Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Paediatr Perinat Epidemiol ; 34(5): 504-512, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-31838751

RESUMO

BACKGROUND: Semen quality assessment in population-based epidemiologic studies presents logistical and financial challenges due to reliance on centralised laboratory semen analysis. The Trak Male Fertility Testing System is an FDA-cleared and validated at-home test for sperm concentration and semen volume, with a research use only sperm motility test. Here we evaluate the Trak System's overall utility among men participating in Pregnancy Study Online (PRESTO), a web-based study of North American couples planning pregnancy. METHODS: US male participants aged ≥21 years with ≤6 months of pregnancy attempt time at study enrolment were invited to participate in the semen testing substudy after completing their baseline questionnaire. Consenting participants received a Trak Engine (battery-powered centrifuge) and two test kits. Participants shared their test results via smartphone images uploaded to online questionnaires. Data were then linked with covariate data from the baseline questionnaire. RESULTS: Of the 688 men invited to participate, 373 (54%) provided consent and 271 (73%) completed at least one semen test result. The distributions of semen volume, sperm concentration, motile sperm concentration, total sperm count, and total motile sperm count were similar to 2010 World Health Organization (WHO) semen parameter data of men in the general population. The overall usability score for the Trak System was 1.4 on a 5-point Likert scale (1 = Very Easy, 5 = Difficult), and 92% of participants believed they performed the test correctly and received an accurate result. Lastly, men with higher motile sperm count were more likely to report feeling "at ease" or "excited" following testing, while men with low motile sperm count were more likely to report feeling "concerned" or "frustrated." Overall, 91% of men reported they would like to test again. CONCLUSIONS: The Trak System provides a simple and potentially cost-effective means of measuring important semen parameters and may be useful in population-based epidemiologic fertility studies.


Assuntos
Internet , Autoteste , Contagem de Espermatozoides/métodos , Motilidade dos Espermatozoides , Adulto , Estudos Epidemiológicos , Humanos , Infertilidade Masculina/diagnóstico , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Cuidado Pré-Concepcional , Análise do Sêmen/instrumentação , Análise do Sêmen/métodos , Contagem de Espermatozoides/instrumentação , Adulto Jovem
2.
Diagnostics (Basel) ; 11(6)2021 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-34199408

RESUMO

Blood sample collection and rapid separation-critical preanalytical steps in clinical chemistry-can be challenging in decentralized collection settings. To address this gap, the Torq™ zero delay centrifuge system includes a lightweight, hand-portable centrifuge (ZDrive™) and a disc-shaped blood collection device (ZDisc™) enabling immediate sample centrifugation at the point of collection. Here, we report results from clinical validation studies comparing performance of the Torq System with a conventional plasma separation tube (PST). Blood specimens from 134 subjects were collected and processed across three independent sites to compare ZDisc and PST performance in the assessment of 14 analytes (K, Na, Cl, Ca, BUN, creatinine, AST, ALT, ALP, total bilirubin, albumin, total protein, cholesterol, and triglycerides). A 31-subject precision study was performed to evaluate reproducibility of plasma test results from ZDiscs, and plasma quality was assessed by measuring hemolysis and blood cells from 10 subject specimens. The ZDisc successfully collected and processed samples from 134 subjects. ZDisc results agreed with reference PSTs for all 14 analytes with mean % biases well below clinically significant levels. Results were reproducible across different operators and ZDisc production lots, and plasma blood cell counts and hemolysis levels fell well below clinical acceptance thresholds. ZDiscs produce plasma samples equivalent to reference PSTs. Results support the suitability of the Torq System for remotely collecting and processing blood samples in decentralized settings.

3.
J Am Chem Soc ; 132(16): 5652-61, 2010 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-20359222

RESUMO

The peptidyl antibiotic bacitracin (Bc) is one of the most widely used antibiotics which can bind divalent transition metal ions, including Mn(II), Co(II), Ni(II), Cu(II), and Zn(II). The metal binding is essential for its antimicrobial activity. Previous analysis of the hyperfine-shifted (1)H NMR signals of Co(II)-Bc A(1) revealed the structure of the metal binding environment and a potential hydrophobic site important for the bioactivity of this antibiotic. Co(II)-Bc in DMSO shows relatively sharper hyperfine-shifted (1)H NMR signals compared with the spectrum acquired in an aqueous solution, allowing more thorough analysis of the signals with 1D and 2D NMR methods. Pyrophosphate and derivatives bind to Co(II)-Bc to form kinetically inert ternary complexes. The coordinated D-Glu-4 is found detached from the metal center of metallobacitracin upon trimetaphosphate binding, implying its role in the antibiotic activity of Bc. We further demonstrate in this report the structure-function relationship on desamido-Bc of low antibiotic activity by the use of NMR, wherein D-Glu-4 is suggested to be important for the bioactivity of Bc. The interaction of the phospho-moiety with Bc is also reflected by DNA binding, wherein metal-free Bc does not bind DNA, whereas various metal complexes of Bc do. Cu(II)-Bc was further demonstrated to bind and oxidatively cleave DNA under reduction conditions in the air. It also exhibited a significant oxidative activity toward catechol oxidation, showing enzyme-like saturation kinetics with k(cat) = 7.0 x 10(-3) s(-1) and k(cat)/K(m) = 2.1 M(-1) s(-1) aerobically and k(cat) = 0.38 s(-1) and k(cat)/K(m) = 14.7 M(-1) s(-1) in the presence of 32 mM of H(2)O(2). The binding of pyrophosphate moiety to metallobacitracin, the detachment of d-Glu-4, and the significant oxidative activity of Cu(II)-Bc provide further insights into the bioactivity of this metallopeptide and Cu-oxygen chemistry.


Assuntos
Antibacterianos/química , Antibacterianos/metabolismo , Bacitracina/química , Bacitracina/metabolismo , DNA/metabolismo , Difosfatos/metabolismo , Ácido Glutâmico/metabolismo , Cobalto/metabolismo , Cobre/metabolismo , Interações Hidrofóbicas e Hidrofílicas , Cinética , Espectroscopia de Ressonância Magnética , Modelos Moleculares , Oxirredução , Ligação Proteica , Conformação Proteica
4.
Fertil Steril ; 107(2): 358-364.e4, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27887718

RESUMO

OBJECTIVE: To evaluate the analytical performance and usability of the Trak Male Fertility Testing System, a semiquantitative (categorical) device recently US Food and Drug Administration (FDA)-cleared for measuring sperm concentration in the home by untrained users. DESIGN: A three-site clinical trial comparing self-reported lay user results versus reference results obtained by computer-aided semen analysis (CASA). SETTING: Simulated home use environments at fertility centers and urologist offices. PATIENT(S): A total of 239 untrained users. INTERVENTION(S): None. MAIN OUTCOME MEASURE(S): Sperm concentration results reported from self-testing lay users and laboratory reference method by CASA were evaluated semiquantitatively against the device's clinical cutoffs of 15 M/mL (current World Health Organization cutoff) and 55 M/mL (associated with faster time to pregnancy). Additional reported metrics include assay linearity, precision, limit of detection, and ease-of-use ratings from lay users. RESULT(S): Lay users achieved an accuracy (versus the reference) of 93.3% (95% confidence interval [CI] 84.1%-97.4%) for results categorized as ≤15 M/mL, 82.4% (95% CI 73.3%-88.9%) for results categorized as 15-55 M/mL, and 95.5% (95% CI 88.9%-98.2%) for results categorized as >55 M/mL. When measured quantitatively, Trak results had a strong linear correlation with CASA measurements (r = 0.99). The precision and limit of detection studies show that the device has adequate reproducibility and detection range for home use. Subjects generally rated the device as easy to use. CONCLUSION(S): The Trak System is an accurate tool for semiquantitatively measuring sperm concentration in the home. The system may enable screening and longitudinal assessment of sperm concentration at home. CLINICAL TRIAL REGISTRATION NUMBER: ClinicalTrials.gov identifier: NCT02475395.


Assuntos
Centrifugação/instrumentação , Fertilidade , Infertilidade Masculina/diagnóstico , Autocuidado/instrumentação , Contagem de Espermatozoides/instrumentação , Espermatozoides/patologia , Adulto , California , Centrifugação/normas , Desenho de Equipamento , Humanos , Infertilidade Masculina/etiologia , Infertilidade Masculina/patologia , Infertilidade Masculina/fisiopatologia , Limite de Detecção , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Padrões de Referência , Reprodutibilidade dos Testes , Autocuidado/métodos , Autocuidado/normas , Contagem de Espermatozoides/métodos , Contagem de Espermatozoides/normas , Adulto Jovem
5.
Inorg Chem ; 38(20): 4498-4502, 1999 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-11671162

RESUMO

Cobalt(II) has been utilized as an external paramagnetic (1)H NMR probe for the study of the structure of dendrimers that possess specifically located metal recognition sites. The isotropically shifted (1)H NMR signals of the Co(II) complexes of two 2,6-diamidopyridine-containing dendrimers have been fully assigned by means of 1D and 2D NMR techniques, including NOE difference, EXSY, COSY, and TOCSY. T(1) values of the isotropically shifted signals were used to calculate metal-proton distances to build a molecular model of the internal structure of the dendrimers. The presence of sizable cavities within the dendrimers was observed, including a loosely packed conformation for the 2,6-diamidopyridine moiety to bind to potential guest molecules.

6.
J Inorg Biochem ; 91(1): 46-58, 2002 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-12121761

RESUMO

Bacitracin is a widely used metallopeptide antibiotic produced by Bacillus subtilis and Bacillus licheniformis with a potent bactericidal activity directed primarily against Gram-positive organisms. This antibiotic requires a divalent metal ion such as Zn(2+) for its biological activity, and has been reported to bind several other transition metal ions, including Mn(2+), Co(2+), Ni(2+), and Cu(2+). Despite the widespread use of bacitracin since its discovery in the early 1940s, the structure-activity relationship of this drug has not been established and the coordination chemistry of its metal complexes was not fully determined until recently. This antibiotic has been suggested to influence cell functioning through more than one route. Since bacterial resistance against bacitracin is still rare despite several decades of widespread use, this antibiotic can serve as an ideal lead for the design of potent peptidyl antibiotics lacking bacterial resistance. In this review, the results of physical (including NMR, EPR, and EXAFS) and molecular biological studies regarding the synthesis and structure of bacitracin, the coordination chemistry of its metal derivatives, the mechanism of its antibiotic actions, its influence on membrane function, and its structure and function relationship are discussed.


Assuntos
Antibacterianos/química , Bacitracina/química , Metais/química , Antibacterianos/metabolismo , Antibacterianos/farmacologia , Bacitracina/metabolismo , Bacitracina/farmacologia , Proteínas de Bactérias/metabolismo , Membrana Celular/metabolismo , Parede Celular/metabolismo , Humanos , Espectroscopia de Ressonância Magnética , Modelos Moleculares , Estrutura Molecular , Relação Estrutura-Atividade
7.
Angew Chem Int Ed Engl ; 37(3): 307-310, 1998 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-29711250

RESUMO

Used individually or combinatorially, unique isocyanate-based dendritic monomers generate homo- and heterofunctional materials (the sketch shows schematically a molecule with a heterofunctional surface). Tier construction by combinatorial monomer addition offers new avenues to macromolecular architectural design and the control of physical properties.

8.
Chem Res Toxicol ; 16(10): 1385-94, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14565779

RESUMO

Carcinogenic aryl hydrazines produce C8-arylated purine adducts. The effect of these adducts on DNA conformation and their role in hydrazine carcinogenesis are unknown. Here, we describe a new synthetic route to produce these adducts that is also compatible with the synthesis of the corresponding phosphoramidites needed for oligonucleotide synthesis. Two oligonucleotides were prepared, an unmodified oligonucleotide, d((5)(')CGCGCGCGCG(3)(')), and a C8-phenylguanine modified oligonucleotide, d((5)(')CGCGCGCGCG(3)(')) (G = 8-phenylguanine). These oligonucleotides were compared using thermal denaturation, circular dichroism, NMR, and molecular modeling. The phenyl modification destabilizes the B DNA form and stabilizes the Z DNA form such that the B:Z ratio is near one under physiological conditions. In light of recent studies that show a role for Z DNA in gene expression and cell transformation, Z DNA stabilization by C8-arylguanine formation from aryl hydrazines may be relevant to their role in carcinogenesis.


Assuntos
DNA Forma Z/química , DNA Forma Z/síntese química , Guanina/análogos & derivados , Guanina/química , Conformação de Ácido Nucleico , Oligodesoxirribonucleotídeos/química , Oligodesoxirribonucleotídeos/síntese química , Pareamento de Bases , Dicroísmo Circular , Desoxiguanosina/química , Hidrazinas/química , Ligação de Hidrogênio , Espectroscopia de Ressonância Magnética , Modelos Moleculares , Desnaturação de Ácido Nucleico , Prótons , Temperatura
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa