Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Prehosp Emerg Care ; 27(2): 263-268, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35007470

RESUMO

Objectives: Up to 40% of children who receive a medication from emergency medical services (EMS) are subject to a dosing error. One of the reasons for this is difficulties adjusting dosages for weight. Converting weights from pounds to kilograms complicates this further. This is the rationale for the National EMS Quality Alliance measure Pediatrics-03b, which measures the proportion of children with a weight documented in kilograms. However, there is little evidence that this practice is associated with lower rates of dosing errors. Therefore, our objective was to determine whether EMS documentation of weight in kilograms was associated with a lower rate of pediatric medication dosing errors.Methods: We conducted a retrospective cross-sectional study of children 0-14 y/o in the 2016-17 electronic Maryland Emergency Medical Services Data System that received a weight-based medication. Using validated age-based formulas, we assigned a weight to patients without one documented. Doses were classified as errors and severe errors if they deviated from the state protocol by >20% or >50%, respectively. We compared the dosage errors in the two groups and completed secondary analyses for specific medications and age groups.Results: We identified 3,618 cases of medication administration, 53% of which had a documented weight. Patients with a documented weight had a significantly lower overall dose error rate than those without (22 vs. 26%, p<.05). A sensitivity analysis in which we assigned a weight to those patients with a weight recorded did not significantly change this result. Sub-analyses by individual medication showed that only epinephrine (34 vs. 56%, p<.05) and fentanyl (10 vs. 31%, p <.05) had significantly lower dosing error rates for patients with a documented weight. Infants were the only age group where documenting a weight was associated with a lower dosing error rate (33 vs. 53% p<.05).Conclusion: Our findings suggest that documenting a weight in kilograms is associated with a small but significantly lower rate of pediatric dosing errors by EMS. Documenting a weight in kilograms appears particularly important for specific medications and patient age groups. Additional strategies (including age-based standardized dosing) may be needed to further reduce pediatric dosing errors by EMS.


Assuntos
Serviços Médicos de Emergência , Lactente , Criança , Humanos , Estudos Retrospectivos , Estudos Transversais , Erros de Medicação/prevenção & controle , Epinefrina
2.
Pediatr Emerg Care ; 31(2): 83-7, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25654673

RESUMO

INTRODUCTION: Handoff communication is an important contributor to safety and quality in the emergency department (ED). Breakdowns in this process may lead to unsafe conditions or adverse events. The purpose of this study was to test the hypothesis that the quality of patient handoffs in the pediatric ED would improve after implementation of a structured handoff method. METHODS: In this prospective, observational study, we evaluated the implementation of a structured handoff tool, SOUND, which we developed to standardize the format of handoffs. The tool contains 5 components as follows: Synthesis, Objective Data, Upcoming Tasks, Nursing Input, and Double Check. SOUND was implemented through an online module and provider education. Handoffs were observed before and after implementation of SOUND. Statistical process control was used to measure the effects of the intervention. A successful handoff was defined as one in which 4 of the 5 components were included. As a balancing measure, we calculated mean time per handoff. RESULTS: We observed 638 handoffs. The implementation of SOUND significantly increased the percentage of successful handoffs. Statistical process control demonstrated continued improvement over time. This improvement was associated with a modest increase in the mean time per patient discussed (52.9 vs 73.0 seconds, P < 0.01). CONCLUSIONS: It is feasible to standardize patient handoffs in the pediatric ED. The implementation of SOUND improved completeness of handoffs with only a modest increase in the mean time spent discussing each patient. Future study is required to determine if SOUND will prove effective in other ED settings.


Assuntos
Serviço Hospitalar de Emergência , Transferência da Responsabilidade pelo Paciente/normas , Melhoria de Qualidade , Criança , Humanos , Estudos Prospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa