1.
N Engl J Med ; 388(11): 991-1001, 2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36920756

RESUMO

BACKGROUND: Closed-loop control systems of insulin delivery may improve glycemic outcomes in young children with type 1 diabetes. The efficacy and safety of initiating a closed-loop system virtually are unclear. METHODS: In this 13-week, multicenter trial, we randomly assigned, in a 2:1 ratio, children who were at least 2 years of age but younger than 6 years of age who had type 1 diabetes to receive treatment with a closed-loop system of insulin delivery or standard care that included either an insulin pump or multiple daily injections of insulin plus a continuous glucose monitor. The primary outcome was the percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter, as measured by continuous glucose monitoring. Secondary outcomes included the percentage of time that the glucose level was above 250 mg per deciliter or below 70 mg per deciliter, the mean glucose level, the glycated hemoglobin level, and safety outcomes. RESULTS: A total of 102 children underwent randomization (68 to the closed-loop group and 34 to the standard-care group); the glycated hemoglobin levels at baseline ranged from 5.2 to 11.5%. Initiation of the closed-loop system was virtual in 55 patients (81%). The mean (±SD) percentage of time that the glucose level was within the target range increased from 56.7±18.0% at baseline to 69.3±11.1% during the 13-week follow-up period in the closed-loop group and from 54.9±14.7% to 55.9±12.6% in the standard-care group (mean adjusted difference, 12.4 percentage points [equivalent to approximately 3 hours per day]; 95% confidence interval, 9.5 to 15.3; P<0.001). We observed similar treatment effects (favoring the closed-loop system) on the percentage of time that the glucose level was above 250 mg per deciliter, on the mean glucose level, and on the glycated hemoglobin level, with no significant between-group difference in the percentage of time that the glucose level was below 70 mg per deciliter. There were two cases of severe hypoglycemia in the closed-loop group and one case in the standard-care group. One case of diabetic ketoacidosis occurred in the closed-loop group. CONCLUSIONS: In this trial involving young children with type 1 diabetes, the glucose level was in the target range for a greater percentage of time with a closed-loop system than with standard care. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases; PEDAP ClinicalTrials.gov number, NCT04796779.).


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Criança , Pré-Escolar , Humanos , Glicemia/análise , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/efeitos adversos , Insulina/uso terapêutico , Sistemas de Infusão de Insulina/efeitos adversos
2.
N Engl J Med ; 387(13): 1161-1172, 2022 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-36170500

RESUMO

BACKGROUND: Currently available semiautomated insulin-delivery systems require individualized insulin regimens for the initialization of therapy and meal doses based on carbohydrate counting for routine operation. In contrast, the bionic pancreas is initialized only on the basis of body weight, makes all dose decisions and delivers insulin autonomously, and uses meal announcements without carbohydrate counting. METHODS: In this 13-week, multicenter, randomized trial, we randomly assigned in a 2:1 ratio persons at least 6 years of age with type 1 diabetes either to receive bionic pancreas treatment with insulin aspart or insulin lispro or to receive standard care (defined as any insulin-delivery method with unblinded, real-time continuous glucose monitoring). The primary outcome was the glycated hemoglobin level at 13 weeks. The key secondary outcome was the percentage of time that the glucose level as assessed by continuous glucose monitoring was below 54 mg per deciliter; the prespecified noninferiority limit for this outcome was 1 percentage point. Safety was also assessed. RESULTS: A total of 219 participants 6 to 79 years of age were assigned to the bionic-pancreas group, and 107 to the standard-care group. The glycated hemoglobin level decreased from 7.9% to 7.3% in the bionic-pancreas group and did not change (was at 7.7% at both time points) in the standard-care group (mean adjusted difference at 13 weeks, -0.5 percentage points; 95% confidence interval [CI], -0.6 to -0.3; P<0.001). The percentage of time that the glucose level as assessed by continuous glucose monitoring was below 54 mg per deciliter did not differ significantly between the two groups (13-week adjusted difference, 0.0 percentage points; 95% CI, -0.1 to 0.04; P<0.001 for noninferiority). The rate of severe hypoglycemia was 17.7 events per 100 participant-years in the bionic-pancreas group and 10.8 events per 100 participant-years in the standard-care group (P = 0.39). No episodes of diabetic ketoacidosis occurred in either group. CONCLUSIONS: In this 13-week, randomized trial involving adults and children with type 1 diabetes, use of a bionic pancreas was associated with a greater reduction than standard care in the glycated hemoglobin level. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases and others; ClinicalTrials.gov number, NCT04200313.).


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Insulina Aspart , Sistemas de Infusão de Insulina , Insulina Lispro , Adolescente , Adulto , Idoso , Biônica/instrumentação , Glicemia/análise , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Criança , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/efeitos adversos , Insulina/uso terapêutico , Insulina Aspart/administração & dosagem , Insulina Aspart/efeitos adversos , Insulina Aspart/uso terapêutico , Sistemas de Infusão de Insulina/efeitos adversos , Insulina Lispro/administração & dosagem , Insulina Lispro/efeitos adversos , Insulina Lispro/uso terapêutico , Pessoa de Meia-Idade , Adulto Jovem
3.
N Engl J Med ; 383(9): 836-845, 2020 08 27.
Artigo em Inglês | MEDLINE | ID: mdl-32846062

RESUMO

BACKGROUND: A closed-loop system of insulin delivery (also called an artificial pancreas) may improve glycemic outcomes in children with type 1 diabetes. METHODS: In a 16-week, multicenter, randomized, open-label, parallel-group trial, we assigned, in a 3:1 ratio, children 6 to 13 years of age who had type 1 diabetes to receive treatment with the use of either a closed-loop system of insulin delivery (closed-loop group) or a sensor-augmented insulin pump (control group). The primary outcome was the percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter, as measured by continuous glucose monitoring. RESULTS: A total of 101 children underwent randomization (78 to the closed-loop group and 23 to the control group); the glycated hemoglobin levels at baseline ranged from 5.7 to 10.1%. The mean (±SD) percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter increased from 53±17% at baseline to 67±10% (the mean over 16 weeks of treatment) in the closed-loop group and from 51±16% to 55±13% in the control group (mean adjusted difference, 11 percentage points [equivalent to 2.6 hours per day]; 95% confidence interval, 7 to 14; P<0.001). In both groups, the median percentage of time that the glucose level was below 70 mg per deciliter was low (1.6% in the closed-loop group and 1.8% in the control group). In the closed-loop group, the median percentage of time that the system was in the closed-loop mode was 93% (interquartile range, 91 to 95). No episodes of diabetic ketoacidosis or severe hypoglycemia occurred in either group. CONCLUSIONS: In this 16-week trial involving children with type 1 diabetes, the glucose level was in the target range for a greater percentage of time with the use of a closed-loop system than with the use of a sensor-augmented insulin pump. (Funded by Tandem Diabetes Care and the National Institute of Diabetes and Digestive and Kidney Diseases; ClinicalTrials.gov number, NCT03844789.).


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Bombas de Infusão Implantáveis , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Adolescente , Glicemia/análise , Criança , Diabetes Mellitus Tipo 1/sangue , Cetoacidose Diabética/etiologia , Feminino , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemiantes/efeitos adversos , Injeções Subcutâneas , Insulina/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos , Masculino , Pâncreas Artificial
4.
Pharmacol Res ; 195: 106882, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37543096

RESUMO

Type 1 diabetes (T1D) is the most frequent form of diabetes in pediatric age, affecting more than 1.5 million people younger than age 20 years worldwide. Early and intensive control of diabetes provides continued protection against both microvascular and macrovascular complications, enhances growth, and ensures normal pubertal development. In the absence of definitive reversal therapy for this disease, achieving and maintaining the recommended glycemic targets is crucial. In the last 30 years, enormous progress has been made using technology to better treat T1D. In spite of this progress, the majority of children, adolescents and young adults do not reach the recommended targets for glycemic control and assume a considerable burden each day. The development of promising new therapeutic advances, such as more physiologic insulin analogues, pioneering diabetes technology including continuous glucose monitoring and closed loop systems as well as new adjuvant drugs, anticipate a new paradigm in T1D management over the next few years. This review presents insights into current management of T1D in youths.


Assuntos
Diabetes Mellitus Tipo 1 , Adulto Jovem , Humanos , Adolescente , Criança , Adulto , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Controle Glicêmico , Automonitorização da Glicemia , Glicemia , Insulina/uso terapêutico , Sistemas de Infusão de Insulina
5.
JAMA ; 329(12): 980-989, 2023 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-36826834

RESUMO

Importance: Near normalization of glucose levels instituted immediately after diagnosis of type 1 diabetes has been postulated to preserve pancreatic beta cell function by reducing glucotoxicity. Previous studies have been hampered by an inability to achieve tight glycemic goals. Objective: To determine the effectiveness of intensive diabetes management to achieve near normalization of glucose levels on preservation of pancreatic beta cell function in youth with newly diagnosed type 1 diabetes. Design, Setting, and Participants: This randomized, double-blind, clinical trial was conducted at 6 centers in the US (randomizations from July 20, 2020, to October 13, 2021; follow-up completed September 15, 2022) and included youths with newly diagnosed type 1 diabetes aged 7 to 17 years. Interventions: Random assignment to intensive diabetes management, which included use of an automated insulin delivery system (n = 61), or standard care, which included use of a continuous glucose monitor (n = 52), as part of a factorial design in which participants weighing 30 kg or more also were assigned to receive either oral verapamil or placebo. Main Outcomes and Measures: The primary outcome was mixed-meal tolerance test-stimulated C-peptide area under the curve (a measure of pancreatic beta cell function) 52 weeks from diagnosis. Results: Among 113 participants (mean [SD] age, 11.8 [2.8] years; 49 females [43%]; mean [SD] time from diagnosis to randomization, 24 [5] days), 108 (96%) completed the trial. The mean C-peptide area under the curve decreased from 0.57 pmol/mL at baseline to 0.45 pmol/mL at 52 weeks in the intensive management group, and from 0.60 to 0.50 pmol/mL in the standard care group (treatment group difference, -0.01 [95% CI, -0.11 to 0.10]; P = .89). The mean time in the target range of 70 to 180 mg/dL, measured with continuous glucose monitoring, at 52 weeks was 78% in the intensive management group vs 64% in the standard care group (adjusted difference, 16% [95% CI, 10% to 22%]). One severe hypoglycemia event and 1 diabetic ketoacidosis event occurred in each group. Conclusions and Relevance: In youths with newly diagnosed type 1 diabetes, intensive diabetes management, which included automated insulin delivery, achieved excellent glucose control but did not affect the decline in pancreatic C-peptide secretion at 52 weeks. Trial Registration: ClinicalTrials.gov Identifier: NCT04233034.


Assuntos
Diabetes Mellitus Tipo 1 , Células Secretoras de Insulina , Feminino , Adolescente , Humanos , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/administração & dosagem , Glicemia/efeitos dos fármacos , Células Secretoras de Insulina/efeitos dos fármacos , Peptídeo C/farmacologia , Peptídeo C/uso terapêutico , Método Duplo-Cego , Controle Glicêmico , Automonitorização da Glicemia , Hemoglobinas Glicadas , Insulina/efeitos adversos , Insulina/administração & dosagem
6.
JAMA ; 329(12): 990-999, 2023 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-36826844

RESUMO

Importance: In preclinical studies, thioredoxin-interacting protein overexpression induces pancreatic beta cell apoptosis and is involved in glucotoxicity-induced beta cell death. Calcium channel blockers reduce these effects and may be beneficial to beta cell preservation in type 1 diabetes. Objective: To determine the effect of verapamil on pancreatic beta cell function in children and adolescents with newly diagnosed type 1 diabetes. Design, Setting, and Participants: This double-blind, randomized clinical trial including children and adolescents aged 7 to 17 years with newly diagnosed type 1 diabetes who weighed 30 kg or greater was conducted at 6 centers in the US (randomized participants between July 20, 2020, and October 13, 2021) and follow-up was completed on September 15, 2022. Interventions: Participants were randomly assigned 1:1 to once-daily oral verapamil (n = 47) or placebo (n = 41) as part of a factorial design in which participants also were assigned to receive either intensive diabetes management or standard diabetes care. Main Outcomes and Measures: The primary outcome was area under the curve values for C-peptide level (a measure of pancreatic beta cell function) stimulated by a mixed-meal tolerance test at 52 weeks from diagnosis of type 1 diabetes. Results: Among 88 participants (mean age, 12.7 [SD, 2.4] years; 36 were female [41%]; and the mean time from diagnosis to randomization was 24 [SD, 4] days), 83 (94%) completed the trial. In the verapamil group, the mean C-peptide area under the curve was 0.66 pmol/mL at baseline and 0.65 pmol/mL at 52 weeks compared with 0.60 pmol/mL at baseline and 0.44 pmol/mL at 52 weeks in the placebo group (adjusted between-group difference, 0.14 pmol/mL [95% CI, 0.01 to 0.27 pmol/mL]; P = .04). This equates to a 30% higher C-peptide level at 52 weeks with verapamil. The percentage of participants with a 52-week peak C-peptide level of 0.2 pmol/mL or greater was 95% (41 of 43 participants) in the verapamil group vs 71% (27 of 38 participants) in the placebo group. At 52 weeks, hemoglobin A1c was 6.6% in the verapamil group vs 6.9% in the placebo group (adjusted between-group difference, -0.3% [95% CI, -1.0% to 0.4%]). Eight participants (17%) in the verapamil group and 8 participants (20%) in the placebo group had a nonserious adverse event considered to be related to treatment. Conclusions and Relevance: In children and adolescents with newly diagnosed type 1 diabetes, verapamil partially preserved stimulated C-peptide secretion at 52 weeks from diagnosis compared with placebo. Further studies are needed to determine the longitudinal durability of C-peptide improvement and the optimal length of therapy. Trial Registration: ClinicalTrials.gov Identifier: NCT04233034.


Assuntos
Diabetes Mellitus Tipo 1 , Células Secretoras de Insulina , Adolescente , Humanos , Criança , Feminino , Masculino , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Peptídeo C/metabolismo , Peptídeo C/farmacologia , Peptídeo C/uso terapêutico , Método Duplo-Cego , Verapamil/efeitos adversos , Células Secretoras de Insulina/efeitos dos fármacos
7.
N Engl J Med ; 381(18): 1707-1717, 2019 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-31618560

RESUMO

BACKGROUND: Closed-loop systems that automate insulin delivery may improve glycemic outcomes in patients with type 1 diabetes. METHODS: In this 6-month randomized, multicenter trial, patients with type 1 diabetes were assigned in a 2:1 ratio to receive treatment with a closed-loop system (closed-loop group) or a sensor-augmented pump (control group). The primary outcome was the percentage of time that the blood glucose level was within the target range of 70 to 180 mg per deciliter (3.9 to 10.0 mmol per liter), as measured by continuous glucose monitoring. RESULTS: A total of 168 patients underwent randomization; 112 were assigned to the closed-loop group, and 56 were assigned to the control group. The age range of the patients was 14 to 71 years, and the glycated hemoglobin level ranged from 5.4 to 10.6%. All 168 patients completed the trial. The mean (±SD) percentage of time that the glucose level was within the target range increased in the closed-loop group from 61±17% at baseline to 71±12% during the 6 months and remained unchanged at 59±14% in the control group (mean adjusted difference, 11 percentage points; 95% confidence interval [CI], 9 to 14; P<0.001). The results with regard to the main secondary outcomes (percentage of time that the glucose level was >180 mg per deciliter, mean glucose level, glycated hemoglobin level, and percentage of time that the glucose level was <70 mg per deciliter or <54 mg per deciliter [3.0 mmol per liter]) all met the prespecified hierarchical criterion for significance, favoring the closed-loop system. The mean difference (closed loop minus control) in the percentage of time that the blood glucose level was lower than 70 mg per deciliter was -0.88 percentage points (95% CI, -1.19 to -0.57; P<0.001). The mean adjusted difference in glycated hemoglobin level after 6 months was -0.33 percentage points (95% CI, -0.53 to -0.13; P = 0.001). In the closed-loop group, the median percentage of time that the system was in closed-loop mode was 90% over 6 months. No serious hypoglycemic events occurred in either group; one episode of diabetic ketoacidosis occurred in the closed-loop group. CONCLUSIONS: In this 6-month trial involving patients with type 1 diabetes, the use of a closed-loop system was associated with a greater percentage of time spent in a target glycemic range than the use of a sensor-augmented insulin pump. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases; iDCL ClinicalTrials.gov number, NCT03563313.).


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Pâncreas Artificial , Adolescente , Adulto , Idoso , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Desenho de Equipamento , Feminino , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos , Masculino , Pessoa de Meia-Idade , Pâncreas Artificial/efeitos adversos , Adulto Jovem
8.
Pediatr Diabetes ; 23(3): 324-329, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35001477

RESUMO

BACKGROUND: Highly variable insulin sensitivity, susceptibility to hypoglycemia and inability to effectively communicate hypoglycemic symptoms pose significant challenges for young children with type 1 diabetes (T1D). Herein, outcomes during clinical MiniMed™ 670G system use were evaluated in children aged 2-6 years with T1D. METHODS: Participants (N = 46, aged 4.6 ± 1.4 years) at seven investigational centers used the MiniMed™ 670G system in Manual Mode during a two-week run-in period followed by Auto Mode during a three-month study phase. Safety events, mean A1C, sensor glucose (SG), and percentage of time spent in (TIR, 70-180 mg/dl), below (TBR, <70 mg/dl) and above (TAR, >180 mg/dl) range were assessed for the run-in and study phase and compared using a paired t-test or Wilcoxon signed-rank test. RESULTS: From run-in to end of study (median 87.1% time in auto mode), mean A1C and SG changed from 8.0 ± 0.9% to 7.5 ± 0.6% (p < 0.001) and from 173 ± 24 to 161 ± 16 mg/dl (p < 0.001), respectively. Overall TIR increased from 55.7 ± 13.4% to 63.8 ± 9.4% (p < 0.001), while TBR and TAR decreased from 3.3 ± 2.5% to 3.2 ± 1.6% (p = 0.996) and 41.0 ± 14.7% to 33.0 ± 9.9% (p < 0.001), respectively. Overnight TBR remained unchanged and TAR was further improved 12:00 am-6:00 am. Throughout the study phase, there were no episodes of severe hypoglycemia or diabetic ketoacidosis (DKA) and no serious adverse device-related events. CONCLUSIONS: At-home MiniMed™ 670G Auto Mode use by young children safely improved glycemic outcomes compared to two-week open-loop Manual Mode use. The improvements are similar to those observed in older children, adolescents and adults with T1D using the same system for the same duration of time.


Assuntos
Diabetes Mellitus Tipo 1 , Sistemas de Infusão de Insulina , Glicemia , Automonitorização da Glicemia , Criança , Pré-Escolar , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Sistemas de Infusão de Insulina/efeitos adversos
10.
Pediatr Diabetes ; 20(6): 759-768, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31099946

RESUMO

OBJECTIVE: Artificial pancreas (AP) systems have been shown to improve glycemic control throughout the day and night in adults, adolescents, and children. However, AP testing remains limited during intense and prolonged exercise in adolescents and children. We present the performance of the Tandem Control-IQ AP system in adolescents and children during a winter ski camp study, where high altitude, low temperature, prolonged intense activity, and stress challenged glycemic control. METHODS: In a randomized controlled trial, 24 adolescents (ages 13-18 years) and 24 school-aged children (6-12 years) with Type 1 diabetes (T1D) participated in a 48 hours ski camp (∼5 hours skiing/day) at three sites: Wintergreen, VA; Kirkwood, and Breckenridge, CO. Study participants were randomized 1:1 at each site. The control group used remote monitored sensor-augmented pump (RM-SAP), and the experimental group used the t: slim X2 with Control-IQ Technology AP system. All subjects were remotely monitored 24 hours per day by study staff. RESULTS: The Control-IQ system improved percent time within range (70-180 mg/dL) over the entire camp duration: 66.4 ± 16.4 vs 53.9 ± 24.8%; P = .01 in both children and adolescents. The AP system was associated with a significantly lower average glucose based on continuous glucose monitor data: 161 ± 29.9 vs 176.8 ± 36.5 mg/dL; P = .023. There were no differences between groups for hypoglycemia exposure or carbohydrate interventions. There were no adverse events. CONCLUSIONS: The use of the Control-IQ AP improved glycemic control and safely reduced exposure to hyperglycemia relative to RM-SAP in pediatric patients with T1D during prolonged intensive winter sport activities.


Assuntos
Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Pâncreas Artificial , Esqui/fisiologia , Esportes/fisiologia , Adolescente , Glicemia/efeitos dos fármacos , Glicemia/metabolismo , Automonitorização da Glicemia/efeitos adversos , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Criança , Temperatura Baixa , Estudos Cross-Over , Desenho de Equipamento , Feminino , Humanos , Hiperglicemia/etiologia , Hipoglicemia/etiologia , Insulina/administração & dosagem , Insulina/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos , Masculino , Pâncreas Artificial/efeitos adversos , Estações do Ano
11.
Lancet ; 389(10067): 369-380, 2017 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-28007348

RESUMO

BACKGROUND: The safety and effectiveness of a continuous, day-and-night automated glycaemic control system using insulin and glucagon has not been shown in a free-living, home-use setting. We aimed to assess whether bihormonal bionic pancreas initialised only with body mass can safely reduce mean glycaemia and hypoglycaemia in adults with type 1 diabetes who were living at home and participating in their normal daily routines without restrictions on diet or physical activity. METHODS: We did a random-order crossover study in volunteers at least 18 years old who had type 1 diabetes and lived within a 30 min drive of four sites in the USA. Participants were randomly assigned (1:1) in blocks of two using sequentially numbered sealed envelopes to glycaemic regulation with a bihormonal bionic pancreas or usual care (conventional or sensor-augmented insulin pump therapy) first, followed by the opposite intervention. Both study periods were 11 days in length, during which time participants continued all normal activities, including athletics and driving. The bionic pancreas was initialised with only the participant's body mass. Autonomously adaptive dosing algorithms used data from a continuous glucose monitor to control subcutaneous delivery of insulin and glucagon. The coprimary outcomes were the mean glucose concentration and time with continuous glucose monitoring (CGM) glucose concentration less than 3·3 mmol/L, analysed over days 2-11 in participants who completed both periods of the study. This trial is registered with ClinicalTrials.gov, number NCT02092220. FINDINGS: We randomly assigned 43 participants between May 6, 2014, and July 3, 2015, 39 of whom completed the study: 20 who were assigned to bionic pancreas first and 19 who were assigned to the comparator first. The mean CGM glucose concentration was 7·8 mmol/L (SD 0·6) in the bionic pancreas period versus 9·0 mmol/L (1·6) in the comparator period (difference 1·1 mmol/L, 95% CI 0·7-1·6; p<0·0001), and the mean time with CGM glucose concentration less than 3·3 mmol/L was 0·6% (0·6) in the bionic pancreas period versus 1·9% (1·7) in the comparator period (difference 1·3%, 95% CI 0·8-1·8; p<0·0001). The mean nausea score on the Visual Analogue Scale (score 0-10) was greater during the bionic pancreas period (0·52 [SD 0·83]) than in the comparator period (0·05 [0·17]; difference 0·47, 95% CI 0·21-0·73; p=0·0024). Body mass and laboratory parameters did not differ between periods. There were no serious or unexpected adverse events in the bionic pancreas period of the study. INTERPRETATION: Relative to conventional and sensor-augmented insulin pump therapy, the bihormonal bionic pancreas, initialised only with participant weight, was able to achieve superior glycaemic regulation without the need for carbohydrate counting. Larger and longer studies are needed to establish the long-term benefits and risks of automated glycaemic management with a bihormonal bionic pancreas. FUNDING: National Institute of Diabetes and Digestive and Kidney Diseases of the National Institutes of Health, and National Center for Advancing Translational Sciences.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucagon/administração & dosagem , Hormônios/administração & dosagem , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Pâncreas Artificial , Adulto , Biônica , Glicemia/metabolismo , Estudos Cross-Over , Diabetes Mellitus Tipo 1/metabolismo , Feminino , Glucagon/uso terapêutico , Hormônios/uso terapêutico , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Náusea/induzido quimicamente , Adulto Jovem
12.
Pediatr Diabetes ; 19(3): 420-428, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29159870

RESUMO

OBJECTIVE: The primary objective of this trial was to evaluate the feasibility, safety, and efficacy of a predictive hyperglycemia and hypoglycemia minimization (PHHM) system vs predictive low glucose suspension (PLGS) alone in optimizing overnight glucose control in children 6 to 14 years old. RESEARCH DESIGN AND METHODS: Twenty-eight participants 6 to 14 years old with T1D duration ≥1 year with daily insulin therapy ≥12 months and on insulin pump therapy for ≥6 months were randomized per night into PHHM mode or PLGS-only mode for 42 nights. The primary outcome was percentage of time in sensor-measured range 70 to 180 mg/dL in the overnight period. RESULTS: The addition of automated insulin delivery with PHHM increased time in target range (70-180 mg/dL) from 66 ± 11% during PLGS nights to 76 ± 9% during PHHM nights (P<.001), without increasing hypoglycemia as measured by time below various thresholds. Average morning blood glucose improved from 176 ± 28 mg/dL following PLGS nights to 154 ± 19 mg/dL following PHHM nights (P<.001). CONCLUSIONS: The PHHM system was effective in optimizing overnight glycemic control, significantly increasing time in range, lowering mean glucose, and decreasing glycemic variability compared to PLGS alone in children 6 to 14 years old.


Assuntos
Diabetes Mellitus Tipo 1/sangue , Hiperglicemia/prevenção & controle , Hipoglicemia/prevenção & controle , Sistemas de Infusão de Insulina , Monitorização Ambulatorial/instrumentação , Adolescente , Glicemia , Criança , Alarmes Clínicos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Método Duplo-Cego , Estudos de Viabilidade , Feminino , Humanos , Masculino
13.
IEEE Trans Biomed Eng ; 71(3): 977-986, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37844003

RESUMO

OBJECTIVE: Modeling the effect of meal composition on glucose excursion would help in designing decision support systems (DSS) for type 1 diabetes (T1D) management. In fact, macronutrients differently affect post-prandial gastric retention (GR), rate of appearance (R[Formula: see text]), and insulin sensitivity (S[Formula: see text]). Such variables can be estimated, in inpatient settings, from plasma glucose (G) and insulin (I) data using the Oral glucose Minimal Model (OMM) coupled with a physiological model of glucose transit through the gastrointestinal tract (reference OMM, R-OMM). Here, we present a model able to estimate those quantities in daily-life conditions, using minimally-invasive (MI) technologies, and validate it against the R-OMM. METHODS: Forty-seven individuals with T1D (weight =78±13 kg, age =42±10 yr) underwent three 23-hour visits, during which G and I were frequently sampled while wearing continuous glucose monitoring (CGM) and insulin pump (IP). Using a Bayesian Maximum A Posteriori estimator, R-OMM was identified from plasma G and I measurements, and MI-OMM was identified from CGM and IP data. RESULTS: The MI-OMM fitted the CGM data well and provided precise parameter estimates. GR and R[Formula: see text] model parameters were not significantly different using the MI-OMM and R-OMM (p 0.05) and the correlation between the two S[Formula: see text] was satisfactory ( ρ =0.77). CONCLUSION: The MI-OMM is usable to estimate GR, R[Formula: see text], and S[Formula: see text] from data collected in real-life conditions with minimally-invasive technologies. SIGNIFICANCE: Applying MI-OMM to datasets where meal compositions are available will allow modeling the effect of each macronutrient on GR, R[Formula: see text], and S[Formula: see text]. DSS could finally exploit this information to improve diabetes management.


Assuntos
Diabetes Mellitus Tipo 1 , Resistência à Insulina , Humanos , Adulto , Pessoa de Meia-Idade , Glucose , Diabetes Mellitus Tipo 1/tratamento farmacológico , Resistência à Insulina/fisiologia , Glicemia , Automonitorização da Glicemia , Teorema de Bayes , Insulina , Hipoglicemiantes
14.
Artigo em Inglês | MEDLINE | ID: mdl-38805311

RESUMO

Objective: To evaluate the impact of missed or late meal boluses (MLBs) on glycemic outcomes in children and adolescents with type 1 diabetes using automated insulin delivery (AID) systems. Research Design and Methods: AID-treated (Tandem Control-IQ or Medtronic MiniMed 780G) children and adolescents (aged 6-21 years) from Stanford Medical Center and Steno Diabetes Center Copenhagen with ≥10 days of data were included in this two-center, binational, population-based, retrospective, 1-month cohort study. The primary outcome was the association between the number of algorithm-detected MLBs and time in target glucose range (TIR; 70-180 mg/dL). Results: The study included 189 children and adolescents (48% females with a mean ± standard deviation age of 13 ± 4 years). Overall, the mean number of MLBs per day in the cohort was 2.2 ± 0.9. For each additional MLB per day, TIR decreased by 9.7% points (95% confidence interval [CI] 11.3; 8.1), and compared with the quartile with fewest MLBs (Q1), the quartile with most (Q4) had 22.9% less TIR (95% CI: 27.2; 18.6). The age-, sex-, and treatment modality-adjusted probability of achieving a TIR of >70% in Q4 was 1.4% compared with 74.8% in Q1 (P < 0.001). Conclusions: MLBs significantly impacted glycemic outcomes in AID-treated children and adolescents. The results emphasize the importance of maintaining a focus on bolus behavior to achieve a higher TIR and support the need for further research in technological or behavioral support tools to handle MLBs.

15.
Diabetes Res Clin Pract ; 208: 111114, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38278493

RESUMO

OBJECTIVE: Examine patient-reported outcomes (PROs) after the use of t:slim X2 insulin pump with Control-IQ technology (CIQ) in young children with type 1 diabetes. METHODS: Children with type 1 diabetes, ages 2 to < 6 years (n = 102), were randomly assigned 2:1 to either CIQ or standard care (SC) with pump or multiple daily injections (MDI) plus continuous glucose monitoring (CGM) for 13 weeks. Both groups were offered to use CIQ for an additional 13 weeks after the randomized control trial's (RCT) completion. Guardians completed PRO questionnaires at baseline, 13-, and 26-weeks examining hypoglycemia concerns, quality of life, parenting stress, and sleep. At 26 weeks, 28 families participated in user-experience interviews. Repeated measures analyses compared PRO scores between systems used. RESULT: Comparing CIQ vs SC, responses on all 5 PRO surveys favored the CIQ group, showing that CIQ was superior to SC at 26 weeks (p values < 0.05). User-experience interviews indicated significant benefits in optimized glycemic control overall and nighttime control (28 of 28 families endorsed). All but 2/28 families noted substantial reduction in management burden resulting in less mental burden and all but 4 stated that they wanted their children to continue using CIQ. CONCLUSIONS: Families utilizing CIQ experienced glycemic benefits coupled with substantial benefits in PROs, documented in surveys and interviews. Families utilizing CIQ had reduced hypoglycemia concerns and parenting stress, and improved quality of life and sleep. These findings demonstrate the benefit of CIQ in young children with type 1 diabetes that goes beyond documented glycemic benefit.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Pré-Escolar , Humanos , Glicemia , Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Medidas de Resultados Relatados pelo Paciente
16.
J Clin Transl Endocrinol ; 36: 100352, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38860154

RESUMO

Objectives: To report the safety and side effects associated with taking verapamil for beta-cell preservation in children with newly-diagnosed T1D. Research Design and Methods: Eighty-eight participants aged 8.5 to 17.9 years weighing ≥ 30 kg were randomly assigned to verapamil (N = 47) or placebo (N = 41) within 31 days of T1D diagnosis and followed for 12 months from diagnosis, main CLVer study. Drug dosing was weight-based with incremental increases to full dosage. Side effect monitoring included serial measurements of pulse, blood pressure, liver enzymes, and electrocardiograms (ECGs). At study end, participants were enrolled in an observational extension study (CLVerEx), which is ongoing. No study drug is provided during the extension, but participants may use verapamil if prescribed by their diabetes care team. Results: Overall rates of adverse events were low and comparable between verapamil and placebo groups. There was no difference in the frequency of liver function abnormalities. Three CLVer participants reduced or discontinued medication due to asymptomatic ECG changes. One CLVerEx participant (18 years old), treated with placebo during CLVer, who had not had a monitoring ECG, experienced complete AV block with a severe hypotensive episode 6 weeks after reaching his maximum verapamil dose following an inadvertent double dose on the day of the event. Conclusions: The use of verapamil in youth newly-diagnosed with T1D appears generally safe and well tolerated with appropriate monitoring. We strongly recommend monitoring for potential side effects including an ECG at screening and an additional ECG once full dosage is reached.ClinicalTrials.gov number: NCT04233034.

17.
J Diabetes Sci Technol ; 17(4): 935-942, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35473359

RESUMO

BACKGROUND: We investigated the potential benefits of automated insulin delivery (AID) among individuals with type 1 diabetes (T1D) in sub-populations of baseline device use determined by continuous glucose monitor (CGM) use status and insulin delivery via multiple daily injections (MDI) or insulin pump. MATERIALS AND METHODS: In a six-month randomized, multicenter trial, 168 individuals were assigned to closed-loop control (CLC, Control-IQ, Tandem Diabetes Care), or sensor-augmented pump (SAP) therapy. The trial included a two- to eight-week run-in phase to train participants on study devices. The participants were stratified into four subgroups: insulin pump and CGM (pump+CGM), pump-only, MDI and CGM (MDI+CGM), and MDI users without CGM (MDI-only) users. We compared glycemic outcomes among four subgroups. RESULTS: At baseline, 61% were pump+CGM users, 18% pump-only users, 10% MDI+CGM users, and 11% MDI-only users. Mean time in range 70-180 mg/dL (TIR) improved from baseline in the four subgroups using CLC: pump+CGM, 62% to 73%; pump-only, 61% to 70%; MDI+CGM, 54% to 68%; and MDI-only, 61% to 69%. The reduction in time below 70 mg/dL from baseline was comparable among the four subgroups. No interaction effect was detected with baseline device use for TIR (P = .67) or time below (P = .77). On the System Usability Questionnaire, scores were high at 26 weeks for all subgroups: pump+CGM: 87.2 ± 12.1, pump-only: 89.4 ± 8.2, MDI+CGM 87.2 ± 9.3, MDI: 78.1 ± 15. CONCLUSIONS: There was a consistent benefit in patients with T1D when using CLC, regardless of baseline insulin delivery modality or CGM use. These data suggest that this CLC system can be considered across a wide range of patients.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes , Automonitorização da Glicemia , Glicemia , Insulina , Insulina Regular Humana/uso terapêutico , Sistemas de Infusão de Insulina
18.
Endocr Rev ; 44(2): 254-280, 2023 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-36066457

RESUMO

The significant and growing global prevalence of diabetes continues to challenge people with diabetes (PwD), healthcare providers, and payers. While maintaining near-normal glucose levels has been shown to prevent or delay the progression of the long-term complications of diabetes, a significant proportion of PwD are not attaining their glycemic goals. During the past 6 years, we have seen tremendous advances in automated insulin delivery (AID) technologies. Numerous randomized controlled trials and real-world studies have shown that the use of AID systems is safe and effective in helping PwD achieve their long-term glycemic goals while reducing hypoglycemia risk. Thus, AID systems have recently become an integral part of diabetes management. However, recommendations for using AID systems in clinical settings have been lacking. Such guided recommendations are critical for AID success and acceptance. All clinicians working with PwD need to become familiar with the available systems in order to eliminate disparities in diabetes quality of care. This report provides much-needed guidance for clinicians who are interested in utilizing AIDs and presents a comprehensive listing of the evidence payers should consider when determining eligibility criteria for AID insurance coverage.


Assuntos
Diabetes Mellitus Tipo 1 , Insulina , Humanos , Insulina/uso terapêutico , Hipoglicemiantes/uso terapêutico , Consenso , Glicemia , Automonitorização da Glicemia
19.
Diabetes Technol Ther ; 24(8): 588-591, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35020488

RESUMO

Using a closed-loop system significantly improves time in range (TIR) 70-180 mg/dL in patients with type 1 diabetes (T1D). In a 6-month RCT, 112 subjects were randomly assigned to closed-loop control (Tandem Control-IQ) after obtaining 2 weeks of baseline Continuous glucose monitoring (CGM) data from sensor-augmented pump therapy. We compared glycemic outcomes from baseline to end of study among subgroups classified by baseline HbA1c levels. All HbA1c subgroups showed an improvement in TIR due to reduction of both hyperglycemia and hypoglycemia. Those with HbA1c <6.5% improved mostly by reducing nocturnal hypoglycemia due to the automated basal insulin adjustments. Those with HbA1c ≥8.5% improved mostly by reducing daytime and nocturnal hyperglycemia due to both automated basal insulin adjustments and correction boluses during the day. There does not appear to be any reason to exclude individuals with T1D from automated insulin delivery based on their HbA1c. Clinical Trial Identifier: NCT03563313.


Assuntos
Diabetes Mellitus Tipo 1 , Hiperglicemia , Hipoglicemia , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Humanos , Hiperglicemia/tratamento farmacológico , Hiperglicemia/prevenção & controle , Hipoglicemia/induzido quimicamente , Hipoglicemia/tratamento farmacológico , Hipoglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina
20.
Diabetes Care ; 45(1): 186-193, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34794973

RESUMO

OBJECTIVE: Achieving optimal glycemic control for many individuals with type 1 diabetes (T1D) remains challenging, even with the advent of newer management tools, including continuous glucose monitoring (CGM). Modern management of T1D generates a wealth of data; however, use of these data to optimize glycemic control remains limited. We evaluated the impact of a CGM-based decision support system (DSS) in patients with T1D using multiple daily injections (MDI). RESEARCH DESIGN AND METHODS: The studied DSS included real-time dosing advice and retrospective therapy optimization. Adults and adolescents (age >15 years) with T1D using MDI were enrolled at three sites in a 14-week randomized controlled trial of MDI + CGM + DSS versus MDI + CGM. All participants (N = 80) used degludec basal insulin and Dexcom G5 CGM. CGM-based and patient-reported outcomes were analyzed. Within the DSS group, ad hoc analysis further contrasted active versus nonactive DSS users. RESULTS: No significant differences were detected between experimental and control groups (e.g., time in range [TIR] +3.3% with CGM vs. +4.4% with DSS). Participants in both groups reported lower HbA1c (-0.3%; P = 0.001) with respect to baseline. While TIR may have improved in both groups, it was statistically significant only for DSS; the same was apparent for time spent <60 mg/dL. Active versus nonactive DSS users showed lower risk of and exposure to hypoglycemia with system use. CONCLUSIONS: Our DSS seems to be a feasible option for individuals using MDI, although the glycemic benefits associated with use need to be further investigated. System design, therapy requirements, and target population should be further refined prior to use in clinical care.


Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Adulto , Glicemia , Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS