Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Bioconjug Chem ; 35(7): 1044-1052, 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-38875443

RESUMO

Subcutaneous (SC) injection of protein-based therapeutics is a convenient and clinically established drug delivery method. However, progress is needed to increase the bioavailability. Transport of low molecular weight (Mw) biotherapeutics such as insulin and small molecule contrast agents such as lipiodol has been studied using X-ray computed tomography (CT). This analysis, however, does not translate to the investigation of higher Mw therapeutics, such as monoclonal antibodies (mAbs), due to differences in molecular and formulation properties. In this study, an iodinated fluorescein analog rose bengal (RB) was used as a radiopaque and fluorescent label to track the distribution of bovine serum albumin (BSA) compared against unconjugated RB and sodium iodide (NaI) via CT and confocal microscopy following injection into ex vivo porcine SC tissue. Importantly, the high concentration BSA-RB exhibited viscosities more like that of viscous biologics than the small molecule contrast agents, suggesting that the labeled protein may serve as a more suitable formulation for the investigation of injection plumes. Three-dimensional (3D) renderings of the injection plumes showed that the BSA-RB distribution was markedly different from unconjugated RB and NaI, indicating the need for direct visualization of large protein therapeutics using conjugated tags rather than using small molecule tracers. Whereas this proof-of-concept study shows the novel use of RB as a label for tracking BSA distribution, our experimental approach may be applied to high Mw biologics, including mAbs. These studies could provide crucial information about diffusion in SC tissue and the influence of injection parameters on distribution, transport, and downstream bioavailability.


Assuntos
Rosa Bengala , Soroalbumina Bovina , Tomografia Computadorizada por Raios X , Soroalbumina Bovina/química , Soroalbumina Bovina/metabolismo , Animais , Rosa Bengala/química , Bovinos , Tomografia Computadorizada por Raios X/métodos , Microscopia de Fluorescência/métodos , Transporte Proteico , Tela Subcutânea/diagnóstico por imagem , Tela Subcutânea/metabolismo , Suínos , Corantes Fluorescentes/química
2.
Pharm Res ; 38(2): 257-275, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33619639

RESUMO

PURPOSE: Interface motion and hydrodynamic shear of the liquid slosh during the insertion of syringes upon autoinjector activation may damage the protein drug molecules. Experimentally validated computational fluid dynamics simulations are used in this study to investigate the interfacial motion and hydrodynamic shear due to acceleration and deceleration of syringes. The goal is to explore the role of fluid viscosity, air gap size, syringe acceleration, syringe tilt angle, liquid-wall contact angle, surface tension and fill volume on the interface dynamics caused by autoinjector activation. METHODS: A simplified autoinjector platform submerged in water is built to record the syringe and liquid motion without obstruction of view. The syringe kinematics is imported to the simulations based on OpenFOAM InterIsoFoam solver, which is used to study the effects of various physical parameters. RESULTS: The simulations agree with experiments on the air-liquid interface profile and interface area. The interfacial area and the volume of fluid subject to high strain rate decrease with the solution viscosity, increase with the air gap height, syringe velocity, tilt angle and syringe wall hydrophobicity, and hardly change with the surface tension and liquid column height. The hydrodynamic shear mainly occurs near the syringe wall and entrained bubbles. CONCLUSION: For a given dose of drug solution, the syringe with smaller radius and larger length will generate less liquid slosh. Reducing the air volume and syringe wall hydrophobicity are also helpful to reduce interface area and effective shear. The interface motion is reduced when the syringe axis is aligned with the gravitational direction.


Assuntos
Desenho de Equipamento , Modelos Químicos , Soluções/química , Seringas , Química Farmacêutica , Simulação por Computador , Hidrodinâmica , Injeções Subcutâneas/instrumentação , Soluções/administração & dosagem , Tensão Superficial , Viscosidade
3.
J Biomech Eng ; 139(12)2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28857116

RESUMO

Computational fluid dynamics (CFD) is a promising tool to aid in clinical diagnoses of cardiovascular diseases. However, it uses assumptions that simplify the complexities of the real cardiovascular flow. Due to high-stakes in the clinical setting, it is critical to calculate the effect of these assumptions in the CFD simulation results. However, existing CFD validation approaches do not quantify error in the simulation results due to the CFD solver's modeling assumptions. Instead, they directly compare CFD simulation results against validation data. Thus, to quantify the accuracy of a CFD solver, we developed a validation methodology that calculates the CFD model error (arising from modeling assumptions). Our methodology identifies independent error sources in CFD and validation experiments, and calculates the model error by parsing out other sources of error inherent in simulation and experiments. To demonstrate the method, we simulated the flow field of a patient-specific intracranial aneurysm (IA) in the commercial CFD software star-ccm+. Particle image velocimetry (PIV) provided validation datasets for the flow field on two orthogonal planes. The average model error in the star-ccm+ solver was 5.63 ± 5.49% along the intersecting validation line of the orthogonal planes. Furthermore, we demonstrated that our validation method is superior to existing validation approaches by applying three representative existing validation techniques to our CFD and experimental dataset, and comparing the validation results. Our validation methodology offers a streamlined workflow to extract the "true" accuracy of a CFD solver.


Assuntos
Hidrodinâmica , Aneurisma Intracraniano/fisiopatologia , Modelagem Computacional Específica para o Paciente , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Imagens de Fantasmas
4.
Int J Pharm ; 627: 122210, 2022 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-36122618

RESUMO

Understanding the interface motion and hydrodynamic shear induced by the liquid sloshing during the insertion stage of an autoinjector can help improve drug product administration. We perform experiments to investigate the interfacial motion and hydrodynamic shear due to the acceleration and deceleration of syringes. The goal is to explore the role of fluid properties, air gap size, and syringe acceleration on the interface dynamics caused by autoinjector activation. We used a simplified autoinjector platform to record the syringe and liquid motion without any view obstruction. Water and silicone oil with the same viscosity are used as the model fluids. Particle Image Velocimetry (PIV) is employed to measure the velocity field. Simultaneous shadowgraph visualization captures the air entrainment. Our in-house PIV and image processing algorithms are used to quantify the hydrodynamic stress and interfacial area to investigate the effects of various autoinjector design parameters and fluid types on liquid sloshing. The results indicate that reducing the air gap volume and syringe acceleration/deceleration mitigate the interface area and effective shear. Moreover, the interfacial area and induced hydrodynamic stress decrease with the Fr=U/aD, where U is the interface velocity, a is the maximum syringe acceleration, and D is the syringe diameter.


Assuntos
Hidrodinâmica , Seringas , Óleos de Silicone/química , Reologia , Água
5.
Sci Rep ; 11(1): 1884, 2021 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-33479423

RESUMO

Mosquitoes are vectors for some of the most devastating diseases on the planet. Given the centrality of acoustic sensing in the precopulatory behavior of these vectors, the use of an exogenous acoustic stimulus offers the potential of interfering with the courtship behavior of these insects. Previous research on the acoustotactic response of mosquitoes has been conducted on tethered preparations using low-intensity sound stimuli. To quantify differences in acoustotactic responses between mosquitos of distinct sex and species, we examined the effects of incidental sound stimuli on the flight behavior of free-flying male vs. female Aedes aegypti and Anopheles gambiae mosquitoes. The key variables were sound frequency (100-1000 Hz) and intensity (67-103 dB, measured at 12.5 cm from the source), and the acoustotactic response was measured in terms of the relative increase in flight speed in response to the stimulus. The data show, for the first time, significant sex- and species-specific differences in acoustotactic responses. A. aegypti exhibited a greater response to sound stimulus compared to An. gambiae, and the response also extended over a larger range of frequencies. Furthermore, the males of both species displayed a greater acoustotactic response than females, with An. gambiae females exhibiting minimal response to sound.


Assuntos
Aedes/fisiologia , Anopheles/fisiologia , Voo Animal/fisiologia , Mosquitos Vetores/fisiologia , Comportamento Sexual Animal/fisiologia , Som , Estimulação Acústica , Animais , Feminino , Masculino , Especificidade da Espécie
6.
Int J Pharm ; 608: 121062, 2021 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-34506926

RESUMO

The collapse of cavitation bubbles induced by abrupt acceleration of the syringe in an autoinjector device can lead to protein aggregation. The details of bubble dynamics are investigated using an axisymmetric, three-dimensional simulation with passive tracers to illustrate the transport of protein molecules. When a bubble near the syringe wall collapses, protein molecules are concentrated in the re-entrant jet, pushed towards the syringe wall, and then spread across the wall, potentially leading to protein adsorption on the syringe wall and aggregation. This phenomenon is more prominent for bubbles positioned closer to the bottom wall, growing to a larger maximum radius. The bubble's maximum radius decreases with the bubble's distance from the syringe wall and air gap pressure, and increases with an increase in liquid column height and nucleus size. The strain rate induced by the bubble collapse is not large enough to unfold the proteins. When the re-entrant jet impacts the bubble surface or syringe wall, the bubble breaks up, generating smaller bubbles with high surface concentration of protein molecules, potentially inducing aggregation in the bulk. The bubble dynamics are influenced by dimensionless distance of the nucleus from the wall, normalized by maximum bubble radius (γ). The re-entrant jet velocity increases with γ, while the maximum liquid pressure, typically 100∼1000 bar, first decreases and then increases with γ. For a cloud of cavitation bubbles, i.e., closely clustered bubbles, coalescence of bubbles can occur, leading to a higher peak pressure at collapse.


Assuntos
Preparações Farmacêuticas , Simulação por Computador , Pressão
7.
Curr Med Res Opin ; 36(8): 1343-1354, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32544355

RESUMO

Objective: Autoinjectors are a convenient and efficient way to self-administer subcutaneous injections of biopharmaceuticals. Differences in device mechanical design can affect the autoinjector functionality and performance. This study investigates the performance differences of two single-spring-actuated autoinjectors.Methods: We compare the performance between Emgality (120 mg/mL) and Aimovig (140 mg/mL) autoinjector devices from an engineering point of view at two test conditions: room (25 C[Formula: see text]) and storage (5 C[Formula: see text]) temperatures. We employ a novel experimental procedure to simultaneously acquire the force and acoustic signals during operation, and high-speed imaging during the needle insertion and drug injection.Results: We perform 18 quantitative comparisons between Emgality and Aimovig, and we observe that 14 of these have statistically significant differences. For both test conditions, Emgality requires an 8 N activation force while Aimovig requires 14 N activation force, and the needle of Emgality has an insertion depth of 5 mm while Aimovig has an insertion depth of 7 mm. The injection speeds are significantly affected by temperature. Emgality has an injection speed of 0.40 mL/s and 0.28 mL/s at room and storage temperature condition, respectively; while Aimovig has an injection speed of 0.24 mL/s and 0.16 mL/s at those conditions. Lastly, confirmation "click" sound of Emgality occurs 0.75-1.53 s after dose completion, while in Aimovig, the confirmation "click" sound occurs 0.26-0.46 s before dose completion.Conclusions: This study revealed performance differences between Emgality and Aimovig autoinjector devices, despite the fact that the delivery principle of these single-spring-actuated autoinjectors are the same. These differences may result in different risk of intramuscular injection and premature device removal, both of which need to be further verified in clinical trials.


Assuntos
Anticorpos Monoclonais Humanizados/administração & dosagem , Antagonistas do Receptor do Peptídeo Relacionado ao Gene de Calcitonina/administração & dosagem , Injeções Subcutâneas/instrumentação , Humanos , Autoadministração
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa