Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 22(1): 4, 2021 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-33397350

RESUMO

BACKGROUND: Extended scope physiotherapists (ESP) are increasingly supplementing orthopaedic surgeons (OS) in diagnosing patients with musculoskeletal disorders. Studies have reported satisfactory diagnostic and treatment agreement between ESPs and OSs, but methodological study quality is generally low, and only few studies have evaluated inter-professional collaboration. Our aims were: 1) to evaluate agreement on diagnosis and treatment plan between ESPs and OSs examining patients with shoulder disorders, 2) to explore and evaluate their inter-professional collaboration. METHODS: 1) In an orthopaedic outpatient shoulder clinic, 69 patients were examined independently twice on the same day by an ESP and an OS in random order. Primary and secondary diagnoses (nine categories) and treatment plan (five categories, combinations allowed) were registered by each professional and compared. Percentage of agreement and kappa-values were calculated. 2) Two semi-structured focus-group interviews were performed with ESPs and OSs, respectively. Interviews were based on the theoretical concept of Relational Coordination, encompassing seven dimensions of communication and relationship among professionals. A thematic analysis was conducted. RESULTS: 1) Agreement on primary diagnosis was 62% (95% CI: [50; 73]). ESPs and OSs agreed on the combination of diagnoses in 79% (95% CI: [70; 89]) of the cases. Partial diagnostic agreement (one professional's primary diagnosis was also registered as either primary or secondary diagnosis by the other) was 96% (95% CI: [91; 100]). Across treatment categories, agreement varied between 68% (95% CI: [57; 79]) and 100%. In 43% (95% CI: [31; 54]) of the cases, ESP and OS had full concordance between treatment categories chosen, while they agreed on at least one recommendation in 96% (95% CI: [91; 100]). 2) Positive statements of all dimensions of relational coordination were found. Three themes especially important in the inter-professional collaboration emerged: Close communication, equal and respectful relationship and professional skills. CONCLUSIONS: In the majority of cases, the ESP and OS registered the same or partly the same diagnosis and treatment plan. Indications of a high relational coordination implying a good inter-professional collaboration were found. Our results support that ESPs and OSs can share the task of examining selected patients with shoulder disorders in an orthopaedic clinic. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03343951 . Registered 10 November 2017.


Assuntos
Cirurgiões Ortopédicos , Ortopedia , Fisioterapeutas , Humanos , Pacientes Ambulatoriais , Ombro
2.
Acta Orthop ; 89(3): 345-350, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29537342

RESUMO

Background and purpose - It is unclear whether previous osteosynthesis is a risk factor for inferior outcome following shoulder arthroplasty for a proximal humeral fracture. We used data from the Danish Shoulder Arthroplasty Registry (DSR) to examine this question. Patients and methods - All 285 patients treated with a shoulder arthroplasty after failed osteosynthesis of a proximal humeral fracture reported to DSR from 2006 to 2013 were included. Each case was matched with 2 controls (570) treated with a primary shoulder arthroplasty for an acute proximal humeral fracture. Patient reported outcome was assessed using the Western Ontario Osteoarthritis of the Shoulder index (WOOS) and the relative risk of revision was reported. Results - The mean WOOS was 46 (SD 25) for a shoulder arthroplasty after failed osteosynthesis and 52 (27) after a primary shoulder arthroplasty. The relative risk of revision for a shoulder arthroplasty after failed osteosynthesis was 2 with a primary arthroplasty for fracture as reference. In a separate analysis of patients treated by locking plate the mean WOOS was 46 (24), with a relative risk of revision at 1.5 with a primary arthroplasty as reference. Interpretation - Compared with primary arthroplasty for proximal humeral fracture, we found an inferior patient-reported outcome and a substantial risk of revision for patients treated with a shoulder arthroplasty after failed osteosynthesis for a proximal humeral fracture. The risk and burdens of additional surgery should be accounted for when deciding on the primary surgical procedure.


Assuntos
Artroplastia do Ombro , Fixação Interna de Fraturas , Reoperação , Fraturas do Ombro/cirurgia , Idoso , Dinamarca , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Estudos Retrospectivos , Fatores de Risco , Falha de Tratamento
3.
Clin Orthop Relat Res ; 475(2): 442-451, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27554268

RESUMO

BACKGROUND: We previously introduced a manual surgical technique that makes small perforations (cracks) through the sclerotic bone shell that typically forms during the process of aseptic loosening ("crack" revision technique). Perforating just the shell (without violating the proximal cortex) can maintain overall bone continuity while allowing marrow and vascular elements to access the implant surface. Because many revisions require bone graft to fill defects, we wanted to determine if bone graft could further increase implant fixation beyond what we have experimentally shown with the crack technique alone. Also, because both titanium (Ti6Al4V) and hydroxyapatite (HA) implant surfaces are used in revisions, we also wanted to determine their relative effectiveness in this model. QUESTIONS/PURPOSES: We hypothesized that both (1) allografted plasma-sprayed Ti6Al4V; and (2) allografted plasma-sprayed HA-coated implants inserted with a crack revision technique have better fixation compared with a noncrack revision technique in each case. METHODS: Under approval from our Institutional Animal Care and Use Committee, a female canine animal model was used to evaluate the uncemented revision technique (crack, noncrack) using paired contralateral implants while implant surface (Ti6Al4V, HA) was qualitatively compared between the two (unpaired) series. All groups received bone allograft tightly packed around the implant. This revision model includes a cylindrical implant pistoning 500 µm in a 0.75-mm gap, with polyethylene particles, for 8 weeks. This engenders a bone and tissue response representative of the metaphyseal cancellous region of an aseptically loosened component. At 8 weeks, the original implants were revised and followed for an additional 4 weeks. Mechanical fixation was assessed by load, stiffness, and energy to failure when loaded in axial pushout. Histomorphometry was used to determine the amount and location of bone and fibrous tissue in the grafted gap. RESULTS: The grafted crack revision improved mechanical shear strength, stiffness, and energy to failure (for Ti6Al4V 27- to 69-fold increase and HA twofold increases). The histomorphometric analysis demonstrated primarily fibrous membrane ongrowth and in the gap for the allografted Ti6Al4V noncrack revisions. For allografted HA noncrack revisions, bone ongrowth at the implant surface was observed, but fibrous tissue also was present in the inner gap. Although both Ti6Al4V and HA surfaces showed improved fixation with grafted crack revision, and Ti6Al4V achieved the highest percent gain, HA demonstrated the strongest overall fixation. CONCLUSIONS: The results of this study suggest that novel osteoconductive or osteoinductive coatings and bone graft substitutes or tissue-engineered constructs may further improve bone-implant fixation with the crack revision technique but require evaluation in a rigorous model such as presented here. CLINICAL RELEVANCE: This experimental study provides data on which to base clinical trials aimed to improve fixation of revision implants. Given the multifactorial nature of complex human revisions, such a protocoled clinical study is required to determine the clinical applicability of this approach.


Assuntos
Artroplastia/métodos , Transplante Ósseo/métodos , Durapatita , Titânio , Animais , Substitutos Ósseos , Materiais Revestidos Biocompatíveis , Cães , Feminino , Modelos Animais , Osseointegração , Reoperação
4.
Acta Orthop ; 87(sup363): 1-5, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28271925

RESUMO

The combination of modern interventional and preventive medicine has led to an epidemic of ageing. While this phenomenon is a positive consequence of an improved lifestyle and achievements in a society, the longer life expectancy is often accompanied by decline in quality of life due to musculoskeletal pain and disability. The Aarhus Regenerative Orthopaedics Symposium (AROS) 2015 was motivated by the need to address regenerative challenges in an ageing population by engaging clinicians, basic scientists, and engineers. In this position paper, we review our contemporary understanding of societal, patient-related, and basic science-related challenges in order to provide a reasoned roadmap for the future to deal with this compelling and urgent healthcare problem.


Assuntos
Envelhecimento/fisiologia , Sistema Musculoesquelético/fisiopatologia , Medicina Regenerativa/métodos , Animais , Comorbidade , Modelos Animais de Doenças , Humanos , Regeneração/fisiologia
5.
Acta Orthop ; 83(4): 411-9, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22880714

RESUMO

BACKGROUND AND PURPOSE: Intermittent administration of parathyroid hormone (PTH) has an anabolic effect on bone, as confirmed in human osteoporosis studies, distraction osteogenesis, and fracture healing. PTH in rat models leads to improved fixation of implants in low-density bone or screw insertion transcortically. MATERIAL AND METHODS: We examined the effect of human PTH (1-34) on the cancellous osseointegration of unloaded implants inserted press-fit in intact bone of higher animal species. 20 dogs were randomized to treatment with human PTH (1-34), 5 µg/kg/day subcutaneously, or placebo for 4 weeks starting on the day after insertion of a cylindrical porous coated plasma-sprayed titanium alloy implant in the proximal metaphyseal cancellous bone of tibia. Osseointegration was evaluated by histomorphometry and fixation by push-out test to failure. RESULTS: Surface fraction of woven bone at the implant interface was statistically significantly higher in the PTH group by 1.4 fold with (median (interquartile range) 15% (13-18)) in the PTH group and 11% (7-13) in control. The fraction of lamellar bone was unaltered. No significant difference in bone or fibrous tissue was observed in the circumferential regions of 0-500, 500-1,000, and 1,000-2,000 µm around the implant. Mechanically, the implants treated with PTH showed no significant differences in total energy absorption, maximum shear stiffness, or maximum shear strength. INTERPRETATION: Intermittent treatment with PTH (1-34) improved histological osseointegration of a prosthesis inserted press-fit at surgery in cancellous bone, with no additional improvement of the initial mechanical fixation at this time point.


Assuntos
Osseointegração/efeitos dos fármacos , Hormônio Paratireóideo/administração & dosagem , Próteses e Implantes , Desenho de Prótese , Tíbia/cirurgia , Ligas/uso terapêutico , Animais , Fenômenos Biomecânicos , Materiais Revestidos Biocompatíveis , Modelos Animais de Doenças , Cães , Esquema de Medicação , Humanos , Injeções Subcutâneas , Masculino , Osseointegração/fisiologia , Fotomicrografia , Implantação de Prótese/métodos , Distribuição Aleatória , Valores de Referência , Resistência ao Cisalhamento , Tíbia/patologia , Titânio/uso terapêutico , Resultado do Tratamento
6.
Dan Med J ; 69(7)2022 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-35781131

RESUMO

INTRODUCTION: Measuring and developing patient safety culture (PSC) is a focal point in creating a highly reliable organisation, and patient safety is the cornerstone of quality healthcare. The purpose of this study was to describe PSC in an elective orthopaedic surgery centre in Denmark. METHODS: A total of 445 healthcare workers were invited to participate. A cross-sectional study design using the Safety Attitudes Questionnaire (SAQ) was applied. RESULTS: A total of 356 invitees (80%) answered the SAQ. The proportion of employees with a positive perception of the PSC was above the anticipated 60% threshold in five out of six dimensions. Perceptions of PSC varied by gender across four of six dimensions. Thus, significantly more female than male participants had a positive perception of the PSC. A significant variation was observed in the proportion of employees with a positive perception of PSC at the unit level except for teamwork climate and stress recognition. CONCLUSIONS: This is the first Danish study of PSC in an elective orthopaedic surgical setting. Across dimensions, % positive were more favourable than reported in the international literature. FUNDING: none. TRIAL REGISTRATION: not relevant.


Assuntos
Procedimentos Ortopédicos , Ortopedia , Atitude do Pessoal de Saúde , Estudos Transversais , Dinamarca , Feminino , Humanos , Masculino , Cultura Organizacional , Segurança do Paciente , Gestão da Segurança
7.
Calcif Tissue Int ; 88(4): 294-303, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21253714

RESUMO

Parathyroid hormone (PTH) administered intermittently is a bone-building peptide. In joint replacements, implants are unavoidably surrounded by gaps despite meticulous surgical technique and osseointegration is challenging. We examined the effect of human PTH(1-34) on implant fixation in an experimental gap model. We inserted cylindrical (10 × 6 mm) porous coated titanium alloy implants in a concentric 1-mm gap in normal cancellous bone of proximal tibia in 20 canines. Animals were randomized to treatment with PTH(1-34) 5 µg/kg daily. After 4 weeks, fixation was evaluated by histomorphometry and push-out test. Bone volume was increased significantly in the gap. In the outer gap (500 µm), the bone volume fraction median (interquartile range) was 27% (20-37%) for PTH and 10% (6-14%) for control. In the inner gap, the bone volume fraction was 33% (26-36%) for PTH and 13% (11-18%) for control. At the implant interface, the bone fraction improved with 16% (11-20%) for PTH and 10% (7-12%) (P = 0.07) for control. Mechanical implant fixation was improved for implants exposed to PTH. For PTH, median (interquartile range) shear stiffness was significantly higher (PTH 17.4 [12.7-39.7] MPa/mm and control 8.8 [3.3-12.4] MPa/mm) (P < 0.05). Energy absorption was significantly enhanced for PTH (PTH 781 [595-1,198.5] J/m(2) and control 470 [189-596] J/m(2)). Increased shear strength was observed but was not significant (PTH 3.0 [2.6-4.9] and control 2.0 [0.9-3.0] MPa) (P = 0.08). Results show that PTH has a positive effect on implant fixation in regions where gaps exist in the surrounding bone. With further studies, PTH may potentially be used clinically to enhance tissue integration in these challenging environments.


Assuntos
Hormônio Paratireóideo/uso terapêutico , Porosidade , Ligas , Animais , Fenômenos Biomecânicos , Osso e Ossos/patologia , Materiais Revestidos Biocompatíveis/farmacologia , Cães , Hormônios/metabolismo , Masculino , Teste de Materiais , Ortopedia/métodos , Próteses e Implantes , Estresse Mecânico , Tíbia/patologia
8.
Acta Radiol ; 51(2): 187-93, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20144145

RESUMO

BACKGROUND: Reliable assessment of hip dysplasia and osteoarthritis is crucial in young adults who may benefit from joint-preserving surgery. PURPOSE: To investigate the variability of different methods for diagnostic assessment of hip dysplasia and osteoarthritis. MATERIAL AND METHODS: By each of four observers, two assessments were done by vision and two by angle construction. For both methods, the intra- and interobserver variability of center-edge and acetabular index angle assessment were analyzed. The observers' ability to diagnose hip dysplasia and osteoarthritis were assessed. All measures were compared to those made on computed tomography scan. RESULTS: Intra- and interobserver variability of angle assessment was less when angles were drawn compared with assessment by vision, and the observers' ability to diagnose hip dysplasia improved when angles were drawn. Assessment of osteoarthritis in general showed poor agreement with findings on computed tomography scan. CONCLUSION: We recommend that angles always should be drawn for assessment of hip dysplasia on pelvic radiographs. Given the inherent variability of diagnostic assessment of hip dysplasia, a computed tomography scan could be considered in patients with relevant hip symptoms and a center-edge angle between 20 degrees and 30 degrees . Osteoarthritis should be assessed by measuring the joint space width or by classifying the Tönnis grade as either 0-1 or 2-3.


Assuntos
Luxação Congênita de Quadril/diagnóstico por imagem , Osteoartrite do Quadril/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Feminino , Luxação Congênita de Quadril/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Osteoartrite do Quadril/patologia , Interpretação de Imagem Radiográfica Assistida por Computador
9.
Clin Orthop Relat Res ; 468(3): 867-74, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19763718

RESUMO

BACKGROUND: Long-term survival of uncemented total joint replacements relies on osseointegration. With reduced bone stock impacted morselized allograft enhances early implant fixation but is subject to resorption. PURPOSE: We therefore asked whether soaking morselized allograft in different concentrations of bisphosphonate before impaction would enhance fixation. METHODS: In each of 10 dogs, we implanted four unloaded titanium implants surrounded by a 2.5-mm gap into the proximal humerus, two implants in each humerus. The gap was filled with impacted morselized allograft soaked in saline or a low-, middle-, or high-dose bisphosphonate solution (0.005, 0.05, or 0.5 mg zoledronate/mL). At 4 weeks, the implants were evaluated by histomorphometric analysis and mechanical pushout test. RESULTS: The low dose of zoledronate increased new bone formation in the allograft but the high dose decreased new bone formation. The high dose of zoledronate resulted in the greatest inhibition of allograft resorption, whereas the low dose of zoledronate resulted in the lowest inhibition of allograft resorption. Implants surrounded allograft soaked in the low dose of zoledronate or saline had better fixation for all three mechanical parameters compared with implants surrounded by allograft soaked in the middle or high dose of zoledronate. CONCLUSIONS: These data suggest bisphosphonate may enhance osseointegration of allografted implants and emphasize the need for preclinical testing of antiresorptive therapies.


Assuntos
Artroplastia de Substituição/métodos , Conservadores da Densidade Óssea/administração & dosagem , Transplante Ósseo , Difosfonatos/administração & dosagem , Imidazóis/administração & dosagem , Osseointegração/efeitos dos fármacos , Animais , Fenômenos Biomecânicos , Modelos Animais de Doenças , Cães , Relação Dose-Resposta a Droga , Feminino , Úmero/efeitos dos fármacos , Úmero/patologia , Úmero/cirurgia , Projetos Piloto , Próteses e Implantes , Desenho de Prótese , Titânio/química , Transplante Homólogo , Ácido Zoledrônico
10.
J Orthop Res ; 38(3): 510-522, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31595550

RESUMO

Complex radial head fracture and elbow instability can be treated with radial head arthroplasty. Good clinical results have been described after this surgical treatment. However, the revision and complication rate reported in the literature is concerning. This might be due to altered kinematics after radial head arthroplasty. Eight human native elbows were examined with dynamic radiostereometric analysis and compared with a radial head arthroplasty. Translations of the radial head in the x-, y-, and z-directions relative to the humerus and the ulna were measured. The radiocapitellar joint pressure was measured using a pressure sensor. The tension within the interosseous membrane was measured using a custom-made strain gauge. After radial head arthroplasty, the radial head was displaced approximately 1.8 mm medially and 1.4 mm distally at the starting point. During unloaded flexion motion the difference in all translations between the native radial head and the radial head arthroplasty was less than 1 mm (95% confidence interval [CI] ± 0.5 mm) (p = 0.001). With loading the difference was less than 1.5 mm (95% CI ± 1.5 mm) (p = 0.001). The mean difference in radiocapitellar joint contact pressure was less than 0.30 MPa (95% CI ± 0.40 MPa) (p = 0.001) during unloaded flexion motion. There were only submillimetre kinematic changes and small changes in joint pressure and interosseous membrane tension after the insertion of a radial head arthroplasty in an experimental setting. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 38:510-522, 2020.


Assuntos
Artroplastia/métodos , Articulação do Cotovelo/fisiologia , Membrana Interóssea/patologia , Fraturas do Rádio/cirurgia , Rádio (Anatomia)/fisiologia , Rádio (Anatomia)/cirurgia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Dinamarca , Articulação do Cotovelo/cirurgia , Feminino , Humanos , Úmero/cirurgia , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Pressão , Estresse Mecânico , Tomografia Computadorizada por Raios X
11.
Clin Orthop Relat Res ; 467(10): 2638-43, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19229662

RESUMO

The crack procedure is a surgical technique for preparing the implant cavity at revision of loose joint replacement components. It disrupts the neocortical bone shell that typically forms around the cavity. Using an animal model, we compared the crack technique with reaming. Twenty micromotion implants were inserted bilaterally into the knees of 10 dogs according to our revision protocol, allowing formation of a standardized revision cavity (loose implant, fibrous tissue, and sclerotic bone rim). Eight weeks later we performed revision surgery. On the control side, in which the neocortex was removed, the cavity was reamed. On the intervention side, in which the neocortex was perforated but left in situ, the cavity was cracked. For revision we used non-motioning hydroxyapatite (HA)-coated, plasma-sprayed titanium implants. Observation after revision was 4 weeks. The implants revised by the crack technique had better mechanical fixation in all mechanical parameters by the push-out test. The crack revisions also provided more new bone formation around the implants compared with the reamed revisions but had no effect on new bone ongrowth. The data suggest using this bone-sparing technique may be superior to reaming in terms of achieving improved early implant fixation of uncemented HA-coated revision implants.


Assuntos
Artroplastia do Joelho , Materiais Revestidos Biocompatíveis , Durapatita , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho , Titânio , Animais , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/métodos , Cães , Feminino , Fibrose , Instabilidade Articular/etiologia , Instabilidade Articular/patologia , Instabilidade Articular/fisiopatologia , Articulação do Joelho/patologia , Articulação do Joelho/fisiopatologia , Teste de Materiais , Modelos Animais , Osseointegração , Desenho de Prótese , Reoperação , Esclerose
12.
Biomaterials ; 29(19): 2915-22, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18407348

RESUMO

BMPs stimulate new bone formation, but may also accelerate bone resorption. We added rhBMP-2 and pamidronate to morselized bone allograft packed around uncemented HA-coated and non-coated porous Ti implants in sixteen dogs. Each dog received four implants where the allograft was added (1) nothing, (2) BMP, (3) BP, and (4) BMP+BP. After four weeks, the untreated control implants had better mechanical fixation than all other treatment groups. The rhBMP-2-treated group had abundant formation of new bone on and around the implant. However, almost all allografts were resorbed, rendering the implant mechanically unstable. In the pamidronate-treated group the allograft was preserved, but the implants were covered by fibrous tissue and there was almost no new bone formation. This was also the case for the combined BMP+BP group, although fibrous tissue was absent on these implants. The HA-coated implants had more than twice as good mechanical fixation and improved osseointegration compared to the corresponding Ti implants. RhBMP-2 raised the total metabolic turnover of bone within the allograft with a net negative result on implant fixation. Pamidronate virtually blocked bone metabolism, also when combined with rhBMP-2. The results warrant a conservative approach and emphasize the importance of identifying a therapeutic window for these substances prior to clinical use.


Assuntos
Proteínas Morfogenéticas Ósseas/administração & dosagem , Transplante Ósseo , Difosfonatos/administração & dosagem , Ácido Hialurônico/química , Próteses e Implantes , Proteínas Recombinantes/administração & dosagem , Titânio/química , Fator de Crescimento Transformador beta/administração & dosagem , Animais , Proteína Morfogenética Óssea 2 , Cães , Humanos , Pamidronato , Transplante Homólogo
13.
Acta Orthop ; 79(6): 777-84, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19085494

RESUMO

BACKGROUND AND PURPOSE: Periacetabular osteotomy is the treatment of choice in young adults with hip dysplasia. Patient morbidity and surgical outcome may depend on the choice of surgical approach. We compared the outcome of a new minimally invasive approach to that of the frequently used "classic" ilioinguinal approach. PATIENTS AND METHODS: We retrospectively evaluated our experience with the ilioinguinal and minimally invasive approaches, which were used in successive time periods at our institution between December 1998 and February 2007 (n=263). Intraoperative and early postoperative outcome factors together with analysis of hip joint survival were compared in well-defined study groups. RESULTS: In the minimally invasive and ilioinguinal groups respectively, the median (interquartile range) intraoperative blood loss was 250 (200-350) mL and 500 (350-700) mL (p<0.001), the mean (95% CI) hemoglobin reduction was 2.0 (1.9-2.1) mmol/L and 2.5 (2.4-2.7) mmol/L (p<0.001), transfusion was required following 4% and 18% of the procedures (p<0.001), and the median (interquartile range) duration of surgery was 70 (60-75) min and 100 (80-120) min (p<0.001). Median (interquartile range) postoperative center-edge and acetabular index angles were 33 (30-36) and 2 (0-6), respectively, in the minimally invasive group and 31 (25-35) and 9 (1-14) in the ilioinguinal group. There were no cases of moderate or severe complications in the minimally invasive group and 3 cases of arterial thrombosis in the ilioinguinal group (3%). At follow-up of 5 years, the hip joint survival rates were 97% in the minimally invasive group and 93% in the ilioinguinal group. INTERPRETATION: Given the accumulated experience of the surgeon, the outcome of the minimally invasive approach compares favorably with that of the ilioinguinal approach, and the results support continued use of the minimally invasive approach for periacetabular osteotomy. Using this approach, we did not encounter any complications and acetabular reorientation was not compromized.


Assuntos
Acetábulo/cirurgia , Luxação Congênita de Quadril/cirurgia , Luxação do Quadril/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Osteotomia/métodos , Acetábulo/anormalidades , Adulto , Feminino , Seguimentos , Luxação do Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/diagnóstico por imagem , Humanos , Ílio/cirurgia , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Osteotomia/efeitos adversos , Avaliação de Resultados em Cuidados de Saúde , Falha de Prótese , Radiografia , Estudos Retrospectivos , Resultado do Tratamento
14.
Acta Orthop ; 79(6): 841-50, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19085504

RESUMO

BACKGROUND AND PURPOSE: We studied whether osseointegration and fixation of plasma-sprayed titanium implants grafted with beta-TCP granules (Ossaplast) can be improved by adding an osteogenic signal (Colloss E). The results were compared to implants grafted with fresh frozen morselized allograft with and without the Colloss E device. METHODS: 4 porous-coated Ti implants were placed in the proximal humeri in each of 10 dogs. All implants were surrounded by a 2.5-mm defect, which was grafted with: (A) beta-TCP, (B) beta-TCP+20 mg Colloss E, (C) allograft, or (D) allograft+20 mg Colloss E. The observation time was 4 weeks. RESULTS: Mechanical testing showed that the beta-TCP group with Colloss E was twice as well fixed as the control group grafted with beta-TCP granules alone, and comparable to both allograft groups. We found that every control implant in the beta-TCP grafted group was covered by a dense fibrous membrane. No fibrous tissue was seen in the beta-TCP group augmented with Colloss. These implants were well osseointegrated, with new bone covering 10-25% of the implant surface. Both treated groups had increased graft resorption compared to their respective control groups. Colloss E had no effect on new bone formation or fibrous tissue reduction around the allografted implants. INTERPRETATION: The Colloss E device improved early osseointegration of implants grafted with beta-TCP granules and increased their mechanical implant fixation to the level of allografted implants. The experiment indicates that ceramic bone substitutes may be a viable alternative to allograft when combined with an osteogenic signal such as Colloss E.


Assuntos
Substitutos Ósseos , Transplante Ósseo , Implantes Experimentais , Animais , Transplante Ósseo/métodos , Cerâmica , Cães , Úmero/patologia , Úmero/fisiologia , Osseointegração/fisiologia , Estresse Mecânico , Titânio , Transplante Homólogo
15.
J Orthop Res ; 25(4): 432-41, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17177297

RESUMO

Bone compaction has been shown to increase initial implant fixation. Furthermore, bone compaction creates a peri-implant zone of autograft that exerts osteoconductive properties. We have previously shown that locally applied bisphosphonate (alendronate) at 4-week observation can preserve the autograft generated by bone compaction. We now investigate whether the increased amount of autograft, seen at 4 weeks, can increase implant osseointegration and biomechanical fixation. Porous-coated titanium implants were bilaterally inserted with bone compaction into the proximal part of tibia of 10 dogs. On the right side, local bisphosphonate was injected into the bone cavity prior to bone compaction immediately prior to implant insertion. On the left side, saline was used as control. Observation period was 12 weeks. Locally applied bisphosphonate significantly increased biomechanical implant fixation (approximately twofold), bone-to-implant contact (1.2-fold), and peri-implant bone volume fraction (2.3-fold). This study indicates that local alendronate treatment can increase early implant osseointegration and biomechanical fixation of implants inserted by use of bone compaction. Long term effects remain unknown.


Assuntos
Alendronato/farmacologia , Difosfonatos/farmacologia , Osseointegração/efeitos dos fármacos , Próteses e Implantes , Titânio , Alendronato/administração & dosagem , Animais , Fenômenos Biomecânicos , Difosfonatos/administração & dosagem , Cães , Feminino , Fixadores Internos , Osseointegração/fisiologia , Tíbia/efeitos dos fármacos , Tíbia/fisiologia
16.
Biomaterials ; 26(17): 3521-6, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15621242

RESUMO

Early bone ongrowth is known to increase primary implant fixation and reduce the risk of early implant failure. Arg-Gly-Asp (RGD) peptide has been identified as playing a key role in osteoblast adhesion and proliferation on various surfaces. The aim for this study is to evaluate the effect of RGD peptide coating on the bony fixation of orthopaedic implants, to justify its further evaluation in clinical applications. Sixteen unloaded cylindrical plasma sprayed Ti6Al4V implants coated with cyclic RGD peptide were inserted as press-fit in the proximal tibia of 8 mongrel dogs for 4 weeks. Uncoated control implants were inserted in the contralateral tibia. Results were evaluated by histomorphometry and mechanical push-out test. A significant two-fold increase was observed in bone ongrowth for RGD-coated implants. Also, fibrous tissue ongrowth was significantly reduced for RGD-coated implants. Bone volume was significantly increased in a 0-100 microm zone around the implant. The increased bony anchorage resulted in moderate increases in mechanical fixation as apparent shear stiffness was significantly higher for RGD-coated implants. Increases in median ultimate shear strength and energy to failure were also observed. This study demonstrates that cyclic RGD coating increases early bony fixation of unloaded press-fit titanium implants.


Assuntos
Materiais Revestidos Biocompatíveis/farmacologia , Oligopeptídeos/farmacologia , Osseointegração/efeitos dos fármacos , Osteoblastos/efeitos dos fármacos , Osteoblastos/patologia , Tíbia/patologia , Titânio/química , Ligas , Animais , Adesão Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/química , Cães , Implantes Experimentais , Teste de Materiais , Oligopeptídeos/química , Osteogênese/efeitos dos fármacos , Resistência à Tração , Tíbia/efeitos dos fármacos , Tíbia/fisiopatologia , Tíbia/cirurgia
17.
J Biomed Mater Res A ; 75(2): 249-55, 2005 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-16106438

RESUMO

RGD (Arg-Gly-Asp) coating has been suggested to enhance implant fixation by facilitating the adhesion of osteogenic cells to implant surfaces. Orthopedic implants are unavoidably surrounded partly by gaps, and these regions represent a challenging environment for osseointegration. We examined the effects of cyclic RGD-coated implants on tissue integration and implant fixation in two cancellous bone-gap models. In canines, we inserted loaded RGD-coated implants with 0.75-mm gap (n = 8) and unloaded RGD-coated implants with 1.5-mm gap (n = 8) into the distal femur and proximal tibia, respectively. Control gap implants without RGD were inserted contralaterally. The titanium alloy (Ti-6Al-4V) implants were plasma sprayed and cylindrical. The observation period was 4 weeks and the fixation was evaluated by push-out test and histomorphometry. Mechanical implant fixation was improved for RGD-coated implants. Unloaded RGD-coated implants showed a significant increase in bone whereas both loaded and unloaded implants showed a significant reduction in fibrous tissue anchorage. The results are encouraging, because RGD had an overall positive effect on the fixation of titanium implants in regions where gaps exist with the surrounding bone. RGD peptide coatings can potentially be used to enhance tissue integration in these challenging environments.


Assuntos
Osso e Ossos/metabolismo , Materiais Revestidos Biocompatíveis/metabolismo , Implantes Experimentais , Oligopeptídeos/metabolismo , Osseointegração , Titânio/metabolismo , Animais , Osso e Ossos/citologia , Materiais Revestidos Biocompatíveis/química , Cães , Humanos , Teste de Materiais , Modelos Biológicos , Oligopeptídeos/química , Osteoblastos/citologia , Osteoblastos/metabolismo , Estresse Mecânico , Propriedades de Superfície , Titânio/química
18.
J Biomed Mater Res A ; 100(1): 188-94, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22021212

RESUMO

Joint replacements should be firmly anchored in vital bone to avoid early implant subsidence and late aseptic loosening. We investigated whether the fixation of orthopedic implants could be improved by adding an osteoinductive extract of lyophilized equine bone matrix proteins (Colloss E, Ossacur AG, Germany), between the implant and the surrounding bone. Eighteen uncemented HA-coated implants were inserted pairwise in the proximal tibia of nine dogs. All implants were surrounded by a 2 mm concentric defect. In each dog, the intervention implant was added 20 mg protein lyophilisate. The contralateral control implant was inserted untreated. After four weeks, the treated HA-coated implants had better mechanical fixation than the untreated control implants. The treated implants were better osseointegrated, there was more newly formed bone around these implants, and fibrous tissue was eliminated. The mechanical implant fixation had a strong positive correlation to new bone formation on and around the implant, and a strong negative correlation to fibrous tissue encapsulation. The results suggest that bone protein extracts such as the Colloss E device may augment early implant fixation of even HA-coated Ti implants and thereby reduce the risk of long-term failure. This may be particularly useful in revision arthroplasty with bone loss.


Assuntos
Matriz Óssea/metabolismo , Proteínas Morfogenéticas Ósseas/farmacologia , Colágeno/farmacologia , Fixação de Fratura , Hidroxiapatitas/farmacologia , Implantes Experimentais , Osseointegração/efeitos dos fármacos , Titânio/farmacologia , Animais , Osso e Ossos/efeitos dos fármacos , Osso e Ossos/patologia , Materiais Revestidos Biocompatíveis/farmacologia , Cães , Liofilização , Cavalos , Fenômenos Mecânicos/efeitos dos fármacos , Implantação de Prótese
19.
Open Orthop J ; 6: 371-5, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22962566

RESUMO

The use of bone grafting is a well-established way to enhance initial implant fixation in situations with reduced bone stock. Ceramic bone substitutes are inferior alternatives to autogenous or allogeneic bone graft. Improvement of bone graft substitutes is needed. We investigated whether biomechanical implant fixation and osseointegration of experimental implant grafted with ß-TCP granules (Conduit) could be improved by soaking the ß-TCP granules in bisphosphonate (zoledronate). In 10 dogs, a pair of titanium coated implants surrounded by a 2.5 mm gap was inserted into the proximal part of each tibia. The gap was grafted with ß-TCP granules either soaked with zoledronate or saline. At 12 weeks, the implants were evaluated with biomechanical push-out test and histomorphometrical analysis. We found that bisphosphonate increased one of the three biomechanical parameters, but found no difference in the amount of new bone or ß-TCP granules between the two treatment groups. This study indicates that local treatment of ß-TCP granules with zoledronate not only has the potential to increase implant fixation but also calls for further experimental research in order to optimize the dose of zoledronate.

20.
J Biomed Mater Res A ; 99(1): 9-15, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21793192

RESUMO

We compared early fixation of titanium implants grafted with impacted allograft bone or coralline hydroxyapatite (HA) granules (Pro Osteon 200) with and without the addition of concentrated bone marrow cells (BMC). Autologous bone marrow aspirate was centrifuged to increase the BMC concentration. Four nonloaded cylindrical, porous coated titanium implants with a circumferential gap of 2.3 mm were inserted in the proximal humeri of eight dogs. Coralline HA granules +/- BMC were impacted around the two implants on one side, and allograft +/- BMC was impacted around the contra lateral implants. Observation time was 4 weeks. The implants surrounded by allograft bone had a three-fold better fixation than the HA-grafted implants. The concentration of BMC after centrifugation was increased with a factor 2.1. The addition of BMC to either of the bone graft materials had no statistically significant effects on implant fixation. The allografted implants were well osseointegrated, whereas the HA-grafted implants were largely encapsulated in fibrous tissue. The addition of concentrated autologous BMCs to the graft material had no effect on implant fixation. The HA-grafted implants were poorly anchored compared with allografted implants, suggesting that coralline HA granules should be considered a bone graft extender rather than a bone graft substitute.


Assuntos
Células da Medula Óssea/citologia , Transplante de Medula Óssea , Substitutos Ósseos , Cerâmica , Hidroxiapatitas , Osseointegração , Próteses e Implantes , Titânio , Animais , Cães , Porosidade , Transplante Autólogo , Transplante Homólogo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa