Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Biomed Res Int ; 2020: 9879463, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32185231

RESUMO

BACKGROUND: The present meta-analysis was conducted to confirm whether carotid intima-media thickness (IMT) could serve as an accurate diagnostic method for coronary artery disease (CAD). METHODS: Databases of PubMed, Google Scholar, and Embase were searched for potential articles. The articles were selected according to inclusion criteria. Pooled sensitivity and specificity with corresponding 95% confidence interval (CI) were used to confirm the diagnostic role of IMT for CAD. I 2 and P value were used to assess the existence of heterogeneity. I 2 and P value were used to assess the existence of heterogeneity. RESULTS: 22 eligible articles were selected in the present meta-analysis. Pooled sensitivity and specificity of IMT for diagnosing CAD were 0.68 (0.57-0.77) and 0.70 (0.64-0.75), respectively. The corresponding AUC was 0.74 (0.70-0.78). Subgroup analyses based on cutoff value of IMT were performed. A cutoff value of 1 mm was demonstrated to be much more accurate diagnostic criteria for CAD (sensitivity: 0.66; specificity: 0.79; AUC: 0.80). Sensitivity analysis indicated that the pooled results were robust. Deek's funnel plot indicated no significant publication bias (P value were used to assess the existence of heterogeneity. CONCLUSION: Carotid IMT may serve as an accurate diagnostic tool. A cutoff value of 1 mm seems to provide much more accurate diagnostic results for CAD.


Assuntos
Espessura Intima-Media Carotídea , Doença da Artéria Coronariana/diagnóstico , Bases de Dados Factuais , Humanos , Sensibilidade e Especificidade
2.
Biomed Res Int ; 2017: 2123918, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29376068

RESUMO

OBJECTIVE: The opinions about the application of pulse oximetry in diagnosis of congenital heart disease (CHD) were debatable. We performed this meta-analysis to confirm the diagnostic role of pulse oximetry screening for CHD. METHODS: Relevant articles were searched in the databases of Pubmed, Embase, Google Scholar, and Chinese National Knowledge Infrastructure (CNKI) up to April 2017. Data was processed in the MetaDiSc 1.4 software. Pooled sensitivity and specificity with 95% confidence interval (95% CI) were calculated to explain the diagnostic role of pulse oximetry screening for CHD. I2⩾50% or p < 0.05 indicated significant heterogeneity. Area under curve (AUC) of summary receiver operating characteristics (SROC) was calculated to assess its diagnostic accuracy. The robustness of overall results was evaluated by sensitivity analysis. Publication bias was evaluated by Deek's funnel plot. RESULTS: 22 eligible articles were selected. Pooled sensitivity and specificity were 0.69 (0.67-0.72) and 0.99 (0.99-0.99), respectively. The corresponding AUC was 0.9407, suggesting high diagnostic accuracy of pulse oximetry screening for CHD. Sensitivity analysis demonstrated that the pooled results were robust. Deek's funnel plot seemed to be symmetrical. CONCLUSIONS: Pulse oximetry screening could be used to diagnose CHD. It shows high diagnosis specificity and accuracy.


Assuntos
Cardiopatias Congênitas/diagnóstico , Oximetria/métodos , Área Sob a Curva , Humanos , Curva ROC , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa