Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 178
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Cephalalgia ; 44(5): 3331024241248837, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38796855

RESUMO

BACKGROUND: The development and approval of antibodies targeting calcitonin gene-related peptide or its receptor mark a revolutionary era for preventive migraine treatment. Real-world evidence sheds light on rare, stigmatized or overlooked side effects of these drugs. One of these potential side effects is sexual dysfunction. CASE REPORTS: We present two cases of one 42-year-old and one 45-year-old female patient with chronic migraine who both reported sexual dysfunction as a possible side effect of treatment with galcanezumab, a monoclonal antibody targeting calcitonin gene-related peptide. DISCUSSION: As calcitonin gene-related peptide is involved in vaginal lubrication as well as genital sensation and swelling, inhibiting the calcitonin gene-related peptide pathway may lead to sexual dysfunction as a potential side effect. CONCLUSION: Sexual dysfunction in female migraine patients might be a rare and overlooked side effect of monoclonal antibodies targeting the calcitonin gene-related peptide pathway. Considering the discomfort and stigma surrounding both migraine and sexual dysfunction, we advocate for an open attitude and awareness among clinicians toward such side effects.


Assuntos
Anticorpos Monoclonais Humanizados , Peptídeo Relacionado com Gene de Calcitonina , Transtornos de Enxaqueca , Disfunções Sexuais Fisiológicas , Humanos , Feminino , Transtornos de Enxaqueca/tratamento farmacológico , Pessoa de Meia-Idade , Peptídeo Relacionado com Gene de Calcitonina/antagonistas & inibidores , Adulto , Anticorpos Monoclonais Humanizados/efeitos adversos , Anticorpos Monoclonais Humanizados/uso terapêutico , Disfunções Sexuais Fisiológicas/induzido quimicamente , Antagonistas do Receptor do Peptídeo Relacionado ao Gene de Calcitonina/efeitos adversos , Antagonistas do Receptor do Peptídeo Relacionado ao Gene de Calcitonina/uso terapêutico , Anticorpos Monoclonais/efeitos adversos , Anticorpos Monoclonais/uso terapêutico
2.
Xenobiotica ; 54(2): 64-74, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38197324

RESUMO

Glioblastoma multiforme (GBM) is the most common primary brain tumour in adults. Available treatments have not markedly improved patient survival in the last twenty years. However, genomic investigations have showed that the PI3K pathway is frequently altered in this glioma, making it a potential therapeutic target.Paxalisib is a brain penetrant PI3K/mTOR inhibitor (mouse Kp,uu 0.31) specifically developed for the treatment of GBM. We characterised the preclinical pharmacokinetics and efficacy of paxalisib and predicted its pharmacokinetics and efficacious dose in humans.Plasma protein binding of paxalisib was low, with the fraction unbound ranging from 0.25 to 0.43 across species. The hepatic clearance of paxalisib was predicted to be low in mice, rats, dogs and humans, and high in monkeys, from hepatocytes incubations. The plasma clearance was low in mice, moderate in rats and high in dogs and monkeys. Oral bioavailability ranged from 6% in monkeys to 76% in rats.The parameters estimated from the pharmacokinetic/pharmacodynamic modelling of the efficacy in the subcutaneous U87 xenograft model combined with the human pharmacokinetics profile predicted by PBPK modelling suggested that a dose of 56 mg may be efficacious in humans. Paxalisib is currently tested in Phase III clinical trials.


Assuntos
Fosfatidilinositol 3-Quinases , Inibidores de Proteínas Quinases , Humanos , Ratos , Camundongos , Animais , Cães , Fosfatidilinositol 3-Quinases/metabolismo , Inibidores de Proteínas Quinases/farmacocinética , Inibidores de Fosfoinositídeo-3 Quinase/metabolismo , Encéfalo/metabolismo , Serina-Treonina Quinases TOR/metabolismo
3.
Eur Heart J ; 44(30): 2815-2828, 2023 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-37345664

RESUMO

Migraine is a chronic neurovascular disease with a complex, not fully understood pathophysiology with multiple causes. People with migraine suffer from recurrent moderate to severe headache attacks varying from 4 to 72 h. The prevalence of migraine is two to three times higher in women compared with men. Importantly, it is the most disabling disease in women <50 years of age due to a high number of years lived with disability, resulting in a very high global socioeconomic burden. Robust evidence exists on the association between migraine with aura and increased incidence of cardiovascular disease (CVD), in particular ischaemic stroke. People with migraine with aura have an increased risk of atrial fibrillation, myocardial infarction, and cardiovascular death compared with those without migraine. Ongoing studies investigate the relation between migraine and angina with non-obstructive coronary arteries and migraine patients with patent foramen ovale. Medication for the treatment of migraine can be preventative medication, such as beta-blockers, angiotensin-converting enzyme inhibitors/angiotensin receptor blockers, antiepileptics, antidepressants, some of the long-acting calcitonin gene-related peptide receptor antagonists, or monoclonal antibodies against calcitonin gene-related peptide or its receptor, or acute medication, such as triptans and calcitonin gene-related peptide receptor antagonists. However, these medications might raise concerns when migraine patients also have CVD due to possible (coronary) side effects. Specifically, knowledge gaps remain for the contraindication to newer treatments for migraine. All cardiologists will encounter patients with CVD and migraine. This state-of-the-art review will outline the basic pathophysiology of migraine and the associations between migraine and CVD, discuss current therapies, and propose future directions for research.


Assuntos
Isquemia Encefálica , Cardiologistas , Doenças Cardiovasculares , Forame Oval Patente , Transtornos de Enxaqueca , Enxaqueca com Aura , Acidente Vascular Cerebral , Masculino , Humanos , Feminino , Doenças Cardiovasculares/complicações , Doenças Cardiovasculares/epidemiologia , Enxaqueca com Aura/complicações , Enxaqueca com Aura/epidemiologia , Isquemia Encefálica/complicações , Antagonistas do Receptor do Peptídeo Relacionado ao Gene de Calcitonina , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/complicações , Transtornos de Enxaqueca/complicações , Transtornos de Enxaqueca/epidemiologia , Forame Oval Patente/complicações
4.
Radiology ; 307(4): e221922, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36975820

RESUMO

Background Several single-center studies found that high contralateral parenchymal enhancement (CPE) at breast MRI was associated with improved long-term survival in patients with estrogen receptor (ER)-positive and human epidermal growth factor receptor 2 (HER2)-negative breast cancer. Due to varying sample sizes, population characteristics, and follow-up times, consensus of the association is currently lacking. Purpose To confirm whether CPE is associated with long-term survival in a large multicenter retrospective cohort, and to investigate if CPE is associated with endocrine therapy effectiveness. Materials and Methods This multicenter observational cohort included women with unilateral ER-positive HER2-negative breast cancer (tumor size ≤50 mm and ≤three positive lymph nodes) who underwent MRI from January 2005 to December 2010. Overall survival (OS), recurrence-free survival (RFS), and distant RFS (DRFS) were assessed. Kaplan-Meier analysis was performed to investigate differences in absolute risk after 10 years, stratified according to CPE tertile. Multivariable Cox proportional hazards regression analysis was performed to investigate whether CPE was associated with prognosis and endocrine therapy effectiveness. Results Overall, 1432 women (median age, 54 years [IQR, 47-63 years]) were included from 10 centers. Differences in absolute OS after 10 years were stratified according to CPE tertile as follows: 88.5% (95% CI: 88.1, 89.1) in tertile 1, 85.8% (95% CI: 85.2, 86.3) in tertile 2, and 85.9% (95% CI: 85.4, 86.4) in tertile 3. CPE was independently associated with OS, with a hazard ratio (HR) of 1.17 (95% CI: 1.0, 1.36; P = .047), but was not associated with RFS (HR, 1.11; P = .16) or DRFS (HR, 1.11; P = .19). The effect of endocrine therapy on survival could not be accurately assessed; therefore, the association between endocrine therapy efficacy and CPE could not reliably be estimated. Conclusion High contralateral parenchymal enhancement was associated with a marginally decreased overall survival in patients with estrogen receptor-positive and human epidermal growth factor receptor 2-negative breast cancer, but was not associated with recurrence-free survival (RFS) or distant RFS. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Honda and Iima in this issue.


Assuntos
Neoplasias da Mama , Neoplasias de Mama Triplo Negativas , Humanos , Feminino , Pessoa de Meia-Idade , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/metabolismo , Receptores de Estrogênio , Estudos Retrospectivos , Neoplasias de Mama Triplo Negativas/patologia , Mama/diagnóstico por imagem , Mama/metabolismo , Prognóstico , Receptor ErbB-2/metabolismo , Imageamento por Ressonância Magnética/métodos , Intervalo Livre de Doença , Recidiva Local de Neoplasia/patologia
5.
J Cardiovasc Electrophysiol ; 34(8): 1698-1705, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37493499

RESUMO

INTRODUCTION: Among patients with non-valvular atrial fibrillation (AF) and percutaneous left atrial appendage closure (LAAC) undergoing direct current cardioversion (DCCV), the need for and use of LAA imaging and oral anticoagulation (OAC) is unclear. OBJECTIVE: The purpose of this study is to evaluate the real-world use of transesophageal echocardiography (TEE) or cardiac computed tomography angiography (CCTA) before DCCV and use of OAC pre- and post-DCCV in patients with AF status post percutaneous LAAC. METHODS: This retrospective single center study included all patients who underwent DCCV after percutaneous LAAC from 2016 to 2022. Key measures were completion of TEE or CCTA pre-DCCV, OAC use pre- and post-DCCV, incidence of left atrial thrombus (LAT) or device-related thrombus (DRT), incidence of peri-device leak (PDL), and DCCV-related complications (stroke, systemic embolism, device embolization, major bleeding, or death) within 30 days. RESULTS: A total of 76 patients with AF and LAAC underwent 122 cases of DCCV. LAAC consisted of 47 (62%), 28 (37%), and 1 (1%) case of Watchman 2.5, Watchman FLX, and Lariat, respectively. Among the 122 DCCV cases, 31 (25%) cases were identified as "non-guideline based" due to: (1) no OAC for 3 weeks and no LAA imaging within 48 h before DCCV in 12 (10%) cases, (2) no OAC for 4 weeks following DCCV in 16 (13%) cases, or (3) both in 3 (2%) cases. Among the 70 (57%) cases that underwent TEE or CCTA before DCCV, 16 (23%) cases had a PDL with a mean size of 3.0 ± 1.1 mm, and 4 (6%) cases had a LAT/DRT on TEE resulting in cancellation. There were no DCCV-related complications within 30 days. DISCUSSION: There is a widely varied practice pattern of TEE, CCTA, and OAC use with DCCV after LAAC, with a 6% rate of LAT/DRT. LAA imaging before DCCV appears prudent in all cases, especially within 1 year of LAAC, to assess for device position, PDL, and LAT/DRT.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cardiopatias , Acidente Vascular Cerebral , Trombose , Humanos , Estudos Retrospectivos , Cardioversão Elétrica/efeitos adversos , Apêndice Atrial/diagnóstico por imagem , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/prevenção & controle , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Ecocardiografia Transesofagiana , Resultado do Tratamento , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Cateterismo Cardíaco/efeitos adversos
6.
Pacing Clin Electrophysiol ; 46(7): 745-751, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37221927

RESUMO

BACKGROUND: Transesophageal echocardiography (TEE) and cardiac computed tomography angiography (CCTA) are currently utilized for left atrial appendage closure (LAAC) planning. During the recent global iodine contrast media shortage in 2022, cardiac magnetic resonance imaging (CMR) was utilized for the first time for LAAC planning. This study sought to assess the utility of CMR versus TEE for LAAC planning. METHODS: This single center retrospective study consisted of all patients who underwent preoperative CMR for LAAC with Watchman FLX or Amplatzer Amulet. Key measures were accuracy of LAA thrombus exclusion, ostial diameter, depth, lobe count, morphology, accuracy of predicted device size, and devices deployed per case. Bland-Altman Analysis was used to compare CMR versus TEE measurements of LAA ostial diameter and depth. RESULTS: 25 patients underwent preoperative CMR for LAAC planning. A total of 24 (96%) cases were successfully completed with 1.2 ± 0.5 devices deployed per case. Among the 18 patients who underwent intraoperative TEE, there was no significant difference between CMR versus TEE in LAA thrombus exclusion (CMR 83% vs. TEE 100% cases, p = .229), lobe count (CMR 1.7 ± 0.8 vs. TEE 1.4 ± 0.6, p = .177), morphology (p = .422), and accuracy of predicted device size (CMR 67% vs. TEE 72% cases, p = 1.000). When comparing the difference between CMR and TEE measurements, Bland-Altman analysis demonstrated no significant difference in LAA ostial diameter (CMR-TEE bias 0.7 mm, 95% CI [-1.1, 2.4], p = .420), but LAA depth was significantly larger with CMR versus TEE (CMR-TEE bias 7.4 mm, 95% CI [1.6, 13.2], p = .015). CONCLUSIONS: CMR is a promising alternative for LAAC planning in cases where TEE or CCTA are contraindicated or unavailable.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Trombose , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Ecocardiografia Transesofagiana/métodos , Imageamento por Ressonância Magnética , Trombose/diagnóstico por imagem , Cateterismo Cardíaco , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 32(10): 2824-2829, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33556991

RESUMO

Esophageal injury still occurs with high frequency during ablation of atrial fibrillation (AF). The purpose of this study is to provide a review of methods to protect the esophagus from injury during AF ablation. Despite advances in imaging and ablation, the potential risk of esophageal injury during AF ablation remains an important concern with a high occurrence of esophageal injury (≈15%). There have been numerous studies evaluating varied techniques for esophageal protection including active cooling and displacement of the esophagus. These techniques are reviewed in this manuscript as well as the role of esophageal protection in managing patients undergoing AF ablation procedure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Esôfago/diagnóstico por imagem , Esôfago/cirurgia , Humanos
8.
J Cardiovasc Electrophysiol ; 32(1): 67-70, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33155334

RESUMO

Deviation of the esophagus during atrial fibrillation (AF) ablation can reduce esophageal injury. This study reports upon a novel esophageal retractor that utilizes vacuum suction and mechanical deflection to deviate the esophagus. The device was used in seven patients undergoing cryoballoon AF ablation. The esophagus was deviated 31.9 ± 4.4 mm to the right and 28.2 ± 5.9 mm to the left. Endoscopy at 4.4 ± 1.5 days postablation showed no esophageal injury. This study demonstrates the safe and effective deviation of the esophagus without a trailing edge with an esophageal retractor utilizing vacuum suction and mechanical deflection.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Esôfago/diagnóstico por imagem , Esôfago/cirurgia , Humanos , Sucção , Vácuo
9.
J Cardiovasc Electrophysiol ; 32(11): 3027-3034, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34554620

RESUMO

INTRODUCTION: Defibrillation testing (DT) is recommended during the subcutaneous defibrillator (S-ICD) placement. We sought to compare 10 J shock impedance in sinus rhythm (SR) with 65 J defibrillation impedance and evaluate device position on a postimplant chest X-ray (CXR) using an intermuscular (IM) technique. METHODS: Consecutive S-ICD implantations between 12/2019 and 12/2020 at The Ohio State University were reviewed. All implantations were performed using a two-incision IM technique. Standard DT with 65 J shock and 10 J shock in SR were performed unless contraindicated. The PRAETORIAN score was calculated based on CXR. RESULTS: A total of 37 patients (age: 47.2 ± 15.8 years old, male: n = 26 [70.3%], body mass index: 30.1 ± 6.7 kg/m2 ) underwent IM S-ICD implantation, and of those, 27 (73%) underwent both 65 J shock and 10 J shock in SR. The coefficient of determination (R2 ) between 10 J shock impedance and 65 J shock impedance was 0.84. The mean of an impedance difference was 1.6 ± 4.8 Ω (minimum - 11 and maximum 8). Postimplant CXR was available for 33 out of 37 patients (89.2%). The PRAETORIAN score was less than 90 in all patients and the mean score was 32.7 ± 8.8. CONCLUSION: We demonstrated that 10 J shock impedance in SR correlated well with 65 J defibrillation impedance during IM S-ICD implantation. An IM implantation technique provides excellent generator location on postimplant CXR. The IM technique combined with 10 J shock in SR may be sufficient to predict and ensure the defibrillation efficacy of the S-ICD.


Assuntos
Desfibriladores Implantáveis , Adulto , Arritmias Cardíacas , Cardioversão Elétrica , Impedância Elétrica , Humanos , Masculino , Pessoa de Meia-Idade , Ohio , Tela Subcutânea
10.
J Cardiovasc Electrophysiol ; 32(2): 477-483, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33205561

RESUMO

INTRODUCTION: Frequent right AQ4ventricular pacing (≥40%) with a transvenous pacemaker (TVP) is associated with the risk of pacing-induced cardiomyopathy (PICM). Leadless pacemakers (LPs) have distinct physical and mechanical differences from TVP. The risk of PICM with LP is not known. To identify incidence, predictors, and long-term outcomes of PICM in LP and TVP patients. METHODS: The study comprised all pacemaker-dependent patients with LP or TVP who had left ventricular ejection fraction (LVEF) of ≥50 from 2014 to 2019. The incidence of PICM (≥10% LVEF drop) was assessed with an echocardiogram. Predictors for PICM were identified using multivariate analysis. Long-term outcomes after cardiac resynchronization (CRT) were assessed in both groups. RESULTS: A total of 131 patients with TVP and 67 with LP comprised the study. All patients in the TVP group and the majority in the LP group underwent atrioventricular node ablation. The mean follow-up duration in TVP and LP groups was 592 ± 549 and 817 ± 600 days, respectively. A total of 18 (13.7%) patients in TVP and 2 (3%) in LP developed PICM after a median duration of 254 (interquartile range: 470) days. The incidence of PICM was significantly higher with TVP compared with LP (p = .02). TVP as pacing modality was a positive (odds ratio [OR]: 1.07) while age was negative (OR: 0.94) predictor for PICM on multivariable analysis. Both patients in LP and all except two in the TVP group responded to CRT. CONCLUSION: Incidence of PICM is significantly lower with LP compared with TVP in pacemaker-dependent patients. Age and TVP as pacing modality were predictors for PICM.


Assuntos
Cardiomiopatias , Marca-Passo Artificial , Estimulação Cardíaca Artificial/efeitos adversos , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/epidemiologia , Humanos , Incidência , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda
11.
Trends Biochem Sci ; 41(8): 665-678, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27261332

RESUMO

Hundreds, perhaps thousands of previously unidentified functional small peptides could exist in most genomes, but these sequences have been generally overlooked. The discovery of genes encoding small peptides with important functions in different organisms has ignited the interest in these sequences and led to an increasing amount of effort towards their identification. Here, we review the advances, both computational and biochemical, that are leading the way in the discovery of putatively functional small open reading frame genes (smORFs), as well as the functional studies that have been carried out as a consequence of these searches. The evidence suggests that smORFs form a substantial part of our genomes, and that their encoded peptides could have a variety of important cellular functions.


Assuntos
Fases de Leitura Aberta/genética , Peptídeos/genética , Animais , Humanos , Peptídeos/metabolismo
12.
J Cardiovasc Electrophysiol ; 31(7): 1661-1669, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32369243

RESUMO

BACKGROUND: Deviation of the esophagus prevents esophageal injury during atrial fibrillation ablation. OBJECTIVES: This study is to evaluate, in animals, safety and effectiveness of a novel esophageal retractor that utilizes vacuum suction and mechanical force to deviate the esophagus. METHODS: Following general anesthesia, a radiopaque ruler was placed behind the animal perpendicular to the esophagus. The esophageal retractor was inserted and esophagram was completed. Suction force (280-300 mm Hg) was applied to the distal aspect of the device that resulted in adherence of the esophagus in a circumferential manner. Then movement of a deflecting arm was used to deviate the esophagus. Four animal studies completed: (a) deviation distance and presence of trailing edge; (b) effect of 1 hour continuous suction and deviation upon esophageal cellular architecture; (c) impact on luminal esophageal temperature (LET) during high power ablation; and (d) compatibility of esophageal retractor with electroanatomic mapping system. RESULTS: The distance of deviation to the right (26.6 ± 2.5 mm) was higher than to the left (18.7 ± 2.3 mm; P < .01). There was no esophageal trailing edge in 65/68 deviations (96%). With continuous suction for 1 hour, pathology revealed small, <1mm, circular area of hyperemia in the esophageal mucosa. During high power ablation, the maximum increase in LET was 0.2°C. Finally, there was no interference between the device and electro-anatomical mapping system. CONCLUSION: In animal models, the esophageal retractor utilizing vacuum suction was successful at deviating the esophagus without significant trailing edge and with minor (1 mm) injury with prolonged continuous suction.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Esôfago/cirurgia , Humanos , Sucção , Equipamentos Cirúrgicos , Vácuo
13.
J Cardiovasc Electrophysiol ; 30(10): 1994-2001, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31328298

RESUMO

INTRODUCTION: Subclinical atrial fibrillation (AF), in the form of cardiac implantable device-detected atrial high rate episodes (AHREs), has been associated with increased thromboembolism. An implantable cardioverter-defibrillator (ICD) lead with a floating atrial dipole may permit a single lead (DX) ICD system to detect AHREs. We sought to assess the utility of the DX ICD system for subclinical AF detection in patients, with a prospective multicenter, cohort-controlled trial. METHODS AND RESULTS: One hundred fifty patients without prior history of AF (age 59 ± 13 years; 108 [72%] male) were enrolled into the DX cohort and implanted with a Biotronik DX ICD system at eight centers. Age-, sex-, and left ventricular ejection fraction-matched single- and dual-chamber ICD cohorts were derived from a Cornell database and from the IMPACT trial, respectively. The primary endpoint were AHRE detection at 12 months. During median 12 months follow-up, AHREs were detected in 19 (13%) patients in the DX, 8 (5.3%) in the single-chamber, and 19 (13%) in the dual-chamber cohorts. The rate of AHRE detection was significantly higher in the DX cohort compared to the single-chamber cohort (P = .026), but not significantly different compared to the dual-chamber cohort. There were no inappropriate ICD therapies in the DX cohort. At 12 months, only 3.0% of patients in the DX cohort had sensed atrial amplitudes less than 1.0 mV. CONCLUSION: Use of a DX ICD lead allows subclinical AF detection with a single lead DX system that is superior to that of a conventional single-chamber ICD system.


Assuntos
Fibrilação Atrial/diagnóstico , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Tecnologia de Sensoriamento Remoto/instrumentação , Potenciais de Ação , Adulto , Idoso , Doenças Assintomáticas , Fibrilação Atrial/fisiopatologia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo , Estados Unidos
14.
J Cardiovasc Electrophysiol ; 30(11): 2453-2459, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31502324

RESUMO

BACKGROUND: An internal risk stratification algorithm was developed to decrease the risk of major adverse cardiac events (MACEs) during lead extractions (LEs). OBJECTIVE: To report upon the impact of a risk stratification algorithm (RISE [RIsk Stratification prior to lead Extraction] protocol) on outcomes of LEs in a high-volume center. METHODS: A retrospective review of a prospectively maintained LEs database was performed to identify features associated with MACEs. On the basis of the retrospective data, the RISE protocol differentiated LEs procedures into "High" and "Low" risk for occurrence of MACEs. High-risk LEs included dual-coil defibrillator lead (≥3 years), pacemaker and single-coil lead (≥5 years), and any StarFix coronary sinus lead. During the prospective evaluation of the RISE protocol, "High-risk" LEs were performed in an operating room (OR) or hybrid laboratory with the cardiac anesthesiologist, OR nursing team, perfusionist in the room, and a cardiac surgeon on the premises. "Low-risk" LEs were performed in the electrophysiology (EP) laboratory with anesthesia provided by EP nursing team. The preintervention (pre-RISE) and postintervention (post-RISE) group spanned 19 and 40 months and consisted of 449 (632 leads) and 751 patients (1055 leads), respectively. The primary outcome of MACEs in the two groups was compared. RESULTS: Protocol compliance was 100%. The primary outcome of MACEs occurred in 15 patients (3.34%) before and 12 (1.6%) after implementation of the RISE protocol (P = .04). CONCLUSION: RISE identified a low-risk group where minimal resources are needed and allowed for rapid intervention in the high-risk group that reduced the consequences of MACEs.


Assuntos
Protocolos Clínicos , Desfibriladores Implantáveis , Remoção de Dispositivo/efeitos adversos , Marca-Passo Artificial , Complicações Pós-Operatórias/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Bases de Dados Factuais , Remoção de Dispositivo/mortalidade , Feminino , Hospitais com Alto Volume de Atendimentos , Humanos , Masculino , Pessoa de Meia-Idade , Ohio , Complicações Pós-Operatórias/mortalidade , Estudos Prospectivos , Desenho de Prótese , Melhoria de Qualidade , Indicadores de Qualidade em Assistência à Saúde , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
15.
PLoS Biol ; 14(3): e1002395, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27015288

RESUMO

Translation of hundreds of small ORFs (smORFs) of less than 100 amino acids has recently been revealed in vertebrates and Drosophila. Some of these peptides have essential and conserved cellular functions. In Drosophila, we have predicted a particular smORF class encoding ~80 aa hydrophobic peptides, which may function in membranes and cell organelles. Here, we characterise hemotin, a gene encoding an 88aa transmembrane smORF peptide localised to early endosomes in Drosophila macrophages. hemotin regulates endosomal maturation during phagocytosis by repressing the cooperation of 14-3-3ζ with specific phosphatidylinositol (PI) enzymes. hemotin mutants accumulate undigested phagocytic material inside enlarged endo-lysosomes and as a result, hemotin mutants have reduced ability to fight bacteria, and hence, have severely reduced life span and resistance to infections. We identify Stannin, a peptide involved in organometallic toxicity, as the Hemotin functional homologue in vertebrates, showing that this novel regulator of phagocytic processing is widely conserved, emphasizing the significance of smORF peptides in cell biology and disease.


Assuntos
Proteínas de Drosophila/genética , Endossomos/metabolismo , Macrófagos/metabolismo , Neuropeptídeos/genética , Fases de Leitura Aberta , Proteínas 14-3-3/metabolismo , Sequência de Aminoácidos , Animais , Sequência Conservada , Proteínas de Drosophila/metabolismo , Drosophila melanogaster , Dados de Sequência Molecular , Fagocitose , Homologia de Sequência de Aminoácidos
16.
Bioorg Med Chem Lett ; 29(16): 2294-2301, 2019 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-31307887

RESUMO

CDK4 and CDK6 are kinases with similar sequences that regulate cell cycle progression and are validated targets in the treatment of cancer. Glioblastoma is characterized by a high frequency of CDKN2A/CCND2/CDK4/CDK6 pathway dysregulation, making dual inhibition of CDK4 and CDK6 an attractive therapeutic approach for this disease. Abemaciclib, ribociclib, and palbociclib are approved CDK4/6 inhibitors for the treatment of HR+/HER2- breast cancer, but these drugs are not expected to show strong activity in brain tumors due to poor blood brain barrier penetration. Herein, we report the identification of a brain-penetrant CDK4/6 inhibitor derived from a literature molecule with low molecular weight and topological polar surface area (MW = 285 and TPSA = 66 Å2), but lacking the CDK2/1 selectivity profile due to the absence of a basic amine. Removal of a hydrogen bond donor via cyclization of the pyrazole allowed for the introduction of basic and semi-basic amines, while maintaining in many cases efflux ratios reasonable for a CNS program. Ultimately, a basic spiroazetidine (cpKa = 8.8) was identified that afforded acceptable selectivity over anti-target CDK1 while maintaining brain-penetration in vivo (mouse Kp,uu = 0.20-0.59). To probe the potency and selectivity, our lead compound was evaluated in a panel of glioblastoma cell lines. Potency comparable to abemaciclib was observed in Rb-wild type lines U87MG, DBTRG-05MG, A172, and T98G, while Rb-deficient cell lines SF539 and M059J exhibited a lack of sensitivity.


Assuntos
Antineoplásicos/farmacologia , Neoplasias Encefálicas/tratamento farmacológico , Quinase 4 Dependente de Ciclina/antagonistas & inibidores , Quinase 6 Dependente de Ciclina/antagonistas & inibidores , Desenho de Fármacos , Glioblastoma/tratamento farmacológico , Inibidores de Proteínas Quinases/farmacologia , Antineoplásicos/síntese química , Antineoplásicos/química , Neoplasias Encefálicas/metabolismo , Neoplasias Encefálicas/patologia , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Quinase 4 Dependente de Ciclina/metabolismo , Quinase 6 Dependente de Ciclina/metabolismo , Relação Dose-Resposta a Droga , Ensaios de Seleção de Medicamentos Antitumorais , Glioblastoma/metabolismo , Glioblastoma/patologia , Humanos , Células MCF-7 , Estrutura Molecular , Inibidores de Proteínas Quinases/síntese química , Inibidores de Proteínas Quinases/química , Relação Estrutura-Atividade
17.
Pacing Clin Electrophysiol ; 42(1): 58-62, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30414285

RESUMO

BACKGROUND: Lead dislodgement (LD) is a well-recognized complication during implantation of cardiac implantable electronic devices (CIEDs). An intraprocedural protocol, referred to as reduction of LD protocol, was developed to reduce the risk of LD. METHODS: The protocol involved (1) inserting a straight stylet down the right atrial lead and applying forward pressure while monitoring for fluoroscopic stability, (2) visualizing all leads during deep inspiration to determine if there is adequate lead redundancy, and (3) having the patient take a deep breath and cough while pacing just at capture threshold to assess for loss of capture in each lead. Any intraprocedural change in the parameters fulfilling the predefined criteria for inadequate lead implantation prompted lead repositioning. Data regarding demographic factors, clinical characteristics, and incidence of LD in the first 30 days after implant was obtained from intramural CIED database. The preintervention (control) group spanned 27 months and consisted of a total of 4,294 leads while the postintervention (intervention) group spanned 17 months and consisted of 2,361 leads implanted. RESULTS: There was no significant difference in the demographic factors and clinical characteristics in the two groups. Protocol compliance was > 90%. There were 44 occurrences of LD (1.02%) before and 10 (0.4%) after implementation of the protocol. The protocol significantly reduced the incidence of LD during the 30 days after implant (P = 0.014). No clinical characteristic predicted the risk of LD. CONCLUSION: Intraprocedural maneuvers performed to assess the adequacy of lead implantation results in reduced risk of LD.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Eletrodos Implantados , Falha de Equipamento , Complicações Pós-Operatórias/prevenção & controle , Idoso , Eletrocardiografia , Feminino , Fluoroscopia , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco
18.
Pacing Clin Electrophysiol ; 42(12): 1552-1557, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31702059

RESUMO

BACKGROUND: The perioperative anesthesia care during subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is still evolving. OBJECTIVE: To assess the feasibility and safety of S-ICD implantation with monitored anesthesia care (MAC) versus general anesthesia (GA) in a tertiary care center. METHODS: This is a single-center retrospective study of patients undergoing S-ICD implantation between October 2012 and May 2019. Patients were categorized into MAC and GA group based on the mode of anesthesia. Procedural success without escalation to GA was the primary endpoint of the study, whereas intraprocedural hemodynamics, need of pharmacological support for hypotension and bradycardia, length of the procedure, stay in the post-anesthesia care unit, and postoperative pain were assessed as secondary endpoints. RESULTS: The study comprises 287 patients with MAC in 111 and GA in 176 patients. Compared to MAC, patients in GA group were younger and had a higher body mass index. All patients had successful S-ICD implantation. Only one patient (0.9%) in the MAC group was converted to GA. Despite a similar baseline heart rate (HR) and mean arterial blood pressure (MAP) in both groups, patients with GA had significantly lower HR and MAP during the procedure and more frequently required pharmacological hemodynamic support. Length of the procedure, stay in the postanesthesia care unit, and postoperative pain was similar in both groups. CONCLUSION: This retrospective experience suggests that implantation of S-ICD is feasible and safe with MAC. Use of GA is associated with more frequent administration of hemodynamic drugs during S-ICD implantation.


Assuntos
Anestesia/métodos , Desfibriladores Implantáveis , Implantação de Prótese/métodos , Anestesia Geral , Anestesia Local , Bradicardia/tratamento farmacológico , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Hipotensão/tratamento farmacológico , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Medição da Dor , Dor Pós-Operatória/prevenção & controle , Estudos Retrospectivos
19.
J Cardiovasc Electrophysiol ; 29(10): 1460-1466, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29964312

RESUMO

BACKGROUND: Cardiac implantable electronic device (CIED) infections associated with large, mobile vegetation adds to the complexity of lead extraction and is associated with significant patient morbidity and mortality. OBJECTIVE: To show the feasibility of concomitant cardiovascular implantable electronic device extraction and vacuum-assisted removal of lead-related vegetations. METHODS: This is a single-center retrospective case series of consecutive patients with persistent bacteremia, sepsis, or endocarditis despite medical therapy who have vegetations >2 cm and subsequently underwent immediate CIED lead extraction after debulking with vacuum-assisted suction. RESULTS: Eight patients underwent successful removal of 17 leads immediately after debulking of vegetations with vacuum-assisted device suction. Debulking procedure was not successful in 1 patient due to inability to direct the vacuum suction device into proper position. There were no intraprocedure complications related to the vacuum-assisted debulking. One patient required open sternotomy for tear of the coronary sinus ostium related to extraction of a left ventricular pacing electrode. There was no mortality within 30 days of the procedure. CONCLUSIONS: Based upon these clinical results, it is feasible for patients with infected CIED systems that have large right-sided vegetations to undergo vacuum-assisted debulking then immediately followed by percutaneous CIED removal in whom surgical removal is considered high risk.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos de Citorredução/métodos , Remoção de Dispositivo/métodos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Infecções Relacionadas à Prótese/terapia , Adulto , Idoso , Procedimentos Cirúrgicos de Citorredução/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sucção , Resultado do Tratamento , Vácuo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa