Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Transpl Int ; 37: 12686, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38911062

RESUMO

Optimizing graft preservation is key for ex-situ split grafts in pediatric liver transplantation (PSLT). Hypothermic Oxygenated Perfusion (HOPE) improves ischemia-reperfusion injury (IRI) and post-operative outcomes in adult LT. This study compares the use of HOPE in ex-situ partial grafts to static cold storage ex-situ partial grafts (SCS-Split) and to the gold standard living donor liver transplantation (LDLT). All consecutive HOPE-Split, SCS-Split and LDLT performed between 2018-2023 for pediatric recipients were included. Post-reperfusion syndrome (PRS, drop ≥30% in systolic arterial pressure) and reperfusion biopsies served as early indicators of IRI. We included 47 pediatric recipients (15 HOPE-Split, 17 SCS-Split, and 15 LDLT). In comparison to SCS-Split, HOPE-Split had a significantly shorter cold ischemia time (CIT) (470min vs. 538 min; p =0.02), lower PRS rates (13.3% vs. 47.1%; p = 0.04) and a lower IRI score (3 vs. 4; p = 0.03). The overall IRI score (3 vs. 3; p = 0.28) and PRS (13.3% vs. 13.3%; p = 1) after HOPE-Split were comparable to LDLT, despite a longer CIT (470 min vs. 117 min; p < 0.001). Surgical complications, one-year graft, and recipient survival did not differ among the groups. In conclusion, HOPE-Split mitigates early IRI in pediatric recipients in comparison to SCS-Split, approaching the gold standard of LDLT.


Assuntos
Transplante de Fígado , Doadores Vivos , Preservação de Órgãos , Perfusão , Traumatismo por Reperfusão , Humanos , Transplante de Fígado/métodos , Transplante de Fígado/efeitos adversos , Traumatismo por Reperfusão/prevenção & controle , Traumatismo por Reperfusão/etiologia , Masculino , Feminino , Criança , Pré-Escolar , Preservação de Órgãos/métodos , Perfusão/métodos , Adolescente , Lactente , Isquemia Fria , Sobrevivência de Enxerto , Estudos Retrospectivos , Fígado/irrigação sanguínea
2.
Surg Endosc ; 38(7): 3602-3608, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38769183

RESUMO

BACKGROUND: Although esophageal achalasia has been historically treated by Heller myotomy, endoscopic esophageal dilatations are nowadays often the first-line treatment in children. The aim was to assess whether performing an endoscopic dilatation before a Heller myotomy is associated with higher risks of esophageal perforation in children. METHODS: A retrospective multicentric study was performed, including children that underwent a Heller myotomy (2000-2022, 10 centers). Two groups were compared based on the history of previous dilatation before myotomy. Outcomes esophageal perforation (intra-operative or secondary) and post-operative complications requiring surgery (Clavien-Dindo III). Statistics Comparisons using contingency tables or Kruskal-Wallis when appropriate. Statistical significance: p-value < 0.05. RESULTS: A Heller myotomy was performed in 77 children (median age: 11.8 years), with prior endoscopic dilatation in 53% (n = 41). A laparoscopic approach was used in 90%, with associated fundoplication in 95%. Esophageal perforation occurred in 19% of children (n = 15), including 12 patients with intra-operative mucosal tear and 3 with post-operative complications related to an unnoticed esophageal perforation. Previous endoscopic dilatation did not increase the risk of esophageal perforation (22% vs 17%, OR: 1.4, 95%CI: 0.43-4.69). Post-operative complications occurred in 8% (n = 6), with similar rates regardless of prior endoscopic dilatation. Intra-operative mucosal tear was the only risk factor for post-operative complications, increasing the risk of complications from 5 to 25% (OR: 6.89, 95%CI: 1.38-31.87). CONCLUSIONS: Prior endoscopic dilatations did not increase the risk of esophageal perforation or postoperative complications of Heller myotomy in this cohort of children with achalasia. Mucosal tear was identified as a risk factor for post-operative complications.


Assuntos
Dilatação , Acalasia Esofágica , Perfuração Esofágica , Esofagoscopia , Miotomia de Heller , Complicações Pós-Operatórias , Humanos , Criança , Estudos Retrospectivos , Feminino , Masculino , Miotomia de Heller/efeitos adversos , Miotomia de Heller/métodos , Acalasia Esofágica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Perfuração Esofágica/etiologia , Perfuração Esofágica/epidemiologia , Fatores de Risco , Adolescente , Dilatação/métodos , Pré-Escolar , Esofagoscopia/métodos , Esofagoscopia/efeitos adversos
3.
Pediatr Emerg Care ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38743405

RESUMO

BACKGROUND: Isolated fallopian tube torsion (IFTT) is very rare gynecological emergency in pediatric population. Our objective is to assess treatment options and discuss outcome of a cohort of IFTT with a focus on the association between IFTT and hydrosalpinx (HSX). METHODS: A retrospective review was conducted. Pediatric patients with IFTT operated in the same center were included. RESULTS: Seventeen girls (aged: 11-16 years) were managed for acute abdominal pain between 2008 and 2018, with intraoperative diagnosis of IFTT. All patients underwent laparoscopic exploration, with laparoscopically fallopian tube detorsion in all patients. Based on the association of IFTT with HSX after fallopian tube detorsion, patients were divided into 2 groups: group 1 (IFTT without HSX; 12 girls) and group 2 (IFTT with HSX; 5 girls). During the same surgery, complementary surgical procedures were done. In group 1: salpingectomies (4), partial salpingectomies (2) and cystectomies (6) were done. In group 2: salpingectomy (1), salpingotomy (1), and cyst ablation (1). The treatment was called conservative when the tube was preserved.Follow-up was uneventful in group 1. In group 2, for all patients with initial fallopian tube preservation, further surgical procedures were necessary (1-4 surgeries/patient), and, finally, another 3 patients required salpingectomy. CONCLUSIONS: Conservative treatment with tube preservation of IFTT without HSX appeared to be beneficial compared to those with HSX, with no recurrence of torsion or symptoms during the follow-up. However, the same conservative treatment was not sufficiently effective for IFTT with HSX and required further procedures due to recurrence of torsion. LEVEL OF EVIDENCE: IV.

4.
Fetal Diagn Ther ; 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38934150

RESUMO

INTRODUCTION: Congenital microgastria (CM) is a rare condition due to early interruption of stomach development between the 4th and 8th week of gestation, leading to a small midline tubular stomach. Prenatal diagnosis of CM is a challenge with important implications. This study explores the value of biochemical amniotic fluid (AF) analysis and fetal magnetic resonance imaging (MRI) for the prenatal diagnosis of CM in case of non visible stomach on fetal ultrasound. CASE PRESENTATION: Four cases of CM were retrospectively investigated in terms of fetal ultrasound, MRI findings and biochemical AF analyses. The patients were referred to the Prenatal Diagnosis Unit of the Hôpital Femme Mère Enfant (Lyon, France) at a mean age of 21 weeks of gestation for absent or small fetal stomach on ultrasound with a suspected diagnosis of esophageal atresia. Ultrasound examination confirmed that the stomach was absent in two of the four fetuses and small in the other two. This feature was associated with a congenital heart defect in two cases and a terminal transverse limb defect in one case. Standard genetic workup (CGH array) results were normal. Biochemical AF analysis, including the esophageal atresia (EA) index were not suggestive of EA. Fetal MRI showed a small midline tubular stomach, associated with a dilated esophagus, highly suggestive of CM. CONCLUSION: If the fetal stomach is absent on ultrasound, CM should be considered if the AF volume is normal, especially during the third trimester, and if the EA index is not suggestive of gastrointestinal obstruction. In these cases, the diagnosis can be confirmed by fetal MRI, through observation of a small midline tubular stomach associated with a dilated esophagus.

5.
Pediatr Transplant ; 27(4): e14510, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36919397

RESUMO

BACKGROUND: Graft-recipient size matching is a major challenge in pediatric liver transplantation, especially for adolescent recipients. Indeed, adolescents have the lowest transplantation rate among pediatric recipients, despite prioritization policies and the use of split grafts. In case of an important graft-recipient size mismatch, ex situ graft reduction with right posterior sectionectomy (RPS) may optimize the available donor pool to benefit adolescent recipients. METHODS: We present three cases of liver graft reduction with ex situ RPS for adolescent recipients. The surgical strategy was guided by GRWR (graft/recipient weight ratio), GW/RAP (right anteroposterior distance ratio), and CT-scan volumetric and anthropometric evaluation. RESULTS: Recipients were 12, 13, and 14-year-old and weighed 32, 47, and 35 kg, respectively. All liver grafts were procured from brain-dead donors with a donor/recipient weight ratio >1.5. RPS was performed ex situ, removing 20% of the total liver volume leading to a decrease of the GRWR <4% and the GW/RAP <100 g/cm in each case. All three reduced grafts were successfully transplanted with a static cold storage time ranging from 390 to 510 min without the need for delayed abdominal closure. We did not observe any primary non-function, vascular complication, or delayed graft function with a median follow-up of 6 months. One biliary anastomotic stenosis occurred which required surgical treatment. CONCLUSION: Ex situ liver graft reduction with RPS allowed for successful transplantation in case of anthropometric graft-recipient size mismatch in adolescent liver transplant candidates. Although the use of split grafts remains the gold standard, RPS should be acknowledged as a way to optimize the donor pool, especially for adolescent recipients.


Assuntos
Colestase , Transplante de Fígado , Humanos , Adolescente , Criança , Fígado/cirurgia , Doadores de Tecidos , Hepatectomia , Colestase/cirurgia , Doadores Vivos , Sobrevivência de Enxerto , Resultado do Tratamento
6.
Eur Heart J ; 43(12): 1234-1247, 2022 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-35134898

RESUMO

AIMS: Mapping data of human ventricular fibrillation (VF) are limited. We performed detailed mapping of the activities underlying the onset of VF and targeted ablation in patients with structural cardiac abnormalities. METHODS AND RESULTS: We evaluated 54 patients (50 ± 16 years) with VF in the setting of ischaemic (n = 15), hypertrophic (n = 8) or dilated cardiomyopathy (n = 12), or Brugada syndrome (n = 19). Ventricular fibrillation was mapped using body-surface mapping to identify driver (reentrant and focal) areas and invasive Purkinje mapping. Purkinje drivers were defined as Purkinje activities faster than the local ventricular rate. Structural substrate was delineated by electrogram criteria and by imaging. Catheter ablation was performed in 41 patients with recurrent VF. Sixty-one episodes of spontaneous (n = 10) or induced (n = 51) VF were mapped. Ventricular fibrillation was organized for the initial 5.0 ± 3.4 s, exhibiting large wavefronts with similar cycle lengths (CLs) across both ventricles (197 ± 23 vs. 196 ± 22 ms, P = 0.9). Most drivers (81%) originated from areas associated with the structural substrate. The Purkinje system was implicated as a trigger or driver in 43% of patients with cardiomyopathy. The transition to disorganized VF was associated with the acceleration of initial reentrant activities (CL shortening from 187 ± 17 to 175 ± 20 ms, P < 0.001), then spatial dissemination of drivers. Purkinje and substrate ablation resulted in the reduction of VF recurrences from a pre-procedural median of seven episodes [interquartile range (IQR) 4-16] to 0 episode (IQR 0-2) (P < 0.001) at 56 ± 30 months. CONCLUSIONS: The onset of human VF is sustained by activities originating from Purkinje and structural substrate, before spreading throughout the ventricles to establish disorganized VF. Targeted ablation results in effective reduction of VF burden. KEY QUESTION: The initial phase of human ventricular fibrillation (VF) is critical as it involves the primary activities leading to sustained VF and arrhythmic sudden death. The origin of such activities is unknown. KEY FINDING: Body-surface mapping shows that most drivers (≈80%) during the initial VF phase originate from electrophysiologically defined structural substrates. Repetitive Purkinje activities can be elicited by programmed stimulation and are implicated as drivers in 37% of cardiomyopathy patients. TAKE-HOME MESSAGE: The onset of human VF is mostly associated with activities from the Purkinje network and structural substrate, before spreading throughout the ventricles to establish sustained VF. Targeted ablation reduces or eliminates VF recurrence.


Assuntos
Síndrome de Brugada , Ablação por Cateter , Mapeamento Potencial de Superfície Corporal , Ablação por Cateter/métodos , Eletrocardiografia , Ventrículos do Coração , Humanos , Fibrilação Ventricular
7.
Sensors (Basel) ; 23(5)2023 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-36904759

RESUMO

Smartwatches that support the recording of a single-lead electrocardiogram (ECG) are increasingly being used beyond the wrist, by placement on the ankle and on the chest. However, the reliability of frontal and precordial ECGs other than lead I is unknown. This clinical validation study assessed the reliability of an Apple Watch (AW) to obtain conventional frontal and precordial leads as compared to standard 12-lead ECGs in both subjects without known cardiac anomalies and patients with underlying heart disease. In 200 subjects (67% with ECG anomalies), a standard 12-lead ECG was performed, followed by AW recordings of the standard Einthoven leads (leads I, II, and III) and precordial leads V1, V3, and V6. Seven parameters (P, QRS, ST, and T-wave amplitudes, PR, QRS, and QT intervals) were compared through a Bland-Altman analysis, including the bias, absolute offset, and 95% limits of agreement. AW-ECGs recorded on the wrist but also beyond the wrist had similar durations and amplitudes compared to standard 12-lead ECGs. Significantly greater amplitudes were measured by the AW for R-waves in precordial leads V1, V3, and V6 (+0.094 mV, +0.149 mV, +0.129 mV, respectively, all p < 0.001), indicating a positive bias for the AW. AW can be used to record frontal, and precordial ECG leads, paving the way for broader clinical applications.


Assuntos
Eletrocardiografia , Cardiopatias , Humanos , Reprodutibilidade dos Testes , Arritmias Cardíacas , Tórax
8.
Liver Transpl ; 28(10): 1576-1587, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35582790

RESUMO

Partial liver grafts from ex situ splitting are considered marginal due to prolonged static cold storage. The use of ex situ hypothermic oxygenated perfusion (HOPE) may offer a strategy to improve preservation of ex situ split grafts. In this single-center pilot study, we prospectively performed ex situ liver splitting during HOPE (HOPE-Split) for adult and pediatric partial grafts over a 1-year period (November 1, 2020 to December 1, 2021). The primary safety endpoint was based on the number of liver graft-related adverse events (LGRAEs) per recipient, including primary nonfunction, biliary complications, hepatic vascular complications, and early relaparotomies and was compared with consecutive single-center standard ex situ split transplantations (Static-Split) performed from 2018 to 2020. Secondary endpoints included preservation characteristics and early outcomes. Sixteen consecutive HOPE-Split liver transplantations (8 HOPE-Split procedures) were included and compared with 24 Static-Splits. All HOPE-Split grafts were successfully transplanted, and no graft loss nor recipient death was encountered during the median follow-up of 7.5 months (interquartile range, 5.5-12.5). Mean LGRAE per recipient was similar in both groups (0.31 ± 0.60 vs. 0.46 ± 0.83; p = 0.78) and split duration was not significantly increased for HOPE-Split (216 vs. 180 min; p = 0.45). HOPE-Split grafts underwent perfusion for a median of 125 min, which significantly shortened static cold storage (472 vs. 544 min; p = 0.001), whereas it prolonged total ex vivo preservation (595 vs. 544 min; p = 0.007) and reduced neutrophil infiltration on reperfusion biopsies (p = 0.04) compared with Static-Split. This clinical pilot study presents first feasibility and safety data for transplantation of partial liver grafts undergoing ex situ split during HOPE and suggests improved preservation compared with static ex situ splitting. These preliminary results will allow to set up large-scale trials on the use of machine perfusion in pediatric and split-liver transplantation.


Assuntos
Transplante de Fígado , Adulto , Criança , Sobrevivência de Enxerto , Humanos , Fígado/cirurgia , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Preservação de Órgãos/efeitos adversos , Preservação de Órgãos/métodos , Perfusão/efeitos adversos , Perfusão/métodos , Projetos Piloto
9.
Pediatr Transplant ; 26(5): e14284, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35437884

RESUMO

BACKGROUND: Ex vivo split liver transplantation in pediatric recipients has shown inferior results compared with whole grafts. One factor among others contributing to split grafts being considered as marginal is the prolonged static cold storage time related to ex vivo liver splitting. End ischemic hypothermic oxygenated perfusion is a validated strategy to improve outcomes of marginal whole grafts and may thus also benefit split liver grafts. METHOD: We present the first case of full left/full right split procedure performed during hypothermic oxygenated perfusion. RESULTS: We present a standardized surgical two-step approach where parenchymal transection was performed during end ischemic hypothermic oxygenated perfusion via the portal vein to shorten static cold storage duration. Both split grafts were successfully transplanted in a 4-year-old pediatric and a 38-year-old adult recipient. Despite high-risk procedure (retransplantation), extended donor criteria including a prolonged cardiac arrest and high donor risk index (2,25), both grafts showed early recovery of hepatic function and low serum transaminase release. At 6 months, both recipients were alive with a normal liver biology and a functioning graft. CONCLUSION: Although challenging, full left/full right liver split procedure during end ischemic hypothermic oxygenated perfusion can be successfully performed and is a promising strategy to improve post-transplant outcomes.


Assuntos
Transplante de Fígado , Preservação de Órgãos , Adulto , Criança , Pré-Escolar , Sobrevivência de Enxerto , Humanos , Fígado/irrigação sanguínea , Fígado/cirurgia , Transplante de Fígado/métodos , Preservação de Órgãos/métodos , Perfusão/métodos , Doadores de Tecidos
10.
Ann Noninvasive Electrocardiol ; 27(6): e12994, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35986562

RESUMO

BACKGROUND: The T wave of the electrocardiogram (ECG) reflects ventricular repolarization. Repolarization heterogeneity is associated with reentrant arrhythmias. Several T-wave markers (including QT interval) have been associated with ventricular arrhythmias, but studies linking such markers to underlying local repolarization time (RT) inhomogeneities are lacking. We aimed to investigate the relation of several T-wave markers to controlled drug-induced regional RT gradients in intact pig hearts. METHODS: Repolarization time gradients were created by regional infusion of dofetilide and pinacidil in four atrially paced porcine Langendorff-perfused hearts placed inside a torso tank. From the 12-lead ECG on the torso tank, the mean, maximum, and dispersion (max-min) of QTtime , JTtime , Tpeak-end , Twidth , TQratio , dV/dtmax , Tarea , Tamp , and T-upslope duration were determined, as well as upslope end difference between leads V1 and V6 . RESULTS: Temporal T-wave parameters Tpeak-end , Twidth, and TQratio show a significant and high correlation with RT gradient, best reflected by mean value. Tarea (mean, max and dispersion) and dV/dtmax dispersion show only a moderate significant correlation. T-upslope duration shows a significant correlation in particular for mean values. Mean, maximum, or dispersion of QTtime and V1 -V6 upslope end difference were not significantly correlated with RT gradient. CONCLUSION: Composite 12-lead ECG T-wave parameters Tpeak-end , Twidth , TQratio , upslope duration, and Tarea show a good correlation with underlying RT heterogeneity, whereas standard clinical metrics such as QTtime do not reflect local RT heterogeneity. The composite T-wave metrics may thus provide better insights in arrhythmia susceptibility than traditional QTtime metrics.


Assuntos
Arritmias Cardíacas , Eletrocardiografia , Humanos , Suínos , Animais , Coração , Pinacidil
11.
J Cardiovasc Electrophysiol ; 32(3): 570-577, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33476463

RESUMO

BACKGROUND: Ultralow temperature cyroablation (ULTC) is designed to create focal, linear, and circumferential lesions. The aim of this study was to assess the safety, efficacy, and durability of atrial and ventricular ULTC lesions in preclinical large animal models. METHODS AND RESULTS: The ULTC system uses nitrogen near its liquid-vapor critical point to cool 11-cm ablation catheters. The catheter can be shaped to specific anatomies using pre-shaped stylets. ULTC was used in 11 swine and four sheep to create atrial (pulmonary vein isolation and linear ablation) and ventricular lesions. Acute and 90-day success were evaluated by intracardiac mapping and histologic examination. Cryoadherence was observed during all ULTC applications, ensuring catheter stability at target locations. Local electrograms were completely eliminated immediately after the first single-shot ULTC application in 49 of 53 (92.5%) atrial and in 31 of 32 (96.9%) ventricular applications. Lesion depth as measured on histology preparations was 1.96 ± 0.8 mm in atrial and 5.61 ± 2.2 mm in ventricular lesions. In all animals, voltage maps and histology demonstrated transmural and durable lesions without gaps, surrounded by intact collagen fibers without injury to surrounding tissues. Transient coronary spasm could be provoked with endocardial ULTC in the left ventricle in close proximity to a coronary artery. CONCLUSIONS: ULTC created effective and efficient atrial and ventricular lesions in vivo without procedural complications in two large animal models. ULTC lesions were transmural, contiguous, and durable over 3 months.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Animais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Átrios do Coração/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Veias Pulmonares/cirurgia , Ovinos , Suínos , Temperatura
12.
J Cardiovasc Electrophysiol ; 31(6): 1493-1506, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32333433

RESUMO

BACKGROUND: Morphology algorithms are currently recommended as a standalone discriminator in single-chamber implantable cardioverter defibrillators (ICDs). However, these proprietary algorithms differ in both design and nominal programming. OBJECTIVE: To compare three different algorithms with nominal versus advanced programming in their ability to discriminate between ventricular (VT) and supraventricular tachycardia (SVT). METHODS: In nine European centers, VT and SVTs were collected from Abbott, Boston Scientific, and Medtronic dual- and triple-chamber ICDs via their respective remote monitoring portals. Percentage morphology matches were recorded for selected episodes which were classified as VT or SVT by means of atrioventricular comparison. The sensitivity and related specificity of each manufacturer discriminator was determined at various values of template match percentage from receiving operating characteristics (ROC) curve analysis. RESULTS: A total of 534 episodes were retained for the analysis. In ROC analyses, Abbott Far Field MD (area under the curve [AUC]: 0.91; P < .001) and Boston Scientific RhythmID (AUC: 0.95; P < .001) show higher AUC than Medtronic Wavelet (AUC: 0.81; P < .001) when tested for their ability to discriminate VT from SVT. At nominal % match threshold all devices provided high sensitivity in VT identification, (91%, 100%, and 90%, respectively, for Abbott, Boston Scientific, and Medtronic) but contrasted specificities in SVT discrimination (85%, 41%, and 62%, respectively). Abbott and Medtronic's nominal thresholds were similar to the optimal thresholds. Optimization of the % match threshold improved the Boston Scientific specificity to 79% without compromising the sensitivity. CONCLUSION: Proprietary morphology discriminators show important differences in their ability to discriminate SVT. How much this impact the overall discrimination process remains to be investigated.


Assuntos
Algoritmos , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Processamento de Sinais Assistido por Computador , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico , Telemetria/instrumentação , Potenciais de Ação , Diagnóstico Diferencial , Desenho de Equipamento , Europa (Continente) , Frequência Cardíaca , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/terapia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/terapia
13.
PLoS Comput Biol ; 14(5): e1006166, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29795549

RESUMO

Success rates for catheter ablation of persistent atrial fibrillation patients are currently low; however, there is a subset of patients for whom electrical isolation of the pulmonary veins alone is a successful treatment strategy. It is difficult to identify these patients because there are a multitude of factors affecting arrhythmia susceptibility and maintenance, and the individual contributions of these factors are difficult to determine clinically. We hypothesised that the combination of pulmonary vein (PV) electrophysiology and atrial body fibrosis determine driver location and effectiveness of pulmonary vein isolation (PVI). We used bilayer biatrial computer models based on patient geometries to investigate the effects of PV properties and atrial fibrosis on arrhythmia inducibility, maintenance mechanisms, and the outcome of PVI. Short PV action potential duration (APD) increased arrhythmia susceptibility, while longer PV APD was found to be protective. Arrhythmia inducibility increased with slower conduction velocity (CV) at the LA/PV junction, but not for cases with homogeneous CV changes or slower CV at the distal PV. Phase singularity (PS) density in the PV region for cases with PV fibrosis was increased. Arrhythmia dynamics depend on both PV properties and fibrosis distribution, varying from meandering rotors to PV reentry (in cases with baseline or long APD), to stable rotors at regions of high fibrosis density. Measurement of fibrosis and PV properties may indicate patient specific susceptibility to AF initiation and maintenance. PV PS density before PVI was higher for cases in which AF terminated or converted to a macroreentry; thus, high PV PS density may indicate likelihood of PVI success.


Assuntos
Fibrilação Atrial/fisiopatologia , Simulação por Computador , Fibrose/fisiopatologia , Modelos Cardiovasculares , Veias Pulmonares/fisiopatologia , Potenciais de Ação/fisiologia , Eletrofisiologia Cardíaca , Ablação por Cateter , Átrios do Coração/fisiopatologia , Humanos
14.
J Pediatr Gastroenterol Nutr ; 69(5): 523-527, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31259787

RESUMO

OBJECTIVES: Per-oral endoscopic myotomy (POEM) is a recommended treatment modality for achalasia, but there is little published data for its use in children. The objective of the present study was to evaluate whether POEM is clinically effective and safe for children. METHODS: International multicenter retrospective study conducted in 14 tertiary centers that included consecutive children who underwent POEM between January 2012 and August 2018. Outcomes, such as clinical response were assessed whenever available. Adverse events and factors associated with clinical failure were also investigated. RESULTS: A total of 117 patients (mean ±â€ŠSD age: 14.2 ±â€Š3.7 years) underwent POEM for achalasia (type I, n = 36; type II n=66; type III, n=8). Among these, 30 (26%) were pretreated (botulinum injection and/or pneumatic dilatation). Mean ±â€ŠSD baseline Eckardt score was 7.5 ±â€Š2.0. Clinical success was achieved in 90.6% of cases (95%CI [83.8%;95.2%]) in the intention-to-treat analysis. The mean ±â€ŠSD Eckardt score post-POEM was 0.9 ±â€Š1.2 (P < 0.001). The mean duration of follow-up time 545 days (range: 100-1612). A total of 7 adverse events occurred (4 mucosotomies, 2 subcutaneous emphysema, 1 esopleural fistula). Gastroesophageal reflux symptoms were seen in 17 patients (15%); missing data for 10 patients (9%). There was a trend towards more frequent clinical failure in achalasia associated with genetic disorders (40% vs 8%, P = 0.069). CONCLUSIONS: POEM in pediatric patients appears to be effective and safe, although there was a trend towards more frequent clinical failure achalasia associated with genetic disorders. Further studies are needed to assess the long-term outcomes, especially the consequences of GERD.


Assuntos
Acalasia Esofágica/cirurgia , Miotomia , Cirurgia Endoscópica por Orifício Natural , Adolescente , Dilatação , Europa (Continente) , Feminino , Humanos , Japão , Masculino , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Estados Unidos
15.
J Electrocardiol ; 57S: S15-S20, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31477238

RESUMO

BACKGROUND: With increasing clinical use of Electrocardiographic Imaging (ECGI), it is imperative to understand the limits of this technique. The objective of this study is to evaluate a potential-based ECGI approach for activation and repolarization mapping in sinus rhythm. METHOD: Langendorff-perfused pig hearts were suspended in a human-shaped torso tank. Electrograms were recorded with a 108-electrode sock and ECGs with 256 electrodes embedded in the tank surface. Left bundle branch block (LBBB) was developed in 4 hearts through ablation, and repolarization abnormalities in another 4 hearts through regional perfusion of dofetilide and pinacidil. Electrograms were noninvasively reconstructed and reconstructed activation and repolarization features were compared to those recorded. RESULTS: Visual consistency between ECGI and recorded activation and repolarization maps was high. While reconstructed repolarization times showed significantly more error than activation times quantitatively, patterns were reconstructed with a similar level of accuracy. The number of epicardial breakthrough sites was underestimated by ECGI and these were misplaced (>20 mm) in location. Likewise, ECGI reconstructed activation maps demonstrated artificial lines of block resulting from a W-shaped QRS waveform that were not present in recorded maps. Nevertheless, ECGI allowed identification of regions of abnormal repolarization reasonably accurately in terms of size, location and timing. CONCLUSIONS: This study validates a potential-based ECGI approach to noninvasively image activation and recovery in sinus rhythm. Despite inaccuracies in epicardial breakthroughs and lines of conduction block, other important clinical features such as regions of abnormal repolarization can be accurately derived making ECGI a valuable clinical tool.


Assuntos
Arritmias Cardíacas , Mapeamento Potencial de Superfície Corporal , Eletrocardiografia , Animais , Arritmias Cardíacas/diagnóstico , Diagnóstico por Imagem , Testes Diagnósticos de Rotina , Suínos
16.
Circulation ; 136(25): 2491-2507, 2017 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-29255125

RESUMO

Ventricular tachycardia (VT) is a major cause of sudden cardiac death. The majority of malignant VTs occur in patients with structural heart disease. Multimodality imaging techniques play an integral role in determining the underlying etiology and prognostic significance of VT. In recent years, advances in imaging technology have enabled characterization of the structural arrhythmogenic substrate in patients with VT with increasing precision. In parallel with these advances, the role of cardiac imaging has expanded from a largely diagnostic tool to an adjunctive tool to guide interventional approaches for treatment of VT. Invasive and noninvasive imaging techniques, often used in combination, have made it possible to integrate structural and electrophysiological information during VT ablation procedures. An important area of current development is the use of noninvasive imaging techniques based on body surface electrocardiographic mapping to elucidate the mechanisms of VT. In the future, these techniques may provide a priori information on mechanisms of VT in patients undergoing interventional procedures. This review provides an overview of the role of cardiac imaging in patients with VT.


Assuntos
Coração/diagnóstico por imagem , Taquicardia Ventricular/diagnóstico , Angiografia Coronária , Ecocardiografia , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Tomografia Computadorizada Multidetectores , Fatores de Risco , Taquicardia Ventricular/patologia
19.
J Cardiovasc Electrophysiol ; 29(2): 274-283, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29072796

RESUMO

INTRODUCTION: It is largely believed that atrial tachycardias (ATs) encountered during ablation of persistent atrial fibrillation (PsAF) are a byproduct of ablative lesions. We aimed to explore the alternative hypothesis that they may be a priori drivers of AF remaining masked until other AF sources are reduced or eliminated. METHODS AND RESULTS: Radiofrequency ablation of fibrillatory drivers mapped by electrocardiographic imaging (ECGI; ECVUE™, Cardioinsight Technologies, Cleveland, OH, USA) terminated PsAF in 198 (73%) out of 270 patients (61 ± 10 years, 9 ± 9 m). Two hundred and six ATs in 158 patients were subsequently mapped. Their anatomic relationship to the fibrillatory drivers prospectively identified by ECGI was then established. There were 26 (13%), 52 (25%), and 128 (62%) focal, localized, and macrore-entrant ATs, respectively. In focal/localized re-entrant ATs, 64 (82%) were terminated within an AF-driver region, in which 26 (81%) among 32 focal/localized ATs analyzed with 3-D-mapping system merged to driver map occurred from AF-driver regions in 1.0 ± 1.0 cm distance from the driver core. Importantly, there was no attempt at ablation of the associated AF-driver region in 25 of 64 (39%) of focal/localized re-entrant ATs. The sites of ATs origin generally had low-voltage, fractionated, and long-duration electrograms in AF. All but two focal/localized re-entrant ATs were successfully ablated. CONCLUSION: The majority of post-AF-ablation focal and localized re-entrant ATs originate from the region of prospectively established AF-driver regions. A third of these are localized to regions not subsequently submitted to ablation. These data suggest that many ATs exist, although not necessarily manifest independently, prior to ablation. They may have a role in the maintenance of PsAF in these individuals.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Taquicardia Supraventricular/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa