examined, with a focus on individuals engaged in sports activities. This section will review recent studies that suggest a significant role of biomarkers in assessing cardiovascular risk, particularly the presence of cardiac damage, in athletes who participate in high-intensity sports. Finally, the document will discuss the potential of using cardiac-specific biomarkers to monitor the effectiveness of personalized physical activity programs (Adapted Physical Activity, APA). These programs are prescribed for specific situations, such as chronic diseases or physical disabilities, including cardiovascular diseases. The purposes of this Inter-Society Document are the following: 1) to discuss the close pathophysiological relationship between physical activity levels (ranging from sedentary behavior to competitive sports), age categories (from adolescence to elderly age), and the development of cardiovascular diseases; 2) to review in detail the experimental and clinical evidences supporting the role of cardiac biomarkers in identifying athletes and individuals of general population at higher cardiovascular risk; 3) to stimulate scientific societies and organizations to develop specific multicenter studies that may take into account the role of cardiac biomarkers in subjects who follow specific exercise programs in order to monitor their cardiovascular risk.

2.
Clin Chem Lab Med ; 61(7): 1209-1229, 2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-36695506

RESUMO

In accordance with all the most recent international guidelines, the variation of circulating levels of cardiac troponins I and T, measured with high-sensitivity methods (hs-cTnI and hs-cTnT), should be used for the detection of acute myocardial injury. Recent experimental and clinical evidences have demonstrated that the evaluation of hs-cTnI and hs-cTnT variations is particularly relevant: a) for the differential diagnosis of Acute Coronary Syndromes (ACS) in patients admitted to the Emergency Department (ED); b) for the evaluation of cardiovascular risk in patients undergoing major cardiac or non-cardiac surgery, and in asymptomatic subjects of the general population aged >55 years and with co-morbidities; c) for the evaluation of cardiotoxicity caused by administration of some chemotherapy drugs in patients with malignant tumors. The aim of this document is to discuss the fundamental statistical and biological considerations on the intraindividual variability of hs-cTnI and hs-cTnT over time in the same individual. Firstly, it will be discussed in detail as the variations of circulating levels strictly depend not only on the analytical error of the method used but also on the intra-individual variability of the biomarker. Afterwards, the pathophysiological interpretation and the clinical relevance of the determination of the variability of the hs-cTnI and hs-cTnT values ​​ in patients with specific clinical conditions are discussed. Finally, the evaluation over time of the variation in circulating levels of hs-cTnI and hs-cTnT is proposed for a more accurate estimation of cardiovascular risk in asymptomatic subjects from the general population.


Assuntos
Síndrome Coronariana Aguda , Doenças Cardiovasculares , Humanos , Doenças Cardiovasculares/diagnóstico , Relevância Clínica , Troponina T , Síndrome Coronariana Aguda/diagnóstico , Biomarcadores , Troponina I
3.
Clin Chem Lab Med ; 60(10): 1525-1542, 2022 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-35858238

RESUMO

Major adverse cardiovascular events are frequently observed in patients undergoing major non-cardiac surgery during the peri-operative period. At this time, the possibility to predict cardiovascular events remains limited, despite the introduction of several algorithms to calculate the risk of adverse events, mainly death and major adverse cardiovascular events (MACE) based on the clinical history, risk factors (sex, age, lipid profile, serum creatinine) and non-invasive cardiac exams (electrocardiogram, echocardiogram, stress tests). The cardiac-specific biomarkers natriuretic peptides (NPs) and cardiac troponins (cTn) have been proposed as additional tools for risk prediction in the peri-operative period, particularly for the identification of myocardial injury in patients undergoing major non-cardiac surgery. The prognostic information from the measurement of BNP/NT-proBNP and hs-cTn is independent and complementary to other important indicators of risk, also including ECG and imaging techniques. Elevated levels of cardiac-specific biomarkers before surgery are associated with a markedly higher risk of MACE during the peri-operative period. BNP/NT-proBNP and hs-cTn should be measured in all patients during the clinical evaluation before surgery, particularly during intermediate- or high-risk surgery, in patients aged >65 years and/or with comorbidities. Several questions remain to be assessed in dedicated clinical studies, such as how to optimize the management of patients with raised cardiac specific biomarkers before surgery, and whether a strategy based on biomarker measurement improves patient outcomes and is cost-effective.


Assuntos
Doenças Cardiovasculares , Biomarcadores , Fatores de Risco de Doenças Cardíacas , Humanos , Peptídeo Natriurético Encefálico , Fragmentos de Peptídeos , Prognóstico , Medição de Risco , Fatores de Risco
4.
Clin Chem Lab Med ; 60(2): 169-182, 2022 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-34927403

RESUMO

Serial measurements of cardiac troponin are recommended by international guidelines to diagnose myocardial infarction (MI) since 2000. However, some relevant differences exist between the three different international guidelines published between 2020 and 2021 for the management of patients with chest pain and no ST-segment elevation. In particular, there is no agreement on the cut-offs or absolute change values to diagnose non-ST-segment elevation MI (NSTEMI). Other controversial issues concern the diagnostic accuracy and cost-effectiveness of cut-off values for the most rapid algorithms (0 h/1 h or 0 h/2 h) to rule-in and rule-out NSTEMI. Finally, another important point is the possible differences between demographic and clinical characteristics of patients enrolled in multicenter trials compared to those routinely admitted to the Emergency Department in Italy. The Study Group of Cardiac Biomarkers, supported by the Italian Scientific Societies Società Italiana di Biochimica Clinica, Italian Society of the European Ligand Assay Society, and Società Italiana di Patolgia Clinica e Medicina di Laboratorio decided to revise the document previously published in 2013 about the management of patients with suspected NSTEMI, and to provide some suggestions for the use of these biomarkers in clinical practice, with a particular focus on the Italian setting.


Assuntos
Infarto do Miocárdio , Infarto do Miocárdio sem Supradesnível do Segmento ST , Algoritmos , Biomarcadores , Serviço Hospitalar de Emergência , Humanos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Troponina
5.
Clin Chem Lab Med ; 58(10): 1663-1672, 2020 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-31927515

RESUMO

Background The comparability of thyroid-stimulating hormone (TSH) results cannot be easily obtained using SI-traceable reference measurement procedures (RPMs) or reference materials, whilst harmonization is more feasible. The aim of this study was to identify and validate a new approach for the harmonization of TSH results. Methods Percentile normalization was applied to 125,419 TSH results, obtained from seven laboratories using three immunoassays (Access 3rd IS Thyrotropin, Beckman Coulter Diagnostics; Architect System, Abbott Diagnostics and Elecsys, Roche Diagnostics). Recalibration equations (RCAL) were derived by robust regressions using bootstrapped distribution. Two datasets, the first of 119 EQAs, the second of 610, 638 and 639 results from Access, Architect and Elecsys TSH results, respectively, were used to validate RCAL. A dataset of 142,821 TSH values was used to derive reference intervals (RIs) after applying RCAL. Results Access, Abbott and Elecsys TSH distributions were significantly different (p < 0.001). RCAL intercepts and slopes were -0.003 and 0.984 for Access, 0.032 and 1.041 for Architect, -0.031 and 1.003 for Elecsys, respectively. Validation using EQAs showed that before and after RCAL, the coefficients of variation (CVs) or among-assay results decreased from 10.72% to 8.16%. The second validation dataset was used to test RCALs. The median of between-assay differences ranged from -0.0053 to 0.1955 mIU/L of TSH. Elecsys recalibrated to Access (and vice-versa) showed non-significant difference. TSH RI after RCAL resulted in 0.37-5.11 mIU/L overall, 0.49-4.96 mIU/L for females and 0.40-4.92 mIU/L for males. A significant difference across age classes was identified. Conclusions Percentile normalization and robust regression are valuable tools for deriving RCALs and harmonizing TSH values.


Assuntos
Imunoensaio/métodos , Tireotropina/sangue , Calibragem , Sistemas de Informação em Laboratório Clínico , Humanos , Valores de Referência , Reprodutibilidade dos Testes , Tireotropina/normas
6.
Clin Chem Lab Med ; 57(4): 521-531, 2019 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-30218601

RESUMO

Background [-2]proPSA seems to outperform free/total prostate-specific antigen (PSA) ratio in prostate cancer diagnosis. However, [-2]proPSA stability remains an underestimated issue. We examined [-2]proPSA stability over time in whole blood before separation of serum and plasma and its implications for prostate health index (Phi) determination. Total PSA (tPSA) and free PSA (fPSA) stabilities were also assessed. Methods Blood was drawn from 26 patients and separated in two tubes for plasma (K2EDTA and K2EDTA plus protease inhibitors - P100) and one for serum (clot activator plus gel separator). Tubes were stored at room temperature before centrifugation 1, 3 and 5 h for serum and EDTA plasma or 1 and 5 h for P100 plasma. To investigate the influence of gel separator on markers' stability, blood was collected from 10 patients in three types of tubes to obtain serum: tubes with clot activator plus gel separator, with silica particles or glass tubes. Biomarkers were assayed with chemiluminescent immunoassays. Results [-2]proPSA and Phi levels significantly and progressively increased over time in serum (+4.81% and +8.2% at 3 h; +12.03% and +14.91% at 5 h, respectively, vs. 1 h; p<0.001). Conversely, [-2]proPSA levels did not change in plasma (EDTA or P100). tPSA levels did not change over time in serum or plasma, whereas fPSA decreased in serum. All markers were higher in plasma than in serum at any time point. This difference did not seem to be attributable to the use of gel for serum preparation. Conclusions EDTA prevented spurious in vitro modifications in PSA-related isoforms, confirming that a stabilized blood sample is a prerequisite for [-2]proPSA measurement and Phi determination.


Assuntos
Biomarcadores Tumorais/sangue , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Temperatura , Idoso , Idoso de 80 Anos ou mais , Ácido Edético , Humanos , Imunoensaio , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/diagnóstico
7.
Scand J Clin Lab Invest ; 79(4): 260-267, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30982358

RESUMO

The aim of the present study was to investigate serum HER2 extracellular domain (ECD) as a putative surrogate marker of the shedding phenomenon of HER2 receptor from the tumor tissue of primary breast cancer (BC) patients. A pilot retrospective study was conducted on 100 matched serum and tissue samples from patients with node-positive primary BC, stage II/III. Analysis of association and concordance between serum HER2 ECD levels (measured by chemiluminescence immunoassay) and the expression in matched tumor tissue of HER2 ECD and intracellular receptor domain (ICD) (determined by immunohistochemistry) were performed. The median serum HER2 ECD level was 9.4 ng/ml and cutoff values were set at 15.2 ng/ml or 13.0 ng/ml. HER2 ICD and ECD were overexpressed in tumor tissue of 19.8% and 6.9% of patients, respectively. Statistically significant associations were found between serum HER2 ECD levels and tissue expression of both HER2 ICD and ECD (p < .001; Fisher analysis). Moreover, strong concordances were found between serum HER2 ECD levels and tissue expression of HER2 ICD or ECD (cutoff 15.2 ng/ml: 80 and 92.5%, respectively). Our findings support a role for serum HER2 ECD as a surrogate marker of tissue HER2 status in primary BC, both for HER2 ICD or ECD expression.


Assuntos
Neoplasias da Mama/metabolismo , Espaço Extracelular/metabolismo , Receptor ErbB-2/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/sangue , Neoplasias da Mama/cirurgia , Feminino , Humanos , Espaço Intracelular , Pessoa de Meia-Idade , Domínios Proteicos , Receptor ErbB-2/sangue , Receptor ErbB-2/química
8.
Clin Chem Lab Med ; 57(2): 259-267, 2018 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-30016276

RESUMO

Background The aims of this study were: (1) to calculate reliable thyroid stimulating hormone (TSH) reference intervals using laboratory databases; (2) to evaluate the relationship between TSH, sex and age values in different large Italian populations. Methods The TSH values stored in the laboratory information system of clinical laboratories of four Italian city hospitals, including 146,801 TSH measurements (with the respective age and sex data of individuals) were taken in consideration. Assuming a log-normal distribution, to log-transformed TSH values were applied the Dixon's iterative principle in order to exclude the outliers. At the end of this iterative process 142,821 log-transformed TSH results remained. The four clinical laboratories measured serum TSH concentrations using the same TSH immunoassay method (Access TSH 3rd IS, using UniCel DxI platform). Results The TSH reference interval calculated in the present study (0.362-5.280 mIU/L) is similar to that suggested by the manufacturer for the Access TSH 3rd IS assay (0.45-5.33 mIU/L). TSH values in females were significantly higher than in males (females: mean=2.06 mIU/L; standard deviation [SD]=1.26 mIU/L; n=101,243; males: mean=1.92 mIU/L; SD=1.19 mIU/L; n=41,578; p<0.0001). Moreover, a negative linear relationship was observed between TSH throughout all interval age values (from 0 to 105 years). Conclusions The results of the present multicenter study confirm that data mining techniques can be used to calculate clinically useful reference intervals for TSH. From a pathophysiological point of view, our results suggest that some Northern populations of Italy might still suffer some harmful effects on the thyroid gland due to mild to moderate iodine intake deficiency. Specific clinical trials are needed to confirm these results.


Assuntos
Tireotropina/sangue , Tireotropina/normas , Adulto , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Padrões de Referência
9.
Clin Chem Lab Med ; 56(3): 397-402, 2018 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-29220884

RESUMO

It is well known that the results of immunoassay methods can be affected by specific or non-specific interferences, ranging from 0.4% to 4.0%. The presence of interference may greatly compromise the accuracy of immunoassay analyses causing an error in the measurement, producing false-positive or false-negative results. From a clinical point of view, these analytical errors may have serious implications for patient care because they can cause misdiagnosis or inappropriate treatment. Unfortunately, it is a very difficult task to identify the irregular analytical errors related to immunoassay methods because they are not detectable by normal laboratory quality control procedures, are reproducible within the test system, may be clinically plausible and are relatively rare. The first line of defense against erroneous results is to use in laboratory practice only immunoassay systems with the highest level of robustness against interference. The second line of defense is always taking into account the possibility of interference in immunoassay results. A correct approach should be addressed on identification of samples at high risk of interference. The attainment of this goal requires a critical review of the test result in relation to patient's clinical conditions and literature data, taking into account the analytical characteristics of the immunoassay system. The experts in immunoassay systems should make every effort to find some specific and reliable quality indicators for irregular analytical errors in order to better detect and monitor erroneous immunoassay results due to specific or non-specific interferences.


Assuntos
Técnicas de Laboratório Clínico , Erros de Diagnóstico , Imunoensaio , Humanos , Controle de Qualidade
10.
J Clin Lab Anal ; 32(3)2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28643405

RESUMO

AIM OF THE STUDY: To reassess the imprecision and Limit of Quantitation, to evaluate the cross-reaction with dehydroepiandrosterone-sulfate (DHEAS), the accuracy toward liquid chromatography-mass spectrometry (LC-MS) and the reference interval of the Access Testosterone method, performed by DxI immunoassay platform (Beckman Coulter). MATERIAL AND METHODS: Imprecision was evaluated testing six pool samples assayed in 20 different run using two reagents lots. The cross-reaction with DHEAS was studied both by a displacement curve and by spiking DHEAS standard in two serum samples with known amount of testosterone. The comparison with LC-MS was evaluated by Passing-Bablock analysis in 21 routine serum samples and 19 control samples from an External Quality Assurance (EQA) scheme. The reference interval was verified by an indirect estimation on 2445 male and 2838 female outpatients. RESULTS: The imprecision study showed a coefficient of variation (CV) between 2.7% and 34.7% for serum pools from 16.3 and 0.27 nmol/L. The value of Limit of Quantitation at 20% CV was 0.53 nmol/L. The DHEAS showed a cross-reaction of 0.0074%. A comparison with LC-MS showed a trend toward a slight underestimation of immunoassay vs LC-MS (Passing-Bablock equations: DxI=-0.24+0.906 LCMS in serum samples and DxI=-0.299+0.981 LCMS in EQA samples). The verification of reference interval showed a 2.5th-97.5th percentile distribution of 6.6-24.3 nmol/L for male over 14 years and <0.5-2.78 nmol/L for female subjects, in accord with the reference intervals reported by the manufacturer. CONCLUSIONS: The Access Testosterone method could be considered an adequately reliable tool for the testosterone measurement.


Assuntos
Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Testosterona/sangue , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cromatografia Líquida/normas , Humanos , Imunoensaio/métodos , Imunoensaio/normas , Masculino , Espectrometria de Massas/normas , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
12.
Clin Chem Lab Med ; 55(11): 1722-1733, 2017 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-28245185

RESUMO

BACKGROUND: Systematic difference between thyroid-stimulating hormone (TSH) immunoassays may produce misleading interpretation when samples of the same patients are measured with different methods. The study aims were to evaluate whether systematic differences are present among TSH immunoassays, and whether it is possible to obtain a better harmonization among TSH methods using results obtained in external quality assessment (EQA) schemes. METHODS: Seven Italian clinical laboratories measured TSH in 745 serum samples of healthy subjects and patients with thyroid disorders. These samples were also re-measured by two reference laboratories of the study with the six TSH immunoassays most popular in Italy after 2 months of storage at -80 °C. Moreover, these data were compared to 53,823 TSH measurements, obtained by laboratories participant to 2012-2015 EQA annual cycles in 72 quality control samples (TSH concentrations from about 0.1 mIU/L to 18.0 mIU/L). TSH concentrations were recalibrated using a mathematical approach based on the principal component analysis (PCA). RESULTS: Systematic differences were found between the most popular commercially available TSH immunoassays. TSH concentrations measured by the clinical laboratories were very closely correlated to those measured with the same method by reference laboratories after 2 months of storage at -80 °C. After recalibration using the PCA approach the variation of TSH values significantly decreased from a median pre-calibration value of 13.53% (10.79%-16.53%) to 9.63% (6.90%-13.21%) after recalibration. CONCLUSIONS: Our data suggest that EQA schemes are useful to improve harmonization among TSH immunoassays and also to produce some mathematical formulas, which can be used by clinicians to better compare TSH values measured with different methods.


Assuntos
Imunoensaio/métodos , Tireotropina/sangue , Calibragem , Humanos , Imunoensaio/normas , Laboratórios/normas , Modelos Lineares , Análise de Componente Principal , Controle de Qualidade , Kit de Reagentes para Diagnóstico , Doenças da Glândula Tireoide/diagnóstico , Tireotropina/normas
15.
Scand J Clin Lab Invest ; 73(6): 480-4, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24015957

RESUMO

BACKGROUND: Sex hormone-binding globulin (SHBG) is the main transport protein of sex steroids. This study evaluated the analytical performance of the recently developed Access SHBG assay (Beckman Coulter) and compared it with other commercial methods for the determination of serum SHBG. Clinical validation was also performed. METHODS: Analytical performance including within-run and between-run imprecision was assessed for Access SHBG assay on the automated Beckman UniCel DxI800 analyzer. Linearity was assessed using five dilutions of the serum samples. For methods comparison, SHBG levels were determined also with Immulite 2000 analyzer (Siemens Healthcare) using clinical serum samples (n = 104). For clinical validation 135 specimens from healthy subjects, pregnant women, hypothyroid and hyperthyroid patients were analyzed. RESULTS: Total coefficients of variation were < 5.5%. Linearity test showed > 90% recovery for all samples and for all dilution rates. Comparison analysis (Bland-Altman difference analysis and Passing-Bablock regression) showed an acceptable agreement between selected methods. SHBG values measured by Access SHBG assay in different groups of subjects were in agreement with other clinical evidence. CONCLUSIONS: Automated Access SHBG assay appears to be a reliable and easy to perform assay, as necessary for application in routine diagnostics.


Assuntos
Globulina de Ligação a Hormônio Sexual/metabolismo , Adulto , Idoso , Automação Laboratorial , Análise Química do Sangue , Feminino , Humanos , Hipertireoidismo/sangue , Hipotireoidismo/sangue , Medições Luminescentes , Masculino , Pessoa de Meia-Idade , Pós-Menopausa , Gravidez , Pré-Menopausa , Valores de Referência , Adulto Jovem
16.
Int J Biol Markers ; 38(1): 61-71, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36855811

RESUMO

PURPOSE: The overuse of laboratory tests contributes to impair health systems effectiveness, tumor markers (TMs) being a paradigmatic example. In the present study we applied indicators of TMs appropriateness developed from administrative datasets to appraise regionwide overordering in the clinical practice. PATIENTS AND METHODS: TMs ordered to outpatients in the Veneto Region over 6 years were obtained from the eletronic Outpatients' Records of Diagnostic and Therapeutic Procedures. TMs orders were examined as aggregated data or stratified according to disease codes, gender, age, and requests per patient. TMs recommended only for specific malignancies were examined using epidemiological data obtained from Veneto Tumor Registry. RESULTS: A total of 5,821,251 TMs were ordered in 4,382,159 patients over 6 years. Overall, 3,252,389 (55.9%) TMs were ordered without appropriate disease codes (ranging from 77.0% for PSA to 17.5% for CA15.3). TM orders declined over 6 years (-13.4%), with a noticeable reduction of orders without appropriate disease codes (-21.3%). Orders decreased sharply from 2015 to 2016, after the enactment of a national Decree-Law aimed at improving appropriateness, and remained stable thereafter. However, the rate of inappropriate TMs requests still remained elevated (44.4%) in the last year of observation, with orders of TMs being much higher than expected on the basis of prevalence and incidence figures of specific malignancies. CONCLUSIONS: Indicators developed from administrative datasets were effective in assessing the overordering of TMs and the impact of interventions to improve appropriateness. The developed indicators could be considered for other diagnostic tests.


Assuntos
Biomarcadores Tumorais , Neoplasias , Humanos , Pacientes Ambulatoriais , Neoplasias/epidemiologia , Neoplasias/diagnóstico , Mucina-1 , Sistema de Registros
18.
Diagnostics (Basel) ; 12(2)2022 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-35204574

RESUMO

A WHO standard was prepared with the aim of harmonizing assays detecting antibodies against SARS-CoV-2, but the issue is currently being debated. We re-evaluated a previously studied set of cases (108 specimens of 48 patients and 60 specimens of 20 vaccinated subjects, collected after 14 days from the first dose and 14 days and 3 months after a second dose of the Comirnaty BNT162b2 vaccine), calculating the ratios between the results of two methods (SARS-CoV-2 IgG anti-RBD, SNIBE, and anti-SARS-CoV-2 QuantiVac ELISA IgG, Euroimmun). In the vaccinated subjects, the ratios of the results between methods according to the WHO standard were relatively dispersed, but the harmonization results were good. On the other hand, in patient samples, the variability between tests was very high, and the harmonization was unsatisfactory (median ratios between methods 2.23, 10th-90th percentile: 1.1-5.6). Interestingly, in patient samples, the harmonization depends on the time from the onset of symptoms and greatly improves after 6 months since the diagnosis. Forty patient specimens and thirty-one of the vaccinated subjects after the second dose were also evaluated with a third method (Access SARS-CoV-2 IgG (1st IS), Beckman Coulter), obtaining a similar trend. We can conclude that the actual effectiveness of harmonization between methods may vary depending on the scenario in which they will be used.

19.
Diagn Microbiol Infect Dis ; 99(4): 115297, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33388574

RESUMO

INTRODUCTION: The persistence of circulating antibodies to SARS-CoV-2 infection is not yet well known. We compare the results of 2 automated systems for the determination of IgG against SARS CoV-2 and assess the time-course of the IgG response. METHODS: IgG were measured in 103 specimens of 55 patients with COVID-19 (time from the symptoms' onset: 3-187 days) using the automated tests "Abbott SARS-COV-2 IgG" and "MAGLUMI 2019-nCoV IgG". RESULTS: The 2 methods had a concordance of 90.3%, but the quantitative correlation, although significant, showed dispersed results. All the specimens resulted positive after 17 days. However, the median concentrations of IgG rapidly increased up to 20 days and decreased for Maglumi IgG while Abbott IgG showed a constant trend up to 85 days, and then slowly declined. CONCLUSIONS: The titer of IgG against SARS-CoV-2 may significantly and rapidly decrease, but with a very different time-course depending on the method used for the determination.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/métodos , Imunoensaio/métodos , Imunoglobulina G/sangue , SARS-CoV-2/imunologia , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
20.
Diagnostics (Basel) ; 11(9)2021 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-34574052

RESUMO

The time course of antibodies against SARS-CoV-2 is not yet well elucidated, especially in people who underwent a vaccination campaign. In this study, we measured the antibodies anti-S1 and anti-RBD with two different methods, both in patients and in vaccinated subjects. One hundred and eight specimens from 48 patients with COVID-19 (time from the onset of symptoms from 3 to 368 days) and 60 specimens from 20 vaccinated subjects (collected after 14 days from the first dose, 14 days and 3 months after a second dose of Comirnaty) were evaluated. We used an ELISA method that measured IgG against anti-Spike 1, and a chemiluminescence immunoassay that measured IgG anti-RBD. In the patients, the antibodies concentrations tended to decline after a few months, with both the methods, but they persisted relatively high up to nearly a year after the symptoms. In the vaccinated subjects, the antibodies were already detectable after the first dose, but after the booster, they showed a significant increase. However, the decrease was rapid, given that 3 months after the second vaccination, they were reduced to less than a quarter. The conversion of the results into BAU units improves the relationship between the two methods. However, in the vaccinated subjects, there was no evidence of proportional error after the conversion, while in the patients, the difference between the two methods remained significant.